C500 Technical Data

Cummins Power Generator


400KW/500KVA
JLT POWER Cummins Series
C500 Technical Data

Powered by
Cummins KTA19-G2

General feature:
♦ Assembled by Cummins diesel engine and Stamford alternator.
♦ Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery charger and float battery charger as standard supply scope.
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers.

Genset Main Technical Data:


Genset Model C500
Prime Power(60HZ) 350KW / 438KVA
Standby Power(60HZ) 400KW / 500KVA
Frequency/Speed 60Hz/1800rpm
Standard Voltage 220V/127V
Voltage Available 440V/254V
Phases Three phases, four wires
Manufacturer

(1) PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in
accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of
operation. In accordance with ISO 3046-1.
(2) ESP: The Standby Power Rating is applicable for supplying emergency power in variable load applications
for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed.
JLT POWER Cummins Series
C500 Technical Data
Cummins Engine Data:
Manufacturer Chongqing Cummins Engine Co.
Ltd.
Model
KTA19-G2
Engine speed
1800rpm
Engine power

--------------------Standby power
448kw /600HP
--------------------Prime power
392kw /525HP
Type
4 cycle, In-line, 6-cylinder
Aspiration
Turbocharged and Aftercooled
Bore * Stroke
159*159 mm
Displacement
18.9 L
Compression ratio
13.9:1
Idle speed
675 - 775 r/min
Brake mean effective pressure
1386-1586kPa
Piston speed
9.5 m/s
Friction horsepower
63kw(85HP)

Fuel Consumption:
JLT POWER Cummins Series
C500 Technical Data
ALTERNATOR Specifications:

Brand Stamford

Model HCI444F

Output power 550kva

AVR model AS440

Number of phase 3

Power factor (Cos Phi) 0.8

Altitude  1000 m

Overspeed 2250RPM

Number of Pole 4

Exciter type SELF


EXCITED
Insulation class
H
Voltage regulation
±0.5%
Sustained short circuit current
300% (3 IN) : 10s
Total harmonics (TGH/THC)
<4%
Wave form : NEMA = TIF
< 50
Wave form : I.E.C. = THF
<2%
Bearing
single
Coupling
Direct

Circuit breaker specification:


Manufacturer XIAMEN LRONGXK ELECTRIC
Brand CO.,LTD
Model LRONGXK
Capacity XKM1-1600
Voltage 1600amp
220V

Starting Battery specification:

Battery Voltage 12V


Battery Capacity 200amp
Quantity 2 pcs
Battery type sealed maintanence free battery
JLT POWER Cummins Series
C500 Technical Data
Control system:

Deepse a 6020
Auto start and stop control
panel

Deepsea 6020 is an auto mains ♦Volt adjuster and frequency


failure controller for single adjuster.
generator, it can monitor and ♦Emergency stop
protect the generator working all ♦Fail to start
Power switch
the time. it has a LCD display
which clearly shows the status of Lamp switch
the engine. this controller includeFeatures: Power indicator
seven inputs and six outputs. ♦Protection: Automatic start/stop, Operation buttons
This controller can also be load transfer and alarming of LCD display
programmed using the frong generator;
panel or by using DSE ♦ CAN and magnetic pick-up
configuration Suite PC software. versions.
♦PC and front panel configurable
Parameters: ♦4 digital inputs and 3 analogue
This controller can provide inputs.
Generator frequency, Under/over ♦6 outputs(4 configurable on
speed, Generator volts, magnetic pick-up, 6 configurable on
Generator current, Engine oil Canbus version).
pressure, Engine coolant ♦3 phase generator and mains
temperature, Flexible fuel level, voltage monitoring.
Hours run counter, Battery volts, ♦remote start on or off load. Open type
Fail to start/stop, Emergency ♦advanced metering capability.
Stop. Failed to reach loading ♦test button.
voltage/frequency, Charge fail, ♦protected solid state outputs.
Loss of magnetic pick-up signal, ♦transfer between mains and
Low DC voltage, CAN diagnostics generator power.
and CAN fail/error, Mains volts 3 ♦user-friendly set-up and button
phase, Mains frequency, AMF layout.
indications ♦multiple engine parameters are
monitored simultaneously.
Protection: ♦module can be configured to suit
♦Low Oil Pressure individual applications.
♦High water Temperature ♦IP 65 rating offers advanced Silent type
♦High voltage and low voltage resistance to water ingress when
♦Overspeed gasket is fitted.
JLT POWER Cummins Series
C500 Technical Data
Soundproof Enclosure Specification:

multi-way air intake and exhaust guarantee the


power performance of the generator.
large-scale impedance combined type silencer
effectively reduce noise of the generator.
internal high performance rubber damper and
flexible materials reduce vibration.
Base mounted fuel tank supports the generator
running for 8 hours.

Cold steel materials of the canopy.


Best powder paint. Transparent viewing window make the control panel
Zinc plated and Corrosion resistance. clear at a glance.
Elegant appearance and reliable quality. Emergency stop button mounted on the canopy
Stainless steel locks and hinges. exterior for urgency.
Access to all weather conditions. Cooling fluid injection hole is kept on the ceiling
Fireproof, waterproof and dustproof. crust.
High quality soundproof materials could efficiently Pipe of lube oil and cooling fluid is mounted on the
reduce noise. bottom of generator for easy let.
Big base fuel tank in the frame guarantee sufficient Fuel fill and battery can easy be accessed by
diesel supply. lockable door.
180° revolvable and disassemble door for easy Cooling fan and battery are fully guarded.
maintenance. Heat insulation of exhaust smoke system inside
Concave lockable access door for easy operation the canopy.
and indefectible. Forkman slot is for choice.
Lights inside of the canopy for maintenance. Lifting ear is mounted in the base frame.

Weight and Dimensions

1.Open Version: 2. Soundproof Version:

Open Type (Standard Configuration)


Soundproof Type
Overall Size: 3163×1155 ×1790mm(L*W*H) Overall size: 3800× 1500×1900mm(L*W*H)
Weight: 3846kg Weight: 4606kg
JLT POWER Cummins Series
C500 Technical Data
Supply scope
1.Standard supply scope:

Exhaust silencer

Starting battery

Float battery charger

Auto Control Panel Base Frame


Main Ciruit Breaker Filter
Cooling Radiator Starting Motor
Bellow

2. Optional supply scope:

AutoFuel Pump External daily fueltank ABBBreaker


ATS fuelandwater

Elec.coolant Heater
Trailer &
Synchronization Lub oil heater OildrainPump SilentCanopy
System