GINLONG TECHNOLOGIES CO.,LTD.
S5-GC(25-40)K
Solis Three Phase Inverters
Efficient Safe
• Max. efficiency 98.7% • IP66
• String current up to 16A • AFCI protection, proactively reduces fire risk
• 3/4 MPPT design, supports multiple • Globally recognised branded componentry for
orientation system design longer life
• Night time PID recovery function, increases • Intelligent redundant fan-cooling
overall system yield (optional)
• Wide voltage range and low startup voltage
Smart Economic
• Supports export power control • Supports GPRS/WiFi communication with less
• Intelligent string monitoring, smart I-V wiring and reduced installation costs
curve scan • > 150% DC/AC ratio
• Supports RS485, WiFi, GPRS • Supports high power modules for lower
• Scan to register on SolisCloud, supports installation costs
remote upgrade and control • Supports aluminium wire access to reduce cost
Models:
S5-GC25K / S5-GC30K
S5-GC33K / S5-GC36K
S5-GC40K
360º View
www.solisinverters.com
DATASHEET S5-GC(25-40)K
Models 25K 30K 33K 36K 40K
Input DC
Recommended max. PV power 37.5 kW 45 kW 49.5 kW 54 kW 60 kW
Max. input voltage 1100 V
Rated voltage 600 V
Start-up voltage 180 V
MPPT voltage range 200-1000 V
Max. input current 32 A / 32 A / 32 A 4*32 A
Max. short circuit current 40 A / 40 A / 40 A 4*40 A
MPPT number/Max. input strings number 3/6 4/8
Output AC
Rated output power 25 kW 30 kW 33 kW 36 kW 40 kW
Max. apparent output power 27.5 kVA 33 kVA 36.3 kVA 39.6 kVA 44 kVA
Max. output power 27.5 kW 33 kW 36.3 kW 39.6 kW 44 kW
Rated grid voltage 3/N/PE, 220 V / 380 V, 230 V / 400 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 38.0 A / 36.1 A 45.6 A / 43.3 A 50.1 A / 47.6 A 54.7 A / 52.0 A 60.8 A / 57.7 A
Max. output current 41.8 A 50.2 A 55.1 A 60.2 A 66.9 A
Power factor >0.99 (0.8 leading - 0.8 lagging)
THDi <3%
Efficiency
Max. efficiency 98.5% 98.6% 98.7%
EU efficiency 98.1% 98.2% 98.3%
Protection
DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Surge protection DC Type II / AC Type II
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes
I/V Curve scanning Yes
Integrated AFCI (DC arc-fault circuit protection) Yes (1)
Integrated PID recovery Optional
Integrated DC switch Optional
General Data
Dimensions (W*H*D) 647*629*252 mm
Weight 37 kg
Topology Transformerless
Self-consumption (night) <1 W
Operating ambient temperature range -25 ~ +60°C
Relative humidity 0-100%
Ingress protection IP66
Cooling concept Intelligent redundant fan-cooling
Max. operation altitude 4000 m
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
Grid connection standard
UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530
Safety/EMC standard IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
Features
DC connection MC4 connector
AC connection OT terminal
Display LCD
Communication RS485, Optional: Wi-Fi, GPRS
(1) Activation required.