Product data sheet

Specifications

current control relay, Harmony


Control Relays, 5A, 2CO,
overcurrent or undercurrent
detection, 0.15…15A, 24…240V
AC DC
RM35JA32MW

Product availability: Stock - Normally stocked in distribution


facility

Price*: 177.00 USD

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of Product Harmony Control Relays

Relay Type Current control relay

Product or Component Type Current control relay

Relay name RM35JA

Relay monitored parameters Overcurrent or undercurrent detection

time delay Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault


Adjustable 1...20 s, 0 + 10 % Ti- inhibition time delay upon startup

Switching capacity in VA 1250 VA

Minimum switching current 10 mA 5 V DC

Maximum switching current 5 A AC/DC

Maximum power consumption in 3.5 VA AC


VA
Measurement range 150 mA...15 A current AC/DC

Utilisation category AC-12 IEC 60947-5-1


AC-13 IEC 60947-5-1
AC-14 IEC 60947-5-1
AC-15 IEC 60947-5-1
DC-12 IEC 60947-5-1
DC-13 IEC 60947-5-1
DC-14 IEC 60947-5-1

Contacts type and composition 2 C/O

Complementary
Reset time 1500 ms time delay

Maximum switching voltage 250 V AC/DC

Supply voltage limits 20.4…264 V AC/DC

operating voltage tolerance - 15 % + 10 % Un

Maximum power consumption in 0.6 W DC


W
Control circuit frequency 40...70 Hz +/- 10 %

Resistance across terminals 0.005 Ohm E3-M terminals


0.015 Ohm E2-M terminals
0.05 Ohm E1-M terminals

Output contacts 2 C/O

Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.

Dec 24, 2024 1


Nominal output current 5A

Maximum measuring cycle 30 ms measurement cycle as true rms value

Hysteresis 5…50 % threshold setting

delay at power up 0.3 s

Measurement accuracy +/- 10 % of the full scale value

Repeat accuracy +/- 0.5 % input and measurement circuit


+/- 2 % time delay

Measurement error 0.05 %/°C with temperature variation


1 by volt over the whole range with voltage variation

Polarity No DC

Threshold setting 10...100 %

Marking CE : EMC 89/336/EEC


CE : 73/23/EEC

Overvoltage category III conforming to IEC 60664-1

Insulation resistance > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
> 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
> 1 MOhm 500 V DC between supply and measurement IEC 60255-5
> 500 MOhm 500 V DC between supply and relay output IEC 60664-1
> 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
> 1 MOhm 500 V DC between supply and measurement IEC 60664-1

[Ui] rated insulation voltage 250 V IEC 60664-1

Operating position Any position without derating

Connections - terminals Screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end

Tightening torque 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1

Housing material Self-extinguishing plastic

Local signalling for power ON LED (green)


for relay ON LED (yellow)

Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715

Electrical durability 100000 cycles

Mechanical durability 30000000 cycles

Operating rate <= 360 operations/hour full load

[Un] rated nominal voltage 24...240 V AC/DC 50/60 Hz, non self-powered

Safety reliability data MTTFd = 296.8 years


B10d = 270000

Contacts material Cadmium free

Width 1.4 in (35 mm)

Control Type Without test button

Net Weight 0.29 lb(US) (0.13 kg)

Environment
Immunity to microbreaks 50 ms

Electromagnetic compatibility Emission standard for industrial environments conforming to IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments
conforming to IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2

Standards IEC 60255-6

2 Dec 24, 2024


Product Certifications GL
UL
GOST
C-tick
CSA

Ambient Air Temperature for -40…158 °F (-40…70 °C)


Storage
Ambient air temperature for -4…122 °F (-20…50 °C)
operation
Relative humidity 95 % 131 °F (55 °C) IEC 60068-2-30

Vibration resistance 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6


1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1

Shock resistance 15 gn 11 ms IEC 60255-21-1

IP degree of protection IP20 IEC 60529 terminals)


IP30 IEC 60529 casing)

Pollution degree 3 IEC 60664-1

Dielectric test voltage 2 kV AC 50 Hz, 1 min IEC 60255-5


2 kV AC 50 Hz, 1 min IEC 60664-1

Non-dissipating shock wave 4 kV IEC 60255-5


4 kV IEC 60664-1
4 kV IEC 61000-4-5

Ordering and shipping details


Category US10CP222380

Discount Schedule 0CP2

GTIN 3389119405225

Returnability Yes

Country of origin CA

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 1.77 in (4.500 cm)

Package 1 Width 3.15 in (8.000 cm)

Package 1 Length 3.74 in (9.500 cm)

Package 1 Weight 4.797 oz (136.000 g)

Unit Type of Package 2 S03

Number of Units in Package 2 48

Package 2 Height 11.81 in (30.000 cm)

Package 2 Width 11.81 in (30.000 cm)

Package 2 Length 15.75 in (40.000 cm)

Package 2 Weight 16.074 lb(US) (7.291 kg)

Contractual warranty
Warranty 18 months

Dec 24, 2024 3


Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain
partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use
Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg CO2 eq,


58
Total Life cycle)

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled


Yes
cardboard

Packaging without single use


Yes
plastic

Pro-active compliance
EU RoHS Directive (Product out of EU RoHS legal
scope)

5e3fdf99-611b-4d07-
SCIP Number
ad17-6eba84ab488b

REACh Regulation REACh Declaration

China RoHS Regulation China RoHS declaration

4 Dec 24, 2024


WARNING: This product can
expose you to chemicals
including: Lead and lead
compounds, which is known
to the State of California to
California proposition 65
cause cancer and birth
defects or other reproductive
harm. For more information
go to
www.P65Warnings.ca.gov

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

The product must be


disposed on European Union
WEEE markets following specific
waste collection and never
end up in rubbish bins.

Take-back No

Dec 24, 2024 5


Product data sheet RM35JA32MW

Dimensions Drawings

Current Control Relays

Dimensions and Mounting

6 Dec 24, 2024


Product data sheet RM35JA32MW

Connections and Schema

Current Control Relays

Wiring Diagram

Dec 24, 2024 7


Product data sheet RM35JA32MW

Application Schemes

Example: Detection of Jamming on a Crusher (Overcurrent Function)


Current measured ≤ 15 A

Current measured > 15 A

8 Dec 24, 2024


Product data sheet RM35JA32MW

Technical Description

Function Diagrams

Undercurrent Detection
Without memory ("No Memory" mode)

With memory ("Memory" mode)

Overcurrent Detection
Without memory ("No Memory" mode)

With memory ("Memory" mode)

Legend
Ti Starting inhibition time delay
Tt Time delay after crossing of threshold
Un Supply voltage
I Monitored current
H Hysteresis
I> Overcurrent threshold
I< Undercurrent threshold
11-12/11-14, 21-22/21-24 Output relay connections
Relay status: black color = energized.

NOTE: In "Memory" mode, the relay opens when crossing of the threshold
is detected and then stays in that position. The power supply voltage must
be switched off to reset the product.

Dec 24, 2024 9


Product data sheet RM35JA32MW

Technical Illustration

Dimensions

10 Dec 24, 2024


Product data sheet RM35JA32MW

Image of product / Alternate images

Alternative

Dec 24, 2024 11


Product data sheet RM35JA32MW

12 Dec 24, 2024


Product data sheet RM35JA32MW

Dec 24, 2024 13


Product data sheet RM35JA32MW

Image of product in real life situation

14 Dec 24, 2024

You might also like