CHARGER TESTER
XL—206H
User manual
★Thank for using this designation
★Please read user’s manual particular before use
★Please advert conserve
★Contact way:+86 13112974088
CHARGER TESTER
Security Code
◆Please carefully read this Code before using the machine
1. Do not damp this machine and do intense mechanical movement
2. Make sure the local voltage 220V±5%. Please pay attention to the warning
message on the machine.
3. The power cord is the main power supply is connected, power cord Do not
leave any items, not the power cable in place easy for users to malfunction, or
the high temperature environment of the source of fire.
4. The power cord for the single-phase three-wire plug, grounded. If the plug
does not fit into an AC outlet, contact an electrician to replace the obsolete
outlet without letting the security role of the single-phase three-wire plug
failure,
5. Do not let the power outlet overload or expanding long power cord so as to
avoid the risk of fire or electric shock.
6. As an additional protective effect when not in use Turn the power off; the
blackout or does not use the machine for a long period of time, should unplug it,
plug to prevent surges caused by the machine through the power cord.
7. Trench openings on the chassis for ventilation and also used to ensure the
reliability of the machine work to prevent its overheating. Other items do not
block the ventilation holes.
8. Before using the machine operator must be trained and designated person
responsible
9. When the machine following, please unplug it from the outlet on the power
- 1 -
CHARGER TESTER
plug, and professional maintenance staff to conduct a comprehensive
maintenance:
A) power cord or plug is damaged or frayed;
B) have a liquid spilled inside the machine;
C) the machine by the rain and irrigated;
D) the machine does not work properly.
10. Rreplacement parts should be sure the service technician to use alternative
components and performance parts specified by the manufacturer. The
unrecognized alternative components may cause a fire, electric shock or other
hazards.
11. In strict accordance with the manual operation, unauthorized alterations
against the machine, desoldering any consequences that result does not assume
any responsibility.
12. If you have any question please email for us :[email protected]
Or contact us by phone : 13112974088(WeChat same number)
- 2 -
CHARGER TESTER
Directory
一. Functional Overview
二.The basic functions of the instrument
三. Instruments Appearance
四. Instrument instructions
五. Test parameters set
1.comprehensive test set
1) Select test group
2) Test step set
3) Un-load set
4) CV setting
5) CR settings
6) CC setting
7) Overcurrent settings
8) Short-circuit current settings
9) R+/R- setting
10) VD setting
11) AB two-point connection status setting
12) MTK+ setting
13) MTK- setting
2. Comprehensive test results
3. CV/CC/CR test
六. Instrument characteristics parameters
七.Guarantees
- 3 -
CHARGER TESTER
一. Functional Overview
1.Charger tester for testing various types of battery chargers, DC power
supply, power adapter, no-load and load characteristics designed special test
equipment, testing stable, fast, convenient and simple operation, and can
adaptthe testing of all types of chargers. Instrument built constant voltage,
constant current, constant resistance load, users can easily select the type of load.
Instrument-specific constant voltage mode can a realistic simulation charger
process.
2. The general power product testing process is cumbersome and requires
multiple test instruments to work together, such as multimeters, electronic loads,
and power resistor loads. Many cell phone chargers require actual battery load
to test, and ordinary load meters cannot be tested. Not only the test speed is slow,
the operation is complicated, and human error misjudgment and the like are
easily caused, which leads to low production efficiency, false detection of
defective products, and serious influence on product quality. And the ordinary
load meter can't test the AC input current of the charger, can't test the load
characteristic of the high-pass fast charge charger, can't identify the polarity
automatically to the automatic polar charger too, thus can't meet the needs of the
charger manufacturer too.
3. If you use the full Chinese LYT-206H charger integrated tester designed by
our company, you only need to select a good test item, and then set the
parameters of each test item, you can accurately and quickly test the charger's
indicators. If it is set to the fastest speed, it only takes 0.3 seconds to complete a
- 4 -
CHARGER TESTER
test. The buzzer sound or LED indicator can determine whether it is qualified.
Can automatically test Qualcomm QC2.0/3.0, MTK PE protocol flash charge.
The instrument has a parameter saving function, which can save 6 different test
parameters, so that users can call up the corresponding setting parameters when
testing different
二. The basic functions of the instrument
1. Integrated test: to provide up to eight step test, the first step for the no-load
test, 2 - 8 step can be arbitrarily selected constant voltage, constant current,
constant resistance, overcurrent, short-circuit test mode,VD,AB.
2.CV test: The instrument can work independently in constant voltage mode
3.CR test: the instrument can work independently in constant resistance mode
4.CC test: the instrument can work independently in the constant current mode
三. Instrument Appearance
1. Instrument front panel has four components, used to display the user interface
and test data LCD display, keyboard, input interface, two-color LED status
indication lights.
lcd Operating the keyboard
LCD monitors Indicator
TC4 TC3 TC2 TC1 TP4 TP3 TP2 TP1
- 5 -
CHARGER TESTER
2. Port description
TP1:
2 3
1 4
Connect 1 and 2 to the positive output of the power supply, 3 and 4 to the
negative output of the power supply.
TP2: Test the voltage of D+, D-
1 2
TP3: Test AB point connection status
1 2
TP4: 1 connection D+, 2 connection D- (fast charge interface for QC2.0/3.0)
1 2
3. The instrument panel as shown below
AC AC input
output
- 6 -
CHARGER TESTER
四. Instrument instructions
1.Function menu of the machiner
CMB TEST
CV MODE
CC MODE
CR MODE
2. CMB TEST: universal testing project: un-load test, the constant pressure test,
test of constant resistance, constant current test over the flow test, the
short-circuit current test. The general phone battery charger simply test two
projects: no-load and load testing, load usually choose the constant pressure
load or constant current load
1)
.CV MODE
Voltage can be set to the 0-19.99V, test charger AC input current and the DC
output current
2)
.CC MODE
Current can be set to the 0-6.00A, test charger AC input current and the DC
output voltage
3)
.CR MODE
Resistance can be set to 0-99.9 European test charger AC input current and DC
output current, voltage
五. Test parameter settings
Boot after four menu options, "▲" "▼" button to select the test items need to be
carried out, and press the "ENT" key to enter the corresponding function.
1. CMB TEST : this feature is selected, enter the parameter setting:
- 7 -
CHARGER TESTER
1)Setting Description
CALL 1 GROUP
START TEST
MOD PRG
Press "▲" "▼" to move the cursor to select the desired operation
Choose to be the transfer of parameter sets (1-6 group),
Press the "ENT" key to perform the selected operation, press the "ESC" return
function to select the menu
The instrument can store 6 groups of the barrier test parameters to facilitate the
user to test different charger
2).Test step set
TEST STEP:2
1. UL
2. CC
Press "▲" "▼" to move the cursor
Press“ ”“ ” Select cursor step test project
Cursor in 1-8 working steps, press the "ENT" key to enter the setting interface
of the current step
Press the "ESC" key to enter the test interface
The instrument provides up to 8 continuous step test, can be arbitrarily set in
step 1-8 step
The first step is the default no-load test, step 2-8 can be arbitrarily set: constant
voltage, constant current, constant resistance, overcurrent, short circuit,VD,AB.
- 8 -
CHARGER TESTER
3).UN-load settings
UNLOAD T=0.0S
POLA:FXD VC:5V QC2.0/3.0 voltage selection
Iac:240mA
Udc: 4.00 --- 6.00 V
min max
Among them, "polarity" has three options: "AUTO", "ATT" and "FXD".
"AUTO" means that the polarity of the charger's output will be automatically
converted with the polarity of the load, and there is no need to distinguish
between positive and negative polarity when testing.
“ATT” means that the polarity of the charger's output will be automatically
converted with the polarity of the load. In the constant voltage test, the
instrument will force the polarity of the charger and test the constant voltage
characteristics twice to ensure that the charger is in both poles. Can work
properly under sex.
“FXD” means that the polarity of the charger is fixed. If “FXD” is selected, the
instrument will alarm if it detects a negative voltage. This can detect whether
the direct charge output leads are reversed. When selecting "Automatic" or
"Automatic Switching", the instrument only displays the positive and negative
voltage, but it will not alarm the polarity.
Press "ENT" or "ESC" key to return to the previous interface
4)
.Constant voltage setting
CV SET T=0.0S
U=3.7V
Iac: 240mA
Idc:0.30--- 0.70 A
Press “▲”
“▼” move cursor。
- 9 -
CHARGER TESTER
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
5).Constant resistance settings
CR SET T=0.0 S
R=10.0Ω Iac=240mA
Idc:0.30 ---0.60 A
Udc: 3.00 --- 6.00V
Press “▲”
“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
6)
.Constant current set
CC SET T=0.0S
I=0.40A
Iac=240mA
Udc=3.50--- 5.80 V
Press “▲”
“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
7)
.Overcurrent settings
OC SET
0.00 --- 0.40 A
Press “▲”
“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
8).Short-circuit current settings
SHORT SET
0.00 --- 0.40 A
- 10 -
CHARGER TESTER
9).R+、R- setting
R+/R- SET
min 10――300KΩ max
press“▲”“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
10).VD SET
VD SET T=0.1S
D+:1.8—2.2 V D+ Voltage range setting
D-: 2.5—2.8 V D- Voltage range setting
press“▲”“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
11). AB two-point connection status test
AB SET:SHORT/OPEN
press“▲”“▼” move cursor。
press“ ”“ ” modify the value at the cursor
Press “ENT”or“ESC”come back
12)MTK+ SET
MTK+SET T=0.0S testing time
I=1.00A setting cc value
Iac=50mA
Udc:6.50---7.50 V
Voltage min max
For fast charge of MTK PE protocol, after this step is called, the instrument
- 11 -
CHARGER TESTER
will control the output voltage of the charger up one gear
If the current voltage is 5V, adjust the voltage to 7V after calling this
step
13)MTK- SET
MTK- SET T=0.0S
I=1.00A
Iac=50mA
Udc:6.50---7.50 V
For fast charge of MTK PE protocol, after this step is called, the instrument
will control the charger output voltage down one file
If the current voltage is 7V, call this step and adjust the voltage to 5V
2. Comprehensive test results
Iac= 0.0mA
I=0.00A U= 0.00V
I1=0.00A U1=0.00V
UL: CV:
After the charger and instrument are properly connected, the instrument will
automatically start testing according to the settings, and indicate the current test
procedure with an arrow to display the current measurement parameters in real
time. After the measurement is completed, “√” is displayed after the qualified
item, and “×” is displayed after the item is not qualified. All of them are
qualified to turn on the green light, any one item fails to turn on the red light,
and a long-ring alarm sound is issued.
After the test is completed, the measurement parameter value of each step can
be displayed by pressing “ ”“ ”. Press "ESC" to return to the function
selection interface. After the test is completed, the instrument will automatically
load the current and discharge for 5 seconds. That is, disconnect the charger
input (220V power) within 5 seconds after the test is completed. The instrument
can discharge the charger's capacitor.
- 12 -
CHARGER TESTER
press“▼”Check the pass rate。
TOTAL:1000
PASS:980
NG:20
RATE:98.0%
Press ESC key at this time to clear the counter, and the counter will be cleared
automatically after shutdown.
3. Constant voltage, constant current, constant resistance test
Press "▲" "▼" key modify the set parameters
Connect the charger, the key "ENT" to start the test, this time the red light
“ESC" key to stop the test, this time the green light
Press "ESC" to return to the function selection interface
4. After the completion of all tests, the statistics can be seen in the test interface
buttons "▼"
- 13 -
CHARGER TESTER
六. Instrument characterization parameters
1. Input Voltage:AC220V±5%
Output Voltage:220V±5%
3.Temperature:0~40℃
4.Relative humidity:40~80%
6.SIZE:255×255×115(mm)
7.Weight:3.5kg
8.Electrical specifications:
RANGE Resolution Precision Control rang Control
precision
AC input current AC:0-200mA 0.2mA ±2mA ――― ―――
DC voltage 0-10V 10mV ±0.5%+1 ――― ―――
DC voltage 10-20.00V 20mV ±1%+1 ――― ―――
DC current 0-6A 3mA ±0.01A ――― ―――
CV ――― ――― ――― 0-20.00V ±0.02V
CC ――― ――― ――― 0-6A ±0.01A
CR ――― ――― ――― 0-99.9Ω ±1.5%
Certificate of conformity
Model:
Serial number:
Date:
Inspector:
- 14 -
CHARGER TESTER
七. Guarantees
1. Limited warranty period
Limited warranty period (hardware and labor) 1 year
Limited warranty period (test fixture) 30 days
2. Limited scope of guarantee
We guarantee to the end user (customer) that within the warranty period from
the date of purchase by the customer, each product, including its associated
software and accessories, does not have any defects in materials and processes.
The limited warranty covers only defects that occur when the product is used
normally, and does not include any other issues, such as those caused by: (a)
Improper repair or modification. (b) does not comply with product
specifications for operation, unauthorized modification, or incorrect operation.
(c) Damage caused by force majeure.
3. Maintenance period: lifetime maintenance, but the user must bear
maintenance costs.
4. service method
The warranty method is for the customer to return to the repair by the dealer.
5. Precautions
Please save your purchase invoice or receipt to avoid unnecessary obstacles to
your maintenance. There are no parts inside the instrument that you can repair.
If you have any problems, please contact your dealer.
- 15 -