CHARGER TESTER

XL—206H

User manual

★Thank for using this designation


★Please read user’s manual particular before use
★Please advert conserve
★Contact way:+86 13112974088
CHARGER TESTER

Security Code
◆Please carefully read this Code before using the machine

1. Do not damp this machine and do intense mechanical movement

2. Make sure the local voltage 220V±5%. Please pay attention to the warning

message on the machine.

3. The power cord is the main power supply is connected, power cord Do not

leave any items, not the power cable in place easy for users to malfunction, or

the high temperature environment of the source of fire.

4. The power cord for the single-phase three-wire plug, grounded. If the plug

does not fit into an AC outlet, contact an electrician to replace the obsolete

outlet without letting the security role of the single-phase three-wire plug

failure,

5. Do not let the power outlet overload or expanding long power cord so as to

avoid the risk of fire or electric shock.

6. As an additional protective effect when not in use Turn the power off; the

blackout or does not use the machine for a long period of time, should unplug it,

plug to prevent surges caused by the machine through the power cord.

7. Trench openings on the chassis for ventilation and also used to ensure the

reliability of the machine work to prevent its overheating. Other items do not

block the ventilation holes.

8. Before using the machine operator must be trained and designated person

responsible

9. When the machine following, please unplug it from the outlet on the power
- 1 -
CHARGER TESTER

plug, and professional maintenance staff to conduct a comprehensive

maintenance:

A) power cord or plug is damaged or frayed;

B) have a liquid spilled inside the machine;

C) the machine by the rain and irrigated;

D) the machine does not work properly.

10. Rreplacement parts should be sure the service technician to use alternative

components and performance parts specified by the manufacturer. The

unrecognized alternative components may cause a fire, electric shock or other

hazards.

11. In strict accordance with the manual operation, unauthorized alterations

against the machine, desoldering any consequences that result does not assume

any responsibility.

12. If you have any question please email for us :[email protected]

Or contact us by phone : 13112974088(WeChat same number)

- 2 -
CHARGER TESTER

Directory
一. Functional Overview
二.The basic functions of the instrument
三. Instruments Appearance
四. Instrument instructions
五. Test parameters set
1.comprehensive test set
1) Select test group
2) Test step set
3) Un-load set
4) CV setting
5) CR settings
6) CC setting
7) Overcurrent settings
8) Short-circuit current settings
9) R+/R- setting
10) VD setting
11) AB two-point connection status setting
12) MTK+ setting
13) MTK- setting
2. Comprehensive test results
3. CV/CC/CR test
六. Instrument characteristics parameters

七.Guarantees

- 3 -
CHARGER TESTER

一. Functional Overview

1.Charger tester for testing various types of battery chargers, DC power

supply, power adapter, no-load and load characteristics designed special test

equipment, testing stable, fast, convenient and simple operation, and can

adaptthe testing of all types of chargers. Instrument built constant voltage,

constant current, constant resistance load, users can easily select the type of load.

Instrument-specific constant voltage mode can a realistic simulation charger

process.

2. The general power product testing process is cumbersome and requires

multiple test instruments to work together, such as multimeters, electronic loads,

and power resistor loads. Many cell phone chargers require actual battery load

to test, and ordinary load meters cannot be tested. Not only the test speed is slow,

the operation is complicated, and human error misjudgment and the like are

easily caused, which leads to low production efficiency, false detection of

defective products, and serious influence on product quality. And the ordinary

load meter can't test the AC input current of the charger, can't test the load

characteristic of the high-pass fast charge charger, can't identify the polarity

automatically to the automatic polar charger too, thus can't meet the needs of the

charger manufacturer too.

3. If you use the full Chinese LYT-206H charger integrated tester designed by

our company, you only need to select a good test item, and then set the

parameters of each test item, you can accurately and quickly test the charger's

indicators. If it is set to the fastest speed, it only takes 0.3 seconds to complete a
- 4 -
CHARGER TESTER

test. The buzzer sound or LED indicator can determine whether it is qualified.

Can automatically test Qualcomm QC2.0/3.0, MTK PE protocol flash charge.

The instrument has a parameter saving function, which can save 6 different test

parameters, so that users can call up the corresponding setting parameters when

testing different

二. The basic functions of the instrument

1. Integrated test: to provide up to eight step test, the first step for the no-load

test, 2 - 8 step can be arbitrarily selected constant voltage, constant current,

constant resistance, overcurrent, short-circuit test mode,VD,AB.

2.CV test: The instrument can work independently in constant voltage mode

3.CR test: the instrument can work independently in constant resistance mode

4.CC test: the instrument can work independently in the constant current mode

三. Instrument Appearance

1. Instrument front panel has four components, used to display the user interface

and test data LCD display, keyboard, input interface, two-color LED status

indication lights.

lcd Operating the keyboard


LCD monitors Indicator

TC4 TC3 TC2 TC1 TP4 TP3 TP2 TP1

- 5 -
CHARGER TESTER

2. Port description
TP1:

2 3
1 4

Connect 1 and 2 to the positive output of the power supply, 3 and 4 to the

negative output of the power supply.


TP2: Test the voltage of D+, D-

1 2

TP3: Test AB point connection status

1 2

TP4: 1 connection D+, 2 connection D- (fast charge interface for QC2.0/3.0)

1 2

3. The instrument panel as shown below

AC AC input
output

- 6 -
CHARGER TESTER

四. Instrument instructions

1.Function menu of the machiner

CMB TEST
CV MODE
CC MODE
CR MODE

2. CMB TEST: universal testing project: un-load test, the constant pressure test,

test of constant resistance, constant current test over the flow test, the

short-circuit current test. The general phone battery charger simply test two

projects: no-load and load testing, load usually choose the constant pressure

load or constant current load

1)
.CV MODE

Voltage can be set to the 0-19.99V, test charger AC input current and the DC

output current

2)
.CC MODE

Current can be set to the 0-6.00A, test charger AC input current and the DC

output voltage

3)
.CR MODE

Resistance can be set to 0-99.9 European test charger AC input current and DC

output current, voltage

五. Test parameter settings

Boot after four menu options, "▲" "▼" button to select the test items need to be

carried out, and press the "ENT" key to enter the corresponding function.

1. CMB TEST : this feature is selected, enter the parameter setting:

- 7 -
CHARGER TESTER

1)Setting Description

CALL 1 GROUP
START TEST
MOD PRG

Press "▲" "▼" to move the cursor to select the desired operation

Choose to be the transfer of parameter sets (1-6 group),

Press the "ENT" key to perform the selected operation, press the "ESC" return

function to select the menu

The instrument can store 6 groups of the barrier test parameters to facilitate the

user to test different charger

2).Test step set

TEST STEP:2
1. UL
2. CC

Press "▲" "▼" to move the cursor

Press“ ”“ ” Select cursor step test project

Cursor in 1-8 working steps, press the "ENT" key to enter the setting interface

of the current step

Press the "ESC" key to enter the test interface

The instrument provides up to 8 continuous step test, can be arbitrarily set in

step 1-8 step

The first step is the default no-load test, step 2-8 can be arbitrarily set: constant

voltage, constant current, constant resistance, overcurrent, short circuit,VD,AB.

- 8 -
CHARGER TESTER

3).UN-load settings
UNLOAD T=0.0S
POLA:FXD VC:5V QC2.0/3.0 voltage selection
Iac:240mA
Udc: 4.00 --- 6.00 V

min max

Among them, "polarity" has three options: "AUTO", "ATT" and "FXD".

"AUTO" means that the polarity of the charger's output will be automatically

converted with the polarity of the load, and there is no need to distinguish

between positive and negative polarity when testing.

“ATT” means that the polarity of the charger's output will be automatically

converted with the polarity of the load. In the constant voltage test, the

instrument will force the polarity of the charger and test the constant voltage

characteristics twice to ensure that the charger is in both poles. Can work

properly under sex.

“FXD” means that the polarity of the charger is fixed. If “FXD” is selected, the

instrument will alarm if it detects a negative voltage. This can detect whether

the direct charge output leads are reversed. When selecting "Automatic" or

"Automatic Switching", the instrument only displays the positive and negative

voltage, but it will not alarm the polarity.

Press "ENT" or "ESC" key to return to the previous interface

4)
.Constant voltage setting
CV SET T=0.0S
U=3.7V
Iac: 240mA
Idc:0.30--- 0.70 A

Press “▲”
“▼” move cursor。
- 9 -
CHARGER TESTER

press“ ”“ ” modify the value at the cursor


Press “ENT”or“ESC”come back
5).Constant resistance settings
CR SET T=0.0 S
R=10.0Ω Iac=240mA
Idc:0.30 ---0.60 A
Udc: 3.00 --- 6.00V

Press “▲”
“▼” move cursor。

press“ ”“ ” modify the value at the cursor

Press “ENT”or“ESC”come back

6)
.Constant current set
CC SET T=0.0S
I=0.40A
Iac=240mA
Udc=3.50--- 5.80 V

Press “▲”
“▼” move cursor。

press“ ”“ ” modify the value at the cursor

Press “ENT”or“ESC”come back

7)
.Overcurrent settings
OC SET
0.00 --- 0.40 A

Press “▲”
“▼” move cursor。

press“ ”“ ” modify the value at the cursor


Press “ENT”or“ESC”come back
8).Short-circuit current settings

SHORT SET
0.00 --- 0.40 A

- 10 -
CHARGER TESTER

9).R+、R- setting
R+/R- SET
min 10――300KΩ max

press“▲”“▼” move cursor。

press“ ”“ ” modify the value at the cursor

Press “ENT”or“ESC”come back


10).VD SET
VD SET T=0.1S

D+:1.8—2.2 V D+ Voltage range setting


D-: 2.5—2.8 V D- Voltage range setting
press“▲”“▼” move cursor。

press“ ”“ ” modify the value at the cursor

Press “ENT”or“ESC”come back


11). AB two-point connection status test
AB SET:SHORT/OPEN

press“▲”“▼” move cursor。

press“ ”“ ” modify the value at the cursor

Press “ENT”or“ESC”come back


12)MTK+ SET
MTK+SET T=0.0S testing time
I=1.00A setting cc value
Iac=50mA
Udc:6.50---7.50 V

Voltage min max


For fast charge of MTK PE protocol, after this step is called, the instrument

- 11 -
CHARGER TESTER

will control the output voltage of the charger up one gear


If the current voltage is 5V, adjust the voltage to 7V after calling this
step
13)MTK- SET
MTK- SET T=0.0S
I=1.00A
Iac=50mA
Udc:6.50---7.50 V
For fast charge of MTK PE protocol, after this step is called, the instrument
will control the charger output voltage down one file
If the current voltage is 7V, call this step and adjust the voltage to 5V

2. Comprehensive test results


Iac= 0.0mA
I=0.00A U= 0.00V
I1=0.00A U1=0.00V
UL: CV:

After the charger and instrument are properly connected, the instrument will

automatically start testing according to the settings, and indicate the current test

procedure with an arrow to display the current measurement parameters in real

time. After the measurement is completed, “√” is displayed after the qualified

item, and “×” is displayed after the item is not qualified. All of them are

qualified to turn on the green light, any one item fails to turn on the red light,

and a long-ring alarm sound is issued.

After the test is completed, the measurement parameter value of each step can

be displayed by pressing “ ”“ ”. Press "ESC" to return to the function

selection interface. After the test is completed, the instrument will automatically

load the current and discharge for 5 seconds. That is, disconnect the charger

input (220V power) within 5 seconds after the test is completed. The instrument

can discharge the charger's capacitor.


- 12 -
CHARGER TESTER

press“▼”Check the pass rate。

TOTAL:1000
PASS:980
NG:20
RATE:98.0%

Press ESC key at this time to clear the counter, and the counter will be cleared

automatically after shutdown.

3. Constant voltage, constant current, constant resistance test

Press "▲" "▼" key modify the set parameters

Connect the charger, the key "ENT" to start the test, this time the red light

“ESC" key to stop the test, this time the green light

Press "ESC" to return to the function selection interface

4. After the completion of all tests, the statistics can be seen in the test interface

buttons "▼"

- 13 -
CHARGER TESTER

六. Instrument characterization parameters

1. Input Voltage:AC220V±5%

Output Voltage:220V±5%

3.Temperature:0~40℃

4.Relative humidity:40~80%

6.SIZE:255×255×115(mm)

7.Weight:3.5kg

8.Electrical specifications:

RANGE Resolution Precision Control rang Control


precision
AC input current AC:0-200mA 0.2mA ±2mA ――― ―――

DC voltage 0-10V 10mV ±0.5%+1 ――― ―――

DC voltage 10-20.00V 20mV ±1%+1 ――― ―――

DC current 0-6A 3mA ±0.01A ――― ―――

CV ――― ――― ――― 0-20.00V ±0.02V

CC ――― ――― ――― 0-6A ±0.01A

CR ――― ――― ――― 0-99.9Ω ±1.5%

Certificate of conformity

Model:

Serial number:

Date:

Inspector:

- 14 -
CHARGER TESTER

七. Guarantees

1. Limited warranty period

Limited warranty period (hardware and labor) 1 year

Limited warranty period (test fixture) 30 days

2. Limited scope of guarantee

We guarantee to the end user (customer) that within the warranty period from

the date of purchase by the customer, each product, including its associated

software and accessories, does not have any defects in materials and processes.

The limited warranty covers only defects that occur when the product is used

normally, and does not include any other issues, such as those caused by: (a)

Improper repair or modification. (b) does not comply with product

specifications for operation, unauthorized modification, or incorrect operation.

(c) Damage caused by force majeure.

3. Maintenance period: lifetime maintenance, but the user must bear

maintenance costs.

4. service method

The warranty method is for the customer to return to the repair by the dealer.

5. Precautions

Please save your purchase invoice or receipt to avoid unnecessary obstacles to

your maintenance. There are no parts inside the instrument that you can repair.

If you have any problems, please contact your dealer.

- 15 -