PRESSURE SYSTEMS CAM60/25
309CAM60/25
APPLICATION
Automatic high pressure groups coupled with self priming jet pumps. They are
very silent and reliable and particularly suitable to increase pressure from a
water system, to supply water from wells and in domestic high pressure groups.
OPERATING CONDITIONS
- Liquid temperature up to 35°C
- Ambient temperature up to 40°C
- Total suction lift up to 8 m
- Continuous duty
MOTOR
- 2-Pole induction motor
(n = 2850 min-1)
- Insulation Class F
- Protection IP44 CAM100
MATERIALS
- Butyl membrane tank
- Flexible hose with connection
- Adjusted switch on/off pressure
1.6 - 3.2 bar with cable
- Pressure gauge
- Brass connection
CAM100/25
G
DNM
DNA
TYPE DIMENSIONS mm WEIGHT
kg
H
H1
CAM100/25
H2
F
E A B
D C
TROUBLESHOOTING
PUMP GUIDE
PROBLEM CAUSE ACTION
Check if non return is installed correctly or if dirt is
Non- return valve is dirty or is not installed correctly.
preventing it from closing properly.
Check the “tyre” valve under the black cap on the back
The pump unit frequently The tank bladder is deflated. of the tank. If no air comes out, disconnect the pump
switches on and off, completely and inflate the bladder to 1.5-1.7 bar.
even with a tap/outlet closed.
Check the “tyre” valve under the black cap on the back
The tank bladder has burst.
of the tank. If water comes out, replace the bladder.
Turn the nut on the small spring on the inside of the
The shut-off pressure inside the pressure pressure switch inwards. Make sure not to exceed the
switch is set too low.
maximum pressure of which the pump is capable.
Check the pressure gauge on the pump unit and
The pump unit switches on Water pressure is dropping, causing the confirm that the pressure is dropping, check for a
when all outlets are closed. pump to switch on.
leak in the system.
Make sure that all outlets are closed. Check the
Not all outlets are closed.
pressure gauge to confirm.
Burst or leaking pipe. Check for leaks.
The pump unit does not
switch off. Faulty pressure switch. Ensure that the pressure switch is in working order.
Make sure that the pump is primed and that water is a
There is no water coming into the pump. ble to move freely into the pump and that all inlet
valves are open.
Ensure that the capacitor is correctly connected and / or
Faulty capacitor.
not damaged, replace if necessary.
The pump unit makes a Remove the fan cover and fan at the back of the pump
humming sound, motor and ensure that the shaft can turn freely. If not,
but does not switch on. The pump shaft is being “trapped” the possible causes include bearing failure, excessive dirt
and unable to turn.
on the inside of the volute casing or other restrictions in
the pump.
Ensure that the water inlet is connected to the inlet of the
The pump inlet and outlet are pump (front connection) and the outlet to the outlet of
incorrectly connected.
the pump (top connection).
Check that there are no restrictions in the system
Restriction in pipeline.
that would prevent water from flowing.
The pump switches on,
but there is no pressure.
Open the volute casing and ensure that the impeller
Broken, blocked or faulty impeller.
is not faulty.
Make sure that the pump is primed and that water is
There is no water coming into the pump. able to move freely into the pump and that all inlet v
alves are open.
Water is leaking out
between the pump and Faulty mechanical seal. Replace the mechanical seal.
motor of the unit.
Grinding noise originating Replace the motor bearings. Bearing failure is often
from the motor Bearing failure. caused by mechanical seal failure.
of the pump unit.
No incoming power to the pump. Ensure that the pump is plugged in and switched on.
The pump unit does not Faulty pressure switch. Ensure that the pressure switch is in working condition.
switch on at all.
Test the motor windings and ensure that the motor
“Burnt out” motor. is in working condition.