Microscopic techniques
Microscopic techniques
A light microscope is a biology laboratory instrument or tool that uses visible light to
detect and magnify very small objects, and enlarging them.
They use lenses to focus light on the specimen, magnifying it thus producing an
image. The specimen is normally placed close to the microscopic lens.
Microscopic magnification varies greatly depending on the types and number of
lenses that make up the microscope. Depending on the number of lenses,
i. Simple light microscope (it has low magnification because it uses a single
lens) and t
ii. The Compound light microscope (it has a higher magnification compared
to the simple microscope because it uses at least two sets of lenses, an
objective lens, and an eyepiece). The lenses are aligned in that; they can be
able to bend light for efficient magnification of the image.
The functioning of the light microscope is based on its ability to focus a beam of light
through a specimen, which is very small and transparent, to produce an image. The
image is then passed through one or two lenses for magnification for viewing. The
transparency of the specimen allows easy and quick penetration of light. Specimens
can vary from bacterial to cells and other microbial particles.
BIOLOGICAL TECHNIQUES 1
The modern types of Light Microscopes include:
This is the most basic optical Microscope used in microbiology laboratories which
produces a dark image against a bright background. Made up of two lenses, it is
widely used to view plant and animal cell organelles including some parasites such as
Paramecium after staining with basic stains.
Its functionality is based on being able to provide a high-resolution image, which
highly depends on the proper use of the microscope. This means that an adequate
amount of light will enable sufficient focusing of the image, to produce a quality
image.
It is also known as a compound light microscope.
BIOLOGICAL TECHNIQUES 2
Principle of Bright field Microscope
For a specimen to be the focus and produce an image under the Bright field Microscope, the
specimen must pass through a uniform beam of the illuminating light. Through differential
absorption and differential refraction, the microscope will produce a contrasting image.
The specimens used are prepared initially by staining to introduce color for easy contracting
characterization. The colored specimens will have a refractive index that will differentiate it
from the surrounding, presenting a combination of absorption and refractive contrast.
The functioning of the microscope is based on its ability to produce a high-resolution image
from an adequately provided light source, focused on the image, producing a high-quality
image.
The specimen which is placed on a microscopic slide is viewed under oil immersion or/and
covered with a cover slip.
BIOLOGICAL TECHNIQUES 3
The optical parts of the microscope are used to view, magnify, and produce an image from a
specimen placed on a slide. These parts include:
1. Eyepiece – also known as the ocular. This is the part used to look through the
microscope. It’s found at the top of the microscope. Its standard magnification is 10x
with an optional eyepiece having magnifications from 5X – 30X.
2. Eyepiece tube – its the eyepiece holder. It carries the eyepiece just above the
objective lens. In some microscopes such as the binoculars, the eyepiece tube is
flexible and can be rotated for maximum visualization, for variance in distance. For
monocular microscopes, they are none flexible.
3. Objective lenses – These are the major lenses used for specimen visualization. They
have a magnification power of 40x-100X. There are about 1- 4 objective lenses placed
on one microscope, in that some are rare facing and others face forward. Each lens
has its own magnification power.
4. Nose piece – also known as the revolving turret. It holds the objective lenses. It is
movable hence it cal revolve the objective lenses depending on the magnification
power of the lens.
5. The Adjustment knobs – These are knobs that are used to focus the microscope.
There are two types of adjustment knobs i.e fine adjustment knobs and the coarse
adjustment knobs.
6. Stage – This is the section on which the specimen is placed for viewing. They have
stage clips hold the specimen slides in place. The most common stage is a mechanical
stage, which allows the control of the slides by moving the slides using the
mechanical knobs on the stage instead of moving it manually.
7. Aperture – This is a hole on the microscope stage, through which the transmitted
light from the source reaches the stage.
8. Microscopic illuminator – This is the microscopes light source, located at the base.
It is used instead of a mirror. it captures light from an external source of a low voltage
of about 100v.
9. Condenser – These are lenses that are used to collect and focus light from the
illuminator into the specimen. They are found under the stage next to the diaphragm
of the microscope. They play a major role in ensuring clear sharp images are
produced with a high magnification of 400X and above. The higher the magnification
of the condenser, the more the image clarity. More sophisticated microscopes come
with an Abbe condenser that has a high magnification of about 1000X.
BIOLOGICAL TECHNIQUES 4
10. Diaphragm – it’s also known as the iris. It’s found under the stage of the microscope
and its primary role is to control the amount of light that reaches the specimen. Its an
adjustable apparatus, hence controlling the light intensity and the size of the beam of
light that gets to the specimen. For high-quality microscopes, the diaphragm comes
attached with an Abbe condenser and combined they are able to control the light focus
and light intensity that reaches the specimen.
11. Condenser focus knob – this is a knob that moves the condenser up or down thus
controlling the focus of light on the specimen.
13. The rack stop – It controls how far the stages should go preventing the objective lens
from getting too close to the specimen slide which may damage the specimen. It is
responsible for preventing the specimen slide from coming too far up and hit the
objective lens.
Vastly used in Microbiology, this microscope is used to view fixed and live specimens that
have been stained with basic stains. This gives contrast for easy visibility under the
microscope. Therefore it can be used to identify basic bacteria cells and parasitic protozoan’s
such as Paramecium.
BIOLOGICAL TECHNIQUES 5
Some of its applications include:
1. Used to visualize and study the animal cells
2. Used to visualize and study plant cells.
3. Used to visualize and study the morphologies of bacterial cells
4. Used to identify parasitic protozoan’s such as Paramecium.
Disadvantages
1. The aperture diaphragm may cause great contrast which may distort the outcome of
the image, therefore iris diaphragm is preferred.
2. It cannot be used to view live specimens such as bacterial cells. Only fixed specimens
can be viewed under the bright field microscope.
3. Maximum magnification of the bright field microscope is 100x but modification can
readjust the magnification to 1000x which is the optimum magnification of bacterial
cells.
4. It has low contrast hence most specimens must be stained for them to be visualized.
5. Use of oil immersion may distort the image
6. The use of coverslip may damage the specimen
7. Staining may introduce extraneously unwanted details into the specimen or
contaminate the specimen.
8. The microscope needs a strong light source for magnification and sometimes the light
source may produce a lot of heat which may damage or kill the specimen.
Microbiology, the branch of science that has so vastly extended and expanded our
knowledge of the living world, owes its existence to Antoni van Leeuwenhoek.
In 1673, with the aid of a crude microscope consisting of a biconcave lens enclosed in
two metal plates, Leeuwenhoek introduced the world to the existence of microbial
forms of life.
Over the years, microscopes have evolved from the simple, single-lens instrument of
Leeuwenhoek, with a magnification of 300 X, to the present-day electron microscopes
capable of magnifications greater than 250,000X.
Microscopes are designated as either light microscopes or electron microscopes.
BIOLOGICAL TECHNIQUES 6
Light microscopes use visible light or ultraviolet rays to illuminate specimens. They
include bright field, dark field, phase-contrast, and fluorescent instruments.
This is similar to the ordinary light microscope; however, the condenser system is
modified so that the specimen is not illuminated directly.
The condenser directs the light obliquely so that the light is deflected or scattered
from the specimen, which then appears bright against a dark background.
Living specimens may be observed more readily with dark field than with bright field
microscopy.
1. The dark-ground microscopy makes use of the dark-ground microscope, a special type
of compound light microscope.
2. The dark-field condenser with a central circular stop, which illuminates the object
with a cone of light, is the most essential part of the dark-ground microscope.
3. This microscope uses reflected light instead of transmitted light used in the ordinary
light microscope.
4. It prevents light from falling directly on the objective lens.
5. Light rays falling on the object are reflected or scattered onto the objective lens with
the result that the microorganisms appear brightly stained against a dark background.
BIOLOGICAL TECHNIQUES 7
Uses of Dark field Microscope
The dark ground microscopy has the following uses:
It is useful for the demonstration of very thin bacteria not visible under ordinary
illumination since the reflection of the light makes them appear larger.
This is a frequently used method for rapid demonstration of Treponema pallidum in
clinical specimens.
It is also useful for the demonstration of the motility of flagellated bacteria and
protozoa.
Dark field is used to study marine organisms such as algae, plankton, diatoms, insects,
fibers, hairs, yeast and protozoa as well as some minerals and crystals, thin polymers
and some ceramics.
Dark field is used to study mounted cells and tissues.
It is more useful in examining external details, such as outlines, edges, grain
boundaries and surface defects than internal structure.
BIOLOGICAL TECHNIQUES 8
It was first described in 1934 by Dutch physicist Frits Zernike.
When light passes through cells, small phase shifts occur, which are invisible to the human
eye. In a phase-contrast microscope, these phase shifts are converted into changes in
amplitude, which can be observed as differences in image contrast.
This is a type of optical microscope whereby small light deviations know as phase
shifts occur during light penetration into the unstained specimen. These phase shifts
are converted into the image to mean, when light passes through the opaque
specimen, the phase shifts brighten the specimen forming an illuminated (bright)
image in the background.
The phase-contrast microscope produces high contrast images when using a
transparent specimen more so those of microbial cultures, thin tissue fragments, cell
tissues, and subcellular particles.
BIOLOGICAL TECHNIQUES 9
The principle behind the working of the phase-contrast microscope is the use of an
optical method to transform a specimen into an amplitude image, that’s viewed by the
eyepiece of the microscope.
The PCM can be used to view unstained cells also known as the phase objects, which
means that the morphology of the cell is maintained and the cells can be observed in
their natural state, in high contrast and efficient clarity. This is because if the
specimens are stained and fixed, they kill most cells, a characteristic that is uniquely
undone by the brightfield light microscope.
The shifts that occur during light penetration, become converted to changes in
amplitude which causes the image contrast.
Coupled with contrast-enhancing elements such as fluorescence, they produce better
visuals of the specimens’ image.
The instrumentation of the Phase Contrast Microscope is based on its light pathways from
receiving the source of light to the visualization of the image.
Phase-contrast microscopy is basically a specially designed light microscope with all the
basic parts in addition to which an annular phase plate and annular diaphragm are fitted.
BIOLOGICAL TECHNIQUES 10
This thick or thin area in the phase plate is called the conjugate area.
The phase plate is a transparent disc.
With the help of the annular diaphragm and the phase plate, the phase contrast is
obtained in this microscope.
This is obtained by separating the direct rays from the diffracted rays.
The direct light rays pass through the annular groove whereas the diffracted light rays
pass through the region outside the groove.
Depending upon the different refractive indices of different cell components, the
object to be studied shows a different degree of contrast in this microscope.
Limitations
Phase-contrast condensers and objective lenses add considerable cost to a microscope,
and so phase contrast is often not used in teaching labs except perhaps in classes in
the health professions.
To use phase-contrast the light path must be aligned.
Generally, more light is needed for phase contrast than for corresponding bright-field
viewing, since the technique is based on the diminishment of the brightness of most
objects.
BIOLOGICAL TECHNIQUES 11
Fluorescence Microscope: Principle, Types and Applications
1. Light source: Xenon arc lamp or mercury-vapor lamp are common; power LED and
lasers are used in more advanced forms.
2. A set of optical filters: Optical filters include a set of a compatible excitation filter,
emission filter, and dichroic beam splitter;
An excitation filter selects the wavelengths to excite a particular dye within
the specimen.
A dichroic beam splitter/ dichroic mirror reflects light in the excitation
band and transmit light in the emission band, enabling the classic
epifluorescence incident light illumination.
An emission filter serves as a kind of quality control by letting only the
wavelengths of interest emitted by the fluorophore pass through.
3. Darkfield condenser: It provides a black background against which the fluorescent
objects glow.
The filters are often plugged in together in a filter cube (compound microscopes) or in a flat
holder (mainly stereo microscopes).
BIOLOGICAL TECHNIQUES 12
To the observer, the background is dark, as there is no visible light and only the labelled
specimen (cells, microorganisms etc.) appear bright (fluoresce).
There are various types of fluorescence microscopes. Some of the common types are:
1. Detection of acid-fast bacilli (AFB) in sputum or CSF when stained with auramine
fluorescent dye.
BIOLOGICAL TECHNIQUES 13
2. Detection of Trichomonas vaginalis, intracellular gonococci, and other parasites when
stained by acridine orange.
3. In immunodiagnosis of infectious diseases, using both direct and indirect antibody
techniques.
Polarizing Microscope
This microscope differs from others because it contains the following components:
A polarizer is a filter that only allows specific light waves or vibrations to pass through it and
focus them in a single plane.
BIOLOGICAL TECHNIQUES 14
An analyzer, mainly used as a second polarizer located above the sample, determines the
quantity and the direction of the light that illuminates a sample.
Due to the use of these filters, the polarized light waves vibrate in one single direction,
instead of the normal ones that vibrate in random directions.
In this way the polarized light is more concentrated and then more efficient to the study of
minerals, for example.
By changing the relationship of the polarizer and the analyzer, it’s possible to determine the
amount of absorbance, reflection and refraction of the light through the microscope.
Pathway of Light
The light passes through a polarizing filter called the polarizer (the polarizer is fixed in an
east to west vibrational way, but it can be rotated if necessary. There is one more
polarizing filter called the analyzer. It is usually situated above the objectives and can be
moved in and out of the optical path).
Passes through the birefringent specimen. The polarizer is usually fixed in an east to west
vibrational direction, but it can be rotated as required. There is one more polarizing filter
called the analyzer. It is usually situated above the objectives and can be moved in and
out of the optical path.
BIOLOGICAL TECHNIQUES 15
Applications of Polarized Light Microscopy
In polarized light microscopy, plane polarized light is passed through a double refracting
material and then collected using a second polarizing filter to generate a high-contrast image.
This technique finds application in several fields, such as medicine, basic biology, industry,
and to study rock minerals.
Medical Applications
Gout diagnosis
Gout occurs because of the deposition of urate crystals in the synovial fluid of the joints
which causes inflammation and pain. Polarized microcopy is used to examine synovial fluid
for the diagnosis of gout. Urate crystals causing gout have negative elongated optical
features, while pyrophosphoric acids which cause pseudo-gout have positive optical features.
These differences in the crystal direction and the interference colour on polarized light
microscopy are used to differentiate these crystals.
Amyloid protein examination
Amyloid proteins are created by abnormal metabolism of proteins which leads to their
aggregation within cells. These proteins may be deposited in various organs, such as the
spleen, liver, kidney, brain among others. These aggregates are not observed in normal cells.
Using polarized light, these amyloid structures can be visualised. The presence of amyloid
proteins is ascertained by the appearance of a bright green color on polarization light
microscopy.
Examination of Rocks
Polarized light microscopy can be used to examine rock structures and their optical
characteristics. This method can also be used to identify minerals inside rocks. Two methods
are used for this purpose.
BIOLOGICAL TECHNIQUES 16
this method the structure of the rock is destroyed. The advantage is that it does not require the
preparation of thin rock sections.
Applications in Industry
Liquid crystals
Liquid crystals are materials with properties in between liquids and solids. Polarizing
microscopes are used to detect peculiar optical patterns and phase defects in liquid crystals.
They can also be used to determine if a crystal is optically positive or negative. Liquid crystal
retardation can also be measured using polarized microscopes.
Macromolecular materials
Spherulites are transparent, double refractive materials of spherical shape, belonging to the
class called macromolecular crystals. Polarized microscopes can be used to determine their
density and size which in turn determines the strength and transparency.
Food chemicals
Polarized microscopes can be used to determine the properties of emulsions of butter and
cream as they possess optical anisotropy. Thus, using this method, any deviations in the
emulsion conditions or impurities can be determined.
Glass and ceramics
Polarized microscopy can be used to determine the quality of and defects in glass and
ceramics by identifying their colour, shape, diffraction index, and crystal impurities.
Metals
Metal inspection for composition, surface impurities and properties is possible using
polarizing microscopy on a polished metal sample.
Important Applications
BIOLOGICAL TECHNIQUES 17
CONFOCAL MICROSCOPE
A confocal microscope, on the other hand, uses light emitted by a laser for fluorescence
emission. Apart from the different light sources, the manner in which light is transmitted is
different between the two techniques.
BIOLOGICAL TECHNIQUES 18
In a confocal microscope, a laser system acts as the excitation source. As such, it emits a
coherent light which passes through a pinhole aperture situated at the conjugate plane before
reaching the dichromatic mirror. The laser is then reflected by the mirror and directed
towards the specimen in a defined focal plane where a secondary fluorescence is emitted.
Here, it is worth noting that like in widefield fluorescence microscopy, the confocal principle
may also employ the use of filters used in fluorescence microscopy (an excitation filter as
well as a fluorescence barrier filter). Here, these components serve similar functions to those
found in wide-field fluorescence microscopy. For this reason, the technique is sometimes
referred to as epi-illumination scanning confocal microscopy.
In a confocal microscope set-up, the scan head is at the heart of the system.
Components:
Apart from the laser sources in confocal microscopy, the pinhole apertures are some of the
most important parts of the microscope. The first pinhole aperture (light source pinhole
aperture/illuminating aperture) is located between the light/laser source and mirror.
Also known as a spatial filter pinhole, this pinhole is conveniently incorporated into the beam
expander which helps produce a uniform illumination beam. Typically, the ideal size of this
aperture is relatively large compared to the size of confocal aperture needed to achieve true
confocal operation.
Light from this aperture is then reflected by the mirror and directed to the sample/specimen
which in turn, produces the secondary fluorescence. From the specimen, the secondary
fluorescence is first collected by the objective lens before reaching the mirrors (galvanometer
mirrors) where it is descanned (fluorescence emission passes through the galvanometer
mirror system towards the detector).
From here, the light may pass through emission filters (barrier filters) and consequently reach
the second pinhole aperture (confocal aperture). Apart from the barrier filter, this aperture
plays an important role in excluding out-of-focus fluorescence signals (emissions that do not
originate from the focal plane) to ensure that only the signals from the illuminated spot enter
the detector.
BIOLOGICAL TECHNIQUES 19
It is worth noting that in this set-up, the whole sample is not illuminated at once.
Rather, the laser light is controlled in a manner that ensures that only a given spot at a
specified depth within the specimen is illuminated.
As a result, fluorescent light is only emitted from this point. The out-of-focus signals
from the features located above/below the focal plane are excluded from passing through the
aperture thus only allowing a small fraction of light to pass through.
By rejecting the out-of-focus and stray light, the pinhole contributes to the high
signal-to-noise ratio of the images produced.
Given that the image is reconstructed point by point using this technique, it cannot be
observed through the eyepiece because it does not exist as a real image.
Apart from the differences in the working principles of the two techniques,
differences can also be identified in their strengths and limitations. For instance, fluorescence
microscopy is very sensitive which allows for the detection of single-molecules. Moreover,
unique optical properties of molecules contribute to high specificity among these
microscopes.
With regards to confocal microscopy, one of the biggest advantages is that it's
possible to control the depth of field by serially producing thin optical sections of thick
specimens. By obtaining optical slices from increasing depth of the sample, it becomes
possible to produce a 3D image of the sample.
BIOLOGICAL TECHNIQUES 20
In fluorescence microscopy, on the other hand, images of samples that are over 5
micrometers in thickness appear blurry (indistinct) given that some parts of the sample tend
to be outside the focal plane. Therefore, when it comes to visualizing thicker specimen,
confocal microscopy is the superior technique.
Specific wavelengths are used to excite the specimen and produce fluorescence
By eliminating lateral interference, the technique is able to improve image contrast
Light is collected from a single focal plane
Applications:
Confocal microscopy is broadly used to resolve the detailed structure of specific objects
within the cell. Similar to widefield fluorescence microscopy, various components of living
and fixed cells or tissue sections can be specifically labeled using immunofluorescence, for
example, and then visualized in high resolution.
As a distinctive feature, confocal microscopy enables the creation of sharp images of the
exact plane of focus, without any disturbing fluorescent light from the background or other
regions of the specimen. Therefore, structures within thicker objects can be conveniently
visualized using confocal microscopy. Furthermore, by stacking several images from
different optical planes, 3D structures can be analyzed. The sample penetration depth is
limited, however, when using confocal microscopy. Thicker objects, like large spheroids,
organoids, tissue, and small animals, should instead be optimally imaged using two-photon
microscopy or LSFM.
Fluorescence In Situ Hybridization
Preparation of target DNA: DNA of metaphase or interphase cells are denatured into
single-stranded DNA
BIOLOGICAL TECHNIQUES 21
A DNA probe, corresponding to a specific chromosomal DNA sequence is labeled
with a specific fluorophore
Hybridization: Target DNA and the labeled DNA sequence are hybridized in situ to
fixed metaphase or prometaphase chromosome spreads on a glass slide
Each probe has the possibility of hybridizing specifically to two sister chromatids.
The probe, marking a specific sequence of the chromosome is then visualized
Labeling
It is possible to either label the probe directly or indirectly. Direct labeling involves a labeled
and modified nucleotide (often 2' deoxyuridine 5' triphosphate), which is directly
incorporated into the probe. In deoxyuridine 5' triphosphate), which is directly incorporated
into the probe. In indirect labeling, the DNA is labeled with a fluorophore to make the signal
visible (not being incorporated into DNA). Indirect labeling can involve e.g. a hapten
Fig. 1 Scheme of the principle of the FISH experiment to localize a gene in the nucleus.
FISH is useful, for example, to help a researcher identify where a particular gene falls within
an individual's chromosomes.
Here'showitworks: Make a probe complementary to the known sequence. When making the
BIOLOGICAL TECHNIQUES 22
probe, label it with a fluorescent marker, e.g. fluorescein, by incorporating nucleotides that
have the marker attached to them.
Wash off the excess probe and observe the chromosomes under a fluorescent microscope.
The probe will show as one or more fluorescent signals in the microscope, depending on how
many sites it can hybridize to.
Fig. 2 The five basic steps of FISH. (Oliveira and French 2005)
FISH is widely used for several diagnostic applications: identification of numerical and
structural abnormalities, characterization of marker chromosomes, monitoring the effects of
therapy, detection of minimal residual disease, tracking the origin of cells after bone marrow
transplantation, identification of regions of deletion or amplification, detection of
chromosome abnormalities in non-dividing or terminally differentiated cells, determination of
lineage involvement of clonal cells, etc. Moreover it has many applications in research:
identification of non-random chromosome rearrangements, identification of translocation
molecular breakpoint, identification of commonly deleted regions, gene mapping,
characterization of somatic cells hybrids, identification of amplified genes, study the
BIOLOGICAL TECHNIQUES 23
mechanism of rearrangements. FISH is also used to compare the genomes of two biological
species to deduce evolutionary relationships.
Locus specific probes bind to a particular region of a chromosome. This type of probe is
useful when researchers have isolated a small portion of a gene and want to determine on
which chromosome the gene is located.
Alphoid or centromeric repeat probes are generated from repetitive sequences found in the
middle of each chromosome. Researchers use these probes to determine whether an
individual has the correct number of chromosomes. These probes can also be used in
combination with "locus specific probes" to determine whether an individual is missing
genetic material from a particular chromosome.
Whole chromosome probes are actually collections of smaller probes, each of which binds
to a different sequence along the length of a given chromosome. Using multiple probes
labeled with a mixture of different fluorescent dyes, scientists are able to label each
chromosome in its own unique color. The resulting full-color map of the chromosome is
known as a spectral karyotype. Whole chromosome probes are particularly useful for
examining chromosomal abnormalities, for example, when a piece of one chromosome is
attached to the end of another chromosome.
Probes Design, Labeling, Purification and Test: FISH probes are synthetic pieces of DNA
that couple with a fluorescent indicator, so that the chromosomes or genes that they bind to
can be directly visualized under our imaging analysis system. Our well-established standard
operating procedure allows efficient optimization of labeling a variety of fluorescent probes.
Also, we can provide experimental services to meet your special needs. Customized probes
are available as well. The choice of directly or indirectly labeled SpectrumOrange,
SpectrumGreen, or SpectrumAqua probes is dependent upon the use and combination of
other fluorophores in the FISH assay.
BIOLOGICAL TECHNIQUES 24
Whole chromosome painting probes (WPP)
Chromosome arm painting probes (APP)
Chromosome terminal band painting probes (TPP)
Chromosome enumeration probes (CEP)
Chromosome subtelomere probes (CSP)
Chromosome loci specific probes (CLP)
In Situ Hybridization: We can optimize the FISH hybridization conditions and provide a
full array of FISH services.
Prenatal Diagnosis: Our optimized prenatal diagnosis detection kits offer innovative
technologies and standard methods that are applied to the diagnosis of fetal disorders. Cancer,
Prenatal, and Biology Research usethis FISH.
Trisomy
Turner Syndrome
Trisomy X
XYY Syndrome
DiGeorge Syndrome
Triploidy
Cancer Diagnosis and Prognosis: Many cancer diagnosis testing kits are available in our
company. You can also custom other cancer diagnosis probes according to your needs.
Bladder Cancer
Breast Cancer
Cervical Cancer
Chronic Lymphocytic Leukemia
Chronic Granulocytic Leukemia
BIOLOGICAL TECHNIQUES 25
Multiple Myeloma
Advantages
Simple, easy, fast and repeatable
Sensitive
Competitive price
Easy to process multiple slides simultaneously
High quality
Transmission Electron Microscope (TEM)
The working principle of the Transmission Electron Microscope (TEM) is similar to the light
microscope. The major difference is that light microscopes use light rays to focus and
produce an image while the TEM uses a beam of electrons to focus on the specimen, to
produce an image.
Electrons have a shorter wavelength in comparison to light which has a long wavelength. The
mechanism of a light microscope is that an increase in resolution power decreases the
wavelength of the light, but in the TEM, when the electron illuminates the specimen, the
resolution power increases increasing the wavelength of the electron transmission. The
wavelength of the electrons is about 0.005nm which is 100,000X shorter than that of light,
hence TEM has better resolution than that of the light microscope, of about 1000times.
This can accurately be stated that the TEM can be used to detail the internal structures of the
smallest particles like a virion particle.
BIOLOGICAL TECHNIQUES 26
Electron gun
This is the part of the Transmission Electron Microscope responsible for producing
electron beams.
Electrons are produced by a cathode that is a tungsten filament that is V-shaped and it
is normally heated. The tungsten filament is covered by a control grid known as a
Wehnelt cylinder made up of a central hole which lies columnar to the tube. The
cathode lies on top of or below the cylindrical column hole. The cathode and the
control grid are negatively charged with an end of the anode which is disk-shaped that
also has an axial hole.
When electrons are transmitted from the cathode, they pass through the columnar
aperture (hole) to the anode at high voltage with constant energy, which is efficient
for focusing the specimen to produce an accurately defined image.
It also has the condenser lens system which works to focus the electron beam on the
specimen by controlling the energy intensity and the column hole of the electron gun.
The TEM uses two condenser lenses to converge the beam of electrons to the
specimen. The two condenser lens each function to produce an image i.e the first lens
which has strong magnification, produces a smaller image of the specimen, to the
second condenser lens, directing the image to the objectives.
Image-Recording System
Its made up of the fluorescent screen used to view and to focus on the image. They
also have a digital camera that permanently records the images captured after
viewing.
They have a vacuum system that prevents the bombardment or collision of electrons
with air molecules disrupting their movement and ability to focus. A vacuumed
system facilitates the straight movement of electrons to the image.
The vacuumed system is made up of a pump, gauge, valves and a power supply.
The image that is formed is called a monochromatic image, which is greyish or black
and white. The image must be visible to the human eye, and therefore, the electrons
are allowed to pass through a fluorescent screen fixed at the base of the microscope.
BIOLOGICAL TECHNIQUES 27
The image can also be captured digitally and displayed on a computer and stored in a
JPEG or TIFF format. During the storage, the image can be manipulated from its
monochromatic state to a colored image depending on the recording apparatus eg use
of pixel cameras can store the image in color.
The presence of colored images allows easy visualization, identification, and
characterization of the images.
From the instrumentation described, the working mechanism is a sequential process of the
parts of the TEM mentioned above. To mean:
A heated tungsten filament in the electron gun produces electrons that get focus on the
specimen by the condenser lenses.
Magnetic lenses are used to focus the beam of electrons of the specimen. By the
assistance offered by the column tube of the condenser lens into the vacuum creating
a clear image, the vacuum allows electrons to produce a clear image without collision
with any air molecules which may deflect them.
On reaching the specimen, the specimen scatters the electrons focusing them on the
magnetic lenses forming a large clear image, and if it passes through a fluorescent
screen it forms a polychromatic image.
The denser the specimen, the more the electrons are scattered forming a darker image
because fewer electron reaches the screen for visualization while thinner, more
transparent specimens appear brighter.
The specimen to be viewed under the TEM must undergo a special preparation technique to
enable visualization and creation of a clear image.
Electrons are easily absorbed and easily scattered on solid elements, showing poor
visualization for thick specimens. And therefore, very thin specimens are used for
BIOLOGICAL TECHNIQUES 28
accurate and clear visualization forming a clear image as well. The specimen should
be about 20-100nm thin and 0.025-0.1nm diameter, as small as that of a bacterial cell.
Thin specimens allow interaction with electrons in a vacuumed space, are able to
maintain their innate structure.
To get thin slice specimens, the specimen is first fixed on a plastic material with
glutaraldehyde or osmium tetraoxide. These chemical agents stabilize the structure of
the cell and maintain its originality. The addition of an organic solvent like alcohol
such as ethanol will dehydrate the cell completely for embedding the specimen to the
plastics.
The specimen is then permeated by adding an unpolymerized liquid epoxy plastic
making it hardened like a solid block. This is where thin sections are cut from using a
glass knife with a piece of special equipment known as an ultramicrotome.
The specimen is then stained appropriately (with the appropriate stain) for the uniform
scattering of electrons. The thin sections are then soaked in heavy metallic elements
such as lead citrate and uranyl acetate allowing the lean and aluminum ions to bind to
the cell structures. This forms an opaque layer against the electrons on the cell
structures to increase contrast.
The stained thin sections are then mounted on copper grids for viewing.
The primary staining techniques that are applied for viewing under the TEM is
Negative staining coupled with heavy metallic elements coating. The metallic coating
scatters electrons which appears on the photographic film while uncoated sections and
used to study bacterial, viral cell morphologies and structures.
Freeze-itching treatment:
To reduce the possible dangers of artifacts, freeze-itching is used especially for the treatment
of microbial cells, unlike chemical fixation, dehydration, and embedding, where most
specimens get contaminated.
Microbial cell organelles undergo special treatment known as Freeze-itching whereby
the specimens are prepared with liquid nitrogen and then warmed at -100°C in a
vacuum chamber.
The sections are then cut with a precooled knife in liquid nitrogen at -196°C. After
warming up the sectioned specimen in a high vacuum for about 2 minutes, it can then
coated ith platinum and carbon layer forming replicas.
These are then be viewed under the TEM displaying more detailed internal structures
of the cell in 3D.
This step of treatment with Liquid nitrogen is known as freeze-itching.
1. It has a very powerful magnification of about 2 million times that of the Light
microscope.
2. It can be used for a variety of applications ranging from basic Biology to
Nanotechnology, to education and industrial uses.
3. It can be used to acquire vast information on compounds and their structures.
BIOLOGICAL TECHNIQUES 29
4. It produces very efficient, high-quality images with high clarity.
5. It can produce permanent images.
6. It is easy to train and use the Transmission Electron Microscope
LIMITATIONS
1. Generally, the TEMs are very expensive to purchase
2. They are very big to handle.
3. The preparation of specimens to be viewed under the TEM is very tedious.
4. The use of chemical fixations, dehydrators, and embedments can cause the dangers of
artifacts.
5. They are laborious to maintain.
6. It requires a constant inflow of voltage to operate.
7. They are extremely sensitive to vibrations and electro-magnetic movements hence
they are used in isolated areas, where they are not exposed.
8. It produces monochromatic images, unless they use a fluorescent screen at the end of
visualization.
Advantages of SEM
It gives detailed 3d and topographical imaging and the versatile information.
This works very fast.
Modern SEMs allow for the generation data ni digital form.
Most SEM samples require minimal preparation actions.
They are easy to operate and has user-friendly interfaces.
They are used in a variety of industrial applications to analyze surfaces of solid
objects.
Some modern SEMs are able to generate digital data that can be portable.
It is easy to acquire data from the SEM, within a short period of time of about 5
minutes.
BIOLOGICAL TECHNIQUES 30
Applications of the Scanning Electron Microscope (SEM)
It is used in a variety of fields including Industrial uses, nanoscience studies, Biomedical
studies, Microbiology
1. Used for spot chemical analysis in energy-Dispersive X-ray Spectroscopy.
2. Used in the analysis of cosmetic components which are very tiny in size.
3. Used to study the filament structures of microorganisms.
4. Used to study the topography of elements used in industries.
Disadvantages
SEMs are expensive and large.
Special training is required to operate an SEM.
SEMs are limited to solid samples.
SEMs carry a small risk of radiation exposure associated with the electrons that scatter
from beneath the sample surface.
SEM Properties
The Scanning Electron Microscope developed by professor Dr. Charles Oatlev with the
assistance of graduate students in the 1950s, are one of the three types of electron
microscopes (EM).
Electron microscopes utilize the same basic principles as light microscopes, but focus beams
of energetic electrons rather than photons, to magnify an object.
BIOLOGICAL TECHNIQUES 31
In addition, SEMs require a stable power supply, vacuum and cooling system, vibration-free
space and need to be housed in an area that isolates the instrument from ambient magnetic
and electric fields.
The process begins with an electron gun generating a beam of energetic electrons down the
column and onto a series of electromagnetic lenses.
The coils are adjusted to focus the incident electron beam onto the sample; these adjustments
cause fluctuations in the voltage, increasing/decreasing the speed in which the electrons come
in contact with the specimen surface.
Controlled via computer, the SEM operator can adjust the beam to control magnification as
well as determine the surface area to be scanned.
The beam is focused onto the stage, where a solid sample is placed. Most samples require
some preparation before being placed in the vacuum chamber.
Of the variety of different preparation processes, the two most commonly used prior to SEM
analysis are sputter coating for non-conductive samples and dehydration of most biological
specimens.
In addition, all samples need to be able to handle the low pressure inside the vacuum
chamber.
The interaction between the incident electrons and the surface of the sample is determined by
the acceleration rate of incident electrons, which carry significant amounts of kinetic energy
before focused onto the sample.
When the incident electrons come in contact with the sample, energetic electrons are released
from the surface of the sample. The scatter patterns made by the interaction yields
information on size, shape, texture and composition of the sample.
A variety of detectors are used to attract different types of scattered electrons, including
secondary and backscattered electrons as well as x-rays.
BIOLOGICAL TECHNIQUES 32
X-rays, emitted from beneath the sample surface, can provide element and mineral
information.
An atomic force microscope is a type of high resolution scanning probe microscope that has
a resolution that you can measure in fractions of a nanometer.
It was pioneered in 1986 by Nobel Prize Winner Gerd Binnig along with Calvin Quate and
Christoph Gerber.
One of the most important tools for imaging on the nanometer scale, Atomic Force
Microscopy uses a cantilever with a sharp probe that scans the surface of the specimen.
When the tip of the probe travels near to a surface, the forces between the tip and sample
deflect the cantilever according to Hooke’s law.
Atomic force microscopy will measure a number of different forces depending on the
situation and the sample that you want to measure.
As well as the forces, other microscopes can include a probe that performs more specialized
measurements, such as temperature.
The force deflects the cantilever, and this changes the reflection of a laser beam that shines
on the top surface of the cantilever onto an array of photodiodes. The variation of the laser
beam is a measure of the applied forces.
There are two primary modes of operation for an atomic force microscope, namely contact
mode and non-contact mode depending on whether the cantilever vibrates during the
operation.
BIOLOGICAL TECHNIQUES 33
In contact mode, the cantilever drags across the sample surface and it uses the deflection of
the cantilever to measure the contours of the surface.
To eliminate the noise and drift that can affect a static signal, low stiffness cantilevers are
used, but this allows strong attractive forces to pull the tip to the surface. To eliminate this
attraction, the tip is in contact with the surface where the overall force is repulsive.
In non-contact mode, the tip vibrates slightly above its resonance frequency and does not
contact the surface of the sample. Any long range forces, like van der Waals forces, decreases
the resonant frequency of the cantilever.
A feedback loop system helps to maintain the oscillation amplitude constant by changing the
distance from the tip to the sample. Recording the distance between the tip and sample at
each point allows the software to construct a topographic image of the sample surface.
Most samples will form a layer of moisture on the surface if stored at ambient conditions, and
this can make it difficult to measure the sample accurately.
If the probe tip is close enough to detect the short-range forces then it is close enough to stick
to the moisture. One way around this is tapping, or dynamic contact mode.
Tapping Mode
In tapping mode, the cantilever uses a piezoelectric element mounted on the top to oscillate it
at near to its resonance frequency with an amplitude of up to 200nm.
The forces cause the amplitude to decrease as the tip gets close to the surface, and the height
of the cantilever adjusts to keep the amplitude constant.
This tapping results in less damage to the sample than contact mode and is more accurate
than non-contact mode when moisture is present on a sample.
BIOLOGICAL TECHNIQUES 34
Applications
The AFM has been applied to problems in a wide range of disciplines of the natural sciences,
including solid-state physics, semiconductor science and technology, molecular
engineering, polymer chemistry and physics, surface chemistry, molecular biology, cell
biology, and medicine.
Applications in the field of solid state physics include
the identification of atoms at a surface,
the evaluation of interactions between a specific atom and its neighboring atoms, and
the study of changes in physical properties arising from changes in an atomic
arrangement through atomic manipulation.
In molecular biology, AFM can be used to study the structure and mechanical properties of
protein complexes and assemblies. For example, AFM has been used to
image microtubules and measure their stiffness.
In cellular biology, AFM can be used to attempt to distinguish cancer cells and normal cells
based on a hardness of cells, and to evaluate interactions between a specific cell and its
neighboring cells in a competitive culture system. AFM can also be used to indent cells, to
study how they regulate the stiffness or shape of the cell membrane or wall.
In some variations, electric potentials can also be scanned using conducting cantilevers. In
more advanced versions, currents can be passed through the tip to probe the electrical
conductivity or transport of the underlying surface, but this is a challenging task with few
research groups reporting consistent data (as of 2004).
AFM Advantages
The atomic force microscope is a powerful tool that is invaluable if you want to
measure incredibly small samples with a great degree of accuracy.
Unlike rival technologies it does not require either a vacuum or the sample to undergo
treatment that might damage it.
AFM Disadvantages
One of the major downsides is the single scan image size, which is of the order of
150x150 micrometers, compared with millimeters for a scanning electron microscope.
Another disadvantage is the relatively slow scan time, which can lead to thermal drift
on the sample.
BIOLOGICAL TECHNIQUES 35
Novel solutions are steadily improving these performance issues.
Diagram of AFM
Video Microscopes/videomicrography
Video microscopes provide a live feed image directly to a computer, TV or a LCD projector.
There are several different setups for video microscopes which differ mostly based on the
type of camera and the frames per second that the camera provides. The main goal for a video
microscope is typically a smooth real-time video image that does not jump and is fluid
Video Microscope
High quality live feed video microscopes utilize a microscope video camera that provides a
live video directly to a TV or LCD projector with a fast frame rate. Many video microscopes
offer high quality HD (high definjition) output images and are commonly used in teaching
environments. Video microscopes connect to the TV or projector through either an HDMI
cable or a VGA cable. Some of the more advanced HD cameras also offer image capture to a
microSD card. Video microscopes can have either a detachable camera or a built-in camera.
Digital Microscope With Video Capability
Many digital microscopes use a microscope digital camera that connects to the USB port on a
computer, and they offer video capture. However, the frame rate on these USB videos is not
as high quality as a video camera provides because the frames per second that are captured
are much lower. A microscope digital camera is a better choice when the primary focus is
capturing images and possibly making measurements, with only the occasional need for
BIOLOGICAL TECHNIQUES 36
video capture. Because of the lower frames per second on many microscope digital cameras,
the live image feed is often not as smooth as one offered by a video microscope. For
example, if you were soldering printed circuit boards under a microscope and needed to view
quick real-time movements, a digital USB camera would not be the best choice for a fast
frame rate.
This function is available on a growing number of DSLRs available on the market and allows
a real-time image to be displayed on the camera screen or, if coupled to a computer with
appropriate software, on the computer screen. Live View makes focusing much more reliable
than viewing through the camera eyepiece; most DSLRs do not have interchangeable focus
screens designed for finding accurate focus at high magnifications. The ‘refresh’ rate of Live
View is much lower than for video and therefore it is less useful for tracking and focussing
rapidly-moving objects under the microscope; in these instances coupling the camera to a
relay lens system with focusing telescope is to be preferred.
For the microscopist, silent Live View mode is desirable for higher magnification
photomicrography. The ability to record video. Several DSLRs released in the last year now
have the ability to digitally record high-quality video. This can be of great use to the
microscopist working with live specimens or dynamic processes such as crystallisation.
Reference :
https://microbenotes.com/compound-microscope-principle-instrumentation-and-
applications/
https://microbenotes.com/darkfield-microscopy/
https://microbenotes.com/phase-contrast-microscopy/
https://microbenotes.com/fluorescence-microscope-principleinstrumentation-
applications-advantages-limitations/
https://en.wikipedia.org/wiki/Polarized_light_microscopy
https://microbenotes.com/confocal-microscope/
https://www.creative-biolabs.com/fluorescent-in-situ-hybridization-FISH.html
https://geneticeducation.co.in/a-brief-introduction-to-fish-fluorescence-in-situ-
hybridization/
https://www.microscopyu.com/applications/fluorescence-in-situ-hybridization-
fish/fluorescence-in-situ-hybridization
https://www.wikilectures.eu/w/Fluorescence_in_situ_hybridization
https://en.wikipedia.org/wiki/Atomic_force_microscopy