G2 DC POWER CONTROLLER G2 DC Power Controller Features
• Modern, highly reliable high frequency
G2 POWER CONTROLLER FOR USE WITH IONPURE® CONTINUOUS
design with filtered output.
ELECTRODEIONIZATION MODULES
• Microprocessor controlled unit.
DC power controllers allow independent control of each Ionpure® CEDI module for • On-board diagnostics.
optimum system performance. Individual, pre-engineered boards reduce system • Universal AC input voltage
cost, spare part cost, and simplify power supply maintenance. and frequency.
The G2 DC Power Controller is a modern and highly reliable solid state rectifier • Constant current operation.
that will succeed the existing single-phase and three-phase Ionpure DC power • 0-5 VDC analog input for DC output
controllers. A single board takes the place of six previous models, and can be used current control.
with MX, LX and VNX Ionpure CEDI modules. • Analog output signals for remote
monitoring (PLC or DCS).
The new G2 Power Controller can be a retrofit for the single-phase 200VDC, • Automatic power stage shutdown
400VDC and 600VDC Ionpure PCBs. While it is compatible with the Ionpure protections:
DSP1, DSP1P, DSP8 and DSP8P display boards, advanced control and monitoring • Input over-voltage and under-voltage
features will be available with the release of the G2 display, employing Modbus • Unit over-temperature
RTU communication protocol. • Fail-safe DC power shutdown at open
“Remote on/off” interlock
• Additional protections:
• Input transient
• Output over-voltage
• Output over-current and short-circuit
• Several units can be fed from a single
transformer secondary.
• Multiple transformer secondary voltage
taps not required.
• Every board subjected to extended
factory burn-in.
For additional information on our G2
power components or CEDI modules call
+1 866.876.3340 or visit our website
at www.ionpure.com.
COMPLETE ELECTRICAL SPECIFICATIONS: LED Indicators:
AC Input: • Output ON
• Universal voltage: 220 - 660 VAC • Fault (e.g. high voltage, low voltage, communications
• Phase: single loss, etc.)
• Frequency range: 50/60 Hz ±3% Standards:
DC Output: • UL recognized component (US and Canada)
• Output voltage range: 30 - 600 VDC • CE
(maximum DC output voltage is approximately • RoHS compliance
90% of RMS AC input voltage at light load) Environmental Requirements:
• Output current range: 0 - 13.2 ADC
• Operating temperature: 0 – 50° C (32 – 122° F)
• Constant current mode of operation with selectable
• Storage temperature: -10 – 70° C (14 – 158° F)
DC output voltage limit
• Humidity: 0 - 95% (non-condensing)
Input and Output Connectors:
Physical Specifications:
• AC Input terminals
• Length: 6.12 in (155.58 mm)
• Analog input: 0 - 5VDC (for DC output current control)
• Width: 6.00 in (152.4 mm)
• Remote on/off interlock input (dry contact)
• Depth: 6.56 in (166.64 mm)
• DC output terminals (+, - and ground)
• Weight: 6.3 lb (2.9 Kg)
• Analog outputs: 0 - 5VDC (for voltage and
current monitoring)
• N.O. relay output (“Output ON” indicator) Ordering Information
Protections:
G2 Power Controller
IP-POWER600-G2
• Soft-start Model Number
• Selectable current range: 0 - 2.5, 0 - 4, 0 - 6.5, G2 Power Controller
W2T388687
0 - 10 and 0 - 13.2 Amps Order Number
• Transient voltage, over-voltage (+10% of Max),
over-temperature and short-circuit protections
• Shutdown at open interlock All current Ionpure® system display boards are compatible.
Mechanical: • IP-DSP1
• IP-DSP8
• Touch-safe connectors
• IP-DSP1P
• On-board cooling fans. Ambient temperature lower
• IP-DSP8P
than 50° C (122° F) is required.
Note: Use ONLY LX patch cables IP-LXCABLE06,
IPLXCABLE10 or IP-LXCABLE16 for installation with
the above display units.