Parameters
Printing Date : July 29, 2020
J1000 File Name : 20161122120138.dwp
Parameters List
No. Name Setting Value Unit Default Setting
b1-01 Reference selection 0- 1
b1-03 Stopping method 1- 0
b2-02 DC injection current 25 % 50
b2-03 DC injection time at start 0.50 sec 0.00
C1-01 Acceleration time 1 0.5 sec 10.0
C1-02 Deceleration time 1 0.5 sec 10.0
C1-03 Acceleration time 2 0.5 sec 10.0
C1-04 Deceleration time 2 0.5 sec 10.0
C1-09 Fast-Stop Time 0.0 sec 10.0
C2-03 S-Curve Characteristic at Decel Start 0.50 sec 0.20
C2-04 S-Curve Characteristic at Decel End 0.50 sec 0.00
C4-01 Torque compensation gain 1.50 - 1.00
d1-01 Frequency reference 1 75.00 Hz 0.00
d1-02 Frequency reference 2 40.00 Hz 0.00
d1-03 Frequency reference 3 20.00 Hz 0.00
d1-04 Frequency reference 4 40.00 Hz 0.00
d1-05 Frequency reference 5 21.00 Hz 0.00
d1-06 Frequency reference 6 20.00 Hz 0.00
d1-07 Frequency reference 7 55.00 Hz 0.00
d1-08 Frequency reference 8 60.00 Hz 0.00
d1-17 Jog frequency reference 16.00 Hz 6.00
d2-02 Frequency reference lower limit 1.0 % 0.0
E1-04 Max. output frequency 75.0 Hz 50.0
E1-07 Mid output frequency 5.0 Hz 2.5
E1-08 Mid output frequency voltage 32.0 VAC 16.0
E1-10 Min. output frequency voltage 18.0 VAC 12.0
E2-03 Motor no-load current 1.50 A 1.20
H1-03 Terminal S3 function selection 0003 - 0024
H1-04 Terminal S4 function selection 0004 - 0014
H1-05 Terminal S5 function selection 0005 - 0003
L1-02 Motor Overload Protection Time 0.1 min 1.0
o2-09 Initialize mode selection 2- 0
Page 1/ 1