PN-DNET/PN-ANET Tools Software

First
Thank you for your purchase of the company's Ethernet network communication modules
Before setting up the product, please note the following precautions:
1.This product power supply DC 10 ~ 30V, suggested the use of the 24Vdc power supply。
2.Make sure the power pin and polarity, and terminals and the power cord does locking。
3.To avoid the site noise interference, the signal input and output to recommend the use of
the isolation signal lines。

Wiring
(HUB/SWITCH)
COMPUTER

DC 10~30V
POWER
+ -

Software Installation and Downloads


Configure the software with the goods attached to the product packaging, if not, can also download
the site http://www.csec.com.tw, or to link with the Company or the dealer business。

Software Installation
(1) Install the software in the computer
(Support WINDOWS XP/VISTA/WIN 7)
(2) After installing the software,click it 2 times.
Application window will appear as

1
Note
1.Module default:IP address:10.0.0.1; Gateway=10.0.0.1;
Submask=255.0.0.0;DHCP=Disable
2.The first installation of this software, insert the Windows firewall and anti-virus
software to close
3.Click "Search" button to search for modules on the network
4.Double-click the search module, and enter the default password "00000000"

Screen instructions
File : The contents of the drop-down menu “EXIT”
Tool : The contents of the drop-down menu as below.
Search : The program will search the connected Enterhnet
converter automatically
(Note: the converter and the PC must in the same domain)
Ping Remote Ethernet Decive:
(Manual):After typing the IP address in the window and press PING,
you can know whether the equipment works
comes from the remote I/O module
Call up the operation screen of Terminal emulation to execute the
request / response command .
Firewave Updata : Update firmware
The contents of the drop-down menu as below.
TCP/IP Timeout: Time range of sending/ response signal can be set
Scan Rate:Settable range
operation guide can be found here

Tool Bar

EXIT: Exit the program


Terminal: Terminal emulation
Search: Search EDAM module
Ping: Manual IP location
Monitor: Monitor the Stream/Event Data

List:

MoudleIP: Sort by moudle IP


MoudleID: Sort by module ID
MoudleNO: Sort by module number

2
Network Setting
The Windows software will automatically search for a connected Ethernet
converter and displays status of the converter as shown below, the user can do
on demand parameter settings, such as IP addresses, passwords ... etc.

Module IP
Media Access Control Address.This is also called Ethernet address and needs no
further configuration。

IP Address, Subnet Mask, and Default Gateway:


(default 10.0.0.1, 255.0.0.0 and 0.0.0.0)
Please do it according to your network settings, make the first three levels in
the same IP within the group, but make sure IP is not re-use, otherwise it will
not connect

Allow you to get IP address from the DHCP servo without setting IP address
by manual. DHCP is default enabled

Login through a web browser to allow monitoring and remote control I / O, on


by default

Each module must has a unique ID number to be identified when the DHCP enabled, because you
would not know the module IP address when DHCP enabled, but if with the different ID number. You
cancall provided function call(TCP_GetIPFromID) to get correct IP address for each ID number

Allow you to change the password of the module,default:00000000

Set Stream /Event data Destination set time interval for sending stream
IP(default all disabled) data(default:1sec)

TEST
Configure Input or output channel Set the display value and state value

3
In order to meet the remote monitoring and maintenance requirements, the converter does not only
apply to networks in the region as well as from the Internet or Intranet. Therefore, no matter how far
the user can clear pine configuration.
Select project tools \ adds remote, in the function menu or clicking the button will show the following
figure. Then, type a specific IP address, and click "Ping" button. If the communication is successful,
click on the "Add" add to the tree display area of the Ethernet.
Note:
There are several conditions before joining
system remote converter, you need to confirm。 192 . 168 . 0 . 125

(1) Be sure the specific IP is existed and available.。


(2) Be sure to complete the network linkage for both sides.。
(3) Be sure to adjust the best timing of timeout setting。
(4) Even you are not sure whether the communication is
workable or not, there is also a “Ping” function for
testing the network connection.

Security settings
Converter provides a password security function,
before entering the set will first be asked to enter
a password before entering the set parameters.。
(default:00000000)

After login, the menu at the bottom of ,


do password change, in order to achieve
security.

Terminal emulation
Converter provides terminal emulation features,
in press After the window appears as

shown at right, the user can choose ASCII or


hexadecimal ModBus, issue commands and
receive responses to do the action.

4
Data Stream Configuration

In addition to the TCP/IP communications protocol, UDP communication protocol converter support long-
term, broadcast data to a specific computer, click Options on the data flow, and then configure the time
interval and a specific IP address, you can receive data from a specific module. The UDP streaming data
function to broadcast up to 8 computer host, you can define the time interval from the 50ms~7 days

Data Stream Monitoring


After you complete the configuration, you can select in the function bar click icon appears next
figure displays.
Select translator wanted to read data from IP addresses, and then click the "start" button. Program will
begin receiving this on the display of data

After entering the parameters setting, the menu


"TEST", the user can review the information from the
program screen

Location:Standard Modbus address. Converter for


each I/O Modbus I/O display image address channel.
And each addresses easy to index the HMI or OPC
Server

Channel:Indicate the channel number of digital I/O


module

Type:Data Type of the I/O channel. The data type of


Digital I/O modules is always “Bit”。

Value:The current status on each channel of I/O


Module. The value of digital I/O modules could be “0”
(OFF) or “1”(ON)。

Mode:Describe the specific type of I/O modules. In


addition to monitoring the current DI/Do status, within
the window provides a graphical user interface. You
can read and modify the input status through the
indicator icon。

5
The digital input channels support counter and signal latch functions. Click the specific
channel, there will be four working modes for choosing.。

The new working mode setting will take


effective after click the “Update” button.

The digital output channels support pulse output and delay output functions. Click the
specific channel, there will be four working modes for choosing.。

6
Select Translator simulation input module, and select the "General settings" option, the user can read the
following from the practical information。

Location:Standard Modbus address.

Channel:the channel number

Type:Data type of the I/O channel. The data type of analog Input modules is always “word”。

Value:The current status on each channel of I/O modules. Windows Utility provides both decimal and
hexadecimal values used for different applications。

Input Type:Sensor types and measurement range of the specified module。

Provide users with more valuable information,


analog converter module design and
calculation capabilities, including various
channels maximum, minimum, and average.
Click on the "maximum" option, you will see
the history of each channel in the highest
value, until you press the "RESET" button

Click the Minimum value tab, you will see the


historical minimum values in each channel
unless to press the against “Reset” buttons.

7
Adjust the calibration accuracy of converter modules. There are several modules of the
calibration model: zero calibration, full measure of calibration, CJC calibration and
analog output calibration. Only for analog input and output modules can be calibrated.

Zero Calibration
1。Apply power to the module and let it warm up for 30
minutes.。
2。Make sure the module is correctly installed and
properly configured for the input range you want to
calibrate.。
3。Short channel 0 to GND by wire as short as possible。
4。Click the Execute button.。

Span Calibration
1。Follow the same procedure of zero calibration
2。Using high-precision power supply for calibration
voltage V +And V-type terminal block module。
3。and click the Execute button.。

There is serval range of each channel of analog


module. You should select properly type(range)
before apply to the your applications。

The new working mode setting will take


effective after click the “Update” button.

In addition, all analog channels to trigger the


alarm function allows you to configure high /
low limit. Once the value above or below the
limit of a particular channel, alarm status will be
output。

The new working mode setting will take effective


after click the “Update” button.

8
Website Login
Open a Web browser (take IE9.0 for example), in
the URL column, on the IP address converter。

EX:http://192.168.xx.xx ( Based on user defined in


the Module IP )
Recommended IE6.0 or later

Login Menu page appears, shown at right。


Type the Login password in the framework, and
then Send。
(Login password for the user as defined in Module Ip)

Password authentication before you can Login, the login screen as。
( For example,PN-ANET)

Channel : Channel number of analog input or digital output


Hi-Alarm : Analog channel High alarm status
Lo-Alarm : Analog channel low alarm status
Voltage: Voltage value of analog input channel
AI Type: Range of analog input channel
Status : Digital output status
DO Setting: Set digital output On or Off
Time interval: I/O status update time interval