HP PLUS TOWER

NITROGEN GENERATOR www.vicidbs.com

North America & South America contact: Europe, Asia, Africa, & Australia/Oceania contact:

VICI DBS USA VICI AG INTERNATIONAL


tel: +1 713-263-6970 tel: Int + 41 41 925-6200
fax: +1 713-263-6971 fax: Int + 41 41 925-6201
web: www.vicidbs.com web: www.vicidbs.com
2 | VICI DBS - HP PLUS TOWER NITROGEN GENERATOR

DESCRIPTION
The VICI DBS HP Plus Tower produces nitrogen by
®

utilizing a combination of filtration and pressure swing


adsorption (PSA) technology. Standard compressed IN
LE
T
R L)
air is filtered by high efficiency coalescing filters to AI E NN A
OV I O
T
ER P
remove all contaminants down to 5 micron. For ultra FI
LT (O

sensitive applications such as GC carrier and make-up 2


S G
IN
gas, units also include the additional heated catalyst A
CM MN
P S CO L
U OL IL
CO CO
module to ensure hydrocarbons are removed to <0.1
1 EN
ppm. The air then passes through two columns filled S
CM N
OG ET
TR UTL
S A LU M I
N O
with a proprietary blended carbon molecular sieve P CO
&
OW
FL R
E AT O
(CMS) which adsorbs O2, CO2 and moisture. These R
SU UL
ES EG
PR R
are desorbed to the atmosphere during the pressure
swing cycle leaving a supply of ultra pure nitrogen.

INCREASE EFFICIENCY RETURN ON INVESTMENT


A constant gas supply with a Payback period can be as short as 6 to
guaranteed purity, eliminates 12 months.
interruptions of analyses to change
cylinders and reduces the amount of
instrument re-calibrations required.
ENHANCE PERFORMANCE
Gas generators can be installed in the
IMPROVE SAFETY laboratory close to the instrument,
Nitrogen produced at low pressure eliminating the need for long gas lines
and ambient temperature, removes the from external cylinder supplies. A
need for high pressure cylinders. constant guaranteed high purity gas
supply improves stability and ensures
greater reproducibility of results.

FEATURES
Produces a continuous supply of high purity nitrogen | On-demand supply 24/7 | Flow rate: 200 to 4000
mL/min | Purity: up to +99.999% & <0.1 ppm THC | Pressure: up to 5 barg (75 psig) | Proprietary carbon
molecular sieve technology | 2-year complete product warranty | Easy to install, operate
and maintain

BENEFITS
Eliminates dangerous high pressure cylinders helping to keep your employees safer | Removes the
logistics, inconvenience, downtime and costs of a cylinder system | Flow capacity to match your specific
instrument demands | Ideal for all GC applications - stable baseline with increased sensitivity and
repeatability | Meets and exceeds the requirements for the most demanding GC applications | Superior
air purification with long life catalyst technology | Peace of mind | Improve your laboratory work flow and
productivity

APPLICATIONS
GC APPLICATIONS
• GC carrier and make-up gas • TGA & DSC
• ECD • Incubators
• ELSD
VICI DBS - HP PLUS TOWER NITROGEN GENERATOR | 3

MODELS & SPECS HP PLUS 500 HP PLUS 750 HP PLUS 1300 HP PLUS 4000
Flow mL/min 500 750 1300 4000
Purity +99.999% +99.99% +99%
Hydrocarbon purity n/a
(measured as methane)
Dewpoint oC (oF) -50 (-58)
Outlet pressure barg (psig) up to 5 max (75)
Inlet pressure barg (psig) 7 to 10 (100 to 160)
Actual inlet air requirement 11 (159.5) 12 (174) 16 (232.1) 24 (348.1)
litres @ 8 barg (psig)
Recommended compressor 22 (319.1) 24 (348.1) 32 (494.1) 48 (696.2)
air inlet @ 8 barg (psig)
Pressure drop barg (psig) 1.5 (22)
Inlet air quality Clean dry compressed air ISO8573-1:2010 Class 1.2.1
Technology Carbon molecular sieve
Warm up time minutes 60
LED indicators Power on/off, system ready, errors
Electrical supply 110-120V 60Hz / 220-240V 50 Hz
Power consumption watts 12
Noise level Minimal
Dimensions mm (in) 140W x 490H x 630D (5.5W x 19.3H x 24.8D)
Weight kg (lb) 17 (37.5)
Shipping dimensions mm (in) 770W x 590H x 410D (30.3W x 16.1H x 23.2D)
Shipping weight kg (lb) 20 (44)
Operating temp oC (oF) 15 to 35 (59 to 95)
Inlet connection 1/4” Compression
Outlet connection 1/8" Compression
Certification CE, FCC
4 | VICI DBS - HP PLUS TOWER NITROGEN GENERATOR

MODELS & SPECS HP PLUS HP PLUS HP PLUS HP PLUS HP PLUS


200 HC 500 HC 750 HC 1300 HC 4000 HC
Flow mL/min 200 500 750 1300 4000
Purity +99.999% +99.99% +99%
Hydrocarbon purity 0.1 ppm
(measured as methane)
Dewpoint oC (oF) -50 (-58)
Outlet pressure barg (psig) Up to 5 max (75)
Inlet pressure barg (psig) 7 to 10 (100 to 160)
Actual inlet air requirement 11 (159.5) 11 (159.5) 12 (174) 16 (232.1) 24 (348.1)
liters @ 8 barg (psig)
Recommended compressor 22 (319.1) 22 (319.1) 24 (348.1) 32 (494.1) 48 (696.2)
air inlet @ 8 barg (psig)
Pressure drop barg (psig) 1.5 (22)
Inlet air quality Clean dry compressed air ISO8573-1:2010 Class 1.2.1
Technology Carbon molecular sieve
Warm up time minutes 60
LED indicators Power on/off, system ready, errors
Electrical supply 110-120V 60Hz / 220-240V 50 Hz
Power consumption watts 270
Noise level Minimal
Dimensions mm (in) 140W x 490H x 630D (5.5W x 19.3H x 24.8D)
Weight kg (lb) 17 (37.5)
Shipping dimensions mm (in) 770W x 590H x 410D (30.3W x 16.1H x 23.2D)
Shipping weight kg (lb) 22 (49)
Operating temp oC (oF) 15 to 35 (59 to 95)
Inlet connection 1/4” Compression
Outlet connection 1/8" Compression
Certification CE, FCC

ORDERING INFORMATION (for best service, please call to discuss your application before placing your order).

HP PLUS 500 HP PLUS 4000 HP PLUS 750 HC


DB-N2T-500-EU 220V/50Hz DB-N2T-4000-EU 220V/50Hz DB-N2T-750-O-EU 220V/50Hz
DB-N2T-500-US 115V/60Hz DB-N2T-4000-US 115V/60Hz DB-N2T-750-O-US 115V/60Hz

HP PLUS 750 HP PLUS 200 HC HP PLUS 1300 HC


DB-N2T-750-EU 220V/50Hz DB-N2T-200-O-EU 220V/50Hz DB-N2T-1300-O-EU 220V/50Hz
DB-N2T-750-US 115V/60Hz DB-N2T-200-O-US 115V/60Hz DB-N2T-1300-O-US 115V/60Hz

HP PLUS 1300 HP PLUS 500 HC HP PLUS 4000 HC


DB-N2T-1300-EU 220V/50Hz DB-N2T-500-O-EU 220V/50Hz DB-N2T-4000-O-EU 220V/50Hz
DB-N2T-1300-US 115V/60Hz DB-N2T-500-O-US 115V/60Hz DB-N2T-4000-O-US 115V/60Hz

You might also like