TLM8 MODBUS/TCP
DIGITAL//ANALOG WEIGHT TRANSMITTER - 8 INDEPENDENT CHANNELS
DIGITAL
DESCRIPTION CODE
TLM8 MODBUS/TCP
Weighing system with 8 independent reading channels for load
cells.
The TLM8 transmitter allows to have same benefits and
performance of an advanced digital weighing system even using
analog load cells.
IP67 VERSION BOX (on request)
Omega/DIN rail mounting suitable for back panel or junction box.
Dimensions: 148x92x60 mm.
Backlit graphic LCD display, transmissive STN, white on blue,
128x64 pixel resolution, 60x32 mm visible area.
Five-key keypad for the system calibration.
TEST key for direct access to the diagnostic functions.
Extractable screw terminal boards.
INPUT/OUTPUT AND FIELDBUSES
Modbus/TCP device port that allows to exchange the main system
parameters with Modbus/TCP master.
8+3 PG9 cable glands-plugs 8+3 PVC end fittings
Current or voltage 16 bit analog output
RS485 serial port with ModBus RTU protocol, ASCII Laumas
bidirectional or continuous one way transmission.
5 relay digital outputs controlled by the setpoint values or via
protocols.
3 optoisolated PNP digital inputs: status reading via serial
communication protocols.
4 load cell dedicated inputs.
CERTIFICATIONS
OIML R76:2006, III class, 3x10000 divisions 0.2 μV/VSI
Re v. 00 de l 12/0 3/2 015
CERTIFICAZIONI AON
CERTIFICATIONS RICHIESTA
REQUEST
Initial verification (Legal Metrology)
UL Recognized component - Complies with the United States and Canada regulations
Complies with the Eurasian Custom Union regulations (Russia, Belarus, Kazakhstan)
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001:2008
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001:2004
www.laumas.com
TLM8 MODBUS/TCP
DIGITAL//ANALOG WEIGHT TRANSMITTER - 8 INDEPENDENT CHANNELS
DIGITAL
MAIN FUNCTIONS
8 independent channels for load cells: monitoring and direct 8 INDEPENDENT CHANNELS
management of the individual load cells connected. The screen shows the automatic standard operating mode and the
Digital equalization: the instrument allows to equalize the activation/deactivation status of individual channels to indicate the
connected load cells response, in a fast and reliable over time. presence/ absence of connection with load cells.
Load distribution synoptic analysis on 8 channels with archive
backups: storing, retrieving, printing.
Automatic diagnostics: the instrument is designed to store the
percentage value of load distribution for each channel. The
diagnostic function makes comparisons between the recorded
values and if a significant variation between the values is detected
during normal operation, the instrument displays an alarm
alternating with the weight value.
Depending on the weighing system type it’s possible to perform:
- Load automatic diagnostics: load distribution control in constant
barycentre systems (e.g. liquids silo). Auto mode: at each power-on, the instrument
- Automatic diagnostics on zero: check on load cells drift state automatically detects the status of the 8 channels.
(eg. silo, weighbridge, platformes). Active Channels: there is a connection with the load
Event log: data backups archive in chronological order of the cell.
last 50 events related to calibrations, zero settings, errors and
equalizations. The information can be stored, retrieved and Channel not active: no connection with the load cell.
printed.
Serial connection to the PLC (Master) via Modbus/TCP port
(slave) or via analog output.
LOAD DISTRIBUTION
RS485 serial connection up to 99 weight transmitters with line The TLM8 displays graphically the current load distribution on each
repeaters (up to 32 without line repeaters), PC/PLC, remote
display or printer. active channel.
Connection up to 16 load cells in parallel. Current
Digital filter and anti peak to reduce the effects of weight oscillation. Gross weight state
RS485 (Modbus RTU)/fieldbus transmission of the divisions for % of
the 8 independent reading channels.
distributed OFF
Theoretical calibration and real (with sample weights). load Channel
Tare weight zero setting. Channels not active
Automatic zero setting at power-on.
Gross weight zero tracking. Bar chart ERROR
Semi-automatic tare (net/gross weight) and predetermined tare. Connection
Semi-automatic zero. problem
Direct connection between RS485 and RS232 without converter.
Hysteresis and setpoint value setting.
The TLM8 displays graphically the load cells response signal in mV
for each active channel.
EQUALIZATION WITH JUNCTION BOXES DIGITAL EQUALIZATION
The equalization procedure with junction boxes and trimmer The TLM8 does not require the use of junction box, thanks to
requires more manual steps and over time it can undergo drift the support of 8 independent channels; furthermore the digital
phenomena over time, requiring subsequent repetitions of the equalizer function simplifies the procedure to a single step and it is
same procedure. free of drift over time.
1002 kg 1000 kg
998 kg 1000 kg
= LOAD CELLS
TLM8
TRANSMITTER EQUALIZATION kg kg
Re v. 00 de l 12/0 3/2 015
INDICATOR BOARD 1000 1000
PLATEFORM PLATEFORM
997 kg 1000 kg
1003 kg 1000 kg
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001:2008
UFFICIO VENDITE ITALIA: [email protected] • EXPORT SALES DEPARTMENT: [email protected] ISO 14001:2004
www.laumas.com
TLM8 MODBUS/TCP
DIGITAL//ANALOG WEIGHT TRANSMITTER - 8 INDEPENDENT CHANNELS
DIGITAL
CE-M version: 2014/31/UE-EN45501:2015-OIML R76:2006 Net weight zero tracking.
Weight subdivisions displaying (1/10 e). Calibration correction via keyboard is protected through seals for the
Three operation mode: single interval or multiple ranges (max 3) access to a setting jumper or installer password or hardware device.
or multi-interval (max 3). Alibi memory (option on request).
TECHNICAL FEATURES
Power supply and Consumption 12÷24 VDC ±10%; 5 W
Number of load cells • Load cells supply up to 16 (350 Ω) - 4/6 wires • 5 VDC/240 mA
Linearity • Linearity of the analog output <0.01% Full scale • <0.01% Full scale
Thermal drift • Thermal drift of the analog output <0.0005% Full scale/°C • <0.003% Full scale/°C
A/D Converter 8 channels - 24 bit (16000000 points)
Divisions (with measure range ±10 mV and sensitivity 2 mV/V) ±1000000 • 0,01 μV/d
Measure range ±39 mV
Load cell’s sensitivity ±7 mV/V
Conversion per second 600/s
Display range ±999999
Decimals • Display increments 0÷4 • x1 x2 x5 x10 x20 x50 x100
Digital filter • Conversion rate 0.006÷7 s • 5÷600 Hz
Relay digital outputs n. 5 - 115 VAC/150 mA
Optoisolated digital inputs n. 3 - 5÷24 VDC PNP
Serial ports RS485
Baud rate 2400, 4800, 9600, 19200, 38400, 115200 (bit/s)
16 bit = 65535 divisions. CURRENT: 0÷20 mA; 4÷20 mA (up to 300 Ω)
Analog output
VOLTAGE: 0÷10 V; 0÷5 V (min. 10 kΩ)
MODBUS/TCP port RJ45 10Base-T or 100Base-TX (auto-sensing)
Humidity (condensate free) 85%
Storage temperature -30°C +80°C
Working temperature -20°C +60°C
Relay digital outputs n. 5 - 30 VAC, 60VDC/150 mA
Working temperature -20°C +50°C
Power supply device marked “LPS” (limited power source) or “Class 2”
METROLOGICAL SPECIFICATIONS OF TYPE-APPROVED INSTRUMENTS
Applied standards 2014/31/UE - EN45501:2015 - OIML R76:2006
Accuracy class III or IIII
Maximum number of scale verification divisions 10000 (class III); 1000 (class IIII)
Minimum input signal for scale verification division 0.2 μV/VSI
Working temperature -10°C +40°C
OPTIONS ON REQUEST
DESCRIPTION CODE
Alibi memory OPZWALIBI
IP67 ABS waterproof box 190x190x130 mm
(4 fixing holes Ø4 mm; centre distance164x164 mm)
- transparent cover CASTLG
- transparent cover; 8+3 PG9 cable glands-plugs CASTLG8PG9
Re v. 00 de l 12/0 3/2 015
- transparent cover; 8+3 PVC end fittings CASTLG8GUA
- external keyboard CASTLGTAST
- external keyboard; 8+3 PG9 cable glands-plugs CASTLGTAST8PG9
- external keyboard; 8+3 PVC end fittings CASTLGTAST8GUA