Automatic Swing Door Drives en 144785
Automatic Swing Door Drives en 144785
Table of contents
ECturn, EMD,
TSA 160 NT
Foreword: GEZE swing door systems 4
Overview table 5
Types of installation 6
Automatic swing
door systems
Automatic swing door systems
For fire and smoke protection doors (F) 7
With integrated closing sequence control (IS) 7
With integrated closing sequence control for double-leaf fire and
smoke protection doors (F-IS) 8
With integrated closing sequence control for double-leaf doors, automatic doors
and door closer function (IS/TS) 8
For fresh air supply as well as doors in emergency exit routes (Invers) 9
For large and heavy doors, as well as frequently used doors (EN7) 9
Special area of application: Toilets for the disabled 10
Swing door drives
GEZE ECturn 11
GEZE Slimdrive EMD 21
GEZE TSA 160 NT 43
Accessories (Cover, mounting plate, link arm, guide rail with lever) 55
Operation 56
Actuation 57
Protection 59
Service Tools 64
The swing door systems For large and heavy doors, as well as frequently used doors from GEZE make it easier to pass through doors whenever
manual operation is too cumbersome or difficult. The outstanding features of the systems include reliability and safety, as well as a clear and
Automatic swing
door systems
modern design. GEZE implements building-specific solutions and guarantees planners maximum design freedom.
The electromechanical ECturn drive allows internal doors to be opened and closed gently and easily for barrier-free access.
Thanks to their uniquely small overall height of only seven centimetres, the drives in the Slimdrive range can be fitted almost invisibly to any
building architecture.
The electrohydraulic TSA range is the first choice for doors in frequently used areas. Durability and strength are the characteristics of this range.
DIN 18650
The industrial standard DIN 18650 was created to be able to guarantee operators and users of automatic doors optimum safety. GEZE swing
door systems with automatic function have been type-tested to DIN 18650 and certified.
2
2
1 = Drive
2 = Actuation
3 = Safeguarding
4 = Operation
ECturn, EMD,
TSA 160 NT
ECturn Slimdrive EMD TSA 160 NT
Automatic swing
door systems
Product features
GLS 850 mm
Leaf width (min.) 650 mm 690 mm
GST 750 mm
GLS 1400 mm
Leaf width (max.) 1100 mm 1400 mm
GST 1600 mm**
GLS – 1700-2500 mm
Hinge clearance on double-leaf doors 1470-2800 mm
GST – 1500-2800 mm
Electromechanical drive ● ●
Electrohydraulic drive ●
Functions
Automatic ● ● ●
Variants
For large and heavy doors, as well as frequently used doors (EN7) ●
Page 10 21 43
Note: The maximum possible leaf weight in relation to leaf width can be found in the chapter on areas of application (diagrams)!
The following diagrams show the installation possibilities for swing doors and the drives which can be used to realise this application.
Automatic swing
door systems
Notes
A door stopper is always required.
We recommend link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account.
Transom installation with guide rail Door leaf installation with guide rail Door leaf installation with link arm
1 = ECturn 1 = ECturn 1 = ECturn
2 = Slimdrive EMD 2 = Slimdrive EMD
3 = TSA 160 NT
4 = TSA 160 NT Z
5 = TSA 160 NT Invers
Transom installation with link arm Transom installation with guide rail Door leaf installation with guide rail
1 = ECturn 1 = ECturn 1 = ECturn
2 = Slimdrive EMD 2 = Slimdrive EMD
3 = TSA 160 NT
4 = TSA 160 NT Z Invers
Swing door systems for fire and smoke protection doors (F)
ECturn, EMD,
TSA 160 NT
Drive systems in the F variant are used to automatically open and close single-leaf fire protection doors. The usual types of impulse generator
can be used to actuate the drive. In addition to automatic opening and closing, fire protection doors can also be held open. In the event of a
Automatic swing
door systems
fire, an appropriate fire detection system must cancel the automatic function or any hold-open mechanism. Power supply to the mains cable
is interrupted via a mains switch-off board (F-accessory) and the drive retains the normal door closer function. This means that door closers
with automatic opening function in accordance with DIN 18263 Part 4 are a component part of hold-open systems and require official building
approval. Fire protection doors must meet the requirements of the DIBt guideline (Deutsches Institut für Bautechnik).
This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT
F swing door
Swing doors in the IS variant are always equipped with an integrated closing sequence control. The mechanical closing sequence control en-
sures that the fixed leaf closes first on double-leaf doors. The active leaf only closes once the fixed leaf has closed completely. The mechanical
closing sequence control also works without electricity and in the event of a power failure.
This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT
IS swing door
Swing door systems with integrated closing sequence control for double-leaf fire and smoke protection
doors (F-IS)
ECturn, EMD,
TSA 160 NT
Drive systems in the F-IS variant are used to automatically open and close double-leaf fire protection doors. A mechanical closing sequence
control is necessary for double-leaf fire protection doors, refer to the section on integrated closing sequence control (IS).
Automatic swing
door systems
This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT
Swing door systems with integrated closing sequence control for double-leaf doors, automatic doors
and door closer function (IS/TS)
With this variant for double-leaf swing door systems, the active leaf is automated with a swing door drive (TSA 160 NT), the fixed leaf is equip-
ped with a door closer (TS 160). Since the drive design is not interrupted, this system produces harmonious results, both in terms of function
and appearance. The preferred use for this swing door drive/door closer combination is when the active leaf is the one mainly moved. The
closing sequence control required for use on fire protection doors is also integrated in the drive housing. This guarantees that both door leaves
close in a controlled manner after they have been passed through. The fixed leaf can be held open by manually setting the programme switch
to “permanently open” and manually opening the door.
This variant can be achieved using the following drive series: TSA 160 NT IS/TS
Swing door systems for fresh air supply as well as doors in emergency exit routes (Invers)
ECturn, EMD,
TSA 160 NT
Inversely installed swing door drives are used on single and double-leaf single-action doors made of wood, plastic or steel. There is an elec-
trical closing sequence control available for double-leaf doors. Inversely installed drives are suitable for emergency exit routes and for fresh air
Automatic swing
door systems
opening systems for RWA systems. The doors are opened by spring force and closed by motor. This guarantees that the door will open safely
in the event of a power failure or fire alarm. An emergency power supply is no longer required.
This variant can be achieved using the following drive series: Slimdrive EMD and TSA 160 NT
Swing door systems for large and heavy doors, as well as frequently used doors (EN7)
This variant is a reliable solution for the automation of very large and heavy swing doors which are frequently used. Drives in the EN7 range
are suitable for leaf weights up to max. 310 kg and leaf widths up to 1600 mm. These drives are particularly suitable for homes for the elderly,
hospitals, shopping centres, schools or airports.
This variant can be achieved using the following drive series: TSA 160 NT EN7
Toilets for the disabled must be designed in such a way that people with all sorts of different handicaps can use the facilities without needing
help. GEZE swing door drives provide an indispensable service for this application, and guarantee a high level of convenience.
Automatic swing
door systems
Function description
The door opens automatically after the large-sized button on the outside of the toilet has been pressed, and closes automatically after the set
hold-open time has passed.
When the user presses the switchover inside the toilet cubicle, the “occupied” sign outside the toilet is activated and the telltale lamp on the
change-over switch comes on. At the same time, the large-sized button is deactivated on the outside and on the inside. This means the door
cannot be opened by third parties nor by the user by mistake. The door opener is supplied with current, preventing manual opening of the
door from outside. When the user leaves the toilet, he presses the switchover again. The “occupied” sign outside and the telltale lamp inside
both go off. The drive is actuated by pressing the large-sized OPEN DOOR button inside the cubicle, and the door opens immediately.
In the event of a power failure, the closed circuit current door opener releases and the user can leave the cubicle by pushing or pulling the
door open. The door can also always be opened from the inside by pressing the large-sized button, even when the system is still powered. In
emergencies, the door can be opened manually from the outside by means of a key or by actuating the emergency-off switch.
4
6
5
2
GEZE ECturn
ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1-leaf single-action internal doors
This extremely quiet electromechanical swing door drive meets the requirements of barrier-free construction. It makes life easier and more
convenient – particularly for people with mobility problems or little strength. Doors can comfortably be opened automatically, or opened
Automatic swing
door systems
manually and closed automatically. The GEZE ECturn can be operated both in low-energy mode and in automatic mode in accordance with
DIN 18650. In low-energy mode, the drive moves the swing door at reduced speed. The use of safety sensors to safeguard the system is only
necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be
safeguarded with safety sensors. An optional battery ensures maximum safety even in the event of a power failure. This swing door drive covers
all internal application cases. The ECturn is very flexible and permits all hinge variants, both for DIN left-hand and DIN right-hand doors.
GEZE ECturn
GEZE ECturn
580
5 60
60
94,5
20,7
31 442 (512)
5 60
60
94
max. 277
GEZE ECturn
Technical data
ECturn, EMD,
TSA 160 NT
GEZE ECturn
Areas of application
ECturn, EMD,
TSA 160 NT
Note
In low-energy mode the swing door drive moves at reduced speed and thus meets the safety requirement of DIN 18650. The use of safety sen-
sors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing
area of the door must always be safeguarded with safety sensors.
Automatic swing
door systems
ECturn
Y 140
120
100
1
80
2
60
40
20
0
600 700 800 900 1000 1100 X
Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).
5 60
16
44*
42
1
74
16
32*
33
10
21
59
2
70
* = Direct installation
1 = ECturn space requirement
2 = Guide rail space requirement
3 = GC 334 space requirement
GEZE ECturn
A B
575
415 633
390,5 390,5
Automatic swing
3 266
door systems
302 3
142 131
78 78
1 1
ø16
ø16
Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70107-ep02
Soffit depth (max.) 30 mm
5 60
16
44*
1
60
42
16
10
30*
33
35
72
3
84
* = Direct installation
1 = ECturn space requirement
2 = Guide rail space requirement
3 = GC 334 space requirement
GEZE ECturn
ECturn, EMD,
TSA 160 NT
A B
575
415 633
390,5 390,5
Automatic swing
266
door systems
1 302
142 1 131
78 78
ø16
2 2
ø16
ø16
498,5 70 498,5 70
3 3
Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70107-ep03
Soffit depth (max.) 200 mm
60
5
16
1
44*
42
60
16
34*
35
26
34
75
3
86
* = Direct installation
1 = ECturn space requirement
2 = Link arm space requirement
3 = GC 334 space requirement
GEZE ECturn
A B
575
415 633
390,5 390,5
Automatic swing
1 302 266
door systems
1
142 131
78 78
2 2
ø16
ø16
42,5 287 42,5 287
3 3
Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70107-ep04
Door overlap (max.) 50 mm
60
35
24
32*
33
16
110
42
60
44*
16
99
* = Direct installation
1 = Guide rail space requirement
2 = ECturn space requirement
3 = GC 334 space requirement
GEZE ECturn
ECturn, EMD,
TSA 160 NT
A B
1
Automatic swing
door systems
ø16
2 2
ø16
78 78
142 131
302 266
390,5 3 390,5 3
1
415 633
575
Door leaf installation with link arm on the hinge side, single-leaf
5 60
1
34
26
34*
35
16
44*
2
60
42
16
110
3
99
* = Direct installation
1 = ECturn space requirement
2 = Link arm space requirement
3 = GC 334 space requirement
GEZE ECturn
A B
1 1
ø16
2 2
ø16
78
78
142 131
302 266
390,5 390,5
415
633
575
Door leaf installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70107-ep05
Soffit depth (max.) 20 mm
5 60 1
35
32*
33
16
42
44*
60
16
99
2
110
* = Direct installation
1 = Guide rail space requirement
2 = ECturn space requirement
3 = GC 334 space requirement
GEZE ECturn
ECturn, EMD,
TSA 160 NT
A B
1 2 1 2
Automatic swing
door systems
498,5 100 498,5 100
3 3
ø16
ø16
58 58
122
282 111
370,5 246
395
370,5
555
613
Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG
4 = J-Y(ST)Y 4 x 2 x 0.6 LG
5 = LiYY 2 x 0.25 mm2
6 = LiYY 4 x 0.25 mm2
7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2
8 = Route empty pipe with pull-wire inner diameter 10 mm
Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall
1) Door transmission cable (included in the scope of supply for sensor strip)
2) Cable exit for door drive, see installation drawings for ECturn 70107-ep01 to -ep06
3) Cable including in the scope of supply for the sensor
4) + 5) Connection box for mains supply and control cable combined on site. Mains supply and control cable must be wired in separate ter-
minal spaces.
4) Mains connection box WxHxD min. 65 x 65 x 57
5) Control cable box WxHxD min. 94 x 65 x 57 with PG-11 duct
Abbreviations
HS = Main switch
NOT = Emergency-stop switch
KB = Contact sensor authorised
PS = Programme switch
ST = Emergency stop
KI = Contact sensor inside
KA = Contact sensor outside
TOE = Door opener
RM = Bar message
GEZE ECturn
I
ECturn, EMD,
TSA 160 NT
II
III
B+200 4)
A
5)
IV
B KI
Automatic swing
door systems
B
1 1 1 1 3 3 3 3 3 ECturn
8 8 KA
max. 300
max. 100
B/2
B/2
HS NOT KB PS ST KI KA
V V 3) 3)
1-leaf
I II
A A
4)
B B 5)
1
ECturn 2)
7 ECturn 2)
8
GC 334 GC 334
1)
8 8
TOE TOE
RM RM
ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1 and 2-leaf single-action doors
The electromechanical swing door drive GEZE Slimdrive EMD stands out due to its numerous areas of application. The compact drive is only
7 cm high and can move large and heavy internal and external doors comfortably and quietly. This makes the Slimdrive EMD the ideal solution
Automatic swing
door systems
wherever efficiency has to be coupled with silent running. State-of-the-art control technology combined with a low-wear and maintenance-
free high-power motor guarantees reliable operation even for doors which are heavily frequented. All door parameters e.g. opening and
closing speed as well as latching action, can be optimally adapted. Manual door opening can be supported by the drive (servo function) and
ensures that even heavy doors can be opened more easily manually. The push & go function can be activated on request, i.e. the door is only
slightly opened by hand and the automatic actuation opens the door completely. In low-energy mode, the drive moves the door at reduced
speed. The optional CAN interface can be used to meet demanding requirements e.g. air lock control.
650
8 121
72
113
30
710
Product features
GEZE Slimdrive
GEZE Slimdrive
GEZE Slimdrive
GEZE Slimdrive
EMD Invers
ECturn, EMD,
TSA 160 NT
EMD F-IS
EMD-F
EMD
Automatic swing
Height 70 mm
door systems
Width 650 mm
Depth 121 mm
Leaf weight (max.) 1-leaf 180 kg 230 kg
Hinge size (min.-max.)* 2-leaf 1500 – 2800 mm
Leaf width (min.-max.)* 750 – 1400 mm
Soffit depth (max.)* 400 mm
Door overlap (max.)* 30 mm
Drive type Electromechanical
Door opening angle (max.)* 115 °
Spring pre-load EN3 – EN6
Left-hand ● ● ● ●
Right-hand ● ● ● ●
Transom installation opposite hinge side with link arm ● ● ● ●
Transom installation opposite hinge side with guide rail ● ● ● ●
Transom installation hinge side with guide rail ● ● ● ●
Door leaf installation opposite hinge side with guide rail - - - -
Door leaf installation hinge side with guide rail ● ● ● ●
Door leaf installation hinge side with link arm - - - -
Mechanical latching action - ● ● -
Electrical latching action ● ● ● ●
Electrical closing sequence control ● ● ● ●
Mechanical closing sequence control - - ● -
Disconnection from mains Cable plug connection
Activation delay (max.) 20 S
Operating voltage 230 V
Frequency of supply voltage 50 – 60 Hz
Capacity rating 230 W
Power supply for external consumers (24 V DC) 1200 mA
Temperature range -10 – 50 °C
Enclosure rating IP 20
Operating modes Off, Automatic, Permanently open, Shop closing, Night
Type of function Fully automatic
Automatic function ● ● ● ●
Low-energy function ● ● ● ●
Servo function - ● ● ●
Key function ● ● ● ●
Inverse function (opening by spring force) - - - ●
Draught-proofing ● ● ● ●
Obstruction detection ● ● ● ●
Automatic reversing ● ● ● ●
Push & go adjustable
Operation Programme switch DPS, Programme switch MPS,
Programme switch TPS, Programme switch integrated in the drive
Parameter setting Programme switch DPS
CAN interface optional
Approvals DIN 18650 DIN 18650 DIN 18650 DIN 18650
DIN 18263-4 DIN 18263-4
Closing
sequence cont-
roller tested acc.
to EN 1158
Suitable for fire proof doors - ● ● -
● = yes Note: The maximum possible leaf weight in relation to leaf width can be found in the
- = not available chapter on areas of application (diagrams)!
* = depending on the type of installation
ECturn, EMD,
TSA 160 NT
Type of Installation Transom Installation Door leaf Installation Transom Installation opposite hinge side
hinge side (min.-max.) hinge side (min.-max.) (min.-max.)
Linkage element guide rail guide rail guide rail link arm
Spring pre-load Closer
3-5 3-5 3-5 4-6
Automatic swing
size EN 1154
door systems
Closing torques 20 - 45 Nm 17 - 43 Nm 20 - 45 Nm 35 - 70 Nm
Opening torques,
122 - 97 Nm 125 - 96 Nm 115 - 90 Nm max. 150 Nm
automatic
Opening torques,
45 - 66 Nm 50 - 73 Nm 42 - 65 Nm 61 - 88 Nm
manual
Note: For automatic mode, the doors must be equipped with suitable hinges. A door stop is necessary.
Areas of application
Note
In low-energy mode the swing door drive moves at reduced speed and thus meets the safety requirement of DIN 18650. The use of safety sen-
sors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing
area of the door must always be safeguarded with safety sensors.
Slimdrive EMD
Y 240
220
200
180
160
140
120
100
1 2
80
60
40
20
0
700 800 900 1000 1100 1200 1300 1400 X
Slimdrive EMD-F
ECturn, EMD,
TSA 160 NT
Y 240
230
220
200
180
1
160
Automatic swing
door systems
140
2
120
100
80
60
40
20
0
700 800 900 1000 1100 1200 3 1300 1400 X
Note
We recommend the use of link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account.
Dimensions marked by an asterisk (*) are valid for direct attachment.
Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).
8 121
14
51,2*
14
1
95
14
*
38
43
10
20
50
2
3
70
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
ECturn, EMD,
TSA 160 NT
A B
620 620 3
577 540
394 3 412 max. 20
1 256 1 274
Automatic swing
73 30
door systems
30 14
max. 20
max. 20
2
2
89 698
89 698
4 4
Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70106-ep02
Soffit depth (max.) -30 to +50 mm
Door opening angle (max.) 105°
8 121
14
51,2 *
1
75
14
14
38 *
43
29
39
3
70
90
39
39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A B
636
598 2 598
577 376
394 238
256
Automatic swing
2 1 max. Ø 20
110
door systems
max. Ø 20 73 1
52 52
3
3
max. Ø 20
max. Ø 20
698 82
698 82
4
Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70106-ep03
Soffit depth (max.) 0-100 mm, 100-200 mm, 200-300 mm
Door opening angle (max.) 110°
8 121
14
51,2*
1
14
75
14
43*
48
34
47
75
3
95
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement
ECturn, EMD,
TSA 160 NT
A B
598
577 636
2
2 394 376
max. Ø 20 256 238
1
Automatic swing
73 max. Ø 20 110
door systems
1
52 52
3 3
max. Ø 20
max. Ø 20
44 417 44 417
4 4
Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep04
Door overlap (max.) 30 mm
Door opening angle (max.) 115°
8 121 2
39
29
38 *
43
14
1
51.2 *
14
70
14
3
100
120
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A B
69 748
69 748
666
628 628
607 406
424 268
Automatic swing
286 Ø 20 1 Ø 20
1
door systems
103 2 140 2
82 82
Ø 20
Ø 20
3 3
4 4
8 121
14
51,2*
14
1
95
14
43
38*
10
20
50
2
3
70
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
ECturn, EMD,
TSA 160 NT
721 A 721
620 620
577 577
394 394
256 Ø 20 2 256
73 73
30 30
3
Ø 20
Automatic swing
door systems
89 698 698 89
4 4
1 1
5
662
662 B 620
620 540
540 412
412 274
274 Ø 20 2
30 30
3 14 14
Ø 20
89 698 698 89
4 4
1 1
5
Transom installation with guide rail on the opposite hinge side, double-leaf
Drawing no. 70106-ep22
8 121
14
51,2*
1
72
14
14
38*
43
29
39
3
70
90
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
721 721
598 A 598
577 577
394 394
1 256 256 1
73 Ø 20 3 73
52 52
Automatic swing
Ø 20
door systems
698 82
82 698
4 4
5
662 662
636 636
598 B 598
376 376
238 Ø 20 3 238 1
1 110
110
52 52
Ø 20
82 698 698 82
4 4
5
Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70106-ep23
8 121
14
51,2*
1
14
75
14
43*
48
34
47
75
3
95
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement
ECturn, EMD,
TSA 160 NT
A
721 721
598
598 577
577 394
1 394 1
256 Ø 20 256
73 2 73
3 52 52
Automatic swing
door systems
Ø 20
417 44 44 417
4 4
5
662 662
636 B 636
598 598
376 376
238 Ø 20 238
1 110 2 110 1
3 52 52
Ø 20
417 44 44 417
Door leaf installation with guide rail on the hinge side, double-leaf
Drawing no. 70106-ep24
8 121 2
39
29
38*
43
14
1
51.2*
14
70
14
3
100
120
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A
69 748 748 69
628 628
607 607
424 424
286 Ø 20 286
1 103 2 1
103
82 82
Ø 20
Automatic swing
door systems
4 4
5
69 748 B 748 69
666 666
628 628
406 406
1 268 268 1
140 Ø 20 140
2
82 82
Ø 20
3
4 4
5
ECturn, EMD,
TSA 160 NT
Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG
Automatic swing
door systems
4 = J-Y(ST)Y 4 x 2 x 0.6 LG
5 = LiYY 2 x 0.25 mm2
6 = LiYY 4 x 0.25 mm2
7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2
8 = Route empty pipe with pull-wire inner diameter 10 mm
Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall
1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not permitted for
fire protection doors.
2) Cable exit for door drive, see installation drawings for Slimdrive EMD/EMD-F 70106-ep01 to -ep04
3) Cable including in the scope of supply for the sensor
4) Install in the direct vicinity of the door
5) Mains connection box WxHxD min. 65 x 65 x 57 with PG-11 duct, on site
6) Low-voltage connection box WxHxD min. 94 x 65 x 57 with PG-11 duct, on site
7) E.g. door transmission cable, 8-wire, art. no. 066922
8) Branch box, on site
Abbreviations
HS = Main switch
NOT = Emergency-stop switch
I
TSA 160 NT
II
III
B+200 5)
A
B
C 6)
D/D* KI
Automatic swing
IV
door systems
B
1 1 1 1 2 2 3 3 3 3 3 EMD/EMD-F
8 8 KA
max. 300
max. 100
B/2
B/2
HS NOT UT KB PS ST KI KA
V V 4) 3) 3)
1-leaf
I II
A A
RS 3 RS 3 RS 3 RS 3
B RSZ 1 8) B RSZ 1 5)
C C
D D 6)
2 1
EMD/EMD-F 2)
7 EMD/EMD-F 2)
8
GC 334 GC 334
1)
3 3
8 8
TOE TOE
RM RM
2-leaf
I II
A
RS 3 RS 3 A
B RSZ 1 8) RS 3 RS 3
B RSZ 1
1 5) 1 5)
C C 3 8
6) 6)
D D* 3 8 D
3 8
3 8 TOE
2 1 RM
2) TOE 2)
EMD/EMD-F EMD/EMD-F
D
* RM EMD/EMD-F 2) 7 EMD/EMD-F 2)
8 7
GC 334 GC 334 GC 334 GC 334
4
7 1)
8 6
7) 6 TOE
RM
TOE
RM III IV
III IV
I = Transom installation
II = Door leaf installation
III = Fixed leaf
IV = Active leaf
ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1-leaf and 2-leaf single-action doors (RWA fresh air supply and doors in emergency exit
routes)
Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).
Automatic swing
door systems
Transom installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep01
8 121
14
51,2*
14
95
14
*
38
43
10
20
50
2
3
70
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A B
620 636
577 620
1 394 1 376
256 max. Ø 20 2 238 max. Ø 20 2
73 110
30 30
3 3
54
54
max. Ø 20
max. Ø 20
75 748 75 748
4 4
Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70106-ep02
ECturn, EMD,
TSA 160 NT
8 121
Automatic swing
door systems
14
51,2 *
75
14
14
38 *
43
29
39
3
70
90
2
39
39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A B
598
577 598
394 540
256 412
73 274 1
max. Ø 20 1 max. Ø 20 52
3 52 3
14
2 2
35
35
max. Ø 20
max. Ø 20
748 75
748 75
4 4
Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70106-ep03
ECturn, EMD,
TSA 160 NT
8 121
Automatic swing
door systems
14
51,2*
1
14
75
14
43*
48
34
47
75
95
2
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement
A B
577 1 540
394 412
256 1
274
73
3 3 14
2 2
max. Ø 20
max. Ø 20
44 417 44 417
4 4
Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep04
ECturn, EMD,
TSA 160 NT
8 121 2
Automatic swing
door systems
39
29
38 *
43
14
1
51.2 *
14
70
14
3
100
120
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
A B
75 748 75 748
628 628
607 570
1 424 442
286 1
304
103 max. Ø 20 max. Ø 20 2
2 82
82 44
3 3
35
35
max. Ø 20
max. Ø 20
4 4
ECturn, EMD,
TSA 160 NT
8 121
Automatic swing
door systems
14
51,2*
14
95
14
43
38*
10
20
50
2
3
70
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
721 A 721
620 620
1 577 577 1
394 394
256 max. Ø 20 3 256
73 73
30 30
2
54
max. Ø 20
4 4
5
662 B 662
636 636
1 620 620 1
376 376
238 238
110 110
30 30
Transom installation with guide rail on the opposite hinge side, double-leaf
Drawing no. 70106-ep22
ECturn, EMD,
TSA 160 NT
8 121
Automatic swing
door systems
14
51,2*
72
14
14
38*
43
29
39
3
70
90
2
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
721 A 721
598
598 577
577
394 394 1
1 max. Ø 20 256
256 2
73 73
52 52
max. Ø 20
417 44 44 417
4 4
5
662 662
598 598
540 B 540
412 412
1 274 274
max. Ø 20 52 1
52 2
14 14
max. Ø 20
417 44 44 417
Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70106-ep23
ECturn, EMD,
TSA 160 NT
8 121
Automatic swing
door systems
14
51,2*
1
14
75
14
43*
48
34
47
75
95
2
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement
721 A 721
598
598 577
577
394 394 1
1 max. Ø 20 256
256 2
73 73
52 52
max. Ø 20
417 44 44 417
4 4
5
662 662
598 598
540 B 540
412 412
1 274 274
max. Ø 20 52 1
52 2
14 14
max. Ø 20
417 44 44 417
Door leaf installation with guide rail on the hinge side, double-leaf
Drawing no. 70106-ep24
ECturn, EMD,
TSA 160 NT
8 121 2
Automatic swing
door systems
39
29
38*
43
14
1
51.2*
14
70
14
3
100
120
39 39
* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement
75 748 A 748 75
628 628
607 607
424 424
1 286 Ø 20 286
103 2 1
103
82 82
Ø 20
4 4
5
69 748 748 69
B
628 628
570 570
442 442
1 304 304 1
82 2 Ø 20 82
44 44
4 4
ECturn, EMD,
TSA 160 NT
Electrohydraulic swing door drive for 1 and 2-leaf single-action doors
The TSA 160 NT is an electronically controlled hydraulic swing door system for single-action doors made of wood, steel, aluminium or plastic
with leaf weights of up to 310 kg and leaf widths up to 1600 mm. The drive works with a hydraulic pump system during opening. The closing
Automatic swing
door systems
process is by means of a closing spring mechanism and adjustable hydraulic valves. The TSA 160 NT also has low power consumption and is
low-maintenance. The door can be opened by hand in the event of a power failure. Manual opening is also possible with with motor operation
switched on. A reinforced and highly stable link arm meets the requirements of large and heavy doors which are highly frequented. The TSA
160 NT masters large amounts of foot traffic reliably and easily.
690
8 121
100
150
30
465
Product features
Invers
EN7
Automatic swing
door systems
Height 100 mm
Width 690 mm
Depth 121 mm
Leaf weight (max.) 1-leaf 250 kg 310 kg
Hinge size (min.-max.) 2-leaf 1470 – 2800 mm 1470 – 3200 mm
Leaf width (min.-max.) 690 – 1400 mm 690 – 1600 mm
Soffit depth (max.)* 400 mm
Door overlap (max.)* 20 mm
Drive type Electrohydraulic
Door opening angle (max.)* 115 °
Spring pre-load EN3 – EN6** EN7
Z-variant (pulling) ● - ● ●
Z-variant (pushing) - ● - -
Left-hand ● ● ● ●
Right-hand ● ● ● ●
Transom installation opposite hinge side with link arm ● ● ● ●
Transom installation opposite hinge side with guide rail - - - -
Transom installation hinge side with guide rail ● ● ● ●
Door leaf installation opposite hinge side with guide rail - - - -
Door leaf installation hinge side with guide rail - - - -
Door leaf installation hinge side with link arm - - - -
Mechanical latching action ● - ● ●
Electrical latching action - - - -
Electrical closing sequence control ● ● ● ●
Mechanical closing sequence control - - ● -
Disconnection from mains Not available
Activation delay (max.) 10 S
Operating voltage 230 V
Frequency of supply voltage 50 – 60 Hz
Capacity rating 300 W 400 W
Power supply for external consumers (24 V DC) 1200 mA
Temperature range -10 – 60 °C
Enclosure rating IP 20
Operating modes Off, Automatic, Permanently open, Shop closing, Night
Type of function Fully automatic
Automatic function ● ● ● ●
Low-energy function - - - -
Servo function - - - -
Key function ● ● ● ●
Inverse function (opening by spring force) - ● - -
Draught-proofing ● ● ● ●
Obstruction detection ● ● ● ●
Automatic reversing ● ● ● ●
Push & go adjustable
Operation Programme switch DPS, Programme switch MPS,
Programme switch TPS, Programme switch integrated in the drive
Parameter setting Programme switch DPS, Controller
Approvals DIN 18650
Suitable for fire proof doors - - - -
Use on smoke and fire doors (F-variant) ● - ● -
● = yes
- = not available
* = depending on the type of installation
** = This does not apply for Z-variant
ECturn, EMD,
TSA 160 NT
pushing (min.-max.) pulling (min.-max.)
Spring pre-load
3-6 -
Closer size EN 1154
Closer torques:
Automatic swing
door systems
torque exerted by the closing spring 20 Nm - >60 Nm 8 Nm - 30 Nm
during automatic opening
Opening torque:
torque exerted by the door 150 Nm - 90 Nm 70 Nm - 40 Nm
during automatic opening
Opening torque:
manual torque to be exerted for door 35 Nm - 110 Nm 13 Nm - 45 Nm
opening
TSA 160 NT minimum and maximum leaf widths, hinge size for double-leaf doors
Areas of application
ECturn, EMD,
TSA 160 NT
TSA 160 NT
Y 300
Automatic swing
door systems
250
200
1
150
2
100
50
700 800 900 1000 1100 1200 1300 1400 X
TSA 160 NT E7
Y 350
310
300
250
1
200
2
150
100
50
700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 X
Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).
ECturn, EMD,
TSA 160 NT
Transom installation with guide rail on the hinge side, single-leaf
Drawing no. 70423-ep02
Automatic swing
door systems
8* 121
29*
22*
54
119
1
29*
29* 42
63
50
31
31
3
80
A B
20 650
625 487.5
Ø 20 325 Ø 20 1
34 420 Ø 20 1 162.5
1
Ø 20
1
48
50
50 587
50 587
A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
1
Automatic swing
door systems
453 X
1 = Mounting plate
Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70423-ep01
121 8*
29*
1
54
22*
100
29*
4
27+X
41*
2
40
3
39
85
650
ECturn, EMD,
TSA 160 NT
487.5
325
20 162.5 625
Ø 20 1 Ø 20 1 34 420 Ø 20 1
29 22 29
Ø 20 1
Automatic swing
50
door systems
48
587
10
587
44 44
50
50
335
335
A B
A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
Transom installation with guide rail on the hinge side, double-leaf
Drawing no. 70423-ep22
8* 121
29*
1
22*
54
119
29*
42
29
50
2
31
60
80
A 625
ECturn, EMD,
625
TSA 160 NT
34 420 Ø 20 420 34
1
Ø 20
1
48
453 186
50 587
Automatic swing
door systems
186 453
B
2 B/2
650 650
1 Ø 20 487.5 487.5
325 Ø 20 325
20 162.5 1 162.5 20
50
453 186
50 587
186 453
A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
2 = only required if B>2000
Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70423-ep11
121 8*
29*
1
100
22*
54
29*
51
55
X
86
2
40
39
85
max. 350
X = Spindle extension
* = Installation with mounting plate
1 = TSA 160 NT space requirement
2 = Link arm space requirement
3 = GC 338 space requirement
ECturn, EMD,
TSA 160 NT
625 625
34 420 Ø 20 420 34
1
Ø 20 1
48
Automatic swing
587
door systems
50 44 44
335 335
B /2 2
650 650
487.5 487.5
325 325
20 162.5 Ø 20 162.5 20
Ø 20 1 1
50
587
50 44 44
335 335
A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
2 = only required if B>2000
TSA 160 NT
Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG
Automatic swing
4 = J-Y(ST)Y 4 x 2 x 0.6 LG
door systems
Operator displacement
AV = Cable exit
60 mm = 580 mm
50 mm = 590 mm
40 mm = 600 mm (standard)
30 mm = 610 mm
20 mm = 620 mm
10 mm = 630 mm
0 mm = 640 mm
Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall
1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not
permitted for fire protection doors.
2) Cable exit for door drive see sketch A and B
3) Cable including in the scope of supply for the sensor
4) Install in the direct vicinity of the door
7) E.g. door transmission cable, 8-wire, art. no. 066922
8) Branch box, on site
Abbreviations
HS = Main switch
NOT = Emergency-stop switch
UT = Circuit breaker CLOSE DOOR (only with F variant)
KB = Contact sensor authorised
PS = Programme switch
ST = Emergency stop
KI = Contact sensor inside
KA = Contact sensor outside
TOE = Door opener
RM = Bar message
RS = Smoke switch (only with F variant)
RSZ = Smoke switch control unit (only with F variant)
TS = Door closer
MK = Magnetic contact
ECturn, EMD,
TSA 160 NT
I
II
III
A
B
C
Automatic swing
door systems
D/D*
IV
1 1 1 1 2 2 3 3 3 3 3
8 8
HS NOT UT KB PS ST KI KA
V V 4) 3) 3)
I II III
B+200 B+200
B+200
B+200
B/2
B
KI KI BWM
B
2xB
KA
B
KA
B
BWM
B/2
B/2
A
RS 3 RS 3
B RSZ 1 8)
C
D
Automatic swing
door systems
2 1
TSA 160 NT 2)
8
GC 334
1)
3
8
TOE
RM
I II
A A
RS 3 RS 3 RS 3 RS 3
B RSZ 1 8) B RSZ 1 8)
1 C
8)
C D
D
3 8 2 3
3 8 2 1
2 1 3 2 MK 8 8
TOE
TS TOE TSA 160 NT 2)
* TSA 160 NT 2) RM TSA 160 NT 2) 8 RM
D 8
8 GC 334
4 GC 334 GC 334 7) 1)
7 1) 6
8
7) 6 TOE
TOE RM
RM
III IV
III IV
I = 2-leaf
II = 2-leaf with manual fixed leaf
III = Fixed leaf
IV = Active leaf
I II III
68
54
68
54
68
IV V IV V IV V
AV = Operator displacement
I = TSA 160 NT installation, hinge side
II = TSA 160 NT installation, opposite hinge side
III = TSA 160 NT-Z installation, hinge side
IV = Drive left - pulling
V = Drive right - pulling
VI = from top of leaf, dimension for spindle extensions must be added
VII = Cable exit
Accessories
ECturn, EMD,
TSA 160 NT
Hood, mounting plate, link arm, guide rail with lever
Hood
The hood is available in an anodised or coloured finish. In the case of double-leaf versions, the hood can be ordered as a continuous variant or
Automatic swing
door systems
with intermediate hood.
Link arms
are offered for different soffit depths
Note
More detailed information about the following accessories can be found in the catalogue: GEZE actuation devices and sensor systems
Accessories
Programme switches for the selection of the operating mode for automatic swing doors
GEZE offers programme switches for a wide range of individual requirements. The switches are suitable for universal use – for surface-mounted
or flush-mounted installation. The following switch types are available:
Automatic swing
door systems
“Permanently open”
The door moves to the OPEN position and remains open. Movement detector or opening button are deactivated.
“Night”
The movement detectors are switched inactive, the door closes.
Option: The door leaves are locked electrically to prevent forced opening.
“Automatic”
The door opens as soon as it is actuated via the movement detector or keys, and closes after a certain individually adjustable time. Safety sen-
sors protect the leaves’ travel path. If there is someone in the door opening, the door will not close.
Key switch
The programme switch can be blocked using a key switch. A key switch is required for the FR variants.
Display programme switch (DPS) Key programme switch (TPS) Mechanical programme switch (MPS)
Accessories
Automatic actuation
ECturn, EMD,
TSA 160 NT
Reliable actuation with GEZE sensors
Automatic swing
door systems
reflection which is forwarded as a door opening signal. The pre-programmed convenience setting of the GEZE radar movement detectors
ensures they can be put into operation quickly. Automatic configuration is possible via keys or a remote control. Reliable detection is achieved
with a clearly defined radar field. Energy can be saved through detection of people’s direction of movement. Excessive door opening is avoided
since cross-traffic can be faded out.
GEZE TSA 160 NT IS and Radar movement detector, Andels Hotel, Berlin
Accessories
Manual actuation
ECturn, EMD,
TSA 160 NT
Push buttons
GEZE push buttons for the wireless actuation of system doors – reliable, convenient and safe at the push of a button.
Automatic swing
door systems
Non-contact infrared-sensor
Open doors in a flash: With GEZE infrared sensors, internal doors without precise perception requirement can be actuated cleanly and comfor-
tably. Active infrared sensors ensure hygienic access to toilet facilities, for example. The risks of infection are also minimised in hotel kitchens,
hospitals and doctors’ surgeries. The impulse generator is installed at hand height and precisely detects people and objects – independently
of their direction of movement – both in the direct vicinity of only 5 cm as well as 0.6 m away. The different scanning ranges can be optimally
adapted to existing environmental conditions and the wishes of the user groups. The non-contact sensor system provides maximum operating
convenience – people only need to approach them to trigger the automatic opening mechanism. The optimum system structure permits
simple and time-saving installation in the flush-mounted box.
Radio actuation
GEZE radio transmitters are used for wireless actuation of doors and windows as a multi-channel solution. For every additional channel, an
additional electrical device or function can be switched at the push of a button. Thanks to the very small size of the radio modules, radio trans-
mitters can easily be integrated in the drive or in a flush-mounted box. They can also be clipped directly into the elbow switched and mounted
without wires on glass.
Radio actuation Large-scale button made of plastic Large-scale button made of stainless steel
Accessories
Electronic protection
ECturn, EMD,
TSA 160 NT
Safety sensor strips
Safety sensor strips are used to monitor and safeguard the pivoting area of automatic swing door leaves. They are installed on both sides of the
Automatic swing
door systems
door, directly on the leaf. This guarantees maximum protection both during opening and closing of the door.
GEZE safety sensors work with infrared light. Electromagnetic waves which are invisible to the human eye are directed by a transmitter to
people or objects within the area of detection. A receiver absorbs the reflected infrared beams and converts them into an electric signal which
is transmitted to the control unit of the door drive. Door movement in the opening direction is stopped as soon as the sensor registers an
obstacle. It is possible for the wall areas to be faded out by the safety sensors (teachable). In closing direction, the sensor actuates the drive of
the closing door and opens it again.
•• Reliable function for all weather and floor conditions up to 3.5 m in accordance with DIN 18650
•• A sensor system protects door leaf widths up to 1200 mm
•• Background elimination: sensor can detect a wall and eliminate it automatically
•• Elegant guide rail, can be realised even with slim door profiles
•• Sleep mode if the sensor is not required - saves up to 50% energy in relation to comparable sensors
•• Current consumption in operating mode: 200 mA
•• Current consumption in sleep mode: 100 mA
•• Fast and simple installation of the modules thanks to the SNAP IN mechanism which allows modules to be positioned and fixed in the profile
without tools being necessary
Accessories
E2
S1 S2 E1 2) The second transmitter module (S2) is positioned directly
next to this (distance: 10 to 15 mm)
Automatic swing
door systems
Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).
90 Lx
1 1 Ø10
1
„Open“ safety sensor mounted on the hinge „Close“ safety sensor mounted on the oppo- Safety sensor hole pattern, hinge side
side site hinge side
Lx 90
1 1 Ø10
1
„Close“ safety sensor mounted on the oppo- „Open“ safety sensor mounted on the hinge Safety sensor hole pattern, opposite hinge
site hinge side side side
1 = optional power supply, concealed routing possible. Drillhole Ø 10 for concealed line-feed.
Lx = Profile length 1100 mm : Lx = 489 mm; profile length 1500 mm : Lx = 699 mm
Accessories
ECturn, EMD,
TSA 160 NT
requirement for swing door systems specified in DIN18650. The sensor and the guide rail can be put together in such a way that thay look like
a single compact and more integrated design. The features at a glance:
Automatic swing
•• Suitable for single and double-leaf swing door
door systems
•• Available for all TSA 160 NT and Slimdrive EMD variants with guide rail
•• Sensor and guide rail profile are avalable separately, facilitating retrofittings to existing systems
•• The flexible kit ans a rain cover are avalable as accessor
•• Better integration of link arm and sensor strip GC 334 and GC 338 into the door design
•• Simple installation, in particular in case of slim door frames
•• With the new link arms a maximum soffit depth of 400 mm can now be bridged
Adapter for sensor and link arm for slimdrive EMD and TSA 160 NT
Swing Door Systems 61
Automatic swing door systems
Accessories
EMD and GC GR (GC 334) transom installation with guide on the hinge side
Drawing no. 70106-ep34
ECturn, EMD,
TSA 160 NT
Automatic swing
door systems
EMD
35
71
GC 334
59
GC 334
46 76
EMD and GC GR (GC 334) transom insatallation with guide rail on the opposition hinge side
Drawing no. 70106-ep34
EMD
35
71
GC 334 GC 334
46 76
Accessories
TSA 160 NT and GC GR (GC 334) transom insatallation with guide rail on the hinge side
Drawing no. 70106-ep34
ECturn, EMD,
TSA 160 NT
Automatic swing
door systems
TSA 160 NT
40
21
76
GC 334
69
GC 334
76
46
A B
L/2 L/2
L/2 L/2 30 60 30
30 60 30 9 9
9 9
0
0
Ø1
Ø1
Ø6
Ø6
0
Ø1
Ø6
Ø1
Ø6
0
FB FB
A = Hinge side
B = Opposition hinge side
FB = Leaf width
L = Length
Accessories
Service Tools
ECturn, EMD,
TSA 160 NT
GEZEconnects
Bluetooth is an internationally standardised short-distance radio signal with a range of up to ten metres. The software GEZEconnects makes
Automatic swing
door systems
wireless connection via Bluetooth possible between a computer and the automatic door systems from GEZE. All door system settings can be
carried out via an intuitive graphic interface, stored, sent by e-mail and transferred to a word processing programme as a protocol. Diagnosis
functions show the most important function parameters of the door system in real time, so that problems are recognised at a glance and can
be eliminated. All the pre-settings can be taken over very easily for further door systems. The convenient documentation of initial operation,
servicing and diagnosis protocols as well as all statistical data can be downloaded at any time. Password protection to freeze operating para-
meters and servicing data guarantees there will be no unauthorised modifications made.
Note
GEZE service tools are available for the Slimdrive EMD and TSA 160 NT range of drives.
AUTOMATISCHE
CD Laufwerk
TÜRSYSTEME www.geze.com
Bluetooth Schnittstelle
150 MB freier Speicherplatz
RWA UND
GEZEconnects I SOFTW ARE
GEZEconnects
LÜFTUNGSTECHNIK
SICHERHEITSTECHNIK
B EW E G U N G M I T S Y S T E M
B EW E G U N G M I T S Y S T E M
References
ECturn, EMD,
TSA 160 NT
Automatic swing
door systems
GEZE TSA 160 NT, BMW World, Munich, Germany
You will find more product information in the relevant brochures, see ID numbers.
ECturn, EMD,
TSA 160 NT
Door technology
Hold-open systems
02
ID 091593, ID 091594
Floor springs
04
ID 091607
Revolving doors
09 06 17
ID 132050
06
Actuation devices and sensors
10
ID 142655 11
Safety technology
07
Panic locks
18
ID 132848
Electric strikes
19
ID 148666
Glass systems
ECturn, EMD,
TSA 160 NT
Door technology
Automatic swing
door systems
the range, the ability to use them on all common door leaf
widths and weights, and the fact that they can be individu-
ally adjusted makes their selection simple. They are con-
tinually being improved and enhanced with up-to-date fea-
tures. For example, the requirements of fire protection and
accessibility are fulfilled with a door closer system.
Safety technology
Building systems
16
09
19
In GEZE’s Building Management System GEZE door, win-
dow and safety products can be integrated in to the se-
curity and control systems of the building. A central con-
trol and visualisation system monitors various automation
components in the building and offers security through
many different networking capabilities.
Glass systems