G E Z E automatic door systems

GEZE swing door systems


varied, Barrier-free and Strong

BEWEGUNG MIT SYSTEM


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Table of contents

ECturn, EMD,
TSA 160 NT
Foreword: GEZE swing door systems 4
Overview table 5
Types of installation 6

Automatic swing
door systems
Automatic swing door systems
For fire and smoke protection doors (F) 7
With integrated closing sequence control (IS) 7
With integrated closing sequence control for double-leaf fire and
smoke protection doors (F-IS) 8
With integrated closing sequence control for double-leaf doors, automatic doors
and door closer function (IS/TS) 8
For fresh air supply as well as doors in emergency exit routes (Invers) 9
For large and heavy doors, as well as frequently used doors (EN7) 9
Special area of application: Toilets for the disabled 10
Swing door drives
GEZE ECturn 11
GEZE Slimdrive EMD 21
GEZE TSA 160 NT 43
Accessories (Cover, mounting plate, link arm, guide rail with lever) 55
Operation 56
Actuation 57
Protection 59
Service Tools 64

Swing Door Systems 3


Automatic swing door systems

ECturn, EMD and TSA 160 NT

GEZE swing door systems


ECturn, EMD,
TSA 160 NT

Open and close doors easily

The swing door systems For large and heavy doors, as well as frequently used doors from GEZE make it easier to pass through doors whenever
manual operation is too cumbersome or difficult. The outstanding features of the systems include reliability and safety, as well as a clear and
Automatic swing
door systems

modern design. GEZE implements building-specific solutions and guarantees planners maximum design freedom.

The electromechanical ECturn drive allows internal doors to be opened and closed gently and easily for barrier-free access.

Thanks to their uniquely small overall height of only seven centimetres, the drives in the Slimdrive range can be fitted almost invisibly to any
building architecture.

The electrohydraulic TSA range is the first choice for doors in frequently used areas. Durability and strength are the characteristics of this range.

DIN 18650
The industrial standard DIN 18650 was created to be able to guarantee operators and users of automatic doors optimum safety. GEZE swing
door systems with automatic function have been type-tested to DIN 18650 and certified.

Design possibility for swing door systems

2
2

1 = Drive
2 = Actuation
3 = Safeguarding
4 = Operation

4 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Overview table for swing door systems

ECturn, EMD,
TSA 160 NT
ECturn Slimdrive EMD TSA 160 NT

Automatic swing
door systems
Product features

Dimensions drive (height x width x depth) 60x580x60 mm 70x650x121 mm 100x690x121 mm

GLS 180 kg 250 kg


Leaf weight (max.) 125 kg
GST 230 kg* 310 kg**

GLS 850 mm
Leaf width (min.) 650 mm 690 mm
GST 750 mm

GLS 1400 mm
Leaf width (max.) 1100 mm 1400 mm
GST 1600 mm**

GLS – 1700-2500 mm
Hinge clearance on double-leaf doors 1470-2800 mm
GST – 1500-2800 mm

Opening and closing speed adjustable ● ● ●

Electrical closing sequence control ● ●

Electromechanical drive ● ●

Electrohydraulic drive ●

External doors / Internal doors –/● ●/● ●/●

1-leaf / 2-leaf ●/– ●/● ●/●

Guide rail / Link arm ●/● ●/● ●/●

Functions

Automatic ● ● ●

Push & Go adjustable ● ● ●


Low-Energy ● ●
Servo ●

Variants

For fire and smoke protection doors (F) ●* ●

With integrated closing sequence control (IS) ●* ●

With integrated closing sequence control for double-leaf fire and


●* ●
smoke protection doors (F-IS)

With integrated closing sequence control for double-leaf doors,



automatic doors and door closer function (IS/TS)

For fresh air supply as well as doors in emergency exit routes


● ●
(Invers)

For large and heavy doors, as well as frequently used doors (EN7) ●

Page 10 21 43

GLS = guide rail


GST = link arm ● = Yes * = Slimdrive EMD-F ** = TSA 160 NT EN7

Note: The maximum possible leaf weight in relation to leaf width can be found in the chapter on areas of application (diagrams)!

Swing Door Systems 5


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Types of installation for swing door systems


ECturn, EMD,
TSA 160 NT

The following diagrams show the installation possibilities for swing doors and the drives which can be used to realise this application.
Automatic swing
door systems

Notes
A door stopper is always required.
We recommend link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account.

Installation on the hinge side

Transom installation with guide rail Door leaf installation with guide rail Door leaf installation with link arm
1 = ECturn 1 = ECturn 1 = ECturn
2 = Slimdrive EMD 2 = Slimdrive EMD
3 = TSA 160 NT
4 = TSA 160 NT Z
5 = TSA 160 NT Invers

Installation on the opposite hinge side

Transom installation with link arm Transom installation with guide rail Door leaf installation with guide rail
1 = ECturn 1 = ECturn 1 = ECturn
2 = Slimdrive EMD 2 = Slimdrive EMD
3 = TSA 160 NT
4 = TSA 160 NT Z Invers

6 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Swing door systems for fire and smoke protection doors (F)

ECturn, EMD,
TSA 160 NT
Drive systems in the F variant are used to automatically open and close single-leaf fire protection doors. The usual types of impulse generator
can be used to actuate the drive. In addition to automatic opening and closing, fire protection doors can also be held open. In the event of a

Automatic swing
door systems
fire, an appropriate fire detection system must cancel the automatic function or any hold-open mechanism. Power supply to the mains cable
is interrupted via a mains switch-off board (F-accessory) and the drive retains the normal door closer function. This means that door closers
with automatic opening function in accordance with DIN 18263 Part 4 are a component part of hold-open systems and require official building
approval. Fire protection doors must meet the requirements of the DIBt guideline (Deutsches Institut für Bautechnik).
This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT

F swing door

Augustinum retirement home, Stuttgart

Swing door systems with integrated closing sequence control (IS)

Swing doors in the IS variant are always equipped with an integrated closing sequence control. The mechanical closing sequence control en-
sures that the fixed leaf closes first on double-leaf doors. The active leaf only closes once the fixed leaf has closed completely. The mechanical
closing sequence control also works without electricity and in the event of a power failure.

This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT

IS swing door

Stiftung Ecksberg, Mühldorf

Swing Door Systems 7


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Swing door systems with integrated closing sequence control for double-leaf fire and smoke protection
doors (F-IS)
ECturn, EMD,
TSA 160 NT

Drive systems in the F-IS variant are used to automatically open and close double-leaf fire protection doors. A mechanical closing sequence
control is necessary for double-leaf fire protection doors, refer to the section on integrated closing sequence control (IS).
Automatic swing
door systems

This variant can be achieved using the following drive series: Slimdrive EMD-F and TSA 160 NT

F-IS swing door

Zamenhof care home, Stuttgart

Swing door systems with integrated closing sequence control for double-leaf doors, automatic doors
and door closer function (IS/TS)

With this variant for double-leaf swing door systems, the active leaf is automated with a swing door drive (TSA 160 NT), the fixed leaf is equip-
ped with a door closer (TS 160). Since the drive design is not interrupted, this system produces harmonious results, both in terms of function
and appearance. The preferred use for this swing door drive/door closer combination is when the active leaf is the one mainly moved. The
closing sequence control required for use on fire protection doors is also integrated in the drive housing. This guarantees that both door leaves
close in a controlled manner after they have been passed through. The fixed leaf can be held open by manually setting the programme switch
to “permanently open” and manually opening the door.
This variant can be achieved using the following drive series: TSA 160 NT IS/TS

F-IS/TS swing door

Kreissparkasse bank, Ludwigsburg

8 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Swing door systems for fresh air supply as well as doors in emergency exit routes (Invers)

ECturn, EMD,
TSA 160 NT
Inversely installed swing door drives are used on single and double-leaf single-action doors made of wood, plastic or steel. There is an elec-
trical closing sequence control available for double-leaf doors. Inversely installed drives are suitable for emergency exit routes and for fresh air

Automatic swing
door systems
opening systems for RWA systems. The doors are opened by spring force and closed by motor. This guarantees that the door will open safely
in the event of a power failure or fire alarm. An emergency power supply is no longer required.

This variant can be achieved using the following drive series: Slimdrive EMD and TSA 160 NT

Inverse swing door

Augustinum retirement home, Stuttgart

Swing door systems for large and heavy doors, as well as frequently used doors (EN7)

This variant is a reliable solution for the automation of very large and heavy swing doors which are frequently used. Drives in the EN7 range
are suitable for leaf weights up to max. 310 kg and leaf widths up to 1600 mm. These drives are particularly suitable for homes for the elderly,
hospitals, shopping centres, schools or airports.

This variant can be achieved using the following drive series: TSA 160 NT EN7

TSA 160 NT EN7 swing door

Robert Bosch hospital, Stuttgart

Swing Door Systems 9


Automatic swing door systems

ECturn, EMD and TSA 160 NT

Special area of application: Toilets for the disabled


ECturn, EMD,
TSA 160 NT

Toilets for the disabled must be designed in such a way that people with all sorts of different handicaps can use the facilities without needing
help. GEZE swing door drives provide an indispensable service for this application, and guarantee a high level of convenience.
Automatic swing
door systems

Function description
The door opens automatically after the large-sized button on the outside of the toilet has been pressed, and closes automatically after the set
hold-open time has passed.

When the user presses the switchover inside the toilet cubicle, the “occupied” sign outside the toilet is activated and the telltale lamp on the
change-over switch comes on. At the same time, the large-sized button is deactivated on the outside and on the inside. This means the door
cannot be opened by third parties nor by the user by mistake. The door opener is supplied with current, preventing manual opening of the
door from outside. When the user leaves the toilet, he presses the switchover again. The “occupied” sign outside and the telltale lamp inside
both go off. The drive is actuated by pressing the large-sized OPEN DOOR button inside the cubicle, and the door opens immediately.

In the event of a power failure, the closed circuit current door opener releases and the user can leave the cubicle by pushing or pulling the
door open. The door can also always be opened from the inside by pressing the large-sized button, even when the system is still powered. In
emergencies, the door can be opened manually from the outside by means of a key or by actuating the emergency-off switch.

4
6
5
2

1 = Swing operator Cologne-Bonn airport, Germany


2 = Large-scale OPEN DOOR button (inside and outside)
3 = Switchover: Lock/unlock door
4 = „Occupied“ indicator light
5 = „Occupied“ telltale lamp
6 = Emergency-stop switch (recommended installation height: 1600 mm)

10 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE ECturn

GEZE swing door drive ECturn

ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1-leaf single-action internal doors

This extremely quiet electromechanical swing door drive meets the requirements of barrier-free construction. It makes life easier and more
convenient – particularly for people with mobility problems or little strength. Doors can comfortably be opened automatically, or opened

Automatic swing
door systems
manually and closed automatically. The GEZE ECturn can be operated both in low-energy mode and in automatic mode in accordance with
DIN 18650. In low-energy mode, the drive moves the swing door at reduced speed. The use of safety sensors to safeguard the system is only
necessary in individual cases, taking the user group into account. In automatic mode, however, the swing area of the door must always be
safeguarded with safety sensors. An optional battery ensures maximum safety even in the event of a power failure. This swing door drive covers
all internal application cases. The ECturn is very flexible and permits all hinge variants, both for DIN left-hand and DIN right-hand doors.

GEZE ECturn

GEZE ECturn

580
5 60
60
94,5

20,7

31 442 (512)

5 60
60

94

max. 277

Application range •• Barrier-free internal doors


•• Hotel and restaurants
•• Hospitals and nursing homes for the elderly
•• Educational institutions e.g. schools, nursery schools, day care centres
•• Leisure facilities, e.g. swimming baths, thermal baths, sport and fitness centres
•• Administration and public buildings
•• Homes

Swing Door Systems 11


Automatic swing door systems

GEZE ECturn

Technical data
ECturn, EMD,
TSA 160 NT

Product features GEZE ECturn


Height 60 mm
Width 580 mm
Depth 60 mm
Automatic swing

Leaf weight (max.) 1-leaf 125 kg


door systems

Leaf width (min.-max.) 650 – 1100 mm


Soffit depth (max.)* 200 mm
Door overlap (max.)* 50 mm
Drive type Electromechanical
Door opening angle (max.)* 110 °
DIN left ●
DIN right ●
Transom installation opposite hinge side with link arm ●
Transom installation opposite hinge side with guide rail ●
Transom installation hinge side with guide rail ●
Door leaf installation opposite hinge side with guide rail ●
Door leaf installation hinge side with guide rail ●
Door leaf installation hinge side with link arm ●
Mechanical latching action -
Electrical latching action ●
Electrical closing sequence control -
Mechanical closing sequence control -
Disconnection from mains Main switch in the drive
Activation delay (max.) 10 S
Operating voltage (min.) 110 V
Operating voltage 230 V
Frequency of supply voltage 50 – 60 Hz
Capacity rating 75 W
Power supply for external consumers (24 V DC) 600 mA
Temperature range -15 – 50 °C
Enclosure rating IP 20
Operating modes Off, Automatic, Permanently open, Night
Type of function Fully automatic
Automatic function ●
Low-energy function ●
Servo function -
Key function ●
Inverse function (opening by spring force) -
Vestibule function -
Obstruction detection ●
Automatic reversing ●
Push & go adjustable
Operation Programme switch TPS, Programme switch integrated in the drive
Parameter setting Programme switch DPS, Controller
Approvals DIN 18650
Suitable for fire proof doors -
● = yes
- = not available
* = depending on the type of installation
Note: The maximum possible leaf weight in relation to leaf width can be found in the chapter on areas of application (diagrams)!

12 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE ECturn

Areas of application

ECturn, EMD,
TSA 160 NT
Note
In low-energy mode the swing door drive moves at reduced speed and thus meets the safety requirement of DIN 18650. The use of safety sen-
sors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing
area of the door must always be safeguarded with safety sensors.

Automatic swing
door systems
ECturn

Y 140

120

100
1
80
2
60

40

20

0
600 700 800 900 1000 1100 X

Note: Use on internal doors only!


X = Door width (mm)
Y = Door weight (kg)
1 = Area of application in low energy mode
2 = Area of application in automatic mode

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Transom installation with guide rail on the hinge side, single-leaf


Drawing no. 70107-ep01
Soffit depth (max.) 40 mm
Door overlap (max.) 40 mm

5 60
16
44*
42

1
74
16
32*
33

10

21
59

2
70

* = Direct installation
1 = ECturn space requirement
2 = Guide rail space requirement
3 = GC 334 space requirement

Swing Door Systems 13


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A B

575
415 633
390,5 390,5
Automatic swing

3 266
door systems

302 3
142 131
78 78
1 1

ø16
ø16

120 428,5 120 428,5


2

A = Installation with mounting plate


B = Direct installation
1 = Concealed line-feed for low-voltage connection and mains cable
2 = Dimensional reference is middle of hinge
3 = Concealed line-feed for low-voltage connection

Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70107-ep02
Soffit depth (max.) 30 mm

5 60
16
44*

1
60
42

16
10
30*
33

35
72

3
84

* = Direct installation
1 = ECturn space requirement
2 = Guide rail space requirement
3 = GC 334 space requirement

14 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A B

575
415 633
390,5 390,5

Automatic swing
266

door systems
1 302
142 1 131
78 78

ø16
2 2

ø16

ø16
498,5 70 498,5 70

3 3

A = Installation with mounting plate


B = Direct installation
1 = Concealed line-feed for low-voltage connection
2 = Concealed line-feed for low-voltage connection and mains cable
3 = Dimensional reference is middle of hinge

Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70107-ep03
Soffit depth (max.) 200 mm

60
5
16

1
44*
42

60
16
34*
35

26

34
75

3
86

* = Direct installation
1 = ECturn space requirement
2 = Link arm space requirement
3 = GC 334 space requirement

Swing Door Systems 15


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A B

575
415 633
390,5 390,5
Automatic swing

1 302 266
door systems

1
142 131
78 78
2 2

ø16

ø16
42,5 287 42,5 287

3 3

A = Installation with mounting plate


B = Direct installation
1 = Concealed line-feed for low-voltage connection
2 = Concealed line-feed for low-voltage connection and mains cable
3 = Dimensional reference is middle of hinge

Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70107-ep04
Door overlap (max.) 50 mm

60
35
24
32*
33

16

110
42

60
44*

16
99

* = Direct installation
1 = Guide rail space requirement
2 = ECturn space requirement
3 = GC 334 space requirement

16 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A B
1

120 428,5 120 428,5

Automatic swing
door systems
ø16
2 2
ø16

78 78
142 131

302 266
390,5 3 390,5 3
1
415 633

575

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for low-voltage connection and mains cable
3 = Concealed line-feed for low-voltage connection

Door leaf installation with link arm on the hinge side, single-leaf

Door overlap (max.) 200 mm

5 60

1
34
26
34*
35

16
44*

2
60
42

16

110

3
99

* = Direct installation
1 = ECturn space requirement
2 = Link arm space requirement
3 = GC 334 space requirement

Swing Door Systems 17


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A B

1 1

287 42,5 3 287 42,5 3


Automatic swing
door systems

ø16
2 2
ø16

78
78
142 131

302 266
390,5 390,5
415
633
575

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for low-voltage connection and mains cable
3 = Concealed line-feed for low-voltage connection

Door leaf installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70107-ep05
Soffit depth (max.) 20 mm

5 60 1
35
32*
33

16
42
44*

60
16

99

2
110

* = Direct installation
1 = Guide rail space requirement
2 = ECturn space requirement
3 = GC 334 space requirement

18 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE ECturn

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A B

1 2 1 2

Automatic swing
door systems
498,5 100 498,5 100

3 3

ø16

ø16
58 58
122
282 111
370,5 246
395
370,5
555
613

A = Installation with mounting plate


B = Direct installation
1 = Concealed line-feed for low-voltage connection
2 = Dimensional reference is middle of hinge
3 = Concealed line-feed for low-voltage connection and mains cable

Legend for the cable diagrams

Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG
4 = J-Y(ST)Y 4 x 2 x 0.6 LG
5 = LiYY 2 x 0.25 mm2
6 = LiYY 4 x 0.25 mm2
7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2
8 = Route empty pipe with pull-wire inner diameter 10 mm

Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (included in the scope of supply for sensor strip)
2) Cable exit for door drive, see installation drawings for ECturn 70107-ep01 to -ep06
3) Cable including in the scope of supply for the sensor
4) + 5) Connection box for mains supply and control cable combined on site. Mains supply and control cable must be wired in separate ter-
minal spaces.
4) Mains connection box WxHxD min. 65 x 65 x 57
5) Control cable box WxHxD min. 94 x 65 x 57 with PG-11 duct

Abbreviations
HS = Main switch
NOT = Emergency-stop switch
KB = Contact sensor authorised
PS = Programme switch
ST = Emergency stop
KI = Contact sensor inside
KA = Contact sensor outside
TOE = Door opener
RM = Bar message

Swing Door Systems 19


Automatic swing door systems

GEZE ECturn

I
ECturn, EMD,
TSA 160 NT

II
III
B+200 4)
A

5)
IV
B KI
Automatic swing
door systems

B
1 1 1 1 3 3 3 3 3 ECturn
8 8 KA

max. 300
max. 100

B/2

B/2
HS NOT KB PS ST KI KA
V V 3) 3)

I = Mains supply cable 230 V / 50 Hz


II = Fuse 10 A
III = Connected load 230 W 1 A
IV = And / Or
V = Option

1-leaf

I II

A A
4)

B B 5)
1
ECturn 2)
7 ECturn 2)
8
GC 334 GC 334
1)

8 8
TOE TOE
RM RM

I = Transom installation concealed line-feed


II = Door leaf installation

20 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

GEZE swing door drive Slimdrive EMD

ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1 and 2-leaf single-action doors

The electromechanical swing door drive GEZE Slimdrive EMD stands out due to its numerous areas of application. The compact drive is only
7 cm high and can move large and heavy internal and external doors comfortably and quietly. This makes the Slimdrive EMD the ideal solution

Automatic swing
door systems
wherever efficiency has to be coupled with silent running. State-of-the-art control technology combined with a low-wear and maintenance-
free high-power motor guarantees reliable operation even for doors which are heavily frequented. All door parameters e.g. opening and
closing speed as well as latching action, can be optimally adapted. Manual door opening can be supported by the drive (servo function) and
ensures that even heavy doors can be opened more easily manually. The push & go function can be activated on request, i.e. the door is only
slightly opened by hand and the automatic actuation opens the door completely. In low-energy mode, the drive moves the door at reduced
speed. The optional CAN interface can be used to meet demanding requirements e.g. air lock control.

GEZE Slimdrive EMD

GEZE Slimdrive EMD

650
8 121
72
113

30
710

Application range •• Internal and external doors


•• Railway stations and airports
•• Hotel and restaurants
•• Hospitals and nursing homes for the elderly
•• Educational institutions e.g. schools, nursery schools, day care centres
•• Leisure facilities, e.g. swimming baths, thermal baths, sport and fitness centres
•• Administration and public buildings
•• Food industry

Swing Door Systems 21


Automatic swing door systems

GEZE Slimdrive EMD


Technical data

Product features

GEZE Slimdrive

GEZE Slimdrive

GEZE Slimdrive

GEZE Slimdrive
EMD Invers
ECturn, EMD,
TSA 160 NT

EMD F-IS
EMD-F
EMD
Automatic swing

Height 70 mm
door systems

Width 650 mm
Depth 121 mm
Leaf weight (max.) 1-leaf 180 kg 230 kg
Hinge size (min.-max.)* 2-leaf 1500 – 2800 mm
Leaf width (min.-max.)* 750 – 1400 mm
Soffit depth (max.)* 400 mm
Door overlap (max.)* 30 mm
Drive type Electromechanical
Door opening angle (max.)* 115 °
Spring pre-load EN3 – EN6
Left-hand ● ● ● ●
Right-hand ● ● ● ●
Transom installation opposite hinge side with link arm ● ● ● ●
Transom installation opposite hinge side with guide rail ● ● ● ●
Transom installation hinge side with guide rail ● ● ● ●
Door leaf installation opposite hinge side with guide rail - - - -
Door leaf installation hinge side with guide rail ● ● ● ●
Door leaf installation hinge side with link arm - - - -
Mechanical latching action - ● ● -
Electrical latching action ● ● ● ●
Electrical closing sequence control ● ● ● ●
Mechanical closing sequence control - - ● -
Disconnection from mains Cable plug connection
Activation delay (max.) 20 S
Operating voltage 230 V
Frequency of supply voltage 50 – 60 Hz
Capacity rating 230 W
Power supply for external consumers (24 V DC) 1200 mA
Temperature range -10 – 50 °C
Enclosure rating IP 20
Operating modes Off, Automatic, Permanently open, Shop closing, Night
Type of function Fully automatic
Automatic function ● ● ● ●
Low-energy function ● ● ● ●
Servo function - ● ● ●
Key function ● ● ● ●
Inverse function (opening by spring force) - - - ●
Draught-proofing ● ● ● ●
Obstruction detection ● ● ● ●
Automatic reversing ● ● ● ●
Push & go adjustable
Operation Programme switch DPS, Programme switch MPS,
Programme switch TPS, Programme switch integrated in the drive
Parameter setting Programme switch DPS
CAN interface optional
Approvals DIN 18650 DIN 18650 DIN 18650 DIN 18650
DIN 18263-4 DIN 18263-4
Closing
sequence cont-
roller tested acc.
to EN 1158
Suitable for fire proof doors - ● ● -
● = yes Note: The maximum possible leaf weight in relation to leaf width can be found in the
- = not available chapter on areas of application (diagrams)!
* = depending on the type of installation

22 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Overview of torques Slimdrive EMD-F

ECturn, EMD,
TSA 160 NT
Type of Installation Transom Installation Door leaf Installation Transom Installation opposite hinge side
hinge side (min.-max.) hinge side (min.-max.) (min.-max.)
Linkage element guide rail guide rail guide rail link arm
Spring pre-load Closer
3-5 3-5 3-5 4-6

Automatic swing
size EN 1154

door systems
Closing torques 20 - 45 Nm 17 - 43 Nm 20 - 45 Nm 35 - 70 Nm
Opening torques,
122 - 97 Nm 125 - 96 Nm 115 - 90 Nm max. 150 Nm
automatic
Opening torques,
45 - 66 Nm 50 - 73 Nm 42 - 65 Nm 61 - 88 Nm
manual
Note: For automatic mode, the doors must be equipped with suitable hinges. A door stop is necessary.

Hinge dimensions for double-leaf systems (with / without IS)

Type of installation Hinge clearance


Transom installation hinge side max. 2800 mm,
min. 1700 mm max. 2500 mm
with guide rail not fire protection doors
Transom installation opposite max. 2800 mm,
min. 1700 mm max. 2500 mm
hinge side with guide rail not fire protection doors
Transom installation opposite
min. 1500 mm max. 2800 mm max. 2800 mm
hinge side with link arm
Single-leaf widths depending on leaf weight, see diagrams for areas of application

Areas of application

Note
In low-energy mode the swing door drive moves at reduced speed and thus meets the safety requirement of DIN 18650. The use of safety sen-
sors to safeguard the system is only necessary in individual cases, taking the user group into account. In automatic mode, however, the swing
area of the door must always be safeguarded with safety sensors.

Slimdrive EMD
Y 240
220
200
180
160
140
120
100
1 2
80
60
40
20
0
700 800 900 1000 1100 1200 1300 1400 X

X = Door width (mm)


Y = Door weight (kg)
1 = Link arms
2 = Guide rail

Swing Door Systems 23


Automatic swing door systems

GEZE Slimdrive EMD

Slimdrive EMD-F
ECturn, EMD,
TSA 160 NT

Y 240
230
220
200
180
1
160
Automatic swing
door systems

140
2
120
100
80
60
40
20
0
700 800 900 1000 1100 1200 3 1300 1400 X

X = Door width (mm)


Y = Door weight (kg)
1 = Link arms
2 = Guide rail
3 = Use of fire protection limit for guide rail

Note
We recommend the use of link arms for external doors. Wind loads and underpressure or excess pressure must also be taken into account.
Dimensions marked by an asterisk (*) are valid for direct attachment.

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Transom installation with guide rail on the hinge side, single-leaf


Drawing no. 70106-ep01
Door overlap (max.) 30 mm
Door opening angle (max.) 105°

8 121
14
51,2*

14

1
95
14

*
38
43

10

20
50

2
3
70

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

24 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A B

620 620 3
577 540
394 3 412 max. 20
1 256 1 274

Automatic swing
73 30

door systems
30 14

max. 20
max. 20

2
2

89 698
89 698

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70106-ep02
Soffit depth (max.) -30 to +50 mm
Door opening angle (max.) 105°

8 121
14
51,2 *

1
75
14
14
38 *

43

29

39

3
70

90

39
39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Swing Door Systems 25


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A B

636
598 2 598
577 376
394 238
256
Automatic swing

2 1 max. Ø 20
110
door systems

max. Ø 20 73 1
52 52

3
3

max. Ø 20

max. Ø 20
698 82
698 82
4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70106-ep03
Soffit depth (max.) 0-100 mm, 100-200 mm, 200-300 mm
Door opening angle (max.) 110°

8 121
14
51,2*

1
14

75
14

43*
48

34

47
75

3
95

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

26 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A B

598
577 636
2
2 394 376
max. Ø 20 256 238
1

Automatic swing
73 max. Ø 20 110

door systems
1
52 52

3 3

max. Ø 20

max. Ø 20
44 417 44 417

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep04
Door overlap (max.) 30 mm
Door opening angle (max.) 115°

8 121 2
39
29

38 *
43
14

1
51.2 *
14

70
14

3
100

120

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Swing Door Systems 27


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A B
69 748
69 748
666
628 628
607 406
424 268
Automatic swing

286 Ø 20 1 Ø 20
1
door systems

103 2 140 2
82 82
Ø 20

Ø 20
3 3

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Transom installation with guide rail on the hinge side, double-leaf


Drawing no. 70106-ep21

8 121
14
51,2*

14

1
95
14
43
38*
10

20
50

2
3
70

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

28 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
721 A 721
620 620
577 577
394 394
256 Ø 20 2 256
73 73
30 30
3
Ø 20

Automatic swing
door systems
89 698 698 89

4 4
1 1
5

662
662 B 620
620 540
540 412
412 274
274 Ø 20 2
30 30
3 14 14
Ø 20

89 698 698 89

4 4
1 1
5

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

Transom installation with guide rail on the opposite hinge side, double-leaf
Drawing no. 70106-ep22

8 121
14
51,2*

1
72
14
14
38*
43

29

39

3
70

90

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Swing Door Systems 29


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

721 721
598 A 598
577 577
394 394
1 256 256 1
73 Ø 20 3 73
52 52
Automatic swing

Ø 20
door systems

698 82
82 698

4 4
5

662 662
636 636
598 B 598
376 376
238 Ø 20 3 238 1
1 110
110
52 52
Ø 20

82 698 698 82

4 4
5

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70106-ep23

8 121
14
51,2*

1
14

75
14

43*
48

34

47
75

3
95

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

30 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)

ECturn, EMD,
TSA 160 NT
A
721 721
598
598 577
577 394
1 394 1
256 Ø 20 256
73 2 73
3 52 52

Automatic swing
door systems
Ø 20

417 44 44 417

4 4
5

662 662
636 B 636
598 598
376 376
238 Ø 20 238
1 110 2 110 1
3 52 52
Ø 20

417 44 44 417

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

Door leaf installation with guide rail on the hinge side, double-leaf
Drawing no. 70106-ep24

8 121 2
39
29

38*
43
14

1
51.2*
14

70
14

3
100

120

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Swing Door Systems 31


Automatic swing door systems

GEZE Slimdrive EMD

Installation with mounting plate (A) and direct installation (B)


ECturn, EMD,
TSA 160 NT

A
69 748 748 69
628 628
607 607
424 424
286 Ø 20 286
1 103 2 1
103
82 82

Ø 20
Automatic swing
door systems

4 4
5

69 748 B 748 69
666 666
628 628
406 406
1 268 268 1
140 Ø 20 140
2
82 82

Ø 20
3

4 4
5

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

GEZE Slimdrive EMD

32 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE Slimdrive EMD

Legend for the cable diagrams

ECturn, EMD,
TSA 160 NT
Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG

Automatic swing
door systems
4 = J-Y(ST)Y 4 x 2 x 0.6 LG
5 = LiYY 2 x 0.25 mm2
6 = LiYY 4 x 0.25 mm2
7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2
8 = Route empty pipe with pull-wire inner diameter 10 mm

Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not permitted for
fire protection doors.
2) Cable exit for door drive, see installation drawings for Slimdrive EMD/EMD-F 70106-ep01 to -ep04
3) Cable including in the scope of supply for the sensor
4) Install in the direct vicinity of the door
5) Mains connection box WxHxD min. 65 x 65 x 57 with PG-11 duct, on site
6) Low-voltage connection box WxHxD min. 94 x 65 x 57 with PG-11 duct, on site
7) E.g. door transmission cable, 8-wire, art. no. 066922
8) Branch box, on site

Abbreviations
HS = Main switch
NOT = Emergency-stop switch

UT = Circuit breaker CLOSE DOOR (only with F variant)


KB = Contact sensor authorised
PS = Programme switch
ST = Emergency stop
KI = Contact sensor inside
KA = Contact sensor outside
TOE = Door opener
RM = Bar message
RS = Smoke switch (only with F variant)
RSZ = Smoke switch control unit (only with F variant)
TS = Door closer
MK = Magnetic contact

Swing Door Systems 33


Automatic swing door systems

GEZE Slimdrive EMD


ECturn, EMD,

I
TSA 160 NT

II
III
B+200 5)
A
B
C 6)
D/D* KI
Automatic swing

IV
door systems

B
1 1 1 1 2 2 3 3 3 3 3 EMD/EMD-F
8 8 KA

max. 300
max. 100

B/2

B/2
HS NOT UT KB PS ST KI KA
V V 4) 3) 3)

I = Mains supply cable 230 V / 50 Hz


II = Fuse 10 A
III= Connected load 230 W, 1 A 1-leaf,
2-leaf with manual fixed leaf, connec-
ted load 460 W, 1 A for 2-leaf
IV = And / Or
V = Option

1-leaf

I II
A A
RS 3 RS 3 RS 3 RS 3
B RSZ 1 8) B RSZ 1 5)
C C

D D 6)
2 1
EMD/EMD-F 2)
7 EMD/EMD-F 2)
8
GC 334 GC 334
1)
3 3
8 8
TOE TOE
RM RM

2-leaf

I II
A
RS 3 RS 3 A
B RSZ 1 8) RS 3 RS 3
B RSZ 1
1 5) 1 5)
C C 3 8
6) 6)
D D* 3 8 D
3 8
3 8 TOE
2 1 RM
2) TOE 2)
EMD/EMD-F EMD/EMD-F
D
* RM EMD/EMD-F 2) 7 EMD/EMD-F 2)
8 7
GC 334 GC 334 GC 334 GC 334
4
7 1)
8 6

7) 6 TOE
RM
TOE
RM III IV
III IV

I = Transom installation
II = Door leaf installation
III = Fixed leaf
IV = Active leaf

34 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE EMD Invers

GEZE swing door drive Slimdrive EMD Invers

ECturn, EMD,
TSA 160 NT
Electromechanical swing door drive for 1-leaf and 2-leaf single-action doors (RWA fresh air supply and doors in emergency exit
routes)

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Automatic swing
door systems
Transom installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep01

8 121
14
51,2*

14

95
14

*
38
43

10

20
50

2
3
70

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

A B
620 636
577 620
1 394 1 376
256 max. Ø 20 2 238 max. Ø 20 2
73 110
30 30
3 3
54
54
max. Ø 20

max. Ø 20

75 748 75 748
4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Swing Door Systems 35


Automatic swing door systems

GEZE EMD Invers

Transom installation with guide rail on the opposite hinge side, single-leaf
Drawing no. 70106-ep02
ECturn, EMD,
TSA 160 NT

8 121
Automatic swing
door systems

14
51,2 *

75
14
14
38 *

43

29

39
3
70

90
2

39
39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

A B
598
577 598
394 540
256 412
73 274 1
max. Ø 20 1 max. Ø 20 52
3 52 3
14
2 2
35

35

max. Ø 20
max. Ø 20

748 75
748 75

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

36 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE EMD Invers

Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70106-ep03

ECturn, EMD,
TSA 160 NT
8 121

Automatic swing
door systems
14
51,2*

1
14

75
14

43*
48

34

47
75

95
2

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

A B
577 1 540
394 412
256 1
274
73
3 3 14
2 2
max. Ø 20
max. Ø 20

44 417 44 417

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

Swing Door Systems 37


Automatic swing door systems

GEZE EMD Invers

Door leaf installation with guide rail on the hinge side, single-leaf
Drawing no. 70106-ep04
ECturn, EMD,
TSA 160 NT

8 121 2
Automatic swing
door systems

39
29

38 *
43
14

1
51.2 *
14

70
14

3
100

120
39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

A B
75 748 75 748
628 628
607 570
1 424 442
286 1
304
103 max. Ø 20 max. Ø 20 2
2 82
82 44

3 3
35
35

max. Ø 20
max. Ø 20

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width

38 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE EMD Invers

Transom installation with guide rail on the hinge side, double-leaf


Drawing no. 70106-ep21

ECturn, EMD,
TSA 160 NT
8 121

Automatic swing
door systems
14
51,2*

14

95
14
43
38*
10

20
50

2
3

70
39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

721 A 721
620 620
1 577 577 1
394 394
256 max. Ø 20 3 256
73 73
30 30
2
54
max. Ø 20

4 4
5
662 B 662
636 636
1 620 620 1
376 376
238 238
110 110
30 30

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

Swing Door Systems 39


Automatic swing door systems

GEZE EMD Invers

Transom installation with guide rail on the opposite hinge side, double-leaf
Drawing no. 70106-ep22
ECturn, EMD,
TSA 160 NT

8 121
Automatic swing
door systems

14
51,2*

72
14
14
38*
43

29

39
3
70

90
2

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

721 A 721
598
598 577
577
394 394 1
1 max. Ø 20 256
256 2
73 73
52 52
max. Ø 20

417 44 44 417

4 4
5

662 662
598 598
540 B 540
412 412
1 274 274
max. Ø 20 52 1
52 2
14 14
max. Ø 20

417 44 44 417

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

40 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE EMD Invers

Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70106-ep23

ECturn, EMD,
TSA 160 NT
8 121

Automatic swing
door systems
14
51,2*

1
14

75
14

43*
48

34

47
75

95
2

39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

721 A 721
598
598 577
577
394 394 1
1 max. Ø 20 256
256 2
73 73
52 52
max. Ø 20

417 44 44 417

4 4
5

662 662
598 598
540 B 540
412 412
1 274 274
max. Ø 20 52 1
52 2
14 14
max. Ø 20

417 44 44 417

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

Swing Door Systems 41


Automatic swing door systems

GEZE EMD Invers

Door leaf installation with guide rail on the hinge side, double-leaf
Drawing no. 70106-ep24
ECturn, EMD,
TSA 160 NT

8 121 2
Automatic swing
door systems

39
29

38*
43
14

1
51.2*
14

70
14

3
100

120
39 39

* = Direct installation
1 = EMD-F/EMD Invers space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Installation with mounting plate (A) and direct installation (B)

75 748 A 748 75
628 628
607 607
424 424
1 286 Ø 20 286
103 2 1
103
82 82
Ø 20

4 4
5
69 748 748 69
B
628 628
570 570
442 442
1 304 304 1
82 2 Ø 20 82
44 44

4 4

A = Installation with mounting plate


B = Direct installation
1 = Dimensional reference is middle of hinge
2 = Concealed line-feed for sensors, door openers, programme switches and lock switch contact
3 = Concealed cable line-feed 230 V / 50 Hz
4 = Door leaf width
5 = Hinge clearance

42 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

GEZE swing door drive TSA 160 NT

ECturn, EMD,
TSA 160 NT
Electrohydraulic swing door drive for 1 and 2-leaf single-action doors

The TSA 160 NT is an electronically controlled hydraulic swing door system for single-action doors made of wood, steel, aluminium or plastic
with leaf weights of up to 310 kg and leaf widths up to 1600 mm. The drive works with a hydraulic pump system during opening. The closing

Automatic swing
door systems
process is by means of a closing spring mechanism and adjustable hydraulic valves. The TSA 160 NT also has low power consumption and is
low-maintenance. The door can be opened by hand in the event of a power failure. Manual opening is also possible with with motor operation
switched on. A reinforced and highly stable link arm meets the requirements of large and heavy doors which are highly frequented. The TSA
160 NT masters large amounts of foot traffic reliably and easily.

GEZE TSA 160 NT

GEZE TSA 160 NT

690
8 121
100
150

30
465

Application range •• Internal and external doors


•• Railway stations and airports
•• Hotel and restaurants
•• Hospitals and nursing homes for the elderly
•• Department stores and shopping centre
•• Educational institutions e.g. schools, nursery schools, day care centres
•• Leisure facilities, e.g. swimming baths, thermal baths, sport and fitness centres
•• Administration and public buildings
•• Food industry

Swing Door Systems 43


Automatic swing door systems

GEZE TSA 160 NT


Technical data

Product features

GEZE TSA 160 NT IS


GEZE TSA 160 NT

GEZE TSA 160 NT

GEZE TSA 160 NT


ECturn, EMD,
TSA 160 NT

Invers

EN7
Automatic swing
door systems

Height 100 mm
Width 690 mm
Depth 121 mm
Leaf weight (max.) 1-leaf 250 kg 310 kg
Hinge size (min.-max.) 2-leaf 1470 – 2800 mm 1470 – 3200 mm
Leaf width (min.-max.) 690 – 1400 mm 690 – 1600 mm
Soffit depth (max.)* 400 mm
Door overlap (max.)* 20 mm
Drive type Electrohydraulic
Door opening angle (max.)* 115 °
Spring pre-load EN3 – EN6** EN7
Z-variant (pulling) ● - ● ●
Z-variant (pushing) - ● - -
Left-hand ● ● ● ●
Right-hand ● ● ● ●
Transom installation opposite hinge side with link arm ● ● ● ●
Transom installation opposite hinge side with guide rail - - - -
Transom installation hinge side with guide rail ● ● ● ●
Door leaf installation opposite hinge side with guide rail - - - -
Door leaf installation hinge side with guide rail - - - -
Door leaf installation hinge side with link arm - - - -
Mechanical latching action ● - ● ●
Electrical latching action - - - -
Electrical closing sequence control ● ● ● ●
Mechanical closing sequence control - - ● -
Disconnection from mains Not available
Activation delay (max.) 10 S
Operating voltage 230 V
Frequency of supply voltage 50 – 60 Hz
Capacity rating 300 W 400 W
Power supply for external consumers (24 V DC) 1200 mA
Temperature range -10 – 60 °C
Enclosure rating IP 20
Operating modes Off, Automatic, Permanently open, Shop closing, Night
Type of function Fully automatic
Automatic function ● ● ● ●
Low-energy function - - - -
Servo function - - - -
Key function ● ● ● ●
Inverse function (opening by spring force) - ● - -
Draught-proofing ● ● ● ●
Obstruction detection ● ● ● ●
Automatic reversing ● ● ● ●
Push & go adjustable
Operation Programme switch DPS, Programme switch MPS,
Programme switch TPS, Programme switch integrated in the drive
Parameter setting Programme switch DPS, Controller
Approvals DIN 18650
Suitable for fire proof doors - - - -
Use on smoke and fire doors (F-variant) ● - ● -
● = yes
- = not available
* = depending on the type of installation
** = This does not apply for Z-variant

44 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

Overview of torques TSA 160 NT

ECturn, EMD,
TSA 160 NT
pushing (min.-max.) pulling (min.-max.)
Spring pre-load
3-6 -
Closer size EN 1154
Closer torques:

Automatic swing
door systems
torque exerted by the closing spring 20 Nm - >60 Nm 8 Nm - 30 Nm
during automatic opening
Opening torque:
torque exerted by the door 150 Nm - 90 Nm 70 Nm - 40 Nm
during automatic opening
Opening torque:
manual torque to be exerted for door 35 Nm - 110 Nm 13 Nm - 45 Nm
opening

TSA 160 NT minimum and maximum leaf widths

Single-leaf doors Leaf width (min.) Leaf width (max.)


TSA 160 NT pushing1) 690 mm 1400 mm
950 mm (with operator displacement=0)
TSA 160 NT pulling 1400 mm
890 mm (with operator displacement=60 mm)
TSA 160 NT Z 690 mm 1400 mm
Also on smoke and fire protection doors
1)

TSA 160 NT minimum and maximum leaf widths, hinge size for double-leaf doors

Leaf width (min.) Leaf width (min.)


Double-leaf doors Hinge size (min.) Hinge size (max.) Leaf width (max.)
active leaf2) fixed leaf2)
TSA 160 NT IS
1470 mm 2800 mm 690 mm 400 mm 1400 mm
pushing1)
TSA 160 NT Z-IS
1470 mm 2800 mm 690 mm 650 mm 1400 mm
pulling
TSA 160 NT IS/TS
1260 mm 2800 mm 690 mm 400 mm 1400 mm
pushing1)
TSA 160 NT IS/TS
1360 mm 2800 mm 690 mm 650 mm 1400 mm
pulling
1)
Also on smoke and fire protection doors
2)
The minimum hinge width must be observed!

Swing Door Systems 45


Automatic swing door systems

GEZE TSA 160 NT

Areas of application
ECturn, EMD,
TSA 160 NT

TSA 160 NT
Y 300
Automatic swing
door systems

250

200
1

150
2

100

50
700 800 900 1000 1100 1200 1300 1400 X

X = Door width (mm)


Y = Door weight (kg)
1 = Link arms
2 = Guide rail

TSA 160 NT E7
Y 350

310
300

250
1

200

2
150

100

50
700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 X

X = Door width (mm)


Y = Door weight (kg)
1 = Link arms
2 = Guide rail

46 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

ECturn, EMD,
TSA 160 NT
Transom installation with guide rail on the hinge side, single-leaf
Drawing no. 70423-ep02

Automatic swing
door systems
8* 121
29*
22*
54

119
1
29*
29* 42
63

50

31

31
3

80

* = Installation with mounting plate


1 = TSA 160 NT space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

A B

20 650
625 487.5
Ø 20 325 Ø 20 1
34 420 Ø 20 1 162.5
1
Ø 20
1
48

50

186 453 186 453

50 587
50 587

A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed

Swing Door Systems 47


Automatic swing door systems

GEZE TSA 160 NT


ECturn, EMD,
TSA 160 NT

1
Automatic swing
door systems

453 X

1 = Mounting plate

Transom installation with link arm on the opposite hinge side, single-leaf
Drawing no. 70423-ep01

121 8*

29*

1
54
22*
100

29*
4

27+X

41*

2
40

3
39
85

* = Installation with mounting plate


1 = TSA 160 NT space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

48 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

650

ECturn, EMD,
TSA 160 NT
487.5
325
20 162.5 625
Ø 20 1 Ø 20 1 34 420 Ø 20 1
29 22 29

Ø 20 1

Automatic swing
50

door systems
48
587
10

587

44 44
50
50
335
335

A B

A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
Transom installation with guide rail on the hinge side, double-leaf
Drawing no. 70423-ep22

8* 121
29*

1
22*
54

119
29*
42

29
50

2
31
60

80

* = Installation with mounting plate


1 = TSA 160 NT space requirement
2 = Guide rail space requirement
3 = GC 338 space requirement

Swing Door Systems 49


Automatic swing door systems

GEZE TSA 160 NT

A 625
ECturn, EMD,

625
TSA 160 NT

34 420 Ø 20 420 34
1
Ø 20
1

48
453 186
50 587
Automatic swing
door systems

186 453

B
2 B/2
650 650
1 Ø 20 487.5 487.5
325 Ø 20 325
20 162.5 1 162.5 20
50

453 186
50 587

186 453

A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
2 = only required if B>2000

Transom installation with link arm on the opposite hinge side, double-leaf
Drawing no. 70423-ep11

121 8*
29*

1
100

22*

54
29*

51
55
X

86

2
40

39
85

max. 350

X = Spindle extension
* = Installation with mounting plate
1 = TSA 160 NT space requirement
2 = Link arm space requirement
3 = GC 338 space requirement

50 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

ECturn, EMD,
TSA 160 NT
625 625
34 420 Ø 20 420 34
1

Ø 20 1

48

Automatic swing
587

door systems
50 44 44

335 335

B /2 2
650 650
487.5 487.5
325 325
20 162.5 Ø 20 162.5 20
Ø 20 1 1
50

587

50 44 44

335 335

A = Direct installation
B = Installation with mounting plate
1 = Concealed line-feed
2 = only required if B>2000

TSA 160 NT

Soffit depth L Dimension X for guide rail


Door width (min.) Opening angle
(from-to) with TSA 160 NT Z
> 0 - 25 mm 186 mm 690 mm 109° - 113°
> 25 - 50 mm 192 mm 690 mm 113° - 115°
> 50 - 75 mm 203 mm 690 mm 115° - 110°
> 75 - 100 mm 215 mm 690 mm 110° - 105°
> 100 - 125 mm 229 mm 690 mm 105° - 100°
> 125 - 150 mm 244 mm 703 mm 100° - 97°
> 150 - 175 mm 262 mm 721 mm 97° - 95°
> 175 - 200 mm 280 mm 739 mm 95° - 90°

Swing Door Systems 51


Automatic swing door systems

GEZE TSA 160 NT

Legend for the cable diagrams


ECturn, EMD,
TSA 160 NT

Cable
1 = NYM-J 3 x 1.5 mm2
2 = J-Y(ST)Y 1 x 2 x 0.6 LG
3 = J-Y(ST)Y 2 x 2 x 0.6 LG
Automatic swing

4 = J-Y(ST)Y 4 x 2 x 0.6 LG
door systems

5 = LiYY 2 x 0.25 mm2


6 = LiYY 4 x 0.25 mm2
7 = Scope of supply sensor strip or LiYY 5 x 0.25 mm2
8 = Route empty pipe with pull-wire inner diameter 10 mm

Operator displacement
AV = Cable exit
60 mm = 580 mm
50 mm = 590 mm
40 mm = 600 mm (standard)
30 mm = 610 mm
20 mm = 620 mm
10 mm = 630 mm
0 mm = 640 mm

Notes
•• Cable diagrams can also be prepared for specific building projects after receipt of order
•• Version of standard cable diagrams in accordance with GEZE specifications
•• Cable routing according to VDE 0100
•• Allow the cable for the drive to project at least 1500 mm out of the wall

1) Door transmission cable (including in the scope of supply for sensor strip), cable routing through a hole in the door leaf is not
permitted for fire protection doors.
2) Cable exit for door drive see sketch A and B
3) Cable including in the scope of supply for the sensor
4) Install in the direct vicinity of the door
7) E.g. door transmission cable, 8-wire, art. no. 066922
8) Branch box, on site

Abbreviations
HS = Main switch
NOT = Emergency-stop switch
UT = Circuit breaker CLOSE DOOR (only with F variant)
KB = Contact sensor authorised
PS = Programme switch
ST = Emergency stop
KI = Contact sensor inside
KA = Contact sensor outside
TOE = Door opener
RM = Bar message
RS = Smoke switch (only with F variant)
RSZ = Smoke switch control unit (only with F variant)
TS = Door closer
MK = Magnetic contact

52 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

GEZE TSA 160 NT

ECturn, EMD,
TSA 160 NT
I
II
III

A
B
C

Automatic swing
door systems
D/D*
IV

1 1 1 1 2 2 3 3 3 3 3
8 8

HS NOT UT KB PS ST KI KA
V V 4) 3) 3)

I = Mains supply cable 230 V / 50 Hz


II = Fuse 10 A
III= Connected load 300 W 1.3 A for1-
2-leaf with manual fixed leaf Connec-
ted load 600 W 2.6 A for 2-leaf
IV = And / Or
V = Option

Positioning of the movement detectors

I II III

B+200 B+200

B+200
B+200
B/2
B
KI KI BWM
B

2xB

KA
B

KA
B
BWM
B/2
B/2

I = Positioning of the movement detector 1-leaf


II = Positioning of the movement detector 2-leaf
III = Positioning of the movement detector 2-leaf, 2E

Swing Door Systems 53


Automatic swing door systems

GEZE TSA 160 NT

TSA 160 NT cable plan single-leaf


ECturn, EMD,
TSA 160 NT

A
RS 3 RS 3
B RSZ 1 8)
C

D
Automatic swing
door systems

2 1
TSA 160 NT 2)
8
GC 334
1)
3
8
TOE
RM

TSA 160 NT cable plan double-leaf

I II
A A
RS 3 RS 3 RS 3 RS 3
B RSZ 1 8) B RSZ 1 8)
1 C
8)
C D
D
3 8 2 3
3 8 2 1
2 1 3 2 MK 8 8
TOE
TS TOE TSA 160 NT 2)
* TSA 160 NT 2) RM TSA 160 NT 2) 8 RM
D 8
8 GC 334
4 GC 334 GC 334 7) 1)
7 1) 6
8

7) 6 TOE
TOE RM
RM
III IV
III IV

I = 2-leaf
II = 2-leaf with manual fixed leaf
III = Fixed leaf
IV = Active leaf

TSA 160 NT cable exit

I II III

VII VII VII VII VII VII


600 600 50 50
VI VI 50 VI VI 50 VI
VI ø 20 ø 20 AV=40
AV=40 ø20 ø 20 ø 20 ø 20
68

68

54

68
54

68

IV V IV V IV V

AV = Operator displacement
I = TSA 160 NT installation, hinge side
II = TSA 160 NT installation, opposite hinge side
III = TSA 160 NT-Z installation, hinge side
IV = Drive left - pulling
V = Drive right - pulling
VI = from top of leaf, dimension for spindle extensions must be added
VII = Cable exit

54 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

Accessories

Accessories for swing door systems

ECturn, EMD,
TSA 160 NT
Hood, mounting plate, link arm, guide rail with lever

Hood
The hood is available in an anodised or coloured finish. In the case of double-leaf versions, the hood can be ordered as a continuous variant or

Automatic swing
door systems
with intermediate hood.

Mounting plate for drives (option)


A mounting plate may be necessary, depending on the installation situation. A mounting plate is generally recommended to make installation
easier. A respective mounting plate is supplied according to the hood version.

Link arms
are offered for different soffit depths

Guide rail with lever


Installation depends on the type of hinge action chosen.

Cover Mounting plate Link arms

Guide rail with lever

Note
More detailed information about the following accessories can be found in the catalogue: GEZE actuation devices and sensor systems

Swing Door Systems 55


Automatic swing door systems

Accessories

Operating automatic swing doors


ECturn, EMD,
TSA 160 NT

Programme switches for the selection of the operating mode for automatic swing doors

GEZE offers programme switches for a wide range of individual requirements. The switches are suitable for universal use – for surface-mounted
or flush-mounted installation. The following switch types are available:
Automatic swing
door systems

Display programme switch (DPS)


Key programme switch (TPS)
Mechanical programme switch (MPS)

The following operating modes can be set:

“Permanently open”
The door moves to the OPEN position and remains open. Movement detector or opening button are deactivated.

“Night”
The movement detectors are switched inactive, the door closes.
Option: The door leaves are locked electrically to prevent forced opening.

“Shop closing” (one-way)


The door only opens and closes when someone goes out from the inside.
The movement detector outside is switched inactive, the one inside is switched active.

“Automatic”
The door opens as soon as it is actuated via the movement detector or keys, and closes after a certain individually adjustable time. Safety sen-
sors protect the leaves’ travel path. If there is someone in the door opening, the door will not close.

“OFF” (only with TPS and MPS)


Drive and sensors are switched off, the door leaves can be moved manually.

Key switch
The programme switch can be blocked using a key switch. A key switch is required for the FR variants.

Securing the programme switches


The mechanical programme switch (MPS) is also available in a lockable version. The display programme switch (DPS) and key programme
switch (TPS) can be combined with a key switch. Alternatively, these programme switches can be secured using a code.

Display programme switch (DPS) Key programme switch (TPS) Mechanical programme switch (MPS)

56 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

Accessories

Automatic actuation

ECturn, EMD,
TSA 160 NT
Reliable actuation with GEZE sensors

Radar movement detector


Radar movement detectors register all objects that move within the radar field. All movements within the radiation range cause a time-delayed

Automatic swing
door systems
reflection which is forwarded as a door opening signal. The pre-programmed convenience setting of the GEZE radar movement detectors
ensures they can be put into operation quickly. Automatic configuration is possible via keys or a remote control. Reliable detection is achieved
with a clearly defined radar field. Energy can be saved through detection of people’s direction of movement. Excessive door opening is avoided
since cross-traffic can be faded out.

Radar movement detector

GEZE TSA 160 NT IS and Radar movement detector, Andels Hotel, Berlin

Swing Door Systems 57


Automatic swing door systems

Accessories

Manual actuation
ECturn, EMD,
TSA 160 NT

Push buttons
GEZE push buttons for the wireless actuation of system doors – reliable, convenient and safe at the push of a button.
Automatic swing
door systems

Non-contact capacitive push button


The design-oriented and sturdy LED sensor button makes intuitive and straightforward operation possible. No great efforts are required for
actuation – touching the button slightly is sufficient. Suitable for use both indoors and outdoors, the LED sensor button can be recognised
easily in the dark thanks to the blue LED lighting. In addition, the sensor has raised Braille lettering on it. An acoustic and visual signal initiates
actuation through the push button. The push button is waterproof, impact-resistant and vandalism-proof. This makes it very well suited for
outdoor use or installation in the floor.

Non-contact infrared-sensor
Open doors in a flash: With GEZE infrared sensors, internal doors without precise perception requirement can be actuated cleanly and comfor-
tably. Active infrared sensors ensure hygienic access to toilet facilities, for example. The risks of infection are also minimised in hotel kitchens,
hospitals and doctors’ surgeries. The impulse generator is installed at hand height and precisely detects people and objects – independently
of their direction of movement – both in the direct vicinity of only 5 cm as well as 0.6 m away. The different scanning ranges can be optimally
adapted to existing environmental conditions and the wishes of the user groups. The non-contact sensor system provides maximum operating
convenience – people only need to approach them to trigger the automatic opening mechanism. The optimum system structure permits
simple and time-saving installation in the flush-mounted box.

Radio actuation
GEZE radio transmitters are used for wireless actuation of doors and windows as a multi-channel solution. For every additional channel, an
additional electrical device or function can be switched at the push of a button. Thanks to the very small size of the radio modules, radio trans-
mitters can easily be integrated in the drive or in a flush-mounted box. They can also be clipped directly into the elbow switched and mounted
without wires on glass.

Push buttons Non-contact capacitive push button Non-contact infrared sensor

Radio actuation Large-scale button made of plastic Large-scale button made of stainless steel

58 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

Accessories

Electronic protection

ECturn, EMD,
TSA 160 NT
Safety sensor strips
Safety sensor strips are used to monitor and safeguard the pivoting area of automatic swing door leaves. They are installed on both sides of the

Automatic swing
door systems
door, directly on the leaf. This guarantees maximum protection both during opening and closing of the door.

GEZE safety sensors work with infrared light. Electromagnetic waves which are invisible to the human eye are directed by a transmitter to
people or objects within the area of detection. A receiver absorbs the reflected infrared beams and converts them into an electric signal which
is transmitted to the control unit of the door drive. Door movement in the opening direction is stopped as soon as the sensor registers an
obstacle. It is possible for the wall areas to be faded out by the safety sensors (teachable). In closing direction, the sensor actuates the drive of
the closing door and opens it again.

Sensor strip GC 338


The new energy and space-saving sensor strip GC 338 has a very large safety range and offers extended protection on the main and secon-
dary closing edges. In addition, the sensor has background elimination which guarantees the greatest possible safety even where doors open
against walls. Only one single sensor system is required to protect all GEZE swing door drives with door leaf widths of up to 1200 millimetres.
The GC 338 not only offers advantages during installation and commissioning – the complete door system is supplied via one interface. The
sensor automatically adapts to its environment. This saves teaching time and installation costs. The GEZE sensor strip GC 338 has the following
features:

•• Reliable function for all weather and floor conditions up to 3.5 m in accordance with DIN 18650
•• A sensor system protects door leaf widths up to 1200 mm
•• Background elimination: sensor can detect a wall and eliminate it automatically
•• Elegant guide rail, can be realised even with slim door profiles
•• Sleep mode if the sensor is not required - saves up to 50% energy in relation to comparable sensors
•• Current consumption in operating mode: 200 mA
•• Current consumption in sleep mode: 100 mA
•• Fast and simple installation of the modules thanks to the SNAP IN mechanism which allows modules to be positioned and fixed in the profile
without tools being necessary

Sensor strip GC 338

Frontal detection field Background elimination

Swing Door Systems 59


Automatic swing door systems

Accessories

Safety sensor strip with handle bar


1) Position right-hand side of the first transmitter module (S1)
ECturn, EMD,
TSA 160 NT

about 20 mm on the right of the handle bar

E2
S1 S2 E1 2) The second transmitter module (S2) is positioned directly
next to this (distance: 10 to 15 mm)
Automatic swing
door systems

3) The first receiver module (E1) is positioned directly next to


the second transmitter module (S2) (distance: 10 to 15 mm)
≥ 140 mm

4) The door is protected in accordance with DIN 18650

5) Where the handle bar is > 50 mm away from the door, it


≥ 40 mm
can help to enlarge the angle adjustment or to displace S1
to the left or right a little. Note: The door can then not be
protected in accordance with DIN 18650

6) Where the handle bar diameter is > 45 mm, the factory


must be consulted

Note: Diagram shows left-hand (ISO 6), right-hand (ISO 5) is reversed (mirror-image).

Installation on the hinge side

90 Lx

1 1 Ø10
1

„Open“ safety sensor mounted on the hinge „Close“ safety sensor mounted on the oppo- Safety sensor hole pattern, hinge side
side site hinge side

Installation on the opposite hinge side

Lx 90

1 1 Ø10
1

„Close“ safety sensor mounted on the oppo- „Open“ safety sensor mounted on the hinge Safety sensor hole pattern, opposite hinge
site hinge side side side
1 = optional power supply, concealed routing possible. Drillhole Ø 10 for concealed line-feed.
Lx = Profile length 1100 mm : Lx = 489 mm; profile length 1500 mm : Lx = 699 mm

60 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

Accessories

Sensor guid rail GC GR - the ideal combination of safty and design


The GC GR sensor guide rail is availale for the complate range of Slimdrive EMD models and all the TSA 160 NT drive version, and meets the saftx

ECturn, EMD,
TSA 160 NT
requirement for swing door systems specified in DIN18650. The sensor and the guide rail can be put together in such a way that thay look like
a single compact and more integrated design. The features at a glance:

•• Safty tasted to DIN 18650

Automatic swing
•• Suitable for single and double-leaf swing door

door systems
•• Available for all TSA 160 NT and Slimdrive EMD variants with guide rail
•• Sensor and guide rail profile are avalable separately, facilitating retrofittings to existing systems
•• The flexible kit ans a rain cover are avalable as accessor

1 = Sensor guide rail


2 = Sensor strip
1 3 = End cap for sensor guide rail
2 4 = End cap for sensor strip
3

Sensor guide rail GC GR


Adapter for sensor and link arm for slimdrive EMD and TSA 160 NT - Integration of link arm and sensor strips on one level
Exactly similar as in case of the sensor guide rail GC GR, the newly introduced adapter for link arm and sensor enables an optimal installation on
doors with slim frames. The link arm program of the Slimdrive EMD and TSA 160 NT drives was re-worked, so that the adapter can be combined
with new link arms. Advantages:

•• Better integration of link arm and sensor strip GC 334 and GC 338 into the door design
•• Simple installation, in particular in case of slim door frames
•• With the new link arms a maximum soffit depth of 400 mm can now be bridged

Adapter for sensor and link arm for slimdrive EMD and TSA 160 NT
Swing Door Systems 61
Automatic swing door systems

Accessories

EMD and GC GR (GC 334) transom installation with guide on the hinge side
Drawing no. 70106-ep34
ECturn, EMD,
TSA 160 NT
Automatic swing
door systems

EMD

35

71
GC 334
59

GC 334

46 76

EMD and GC GR (GC 334) transom insatallation with guide rail on the opposition hinge side
Drawing no. 70106-ep34

EMD
35

71

GC 334 GC 334

46 76

62 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

Accessories

TSA 160 NT and GC GR (GC 334) transom insatallation with guide rail on the hinge side
Drawing no. 70106-ep34

ECturn, EMD,
TSA 160 NT
Automatic swing
door systems
TSA 160 NT

40
21

76
GC 334
69

GC 334

76
46

GC GR (GC 334) 1100 mm, single leaf


Drawing no. 70106-ep34
Note: For double-leaf doors mirror and add this view.

A B
L/2 L/2
L/2 L/2 30 60 30
30 60 30 9 9
9 9
0
0

Ø1
Ø1

Ø6
Ø6
0
Ø1

Ø6
Ø1
Ø6
0

FB FB

A = Hinge side
B = Opposition hinge side
FB = Leaf width
L = Length

Swing Door Systems 63


Automatic swing door systems

Accessories

Service Tools
ECturn, EMD,
TSA 160 NT

GEZEconnects
Bluetooth is an internationally standardised short-distance radio signal with a range of up to ten metres. The software GEZEconnects makes
Automatic swing
door systems

wireless connection via Bluetooth possible between a computer and the automatic door systems from GEZE. All door system settings can be
carried out via an intuitive graphic interface, stored, sent by e-mail and transferred to a word processing programme as a protocol. Diagnosis
functions show the most important function parameters of the door system in real time, so that problems are recognised at a glance and can
be eliminated. All the pre-settings can be taken over very easily for further door systems. The convenient documentation of initial operation,
servicing and diagnosis protocols as well as all statistical data can be downloaded at any time. Password protection to freeze operating para-
meters and servicing data guarantees there will be no unauthorised modifications made.

Service terminal ST 220


Mobile, handy and straightforward – that is the parameter setting for the automatic GEZE door systems using the service terminal ST 220.
Communication and data exchange between the service terminal and the door drive is via an integrated RS485 interface. The large illuminated
display is easy to operate thanks to the plain text display. The service terminal is equipped with a readout function for servicing and diagnosis
work. Power is supplied via the door system. Password protection to freeze operating parameters and servicing data guarantees there will be
no unauthorised modifications made.

Note
GEZE service tools are available for the Slimdrive EMD and TSA 160 NT range of drives.

GEZEconnects I SOFTW ARE


zur kabellosenVerbindung von GEZE AutomatischenTürsystemen und PCs über Bluetooth

TÜRTECHNIK GEZE GmbH Systemvoraussetzungen:


Reinhold-Vöster-Str. 21-29
PC mit Windows XP
71229 Leonberg
Intel oder 100% kompatiblen
Germany
Prozessor
Telefon: +49 (0)7152-203-0 500 MB RAM
Telefax: +49 (0)7152-203-310 1,5 GHz
I SOFTW ARE

AUTOMATISCHE
CD Laufwerk
TÜRSYSTEME www.geze.com
Bluetooth Schnittstelle
150 MB freier Speicherplatz

RWA UND
GEZEconnects I SOFTW ARE
GEZEconnects

LÜFTUNGSTECHNIK

zur kabellosenVerbindung von GEZE AutomatischenTürsystemen und PCs über Bluetooth

SICHERHEITSTECHNIK

GLASSYSTEME Id.Nr. 134995 · Version 090518 · Änderungen vorbehalten

B EW E G U N G M I T S Y S T E M

B EW E G U N G M I T S Y S T E M

GEZEconnects Service terminal ST 220

64 GEZE AUTOMATIC DOOR SYSTEMS


Automatic swing door systems

ECturn, EMD and TSA 160 NT

References

ECturn, EMD,
TSA 160 NT
Automatic swing
door systems
GEZE TSA 160 NT, BMW World, Munich, Germany

GEZE Slimdrive EMD F-IS, Olympic Hall, Coubertin, Munich, Germany

Swing Door Systems 65


Innovative system solutions

POTENTIAL APPLICATIONS OF GEZE PRODUCTS

You will find more product information in the relevant brochures, see ID numbers.
ECturn, EMD,
TSA 160 NT

Door technology

Overhead door closers


01
ID 091593, ID 091594
Automatic swing
door systems

Hold-open systems
02
ID 091593, ID 091594

Integrated door closers


03
ID 091609

Floor springs
04
ID 091607

Sliding door gear systems and linear guides


05
ID 123605, ID 008770, ID 000586

Automatic door systems 13


23
Swing doors
06
ID 144785

Sliding, telescopic and folding doors 11


07
ID 143639 01

Circular and semi-circular sliding doors 02


08
ID 135772 22

Revolving doors
09 06 17
ID 132050
06
Actuation devices and sensors
10
ID 142655 11

Smoke and heat extraction and window technology

Fanlight opening systems 04


11
ID 127787

Electric opening and locking systems


12
ID 127785, ID 127789

Electrical spindle and linear drives


13
ID 127785, ID 127789
08
Electric chain drives
14
ID 127785, ID 127789

Smoke and heat extraction systems


15 20 07
ID 127785, ID 139075 14
10

Safety technology
07

Emergency exit systems


16
ID 132408

Access control systems


17
ID 132158

Panic locks
18
ID 132848

Electric strikes
19
ID 148666

Building management system


20
ID 132408

Glass systems

Manual sliding wall systems (MSW)


21
ID 104377

Integrated all-glass systems (IGG)


22
ID 104366

GEZE Patch fittings mono glass systems


23
ID 122521

66 GEZE AUTOMATIC DOOR SYSTEMS


Innovative system solutions

POTENTIAL APPLICATIONS OF GEZE PRODUCTS

ECturn, EMD,
TSA 160 NT
Door technology

The functionality, superior performance and reliability of


GEZE door closers are impressive. A common design across

Automatic swing
door systems
the range, the ability to use them on all common door leaf
widths and weights, and the fact that they can be individu-
ally adjusted makes their selection simple. They are con-
tinually being improved and enhanced with up-to-date fea-
tures. For example, the requirements of fire protection and
accessibility are fulfilled with a door closer system.

Automatic door systems

GEZE automatic door systems open up a huge variety of


options in door design. The latest, innovative high-per-
formance drive technology, safety, ease of accessibility
15 17 and first class universal drive design set them apart. GEZE
offers complete solutions for individual requirements. A
dedicated division is responsible for the development and
construction of individual special designs.

Smoke and heat extraction and window technology


21

15 GEZE smoke and heat extraction systems and ventilation


technology provide complete systems solutions combin-
12
05 ing the many requirements of different types of windows.
03 We supply a full range from energy efficient drive systems
to natural ventilation and complete solutions for supplying
and extracting air, also as certified SHEVs.

Safety technology

GEZE safety technology sets the standards where preven-


tative fire protection, access control and anti-theft security
in emergency exits are concerned. For each of these objec-
tives GEZE offers tailored solutions, which combine the in-
21 dividual safety requirements in one intelligent system and
close doors and windows in case of danger in a coordinated
manner.
18

Building systems
16
09
19
In GEZE’s Building Management System GEZE door, win-
dow and safety products can be integrated in to the se-
curity and control systems of the building. A central con-
trol and visualisation system monitors various automation
components in the building and offers security through
many different networking capabilities.

Glass systems

GEZE glass systems stand for open and transparent interior


design. They can either blend discreetly into the architec-
ture of the building or stand out as an accentuated feature.
GEZE offers a wide variety of technologies for functional,
reliable and aesthetic sliding wall or sliding door systems
providing security with lots of design scope.

Swing Door Systems 67


G E Z E automatic door systems

GEZE GmbH GEZE Service GmbH Bulgaria India Scandinavia – Denmark


P.O. Box 1363 Niederlassung Süd-West GEZE Bulgaria - Trade GEZE India Private Ltd. GEZE Danmark
71226 Leonberg Reinhold-Vöster-Straße 25 Representative Office MF 2 & 3, Guindy Industrial Estate Branch office of GEZE Scandinavia AB
Germany 71229 Leonberg 61 Pirinski Prohod, entrance „B“, Ekkattuthangal Mårkærvej 13 J-K
Tel. +49 (0) 1802-923392 4th floor, office 5, Chennai 600 097 2630 Taastrup
GEZE GmbH Fax +49 (0) 7152-92 33 63 1680 Sofia Tamilnadu Tel. +45 (0) 46-32 33 24
Reinhold-Vöster-Straße 21-29 [email protected] Tel. +359 (0) 24 70 43 73 Tel. +91 (0) 44 30 61 69 00 Fax +45 (0) 46-32 33 26
71229 Leonberg Fax +359 (0) 24 70 62 62 Fax +91 (0) 44 30 61 69 01 [email protected]
Germany GEZE Service GmbH [email protected] [email protected]
Telefon +49 (0) 7152-203-0 Niederlassung Süd Singapore
Telefax +49 (0) 7152-203-310 Parkring 17 China Italy GEZE (Asia Pacific) Pte. Ltd.
www.geze.com 85748 Garching bei München GEZE Industries (Tianjin) Co., Ltd. GEZE Italia S.r.l 21 Bukit Batok Crescent
Tel. +49 (0) 1802-923392 Shuangchenzhong Road Via Giotto, 4 #23-75 Wcega Tower
Germany Fax +49 (0) 89-120 07 42-60 Beichen Economic Development 20040 Cambiago (MI) Singapore 658065
GEZE Sonderkonstruktionen GmbH [email protected] Area (BEDA) Tel. +39 (0) 29 50 695-11 Tel: +65 6846 1338
Planken 1 Tianjin 300400, P.R. China Fax +39 (0) 29 50 695-33 Fax: +65 6846 9353
97944 Boxberg-Schweigern GEZE Service GmbH Tel. +86 (0) 22-26 97 39 95-0 [email protected] [email protected]
Tel. +49 (0) 7930-92 94-0 Niederlassung Mitte Fax +86 (0) 22-26 97 27 02
Fax +49 (0) 7930-92 94-10 Feldbergstraße 59 [email protected] GEZE Engineering Roma S.r.l. South Africa
[email protected] 61440 Oberursel (b. Frankfurt) Via Lucrezia Romana, 91 GEZE Distributors (Pty) Ltd.
Tel. +49 (0) 1802-923392 GEZE Industries (Tianjin) Co., Ltd. 00178 Roma 118 Richards Drive, Halfway House,
GEZE GmbH Fax +49 (0) 6171-63 327-19 Branch Office Shanghai Tel. +39 (0) 6-72 65 311 Ext 111, P.O. Box 7934, Midrand 1685,
Niederlassung Süd-West [email protected] Unit 25N, Cross Region Plaza Fax +39 (0) 6-72 65 3136 South Africa
Breitwiesenstraße 8 No 899, Ling Ling Road, [email protected] Tel: + 27 (0) 113 158 286
71229 Leonberg GEZE Service GmbH XuHui District Fax: + 27 (0) 113158261
Tel. +49 (0) 7152-203-594 Niederlassung West 200030 Shanghai, P.R China Poland [email protected]
Fax +49 (0) 7152-203-438 Nordsternstraße 65 Tel. +86 (0) 21-523 40 960 GEZE Polska Sp.z o.o.
[email protected] 45329 Essen Fax +86 (0) 21-644 72 007 ul. Annopol 21 Switzerland
Tel. +49 (0) 1802-923392 [email protected] 03-236 Warszawa GEZE Schweiz AG
GEZE GmbH Fax +49 (0) 201-8 30 82-25 Tel. +48 (0) 22 440 4 440 Bodenackerstrasse 79
Niederlassung Süd-Ost [email protected] GEZE Industries (Tianjin) Co., Ltd. Fax +48 (0) 22 440 4 400 4657 Dulliken
Parkring 17 Branch Office Guangzhou [email protected] Tel. +41 (0) 62 285 54 00
85748 Garching bei München GEZE Service GmbH Room 17C3 Fax +41 (0) 62 285 54 01
Tel.: +49 (0) 89-120 07 42-50 Niederlassung Nord-Ost Everbright Bank Building, No.689 Romania [email protected]
Fax.: +49 (0) 7152-203-77050 Bühringstraße 8 Tian He Bei Road GEZE Romania S.R.L.
[email protected] 13086 Berlin (Weissensee) 510630 Guangzhou IRIDE Business Park, Turkey
Tel. +49 (0) 1802-923392 P.R. China Str. Dimitrie Pompeiu nr. 9-9a, GEZE Kapı ve Pencere Sistemleri
GEZE GmbH Fax +49 (0) 30-47021733 Tel. +86 (0) 20-38 73 18 42 Building 10, Level 2, Sector 2, San. ve Tic. Ltd. Şti.
Niederlassung Ost [email protected] Fax +86 (0) 20-38 73 18 34 020335 Bucharest Ataşehir Bulvarı, Ata 2/3
Bühringstraße 8 [email protected] Tel.: +40 (0) 21 25 07 750 Plaza Kat: 9 D: 84 Ataşehir
13086 Berlin (Weissensee) GEZE Service GmbH Fax: +40 (0) 21 25 07 750 Ataşehir / İstanbul
Tel. +49 (0) 30-47 89 90-0 Niederlassung Nord GEZE Industries (Tianjin) Co., Ltd [email protected] Tel. + 90 (0) 216 455 43 15
Fax +49 (0) 30-47 89 90-17 Theodorstr. 42-90, Haus 11 Branch Office Beijing Fax + 90 (0) 216 455 82 15
[email protected] 22761 Hamburg Room 1001, Tower D Russian [email protected]
Tel. +49 (0) 1802-923392 Sanlitun SOHO OOO GEZE RUS
GEZE GmbH Fax +49 (0) 40-219 07 16-19 No. 8, Gongti North Road, Gamsonovskiy Per. 2 Ukraine
Niederlassung Mitte/Luxemburg [email protected] Chaoyang District 115191 Moskau GEZE Ukraine TOV
Adenauerallee 2 100027 Beijing, P.R.China Tel. +7 (0) 495 933 06 59 ul. Viskoznaya, 17,
61440 Oberursel (b. Frankfurt) Austria Tel. +86 (0) 10-59 35 93 00 Fax +7 (0) 495 933 06 74 Building 93-B, Office 12
Tel. +49 (0) 6171-63 610-0 GEZE Austria Fax +86 (0)10-59 35 93 22 [email protected] 02660 Kiev
Fax +49 (0) 6171-63 610-1 Wiener Bundesstrasse 85 [email protected] Tel./Fax +38 (0) 44 501 22 25
[email protected] A-5300 Hallwang Scandinavia – Sweden [email protected]
Tel: +43/6225/87180 France GEZE Scandinavia AB
GEZE GmbH Fax: +43/6225/87180-299 GEZE France S.A.R.L. Mallslingan 10 United Arab Emirates/GCC
Niederlassung West [email protected] ZAC de l’Orme Rond Box 7060 GEZE Middle East
Nordsternstraße 65 RN 19 18711 Täby, Sweden P.O. Box 17903
45329 Essen Baltic States 77170 Servon Tel. +46 (0) 8-7323-400 Jebel Ali Free Zone
Tel. +49 (0) 201-83 082-0 GEZE GmbH Baltic States office Tel. +33 (0) 1 60 62 60 70 Fax +46 (0) 8-7323-499 Dubai
Fax +49 (0) 201-83 082-20 Dzelzavas iela 120 S Fax +33 (0) 1 60 62 60 71 [email protected] Tel. +971 (0) 4-88 33 112
[email protected] 1021 Riga [email protected] Fax +971 (0) 4-88 33 240
Tel. +371 (0) 67 89 60 35 Scandinavia – Norway [email protected]
GEZE GmbH Fax +371 (0) 67 89 60 36 Hungary GEZE Scandinavia AB avd. Norge
Niederlassung Nord [email protected] GEZE Hungary Kft. Industriveien 34 B United Kingdom
Haus 11, 1. OG - Theodorstr. 42a Bartók Béla út 105-113. 2073 Dal GEZE UK Ltd.
22761 Hamburg-Bahrenfeld Benelux Budapest Tel. +47 (0) 639-57 200 Blenheim Way
Tel. +49 (0) 40-2 19 07 16-13 GEZE Benelux B.V. H-1115 Fax +47 (0) 639-57 173 Fradley Park
Fax +49 (0) 40-2 19 07 16-19 Steenoven 36 Tel. +36 (1) 481 4670 [email protected] Lichfield
[email protected] 5626 DK Eindhoven Fax +36 (1) 481 4671 Staffordshire WS13 8SY
Tel. +31 (0) 40-26 290-80 [email protected] Scandinavia – Finland Tel. +44 (0) 1543 44 30 00
Fax +31 (0) 40-26 290-85 Branch office of GEZE Scandinavia AB Fax +44 (0) 1543 44 30 01
[email protected] Iberia Herralantie 824 [email protected]
GEZE Iberia S.R.L. Postbox 20
Pol. Ind. El Pla 15871 Hollola
G E Z E R epresentative C/Comerc, 2-22, Nave 12 Tel. +358 (0) 10-40 05 100
08980 Sant Feliu de Llobregat Fax +358 (0) 10-40 05 120
(Barcelona) [email protected]
Tel. +34 9-02 19 40 36
Fax +34 9-02 19 40 35
[email protected]

Id.No. 144785 · Vers. EN 120827 · Subject to modification