Spec Sheet

Cisco UCS B200 M6


Blade Server
A printed version of this document is only a copy
and not necessarily the latest version. Refer to
the following link for the latest released version:
https://www.cisco.com/c/en/us/products/servers-unified-
computing/ucs-b-series-blade-servers/datasheet-
listing.html

CISCO SYSTEMS PUBLICATION HISTORY


170 WEST TASMAN DR.
SAN JOSE, CA, 95134 REV A.43 DECEMBER 03, 2024 
WWW.CISCO.COM
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blade Server Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 5
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
STEP 1 CHOOSE BASE SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
STEP 2 CHOOSE CPU(S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
STEP 3 CHOOSE MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Memory Configurations, Features, and Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 4 CHOOSE MLOM REAR MEZZANINE ADAPTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
STEP 5 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC or Port Expander) . . . . . . . . 23
STEP 6 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER . . . . . . . . . . . . . . . . . . . . . . . . 24
STEP 7 CHOOSE OPTIONAL DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STEP 8 CHOOSE TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
STEP 9 CHOOSE UCSM SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . 31
STEP 11 CHOOSE OPTIONAL RECOVERY MEDIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
STEP 12 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Unified Computing Warranty, No Contract . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Smart Net Total Care (SNTC) for Cisco UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service . . . . . . . . . . . . . . . . . 38
Solution Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Smart Net Total Care for UCS Hardware Only Service . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Partner Support Service for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
PSS for UCS Hardware Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Unified Computing Combined Support Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
UCS Drive Retention Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Local Language Technical Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
System Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Memory Configuration and Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Memory Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Memory Support for 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake) . . . . . . . . 49
PMem Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
App Direct Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Memory Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
UPGRADING or REPLACING CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
UPGRADING or REPLACING MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

1 Cisco UCS B200 M6 Blade Server


OVERVIEW

OVERVIEW
Delivering performance, versatility and density without compromise, the Cisco UCS B200 M6 Blade Server
addresses the broadest set of workloads, from IT and web infrastructure through distributed database.

The enterprise-class Cisco UCS B200 M6 blade server extends the capabilities of Cisco’s Unified Computing
System portfolio in a half-width blade form factor. The Cisco UCS B200 M6 harnesses the power of the latest
3rd Gen Intel® Xeon® Scalable Processors (Ice Lake) with:

■ Up to 2 TB of RAM per CPU (using 16 x 128 GB DRAMs) or up to 5 TB per CPU (using 8 x 128 GB DRAMs
and 8 x 512 GB Intel® Optane™ Persistent Memory Modules (PMem))
■ Two solid-state drives (SSDs), or
■ Two PCIE NVMe drives, or
■ Mini storage carrier with M.2 SATA drives. UCS-M2-HWRAID is required when selecting the M.2 SATA
drives.
■ Up to 80 Gbps throughput connectivity.

The B200 M6 server is the follow-on server to the popular B200 M5 server and includes support for the
following:

■ 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake).


■ Up to 128 GB 3200-MHz DDR4 memory DIMMs.
■ Up to 4 TB total memory (for 2 CPUs) is available if the memory slots are all populated with 32 x 128
GB DDR4 DIMMs or 10 GB total memory if the memory slots are populated with 16 x 128 GB DDR4 DIMMs
and 16 x 512 GB PMem.
■ Front mezzanine daughter card options
■ 12G RAID controller module with two 2.5-inch SAS/SATA SSD drives, or
■ Pass-through module with two 2.5-inch PCIe NVMe drives, or
■ Mini storage carrier with up to four M.2 SATA drives. UCS-M2-HWRAID is required when
selecting the M.2 SATA drives.
NOTE: All options listed in the Spec Sheet are compatible with Intersight Managed Mode and UCSM Managed
Mode configurations. To see the most recent list of components that are supported in Intersight Managed
Mode, see Supported Systems.

Figure 1 Cisco UCS B200 M6 Blade Server

Cisco UCS B200 M6 Blade Server 3


DETAILED VIEWS

DETAILED VIEWS
Blade Server Front View
Figure 2 is a detailed front view of the Cisco UCS B200 M6 Blade Server.

Figure 2 Blade Server Front View

1 2 3 4 5 6 7 8 9 10

1 Asset pull tag  6 Drive Bay 2(shown unpopulated)


Each server has a plastic tag that pulls
out of the front panel. The tag contains
the server serial number as well as the
product ID (PID) and version ID (VID). The
tag also allows you to add your own asset
tracking label without interfering with
the intended air flow.

2 Console connector1 7 Power button and LED

3 Ejector thumbscrew 8 Network link status LED

4 Blade ejector handle 9 Blade health LED

5 Drive bay 1 (shown populated) 10 Locate button and LED

Notes:
1. A KVM I/O cable plugs into the console connector, and can be ordered as a spare. The KVM I/O
cable in included with every Cisco UCS 5100 Series blade server chassis accessory kit.

4 Cisco UCS B200 M6 Blade Server


BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES


Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a listed feature or capability (for example, number of processors, disk drives, or amount of memory) are
provided in CONFIGURING the SERVER on page 7

Table 1 Capabilities and Features

Capability/Feature Description

Chassis The UCS B200 M6 Blade Server mounts in a Cisco UCS 5108 Series blade
server chassis or UCS Mini blade server chassis.

CPU One or two 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake). Also note
that the B200 M6 Blade Server BIOS inherently enables support for Intel
Advanced Encryption Standard New Instructions (AES-NI) and does not have
an option to disable this feature.

Chipset Intel® C621A series chipset (Lewisburg)

Memory ■ 32 total DIMM slots


■ Support for Advanced ECC
■ Support for registered ECC DIMMs (RDIMMs)
■ Support for load-reduced DIMMs (LR DIMMs)
■ Support for PMem
■ Up to 4 TB GB DDR4 DIMM memory capacity (32 x 128 GB DIMMs)
■ Up to 10 TB memory with a mix of DIMMs and PMem
• 16 x 128 GB DIMMs, and
• 16 x 512 GB PMem

Modular LOM One modular LOM (mLOM) connector at the rear of the blade for a Cisco
mLOM VIC adapter, which provides Ethernet or Fibre Channel over Ethernet
(FCoE) connectivity

Cisco UCS B200 M6 Blade Server 5


BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature Description

Mezzanine Adapters One rear mezzanine connector for


(Rear) ■ Cisco Mezzanine VIC Adapter, or
■ Cisco Mezzanine Port Expander

Mezzanine Adapters One front mezzanine connector for


(Front)
■ Cisco FlexStorage 12G RAID controller with two SAS/SATA SSD drives, or
■ Cisco FlexStorage NVMe pass-through module with two drives, or
■ Mini storage carrier with up to four M.2 SATA drives. UCS-M2-HWRAID is
required when selecting the M.2 SATA drives.

Storage controller For the front mezzanine connector:


■ Cisco FlexStorage 12G RAID controller module with drive bays
■ Cisco FlexStorage NVMe pass-through module with drive bays

Storage devices Two front facing drive bays with choice of:
■ Up to two 2.5” SFF solid-state drives up to 7.6 TB capacity each
■ Up to two 2.5” PCIe NVMe drives up to 6.4 TB capacity each
■ Up to two HW-RAID modules, each with either one or two 240 GB or 960
GB M.2 SATA drives. UCS-M2-HWRAID is required when selecting the M.2
SATA drives.

Video The Cisco Integrated Management Controller (CIMC) provides video using a
Matrox G200e video/graphics controller.
■ Integrated 2D graphics core with hardware acceleration
■ DDR4 memory interface supports up to 512 MB of addressable memory
(8 MB is allocated by default to video memory)
■ Supports display resolutions up to 1920 x 1200 32 bpp@ 60Hz
■ Single lane PCI-Express host interface running at Gen 2 speed

Interfaces One KVM console connector on the front panel

Power subsystem Integrated in the Cisco UCS 5108 blade server chassis

Fans Integrated in the Cisco UCS 5108 blade server chassis.

Integrated management The built-in Cisco Integrated Management Controller enables monitoring of
processor server inventory, health, and system event logs

ACPI Advanced Configuration and Power Interface (ACPI) 6.2 standard Supported.

UCSM UCS Manager (UCSM) 4.2(1) or later runs in the Fabric Interconnect and
automatically discovers and provisions some of the server components.

CIMC Cisco Integrated Management Controller 4.2(1) or later

6 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

CONFIGURING the SERVER


Follow these steps to configure the Cisco UCS B200 M6 Blade Server:

■ STEP 1 CHOOSE BASE SERVER SKU, page 8


■ STEP 2 CHOOSE CPU(S), page 9
■ STEP 3 CHOOSE MEMORY, page 13
■ STEP 4 CHOOSE MLOM REAR MEZZANINE ADAPTER, page 20
■ STEP 5 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC or Port Expander), page 22
■ STEP 6 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER, page 24
■ STEP 7 CHOOSE OPTIONAL DRIVES, page 25
■ STEP 8 CHOOSE TRUSTED PLATFORM MODULE, page 30
■ STEP 9 CHOOSE UCSM SOFTWARE, page 31
■ STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 32
■ STEP 11 CHOOSE OPTIONAL RECOVERY MEDIA, page 35

Cisco UCS B200 M6 Blade Server 7


CONFIGURING the SERVER

STEP 1 CHOOSE BASE SERVER SKU


Verify the product ID (PID) of the server as shown in Table 2.

Table 2 PID of the Base UCS B200 M6 Blade Server

Product ID (PID) Description

UCS-M6-MLB UCS M6 Rack, Blade MLB


This major line bundle (MLB) consists of the Blade Server (UCSB-B200-M6) with
software PIDs. Use this PID to begin a new configuration.

UCSB-B200-M61 UCS B200 M6 Blade Server without CPU, memory, drive bays, drives, VIC adapter,
or mezzanine adapters (ordered as a blade chassis option)

UCSB-B200-M6-U1 UCS B200 M6 Blade Server without CPU, memory, drive bays, drives, VIC adapter,
or mezzanine adapters (ordered standalone)

Notes:
1. This product may not be purchased outside of the approved bundles (must be ordered under the
MLB)

A base Cisco UCS B200 M6 blade server ordered in Table 2 does not include any components or
options. They must be selected during product ordering.

Please follow the steps on the following pages to order components such as the following, which
are required in a functional blade:

• CPUs
• Memory
• Cisco FlexStorage RAID controller with drive bays for SAS or SATA SSDs (or blank, for no local
drive support)
• Cisco FlexStorage pass-through module with drive bays for PCIe NVMe drives)
• SSD, PCIe, or SATA M.2 drives (UCS-M2-HWRAID is required when selecting the M.2 SATA
drives)
• Cisco adapters (such as the VIC 1440, VIC 1480, Port Expander)

8 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

STEP 2 CHOOSE CPU(S)


The standard CPU features are:

■ 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake)


■ Intel® C621A series chipset
■ Cache size of up to 60 MB
■ Up to 40 cores

Select CPUs

The available CPUs are listed in Table 3. See Table 4 on page 11 for CPU suffix notations.

Table 3 Available CPUs

Highest DDR4
Clock
Cache UPI1 Links DIMM Clock PMem
Product ID (PID) Freq Power (W) Cores
Size (MB) (GT/s) Support (MHz)2 Support
(GHz)

8000 Series Processors


UCS-CPU-I8380 2.3 270 60 40 3 at 11.2 3200 Yes
UCS-CPU-I8368 2.4 270 57 38 3 at 11.2 3200 Yes
UCS-CPU-I8362 2.8 265 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8360Y 2.4 250 54 36 3 at 11.2 3200 Yes
UCS-CPU-I8358P 2.6 240 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8358 2.6 250 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8352M 2.3 185 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8352Y 2.2 205 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8352V 2.1 195 54 36 3 at 11.2 2933 Yes
UCS-CPU-I8352S 2.2 205 48 32 3 at 11.2 3200 Yes
UCS-CPU-I8351N3 2.4 225 54 36 0 2933 Yes
6000 Series Processors
UCS-CPU-I6354 3.0 205 39 18 3 at 11.2 3200 Yes
UCS-CPU-I6348 2.6 235 42 28 3 at 11.2 3200 Yes
UCS-CPU-I6346 3.1 205 36 16 3 at 11.2 3200 Yes
UCS-CPU-I6342 2.8 230 36 24 3 at 11.2 3200 Yes
UCS-CPU-I6338N 2.2 185 48 32 3 at 11.2 2666 Yes
UCS-CPU-I6338T 2.1 165 36 24 3 at 11.2 3200 Yes
UCS-CPU-I6338 2.0 205 48 32 3 at 11.2 3200 Yes
UCS-CPU-I6336Y 2.4 185 36 24 3 at 11.2 3200 Yes
UCS-CPU-I6334 3.6 165 18 8 3 at 11.2 3200 Yes
UCS-CPU-I6330N 2.2 165 42 28 3 at 11.2 2666 Yes
UCS-CPU-I6330 2.0 205 42 28 3 at 11.2 2933 Yes

Cisco UCS B200 M6 Blade Server 9


CONFIGURING the SERVER

Table 3 Available CPUs

Highest DDR4
Clock
Cache UPI1 Links DIMM Clock PMem
Product ID (PID) Freq Power (W) Cores
Size (MB) (GT/s) Support (MHz)2 Support
(GHz)

UCS-CPU-I6326 2.9 185 24 16 3 at 11.2 3200 Yes


UCS-CPU-I6314U4 2.3 205 48 32 0 3200 Yes
UCS-CPU-I6312U5 2.4 185 36 24 0 3200 Yes
5000 Series Processors
UCS-CPU-I5320T 2.3 150 30 20 3 at 11.2 2933 Yes
UCS-CPU-I5320 2.2 185 39 26 3 at 11.2 2933 Yes
UCS-CPU-I5318N 2.1 150 36 24 3 at 11.2 2666 Yes
UCS-CPU-I5318S 2.1 165 36 24 3 at 11.2 2933 Yes
UCS-CPU-I5318Y 2.1 165 36 24 3 at 11.2 2933 Yes
UCS-CPU-I5317 3.0 150 18 12 3 at 11.2 2933 Yes
UCS-CPU-I5315Y 3.2 140 12 8 3 at 11.2 2933 Yes
4000 Series Processors
UCS-CPU-I4316 2.3 150 30 20 2 at 10.4 2666 No
UCS-CPU-I4314 2.4 135 24 16 2 at 10.4 2666 Yes
UCS-CPU-I4310T 2.3 105 15 10 2 at 10.4 2666 No
UCS-CPU-I4310 2.1 120 18 12 2 at 10.4 2666 No
UCS-CPU-I4309Y 2.8 105 12 8 2 at 10.4 2666 No

Notes:
1. UPI = Ultra Path Interconnect.
2. If higher or lower speed DIMMs are selected than what is shown in Table 6 on page 14 for a given CPU speed,
the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.
3. The maximum number of UCS-CPU-I8351N CPUs is one
4. The maximum number of UCS-CPU-I6314U CPUs is one
5. The maximum number of UCS-CPU-I6312U CPUs is one

10 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Table 4 CPU Suffixes

CPU Suffix Description Features

N Networking Optimized for use in networking applications like L3


Optimized forwarding, 5G UPF, OVS DPDK, VPP FIB router, VPP IPsec,
web server/NGINX, vEPC, vBNG, and vCMTS. SKUs have
higher base frequency with lower TDPs to enable best
performance/Watt
P Cloud Optimized SKU specifically designed for cloud IaaS environments to
deliver higher frequencies at constrained TDPs
V Cloud Optimized SKUs specifically designed for cloud environments to
deliver high rack density and maximize VM/cores per
TCO$
T High T case SKUs designed for Network Environment-Building System
(NEBS) environments
U 1-socket Optimized Optimized for targeted platforms adequately served by
the cores, memory bandwidth and IO capacity available
from a single processor
S Max SGX enclave Supports Max SGX enclave size (512GB) to enhance and
size protect the most sensitive portions of a workload or
service
M Media and AI Media, AI and HPC Segment Optimized for lower TDP &
optimized higher frequencies delivering better perf/w
Y Speed Select – Intel® Speed Select Technology provides the ability to set
Performance Profile a guaranteed base frequency for a specific number of
cores, and assign this performance profile to a specific
application/workload to guarantee performance
requirements. It also provides the ability to configure
settings during runtime and provide additional frequency
profile configuration opportunities.

Supported Configurations

(1) DIMM only configurations:

■ Select one or two identical CPUs listed in Table 3 on page 9

(2) DIMM/PMem Mixed Configurations:

■ You must select two identical CPUs listed in Table 3 on page 9

(3) Configurations with NVMe PCIe drives:

■ You must select two identical CPUs listed in Table 3 on page 9


(4) One-CPU Configuration

— Choose one CPU from any one of the rows of Table 3 Available CPUs, page 9

Cisco UCS B200 M6 Blade Server 11


CONFIGURING the SERVER

(5) Two-CPU Configuration

— Choose two identical CPUs from any one of the rows of Table 3 Available CPUs, page 9

NOTE:
■ You cannot have two I8351N or two I6314U or I6312U CPUs in a two-CPU
configuration.
■ If you configure a server with one I8351N CPU or one I6314U CPU or one
I6312U CPU you cannot later upgrade to a 2-CPU system with two of these
CPUs.

Caveats

■ The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:
— STEP 3 CHOOSE MEMORY, page 13
— STEP 7 CHOOSE OPTIONAL DRIVES, page 25

CAUTION: In Table 5, systems configured with the processors shown must


adhere to the ambient inlet temperature thresholds specified. If not, a
fan fault or executing workloads with extensive use of heavy instructions
sets such as Intel® Advanced Vector Extensions 512 (Intel® AVX-512) may
assert thermal and/or performance faults with an associated event
recorded in the System Event Log (SEL). Table 5 describes the
configuration restrictions to ensure proper cooling and avoid excessive
processor throttling, which may impact system performance.

Table 5 Ambient Temperature and Configuration Restrictions

Processor Thermal Blade Ambient


CPU Product ID (PID) Configuration Restrictions
Design Power (TDP) Slot Temperature Limit

Any Any Any 27 oC (80.6 oF) None

Any UCS-CPU-I6314U Any 27 oC (80.6 oF) Limited to single processor


UCS-CPU-I8351N configurations

12 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

STEP 3 CHOOSE MEMORY


The available memory for the B200 M6 is as follows:

■ Clock speed: 3200 MHz


■ Ranks per DIMM: 1, 2, 4, or 8
■ Operational voltage: 1.2 V
■ Registered ECC DDR4 DIMMS (RDIMMs), Load-reduced DIMMs (LRDIMMs), or Intel® OptaneTM
Persistent Memory Modules (PMem).

Memory is organized with eight memory channels per CPU, with up to two DIMMs per channel, as
shown in Figure 3

Figure 3 B200 M6 Memory Organization


Slot 1

Slot 2

Slot 2

Slot 1
A1 A2 A2 A1

Chan A Chan A

B1 B2 B2 B1

Chan B
Chan B

C1 C2 C2 C1
Chan C Chan C

D1 D2 D2 D1
Chan D Chan D

CPU 1 CPU 2
E1 E2 E2 E1

Chan E Chan E

F1 F2 F2 F1

Chan F Chan F

G1 G2 G2 G1

Chan G Chan G

H1 H2 H2 H1

Chan H Chan H

8 memory channels per CPU,


up to 2 DIMMs per channel
32 DIMMS total (16 per CPU)
4 TB maximum memory (with 128GB DIMMs)

Cisco UCS B200 M6 Blade Server 13


CONFIGURING the SERVER

Choose DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option.
The supported memory DIMMs, PMem, PMem Memory Modes, and the mirroring option are listed
in Table 6.

Table 6 Available DDR4 DIMMs and PMem

Ranks
Product ID (PID) PID Description Voltage
/DIMM

DIMMs
UCS-MR-X16G1RW 16 GB RDIMM SRx4 3200 (8Gb) 1.2 V 1
UCS-MR-X32G1RW 32 GB RDIMM SRx4 3200 (16Gb) 1.2 V 1
UCS-MR-X32G2RW 32 GB RDIMM DRx4 3200 (8Gb) 1.2 V 2
UCS-MR-X64G2RW 64 GB RDIMM DRx4 3200 (16Gb) 1.2 V 2
UCS-ML-128G4RW 128 GB LRDIMM QRx4 3200 (16Gb) (non-3DS) 1.2 V 4
Intel® OptaneTM Persistent Memory Product (PMem)1
UCS-MP-128GS-B0 Intel® OptaneTM Persistent Memory, 128GB, 3200 MHz
UCS-MP-256GS-B0 Intel® OptaneTM Persistent Memory, 256GB, 3200 MHz
UCS-MP-512GS-B0 Intel® OptaneTM Persistent Memory, 512GB, 3200 MHz
DIMM Blank2
UCS-DIMM-BLK UCS DIMM Blank
Intel® Optane™ Persistent Memory (PMem) Operational Modes
UCS-DCPMM-AD App Direct Mode
UCS-DCPMM-MM Memory Mode
Memory Mirroring Option3
N01-MMIRROR Memory mirroring option

Notes:
1. All 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake) support PMem products, except 4309Y, 4310,
4310T, and 4316 processor.
2. Any empty DIM M slot must be populated with a DIMM blank to maintain proper cooling airflow.
3. For Memory Configuration and Mirroring, please refer to Memory Configuration and Mirroring on page
46 and Memory Support for 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake) on
page 49.

14 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Memory Configurations, Features, and Modes


System speed is dependent on the CPU DIMM speed support. Refer to Available CPUs on page 9
for DIMM speeds.

■ DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
■ Cisco memory from previous generation servers (DDR3 and DDR4) is not compatible with the
UCS B200 M6 Blade.
■ Memory can be configured in any number of DIMMs as pairs, although for optimal
performance, refer to the Cisco UCS C220/C240/B200 M6 Memory Guide.
■ For additional information, refer to Memory Configuration and Mirroring on page 46.
■ For detailed Intel® Optane™ Persistent Memory (PMem) configurations, refer to the B200
M6 Server Installation and Service Guide.

Cisco UCS B200 M6 Blade Server 15


CONFIGURING the SERVER

Approved Configurations

NOTE: Memory mirroring is allowed only with DIMMs; no memory mirroring can be
configured is PMem are installed.

(1) 1-CPU configuration without memory mirroring:

■ Select from 1 to 16 DIMMs.


— 1, 2, 4, 6, 8, 12, or 16 DIMMs allowed
— 3, 5, 7, 9, 10, 11, 13, 14, 15 DIMMs not allowed
— DIMMs for both CPUs must be configured identically.

The DIMMs will be placed by the factory as shown in the following table.

#DIMMs CPU 1 DIMM Placement in Channels (for identically ranked DIMMs)


1 (A1)
2 (A1, E1)
4 (A1, C1); (E1, G1)
6 (A1, C1); (D1, E1); (G1, H1)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1)
12 (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2, E2); (G2, H2)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, B2); (C2, D2); (E2, F2); (G2, H2)

(2) 1-CPU configuration with memory mirroring:

■ Select 8 or 16 DIMMs per CPU (DIMMs for all CPUs must be configured identically). In
addition, the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 14 must
be selected.

The DIMMs will be placed by the factory as shown in the following table.

# DIMMs
CPU 1 DIMM Placement in Channels (for identical ranked DIMMs)
Per CPU
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, B2); (C2, D2); (E2, F2); (G2, H2)

■ Select the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 14.

16 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

(3) 2-CPU configuration without memory mirroring:

■ Select from 1 to 16 DIMMs per CPU.


— 1, 2, 4, 6, 8, 12, or 16 DIMMs allowed
— 3, 5, 7, 9, 10, 11, 13, 14, 15 DIMMs not allowed
— DIMMs for both CPUs must be configured identically.

The DIMMs will be placed by the factory as shown in the following tables.

CPU 1 DIMM Placement in Channels (for CPU 2 DIMM Placement in Channels (for
#DIMMs
identically ranked DIMMs) identically ranked DIMMs)
1 (A1) (A1)
2 (A1, E1) (A1, E1)
4 (A1, C1); (E1, G1) (A1, C1); (E1, G1)
6 (A1, C1); (D1, E1); (G1, H1) (A1, C1); (D1, E1); (G1, H1)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1) (A1, C1); (D1, E1); (G1, H1); (B1, F1)
12 (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2, (A1, C1); (D1, E1); (G1, H1); (A2, C2); (D2,
E2); (G2, H2) E2); (G2, H2)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2,
B2); (C2, D2); (E2, F2); (G2, H2) B2); (C2, D2); (E2, F2); (G2, H2)

(4) 2-CPU configuration with memory mirroring:

■ Select 8 or 16 DIMMs per CPU (DIMMs for all CPUs must be configured identically). In
addition, the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 14 must
be selected.

The DIMMs will be placed by the factory as shown in the following tables.

# DIMMs CPU 1 DIMM Placement in Channels (for CPU 2 DIMM Placement in Channels (for
Per CPU identical ranked DIMMs) identically ranked DIMMs)
8 (A1, C1); (D1, E1); (G1, H1); (B1, F1) (A1, C1); (D1, E1); (G1, H1); (B1, F1)
16 (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2, (A1, B1); (C1, D1); (E1, F1); (G1, H1); (A2,
B2); (C2, D2); (E2, F2); (G2, H2) B2); (C2, D2); (E2, F2); (G2, H2)

■ Select the memory mirroring option (N01-MMIRROR) as shown in Table 6 on page 14.

NOTE: System performance is optimized when the DIMM type and quantity are equal
for both CPUs, and when all channels are filled equally across the CPUs in the server.

Cisco UCS B200 M6 Blade Server 17


CONFIGURING the SERVER

Table 7 3200-MHz DIMM Memory Speeds with Different Intel® Xeon® Ice Lake® Processors

RDIMM RDIMM  RDIMM 


DIMM and CPU LRDIMM (4Rx4)-
DPC (2Rx4) -  (2Rx4) -  (1Rx4) - 
Frequencies (MHz) 128 GB (MHz)
64 GB (MHz) 32 GB (MHz) 16 GB (MHz)

1.2 V 1.2 V 1.2 V 1.2 V

DIMM = 3200 1DPC 3200 3200 3200 3200


CPU = 3200
2DPC 3200 3200 3200 3200

DIMM = 3200 1DPC 2933 2933 2933 2933


CPU = 2933
2DPC 2933 2933 2933 2933

DIMM = 3200 1DPC 2666 2666 2666 2666


CPU = 2666
2DPC 2666 2666 2666 2666

DIMM Rules

■ Allowed DIMM count for 1 CPU:


■ Minimum DIMM count = 1; Maximum DIMM count = 16
■ 1, 2, 4, 6, 8, 12, or 16 DIMMs allowed
■ 3, 5, 7, 9, 10, 11, 13, 14, or 15 DIMMs not allowed.
■ Allowed DIMM count for 2 CPUs
■ Minimum DIMM count = 2; Maximum DIMM count = 32
■ 2, 4, 8, 12, 16, 24, or 32 DIMMs allowed
■ 6, 10, 14, 18, 20, 22, 26, 28, or 30 DIMMs not allowed.
■ DIMM Mixing:
■ Mixing different types of DIMM (RDIMM with LRDIMM) is not supported within a server.
■ Mixing RDIMM with RDIMM types is allowed if they are mixed in same quantities, in a
balanced configuration.
■ Mixing 16GB, 32GB, and 64GB RDIMMs is supported.
■ 128GB LRDIMMs cannot be mixed with other RDIMMs.

NOTE:
■ DIMM mixing is not allowed when PMem are installed; in these cases, all DIMMs
must be the same type and size.
■ See the detailed mixing DIMM configurations at the following link

Cisco UCS C220/C240/B200 M6 Memory Guide

18 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

See Table 8 for PMem memory modes. See Table 8 for allowed DIMM/PMem mixed configurations.

Table 8 Intel® OptaneTM Persistent Memory Modes

Intel® OptaneTM Persistent Memory Modes


App Direct Mode PMem operates as a solid-state disk storage device. Data is saved and is
non-volatile. Both DCPMM and DIMM capacities count towards the CPU
capacity limit.
Memory Mode PMem operates as a 100% memory module. Data is volatile and DRAM acts
as a cache for PMem. Only the PMem capacity counts towards the CPU
capacity limit). This is the factory default mode.

Table 9 3rd Gen Intel® Xeon® Scalable Processors (Ice Lake) Allowable Mixed DIMM/PMem1 Physical
Configuration (per socket)

DIMM +
PMem CPU 1 or CPU 2
Count

ICX: IMC2 ICX: IMC3 ICX: IMC1 ICX: IMC0


Chan 0 (F) Chan 1 (E) Chan 0 (H Chan 1 (G) Chan 0 (C) Chan 1 (D) Chan 0 (A) Chan 1 (B)
Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
1 2 1 2 1 2 1 2 2 1 2 1 2 1 2 1
4 + 42 PMem DIMM PMem DIMM DIMM PMem DIMM PMem

8 + 13 DIMM DIMM DIMM DIMM DIMM DIMM PMem DIMM DIMM

8 + 44 DIMM DIMM PMem DIMM DIMM PMem PMem DIMM DIMM PMem DIMM DIMM

8 + 85 DIMM PMem DIMM PMem DIMM PMem DIMM PMem PMem DIMM PMem DIMM PMem DIMM PMem DIMM
NOTE: AD = App Direct Mode, MM = Memory Mode

Notes:
1. All systems must be fully populated with two CPUs when using PMem at this time.
2. AD, MM
3. AD
4. AD, MM
5. AD, MM

For detailed Intel PMem configurations, refer to the Cisco UCS B200 M6 Server Installation and
Service Guide.

Cisco UCS B200 M6 Server Installation and Service Guide

For detailed DIMM/PMem informations, refer the UCS C220/C240/B200 M6 Memory Guide.

Cisco UCS C220/C240/B200 M6 Memory Guide

Cisco UCS B200 M6 Blade Server 19


CONFIGURING the SERVER

STEP 4 CHOOSE MLOM REAR MEZZANINE ADAPTER


The UCS B200 M6 must be ordered with a Cisco VIC mLOM Adapter. The adapter can operate in a
single-CPU or dual-CPU configuration. Table 11 shows available mLOM adapter choices.

Table 10 mLOM Adapters

Product ID (PID) Description Connector

UCSB-MLOM-40G-04 Cisco UCS VIC 1440 modular LOM for blade servers mLOM

UCSB-ML-V5Q10G Cisco UCS VIC 15411 modular LOM for Blade Servers mLOM

Table 11 Aggregate Bandwidth with mLOM Only configuration

Fabrics Extenders in UCS 5108 blade Fabric Interconnects Supported


mLOM
chassis aggregate bandwidth (Gb/s)

2x 2408 2x 2304 2x2208XP 2x2204XP 2x 2x 2x 2x 2x 2x


6324 6332 6332-16UP 6454 64108 6536

VIC
1440 40 40 40 20 Yes Yes Yes Yes Yes Yes
mLOM (20 Gbps)

VIC
15411 40 40 40 20 No Yes Yes Yes Yes Yes
mLOM

Cisco developed the 1400 Series and 15411 Virtual Interface Card (VIC) to provide flexibility to
create multiple NIC and HBA devices.The VIC features are listed here:

• Includes enhancements, including network overlay offload support.


• Provides two Converged Network Adapter (CNA) ports, supporting both Ethernet and FCoE
• Delivers up to 80 Gbps total I/O throughput to the server
• Supports 2x40 (native) Gbps Unified I/O ports
• Supports up to 256 fully functional unique and independent PCIe adapters and interfaces
• Provides virtual machine visibility from the physical network and a consistent network
operations model for physical and virtual servers
• Supports customer requirements for a wide range of operating systems and hypervisors

The mLOM VIC on the UCS B200 M6 enables connectivity to the Fabric Interconnect either
through the Fabric Extenders (FEX) or directly using the UCS 6324 Fabric Interconnect (UCS Mini)
on the UCS 5108 Blade Chassis.

20 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

The supported Fabric Extenders for the B200 M6 blades are

— Cisco UCS 2200 series Fabric Extenders


— Cisco UCS 2304 (v1) Fabric Extender
— Cisco UCS 2304 (v2) Fabric Extender
— Cisco UCS 2408 Fabric Extenders

The supported Fabric Interconnects for the B200 M6 blades are

— Cisco UCS 6300 series Fabric Interconnects


— Cisco UCS 6400 series Fabric Interconnects
— Cisco UCS 6536 Fabric Interconnect

Cisco UCS B200 M6 Blade Server 21


CONFIGURING the SERVER

STEP 5 CHOOSE OPTIONAL REAR MEZZANINE ADAPTERS (VIC or Port


Expander)
The UCS B200 M6 has one rear mezzanine adapter connector. The UCS B200 M6 can be ordered
with or without a rear mezzanine adapter. Refer to Table 12 Available Rear Mezzanine
Adapters for supported adapters.

Table 12 Available Rear Mezzanine Adapters

Product ID(PID) PID Description CPUs Required Connector

Port Expander Card for VIC


This is a hardware option to enable an additional 4 ports of the VIC 1440, bringing the total capability of the VIC 1440 to
a dual native 40G interface.

UCSB-MLOM-PT-01 Cisco UCS Port Expander Card for VIC 1 or 2 CPUs Rear Mezzanine

Cisco VIC Card

UCSB-VIC-M84-4P Cisco UCS VIC 1480 mezzanine adapter 2 CPUs required Rear Mezzanine

Supported Configurations

— Requires an mLOM (VIC 1440)

See Table 13 for aggregate bandwidths with various rear mezzanine cards installed.

Table 13 Aggregate Bandwidth with Rear Mezzanine Cards Installed

Fabric Extenders in UCS5108


Rear Mezz
blade chassis Aggregate Fabric Interconnects Support
Adapter
Bandwidth (Gb/s)

2x 2x 2x 2x 2x 2x 2x 2x 2x 2x
2408 2304 2208XP 2204XP 6324 6332 6332-16UP 6454 64108 65365

1440+
Yes
Port 801 802, 3 40 20 Yes Yes Yes Yes Yes
(20 Gbps)
Expander

VIC 1480 Yes


804 804 804 40 Yes Yes Yes Yes Yes5
(40 Gbps)

VIC 15411
+ Port 801 802,3 40 20 No Yes Yes Yes Yes Yes6,7
Expander

Notes:
1. Uses a dual native 40G interface. The maximum single-flow is 25 Gbps with an aggregate of 40 Gbps. To
avoid IOM/Fabric Extender transient drops due to a speed mismatch of 40 Gbps towards the server and 25
Gbps towards the fabric interconnect (FI), vNIC rate-limiting to 25 Gbps is recommended
2. Uses a dual native 40G interface
3. If operating in 4 x 10 mode, bandwidth drops down to 40 Gbps (two 2 x 10 G port-channeled)

22 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

4. Four 2x10 Gbps port-channels


5. The Cisco UCS 6536 Fabric Interconnect and/or VIC 1440 is supported with Intersight Managed Mode from
4.2(2) or greater and the UCSM support for FI 6536 is available with 4.2(3) release. The FI 6536 supported
only IOM- 2408 in 4.2(2) release and from 4.2(3) release supports both IOM-2408 and IOM-2304.
6. VIC 15411 is supported from 4.2(3) release in UCSM & IMM. 15411 is supported with M6 blades and with
FI-6332/6332-16UP/6454/64108/6536 with IOM 220x/2304/2408.
7. B200-M6 is supported only on the primary chassis with FI-6324 or UCS Mini.

Cisco UCS B200 M6 Blade Server 23


CONFIGURING the SERVER

STEP 6 CHOOSE OPTIONAL FRONT MEZZANINE ADAPTER


The UCS B200 M6 has one front mezzanine connector that can accommodate one of the
following mezzanine cards:

■ Cisco FlexStorage 12G RAID controller with 2 drive bays, or


■ Cisco FlexStorage Pass-through module with 2 drive bays, or
■ Cisco FlexStorage Mini Storage carrier for SATA M.2 RAID storage. UCS-M2-HWRAID is
required when selecting the M.2 SATA drives.

The UCS B200 M6 can be ordered with or without the front mezzanine adapter. Refer to Table
14 Available Front Mezzanine Adapters.

Table 14 Available Front Mezzanine Adapters

Product ID(PID) PID Description Connector Type

UCSB-RAID12G-M6 Cisco FlexStorage 12G RAID controller with drive Front Mezzanine
bays for two SAS/SATA solid state drives (SSDs).

UCSB-LSTOR-PT-M6 Cisco FlexStorage pass-through module with drive Front Mezzanine


bays for two PCIe NVMe drives.

UCSB-MSTOR-M61 Mini storage carrier that holds up to two SATA M.2 Front Mezzanine
RAID cards.

Notes:
1. The B200 M6 can accommodate one UCSB-MSTOR-M6 mini-storage carrier. The carrier can hold up to two
UCS-M2-HWRAID boot-optimized RAID controllers (see Cisco 6GB/s SATA Boot-Optimized M.2 RAID Controller
on page 28). Up to two SATA M.2 drive cards plug into each UCS-M2-HWRAID, so you can have a maximum of
four SATA M.2 cards. The SATA M.2 cards plugged into the same UCS-M2-HWRAID RAID controller must be the
same capacity.

24 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

STEP 7 CHOOSE OPTIONAL DRIVES


The UCS B200 M6 can be ordered with or without drives. The drive options are:

■ One or two 2.5-inch (7 mm) small form factor SSDs or PCIe NVMe drives
— Hot-pluggable
— Sled-mounted
■ Up to two SATA M.2 storage modules can be selected to be plugged into each
UCS-M2-HWRAID module, which is then plugged into the UCSB-MSTOR-M6 mini storage
carrier. Two SATA M.2 storage modules in the same UCS-M2-HWRAID module must be the
same capacity.

Select one or two drives from the list of supported drives available in Table 15.

Table 15 Available Drive Options

Performance
Drive
Product ID (PID) Description Speed /Endurance Size
Type
/Value
SATA SSDs1,2,3
Enterprise Performance SSDs (high endurance, supports up to 3X DWPD (drive writes per day))
UCS-SD480GBI6-EP 480 GB 2.5in Enterprise SATA 6G Ent. Perf 3X 480 GB
performance 6G SATA SSD 
(3X endurance) Intel S4610
UCS-SD960GBI6-EP 960 GB 2.5in Enterprise SATA 6G Ent. Perf 3X 960 GB
performance 6G SATA SSD 
(3X endurance) Intel S4610
UCS-SD19TBI6-EP 1.9 TB 2.5in Enterprise SATA 6G Ent. Perf 3X 1.9 TB
performance 6G SATA SSD
(3X endurance) Intel S4610
UCS-SD480GBM6-EP 480 GB 2.5in Enterprise SATA 6G Ent. Perf 3X 480 GB
performance 6G SATA SSD
(3X endurance) Micron 5300
UCS-SD960GBM6-EP 960 GB 2.5in Enterprise SATA 6G Ent. Perf 3X 960 GB
performance 6G SATA SSD
(3X endurance) Micron 5300
UCS-SD19TM6-EP 1.9 TB 2.5in Enterprise SATA 6G Ent. Perf 3X 1.9 TB
performance 6G SATA SSD
(3X endurance) Micron 5300
UCS-SD19TBM6-EP 1.9TB Enterprise value SATA SSD SATA 6G Ent. Perf 1X 1.9 TB
(1X , SED)
UCS-SD960GM6-EP 960GB 2.5in Enterprise SATA 6G Ent. Perf 3X 960 GB
performance 6GSATA SSD(3X
endurance)
UCS-SD480GM6-EP 480GB 2.5in Enterprise SATA 6G Ent. Perf 3X 480 GB
performance 6GSATA SSD(3X
endurance)

Cisco UCS B200 M6 Blade Server 25


CONFIGURING the SERVER

Table 15 Available Drive Options (continued)

Performance
Drive
Product ID (PID) Description Speed /Endurance Size
Type
/Value
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
UCS-SD240GM6-EV 240 GB 2.5 inch Enterprise Value SATA 6G Ent. Value 240 GB
6G SATA SSD Micron 5300
UCS-SD480GI6-EV 480 GB 2.5 inch Enterprise Value SATA 6G Ent. Value 480 GB
6G SATA SSD Intel S4510
UCS-SD960GI6-EV 960 GB 2.5 inch Enterprise Value SATA 6G Ent. Value 960 GB
6G SATA SSD Intel S4510
UCS-SD16TM6-EV 1.6 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 1.6 TB
6G SATA SSD Micron 5300
UCS-SD19TM6-EV 1.9 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 1.9 TB
6G SATA SSD Micron 5300
UCS-SD38TM6-EV 3.8 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 3.8 TB
6G SATA SSD Micron 5300
UCS-SD38TI6-EV 3.8 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 3.8 TB
6G SATA SSD Intel S4510
UCS-SD76TM6-EV 7.6 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 7.6 TB
6G SATA SSD Micron 5300
UCS-SD38TS6-EV 3.8 TB 2.5 inch Enterprise Value SATA 6G Ent. Value 3.8 TB
6G SATA SSD Samsung PM883
UCS-SD480GM6-EV 480 GB 2.5 inch Enterprise Value SATA 6G Ent. Value 480 GB
6G SATA SSD Micron 5300
UCS-SD960GM6-EV 960 GB 2.5 inch Enterprise Value SATA 6G Ent. Value 960 GB
6G SATA SSD Micron 5300
UCS-SD960GS26-EV 960GB 2.5 inch Enterprise Value SATA 6G Ent. Value 960 GB
6G SATA SSD
UCS-SD19TS26-EV 1.9TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 1.9 TB
SATA SSD
UCS-SD78TS26-EV 7.6TB 2.5 inch Enterprise Value 6G SATA 6G Ent. Value 7.6 TB
SATA SSD
UCS-SDC960SA1V 960GB 2.5in 6G SATA Enter Value SATA 6G Ent. Value 960 GB
1X Samsung G1PM893A SSD
UCS-SDC1T9SA1V 1.9TB 2.5in 6G SATA Enter Value SATA 6G Ent. Value 1.9 TB
1X Samsung G1PM893A SSD
UCS-SDC3T8SA1V 3.8TB 2.5in 6G SATA Enter Value SATA 6G Ent. Value 3.8 TB
1X Samsung G1PM893A SSD
UCS-SDC7T6SA1V 7.6TB 2.5in 6G SATA Enter Value SATA 6G Ent. Value 7.6 TB
1X Samsung G1PM893A SSD
NVMe4
UCSB-NVMEM6-M7600 7.6TB 2.5in U.3 7mm Micron 7450 NVMe U.3 Med. Perf 7.6 TB
Hg Perf Med End NVMe (1X) High End.

26 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Table 15 Available Drive Options (continued)

Performance
Drive
Product ID (PID) Description Speed /Endurance Size
Type
/Value
UCSB-NVMEM6-M1920 1.9TB 2.5in U.3 7mm Micron 7450 NVMe U.3 High. Perf 1.9 TB
Hg Perf Med End NVMe (1X) Med End.
UCSB-NVMEM6-M3800 3.8TB 2.5in U.3 7mm Micron 7450 NVMe U.3 High. Perf 3.8 TB
Hg Perf Med End NVMe (1X) Med End.
UCSB-NVMEM6-M800 800GB 2.5in U.3 7mm Micron 7450 NVMe U.3 High. Perf 800 GB
Hg Perf Hg End NVMe (3X) Med End.
UCSB-NVMEM6-M6400 6.4TB 2.5in U.3 7mm Micron 7450 NVMe U.3 High. Perf 6.4 TB
Hg Perf Hg End NVMe (3X) Med End.
Self-Encrypted Drives (SED)
UCS-SD19TM6NK9 1.9TB 2.5in Enterprise SED Ent. Value 1.9 TB
performance 6GSATA SSD(3X
endurance)
UCS-SD38TM6NK9 3.8TB Enterprise Value SATA SSD SED Ent. Value 3.8 TB
(1X, SED)
UCS-SD76TM6NK9 7.6TB Enterprise Value SATA SSD SED Ent. Value 7.6 TB
(1X, SED)
UCS-SD960GM6NK9 960GB Enterprise Value SATA SSD SED Ent. Value 960 GB
(1X , SED)
SATA M.2 Storage Modules5
UCS-M2-240G 240GB SATA M.2 SATA M.2 240 GB
UCS-M2-480G 480GB M.2 SATA SSD SATA M.2 480 GB
UCS-M2-960G 960GB SATA M.2 SATA M.2 960 GB
UCS-M2-192TB 1.9TB SATA M.2 SATA M.2 1.9 TB
UCS-M2-I240GB 240GB M.2 Boot SATA Intel SSD SATA M.2 240 GB
UCS-M2-I480GB 480GB M.2 Boot SATA Intel SSD SATA M.2 480 GB
NOTE: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state drives (SSDs) are
subject to physical write limits and have varying maximum usage limitation specifications set by the
manufacturer. Cisco will not replace any solid state drives (SSDs) that have exceeded any maximum usage
specifications set by Cisco or the manufacturer, as determined solely by Cisco.
Notes:
1. SSD drives require the UCSB-MRAID-M6 front mezzanine adapter
2. For SSD drives to be in a RAID group, two identical SSDs must be used in the group.
3. If SSDs are in JBOD Mode, the drives do not need to be identical.
4. NVMe drives require the UCSB-LSTOR-PT front mezzanine adapter
5. UCS-M2-HWRAID is needed with M.2 Storage Modules.

Cisco UCS B200 M6 Blade Server 27


CONFIGURING the SERVER

Cisco 6GB/s SATA Boot-Optimized M.2 RAID Controller

If you order M.2 SATA drives, you must select the boot-optimized RAID controller
(UCS-M2-HWRAID) for hardware RAID across each one or two SATA M.2 drives. You must also
select one UCSB-MSTOR-M6 mini storage carrier. The RAID controller plugs into the
UCSB-MSTOR-M6 mini-storage carrier and up to two SATA M.2 drives plug into the
UCS-M2-HWRAID RAID controller.

Note: The Boot-Optimized RAID controller supports Windows and Linux Operating Systems.

Table 16 Boot-Optimized RAID controller

Product ID (PID) PID Description

UCS-M2-HWRAID Cisco Boot optimized M.2 RAID controller

NOTE:
■ The UCS-M2-HWRAID controller supports RAID 1 and JBOD mode and is available only
with 240 GB and 960 GB M.2 SATA SSDs.
■ (CIMC/UCSM) is supported for configuring of volumes and monitoring of the controller
and installed SATA M.2 drives
■ The minimum version of Cisco IMC and Cisco UCS Manager that support the controller
is 4.0(4) and later. The name of the controller in the software is MSTOR-RAID
■ The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported
■ Hot-plug replacement is not supported. The server must be powered off.

28 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Intel® Virtual RAID on CPU (Intel® VROC)


The server supports Intel® Virtual RAID on CPU (Intel® VROC). VROC is an enterprise RAID solution used with
Intel NVMe SSDs (see Table 15 for supported Intel NVMe SSDs). The Intel® Volume Management Device
(Intel® VMD) is a controller integrated into the CPU PCIe root complex. Intel® VMD NVMe SSDs are
connected to the CPU, which allows the full performance potential of fast Intel® Optane™ SSDs to be
realized. Intel® VROC, when implemented, replaces traditional hardware RAID host bus adapter (HBA)
cards placed between the drives and the CPU.

NOTE:
■ Intel® VROC is only supported with Intel drives
■ Intel® VROC enablement key factory pre-provisioned to BIOS - no additional licensing
required.

VROC has the following features:

■ Small Form Factor (SFF) drive support (only)


■ No battery backup (BBU) or external SuperCap needed
■ Software-based solution utilizing Intel SFF NVMe direct connected to Intel CPU
■ RAID 0/1/5/10 support
■ Windows, Linux OS support.
■ Host Tools- Windows GUI/CLI, Linux CLI.
■ UEFI Support- HII Utility, OBSE.
■ Intel VROC NVMe operates in UEFI mode only
See the instructions on setting up and managing VROC for Intel NVMe SSDs for more
information.

Cisco UCS B200 M6 Blade Server 29


CONFIGURING the SERVER

STEP 8 CHOOSE TRUSTED PLATFORM MODULE


Trusted Platform Module (TPM) is a computer chip or microcontroller that can securely store
artifacts used to authenticate the platform or server. These artifacts can include passwords,
certificates, or encryption keys. A TPM can also be used to store platform measurements that
help ensure that the platform remains trustworthy. Authentication (ensuring that the platform
can prove that it is what it claims to be) and attestation (a process helping to prove that a
platform is trustworthy and has not been breached) are necessary steps to ensure safer
computing in all environments.

Table 17 Available TPM Option

Product ID (PID) Description

UCSX-TPM-002C TPM 2.0, TCG, FIPS140-2, CC EAL4+ Certified, for M6 servers

UCS-TPM-002D TPM 2.0 TCG FIPS140-2 CC+ Cert M6 Intel MSW2022 Compliant

UCSX-TPM-OPT-OUT OPT OUT, TPM 2.0, TCG, FIPS140-2, CC EAL4+ Certified1

Notes:
1. Please note that Microsoft certification requires a TPM 2.0 for bare-metal or guest VM deployments. Opt-out of
the TPM 2.0 voids the Microsoft certification

NOTE:
■ The TPM module used in this system conforms to TPM v2.0 as defined by the
Trusted Computing Group (TCG).
■ TPM installation is supported after-factory. However, a TPM installs with a
one-way screw and cannot be replaced, upgraded, or moved to another server. If
a server with a TPM is returned, the replacement server must be ordered with a
new TPM. If there is no existing TPM in the server, you can install TPM 2.0. Refer
to the following document for Installation location and instructions: Cisco UCS
B200 M6 Server Installation Guide.

30 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

STEP 9 CHOOSE UCSM SOFTWARE


A UCSM software version needs to be selected for the standalone UCS B200 M6 Blade PID
(UCSB-B200-M6-UPG).

NOTE:
• This is a new mandatory option for standalone blades starting with the UCS
B200 M6.
• When the UCS B200 M6 is configured inside of a chassis in the CCW ordering
tool, the UCSM software version is selected at the chassis level. The software
option will not be available under the UCS B200 M6 in that case.
• The recommended UCS releases for the UCS B200 M6 is UCSM 4.2(1). This
release supports higher wattage CPUs. FI 6454 and/or VIC 1400 require
release UCSM 4.0(1) or greater.

Choose one software PID from Table 18.

Table 18 Available UCSM Software

Product ID (PID) Product Description Software Version

N20-FW018 UCS 5108 Blade Chassis FW Package 4.2 UCSM 4.2

Cisco UCS B200 M6 Blade Server 31


CONFIGURING the SERVER

STEP 10 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE

NOTE:
■ See this link for operating system guidance:
https://ucshcltool.cloudapps.cisco.com/public/

For more details on supported operating systems and software for this server, see the Hardware
and Software Compatibility List (HCL

Select

■ Operating System (Table 19)

Table 19 Operating System

Product ID (PID) PID Description

Microsoft Windows Server

MSWS-19-DC16C Windows Server 2019 Data Center (16 Cores/Unlimited VMs)

MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC

MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)

MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC

MSWS-22-DC16C Windows Server 2022 Data Center (16 Cores/Unlimited VMs)

MSWS-22-DC16C-NS Windows Server 2022 DC (16 Cores/Unlim VMs) - No Cisco SVC

MSWS-22-DCA2C Windows Server 2022 Data Center - Additional 2 Cores

MSWS-22-DCA2C-NS Windows Server 2022 DC - Additional 2 Cores - No Cisco SVC

MSWS-22-ST16C Windows Server 2022 Standard (16 Cores/2 VMs)

MSWS-22-ST16C-NS Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC

MSWS-22-STA2C Windows Server 2022 Standard - Additional 2 Cores

MSWS-22-STA2C-NS Windows Server 2022 Stan - Additional 2 Cores - No Cisco SVC

Red Hat

RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req

RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req

RHEL-2S2V-5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req

RHEL-VDC-2SUV-1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req

32 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Table 19 Operating System (continued)

Product ID (PID) PID Description

RHEL-VDC-2SUV-3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req

RHEL-VDC-2SUV-5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req

Red Hat Ent Linux/ High Avail/ Res Strg/ Scal

RHEL-2S2V-1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1-Yr SnS

RHEL-2S2V-3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3-Yr SnS

RHEL-2S-HA-1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS

RHEL-2S-HA-3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS

RHEL-2S-RS-1S RHEL Resilient Storage (1-2 CPU); Premium 1-yr SnS

RHEL-2S-RS-3S RHEL Resilient Storage (1-2 CPU); Premium 3-yr SnS

RHEL-VDC-2SUV-1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd

RHEL-VDC-2SUV-3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd

Red Hat SAP

RHEL-SAP-2S2V-1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS

RHEL-SAP-2S2V-3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS

SUSE

SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req

SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req

SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req

SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS

SLES-2S2V-3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS

SLES-2S2V-5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS

SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS

SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS

SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS

SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns

SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS

SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS

SLES-2S-LP-1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required

SLES-2S-LP-3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required

Cisco UCS B200 M6 Blade Server 33


CONFIGURING the SERVER

Table 19 Operating System (continued)

Product ID (PID) PID Description

SLES-2S-LP-1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req

SLES-2S-LP-3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req

SLES and SAP

SLES-SAP-2S2V-1A SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd

SLES-SAP-2S2V-3A SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd

SLES-SAP-2S2V-5A SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd

SLES-SAP-2S2V-1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS

SLES-SAP-2S2V-3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS

SLES-SAP-2S2V-5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS

34 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

STEP 11 CHOOSE OPTIONAL RECOVERY MEDIA


Select the optional recovery media listed in Table 20

Table 20 OS Media

Product ID (PID) PID Description

MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-22-ST16C-RM Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-22-DC16C-RM Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only

Cisco UCS B200 M6 Blade Server 35


CONFIGURING the SERVER

STEP 12 CHOOSE SERVICE and SUPPORT LEVEL


A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract


If you have noncritical implementations and choose to have no service contract, the following
coverage is supplied:

• Three-year parts coverage.


• Next business day (NBD) parts replacement eight hours a day, five days a week.
• 90-day software warranty on media.
• Ongoing downloads of BIOS, drivers, and firmware updates.
• UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM
with published specifications, release notes, and industry standards.

Smart Net Total Care (SNTC) for Cisco UCS


For support of the entire Unified Computing System, Cisco offers the Cisco Smart Net Total Care
(SNTC) for UCS Service. This service provides expert software and hardware support to help
sustain performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For systems that include Unified Computing System Manager (UCSM), the support service
includes downloads of UCSM upgrades. The Cisco Smart Net Total Care for UCS Service includes
flexible hardware replacement options, including replacement in as little as two hours. There is
also access to Cisco's extensive online technical resources to help maintain optimal efficiency
and uptime of the unified computing environment. For more information please refer to the
following URL:

http://www.cisco.com/c/en/us/services/technical/smart-net-total-care.html?stickynav=1

You can choose a desired service listed in Table 21.

Table 21 Cisco SNTC for UCS Service (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-PREM-UCSBB2M6 C2P Yes SNTC 24X7X2OS


CON-UCSD8-UCSBB2M6 UCSD8 Yes UC SUPP DR 24X7X2OS*
CON-C2PL-UCSBB2M6 C2PL Yes LL 24X7X2OS**
CON-OSP-UCSBB2M6 C4P Yes SNTC 24X7X4OS

CON-UCSD7-UCSBB2M6 UCSD7 Yes UCS DR 24X7X4OS*

36 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Table 21 Cisco SNTC for UCS Service (PID UCSB-B200-M6) (continued)

Service SKU Service Level GSP On Site? Description

CON-C4PL-UCSBB2M6 C4PL Yes LL 24X7X4OS**

CON-USD7L-UCSBB2M6 USD7L Yes LLUCS HW DR 24X7X4OS***

CON-OSE-UCSBB2M6 C4S Yes SNTC 8X5X4OS

CON-UCSD6-UCSBB2M6 UCSD6 Yes UC SUPP DR 8X5X4OS*

CON-SNCO-UCSBB2M6 SNCO Yes SNTC 8x7xNCDOS****

CON-OS-UCSBB2M6 CS Yes SNTC 8X5XNBDOS

CON-UCSD5-UCSBB2M6 UCSD5 Yes UCS DR 8X5XNBDOS*

CON-S2P-UCSBB2M6 S2P No SNTC 24X7X2

CON-S2PL- UCSBB2M6 S2PL No LL 24X7X2**

CON-SNTP-UCSBB2M6 SNTP No SNTC 24X7X4

CON-SNTPL-UCSBB2M6 SNTPL No LL 24X7X4**

CON-SNTE-UCSBB2M6 SNTE No SNTC 8X5X4

CON-SNC-UCSBB2M6 SNC No SNTC 8x7xNCD

CON-SNT-UCSBB2M6 SNT No SNTC 8X5XNBD

CON-SW-UCSBB2M6 SW No SNTC NO RMA

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-OSP-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-OSP-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-OSP-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-OSP-UCSB2M6UB)

*Includes Drive Retention (see below for full description)

**Includes Local Language Support (see below for full description) – Only available in China and Japan

***Includes Local Language Support and Drive Retention – Only available in China and Japan

Cisco UCS B200 M6 Blade Server 37


CONFIGURING the SERVER

Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service
An enhanced offer over traditional Smart Net Total Care which provides onsite troubleshooting
expertise to aid in the diagnostics and isolation of hardware issue within our customers’ Cisco
Unified Computing System (UCS) environment. It is delivered by a Cisco Certified field engineer
(FE) in collaboration with remote TAC engineer and Virtual Internetworking Support Engineer
(VISE). You can choose a desired service listed in Table 22.

Table 22 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-OSPT-UCSBB2M6 OSPT Yes 24X7X4OS Trblshtg


CON-OSPTD-UCSBB2M6 OSPTD Yes 24X7X4OS TrblshtgDR*

CON-OSPTL-UCSBB2M6 OSPTL Yes 24X7X4OS TrblshtgLL**

CON-OPTLD-UCSBB2M6 OPTLD Yes 24X7X4OS TrblshtgLLD***

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-OSPT-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-OSPT-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-OSPT-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-OSPT-UCSB2M6UB)

*Includes Drive Retention (see below for full description)

**Includes Local Language Support (see below for full description) – Only available in China and Japan

***Includes Local Language Support and Drive Retention – Only available in China and Japan

38 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Solution Support for UCS


Solution Support includes both Cisco product support and solution-level support, resolving
complex issues in multivendor environments, on average, 43% more quickly than product
support alone. Solution Support is a critical element in data center administration, to help
rapidly resolve any issue encountered, while maintaining performance, reliability, and return on
investment.

This service centralizes support across your multivendor Cisco environment for both our
products and solution partner products you’ve deployed in your ecosystem. Whether there is an
issue with a Cisco or solution partner product, just call us. Our experts are the primary point of
contact and own the case from first call to resolution. For more information please refer to the
following URL:

http://www.cisco.com/c/en/us/services/technical/solution-support.html?stickynav=1
You can choose a desired service listed in Table 23..

Table 23 Solution Support for UCS Service (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-SSC2P-UCSBB2M6 SSC2P Yes SOLN SUPP 24X7X2OS


CON-SSC4P-UCSBB2M6 SSC4P Yes SOLN SUPP 24X7X4OS

CON-SSC4S-UCSBB2M6 SSC4S Yes SOLN SUPP 8X5X4OS

CON-SSCS-UCSBB2M6 SSCS Yes SOLN SUPP 8X5XNBDOS

CON-SSDR7-UCSBB2M6 SSDR7 Yes SSPT DR 24X7X4OS*

CON-SSDR5-UCSBB2M6 SSDR5 Yes SSPT DR 8X5XNBDOS*

CON-SSS2P-UCSBB2M6 SSS2P No SOLN SUPP 24X7X2

CON-SSSNP-UCSBB2M6 SSSNP No SOLN SUPP 24X7X4

CON-SSSNE-UCSBB2M6 SSSNE No SOLN SUPP 8X5X4

CON-SSSNC-UCSBB2M6 SSSNC No SOLN SUPP NCD

CON-SSSNT-UCSBB2M6 SSSNT No SOLN SUPP 8X5XNBD

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-SSC4P-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-SSC4P-UCSB2M6C

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-SSC4P-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-SSC4P-UCSB2M6UB)

*Includes Drive Retention (see below for full description)

Cisco UCS B200 M6 Blade Server 39


CONFIGURING the SERVER

Smart Net Total Care for UCS Hardware Only Service


For faster parts replacement than is provided with the standard Cisco Unified Computing System
warranty, Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can
choose from two levels of advanced onsite parts replacement coverage in as little as four hours.
Smart Net Total Care for UCS Hardware Only Service provides remote access any time to Cisco
support professionals who can determine if a return materials authorization (RMA) is required.
You can choose a desired service listed in Table 24.

.
Table 24 SNTC for UCS Hardware Only Service (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-UCW7-UCSBB2M6 UCW7 Yes UCS HW 24X7X4OS


CON-UCWD7-UCSBB2M6 UCWD7 Yes UCS HW+DR 24X7X4OS*

CON-UCW7L-UCSBB2M6 UCW7L Yes LL UCS 24X7X4OS**

CON-UWD7L-UCSBB2M6 UWD7L Yes LL UCS DR 24X7X4OS***

CON-UCW5-UCSBB2M6 UCW5 Yes UCS HW 8X5XNBDOS

CON-UCWD5-UCSBB2M6 UCWD5 Yes UCS HW+DR 8X5XNBDOS*

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-UCW7-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-UCW7-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-UCW7-UCSB2M6B)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-UCW7-UCSB2M6UB)

*Includes Drive Retention (see below for full description)

**Includes Local Language Support (see below for full description) – Only available in China and Japan

***Includes Local Language Support and Drive Retention – Only available in China and Japan

40 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Partner Support Service for UCS


Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is
designed for partners to deliver their own branded support and managed services to enterprise
customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to
help them:

■ Expand their service portfolios to support the most complex network environments
■ Lower delivery costs
■ Deliver services that increase customer loyalty

PSS options enable eligible Cisco partners to develop and consistently deliver high-value
technical support that capitalizes on Cisco intellectual assets. This helps partners to realize
higher margins and expand their practice. PSS is available to all Cisco PSS partners.The two
Partner Unified Computing Support Options include:

■ Partner Support Service for UCS


■ Partner Support Service for UCS Hardware Only

PSS for UCS provides hardware and software support, including triage support for third party
software, backed by Cisco technical resources and level three support. You can choose a desired
service listed in Table 25.

Table 25 PSS for UCS (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-PSJ8-UCSBB2M6 PSJ8 Yes UCS PSS 24X7X2 OS

CON-PSJ7-UCSBB2M6 PSJ7 Yes UCS PSS 24X7X4 OS

CON-PSJD7-UCSBB2M6 PSJD7 Yes UCS PSS 24X7X4 DR*

CON-PSJ6-UCSBB2M6 PSJ6 Yes UCS PSS 8X5X4 OS

CON-PSJD6-UCSBB2M6 PSJD6 Yes UCS PSS 8X5X4 DR*


CON-PSJ4-UCSBB2M6 PSJ4 No UCS SUPP PSS 24X7X2
CON-PSJ3-UCSBB2M6 PSJ3 No UCS SUPP PSS 24X7X4

CON-PSJ2-UCSBB2M6 PSJ2 No UCS SUPP PSS 8X5X4

CON-PSJ1-UCSBB2M6 PSJ1 No UCS SUPP PSS 8X5XNBD

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-PSJ7-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-PSJ7-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-PSJ7-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example:

*Includes Drive Retention (see below for full description)

Cisco UCS B200 M6 Blade Server 41


CONFIGURING the SERVER

PSS for UCS Hardware Only


PSS for UCS Hardware Only provides customers with replacement parts in as little as two hours
and provides remote access any time to Partner Support professionals who can determine if a return
materials authorization (RMA) is required. You can choose a desired service listed in Table 26.

Table 26 PSS for UCS Hardware Only (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-PSW7-UCSBB2M6 PSW7 Yes UCS W PSS 24X7X4 OS

CON-PSWD7-UCSBB2M6 PSWD7 Yes UCS W PSS 24X7X4 DR*

CON-PSW6-UCSBB2M6 PSW6 Yes UCS W PSS 8X5X4 OS

CON-PSWD6-UCSBB2M6 PSWD6 Yes UCS W PSS 8X5X4 DR*

CON-PSW4-UCSBB2M6 PSW4 No UCS W PL PSS 24X7X2

CON-PSW3-UCSBB2M6 PSW3 No UCS W PL PSS 24X7X4

CON-PSW2-UCSBB2M6 PSW2 No UCS W PL PSS 8X5X4

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-PSW7-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-PSW7-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-PSW7-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-PSW7-UCSB2M6UB)

*Includes Drive Retention (see below for full description)

42 Cisco UCS B200 M6 Blade Server


CONFIGURING the SERVER

Unified Computing Combined Support Service


Combined Services makes it easier to purchase and manage required services under one
contract. SNTC services for UCS help increase the availability of your vital data center
infrastructure and realize the most value from your unified computing investment. The more
benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important
the technology becomes to your business. These services allow you to:

■ Optimize the uptime, performance, and efficiency of your UCS


■ Protect your vital business applications by rapidly identifying and addressing issues
■ Strengthen in-house expertise through knowledge transfer and mentoring
■ Improve operational efficiency by allowing UCS experts to augment your internal staff
resources
■ Enhance business agility by diagnosing potential issues before they affect your operations

You can choose a desired service listed in Table 27

Table 27 Combined Support Service for UCS (PID UCSB-B200-M6)

Service SKU Service Level GSP On Site? Description

CON-NCF2P-UCSBB2M6 NCF2P Yes CMB SVC 24X7X2OS


CON-NCF4P-UCSBB2M6 NCF4P Yes CMB SVC 24X7X4OS

CON-NCF4S-UCSBB2M6 NCF4S Yes CMB SVC 8X5X4OS

CON-NCFCS-UCSBB2M6 NCFCS Yes CMB SVC 8X5XNBDOS

CON-NCF2-UCSBB2M6 NCF2 No CMB SVC 24X7X2

CON-NCFP-UCSBB2M6 NCFP No CMB SVC 24X7X4

CON-NCFE-UCSBB2M6 NCFE No CMB SVC 8X5X4

CON-NCFT-UCSBB2M6 NCFT No CMB SVC 8X5XNBD

CON-NCFW-UCSBB2M6 NCFW No CMB SVC SW

Note: For PID UCSB-B200-M6-U, select Service SKU with UCSB2M6U suffix (Example: CON-NCF4P-UCSB2M6U)

For PID UCSB-B200-M6-CH, select Service SKU with UCSB2M6C suffix (Example: CON-NCF4P-UCSB2M6C)

For PID UCSB-B200-M6-BR, select Service SKU with UCSB2M6B suffix (Example: CON-NCF4P-UCSB2M6B)

For PID UCSB-B200-M6-U-BR, select Service SKU with UCSB2M6UB suffix (Example: CON-NCF4P-UCSB2M6UB)

Cisco UCS B200 M6 Blade Server 43


CONFIGURING the SERVER

UCS Drive Retention Service


With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in
exchange for a faulty drive without returning the faulty drive.

Sophisticated data recovery techniques have made classified, proprietary, and confidential
information vulnerable, even on malfunctioning disk drives. The Drive Retention service enables
you to retain your drives and ensures that the sensitive data on those drives is not compromised,
which reduces the risk of any potential liabilities. This service also enables you to comply with
regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in the above tables (where
available).

NOTE: Cisco does not offer a certified drive destruction service as part of this
service.

Local Language Technical Support for UCS


Where available, and subject to an additional fee, local language support for calls on all
assigned severity levels may be available for specific product(s) – see tables above.

For a complete listing of available services for Cisco Unified Computing System, see the following
URL:

http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

44 Cisco UCS B200 M6 Blade Server


SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL
System Board
A top view of the UCS B200 M6 system board is shown in Figure 4.

Figure 4 UCS B200 M6 System Board

1 5 4 3 5 2 6 7

P2 F1 P2 E1 P1 B1

Front P2 F2
P2 H1
P2 E2
P1 A1
P1 B2
P1 D1
P2 H2 P1 A2 P1 D2
P2 G1 P1 C1
P2 G2 P1 C2

P2 C2 P2 G2
P2 C1 P1 G1
P2 D2 P1 E2 P1 H2
P2 D1 P1 E1 P1 H1

307904
P2 B2 P2 A2 P1 F2
P2 B1 P2 A1 P1 F1

1 Front mezzanine connector 5 CPU heatsink install guide pins


2 DIMM slots 6 mLOM connector
DIMMs are secured by white or yellow latches
White latches indicate the memory is connected to CPU
1
Yellow latches indicate the memory is connected to CPU
2
3 CPU socket 1 (populated) 7 Rear mezzanine connector
CPU 1 connects to DIMMs with a white DIMM latch
This CPU socket must always be populated
4 CPU socket 2 (unpopulated) - -
CPU 2 connects to DIMMs with a yellow DIMM latch
This CPU socket is populated in a normal, dual-CPU
deployment. If your server will run with only one CPU,
the CPU must be installed in CPU socket 1.

CAUTION: The DIMMs installed in sockets with yellow latches are oriented
180 degrees with respect to the DIMMs in the sockets with white latches.
Make sure to align the notch keys in DIMMs with the keys in the sockets
before inserting to avoid damage to DIMM.

Cisco UCS B200 M6 Blade Server 45


SUPPLEMENTAL MATERIAL

Memory Configuration and Mirroring


When the Memory Mirroring PID (N01-MMIRROR) is selected in Table 6 Available DDR4 DIMMs
and PMem, page 14, the DIMMS will be placed as shown in Table 29 on page 48 by the factory

Each CPU has eight DIMM channels:

■ CPU1 (P1) has channels A, B, C, D, E, F, G, and H


■ CPU2 (P2) has channels A, B, C, D, E, F, G, and H

Each DIMM channel has two slots: slot 1 and slot 2. The blue-colored DIMM slots are for slot 1 and
the black slots for slot 2.

As an example, DIMM slots A1, B1, C1, D1, E1, F1, G1, and H1 belong to slot 1, while A2, B2, C2,
D2, E2, F2, G2, and H2 belong to slot 2.

Figure 4 on page 45 shows how slots and channels are physically laid out on the motherboard.
The DIMM slots for channels A, B, C, D, E, F, G, and H are associated with CPU 1 (P1), while the
DIMM slots for channels A, B, C, D, E, F, G, and H are associated with CPU 2 (P2). The slot 1
(blue) DIMM slots are always located farther away from a CPU than the corresponding slot 2
(black) slots.

For all allowable DIMM populations, please refer to the “Memory Population Guidelines” section
of the B200 M6 Service and Installation Guide.

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M6.p
df

For more details, see the Cisco UCS C220/C240/B200 M6 memory Guide.

https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-c-se
ries-rack-servers/c220-c240-b200-m6-memory-guide.pdf

When considering the memory configuration of your server, consider the following items:

■ Each channel has two DIMM slots (for example, channel A = slots A1 and A2).
— A channel can operate with one or two DIMMs installed.
■ When both CPUs are installed, populate the DIMM slots of each CPU identically.
■ Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.
■ Observe the DIMM mixing rules shown in Table 28 on page 47.

46 Cisco UCS B200 M6 Blade Server


SUPPLEMENTAL MATERIAL

Table 28 DIMM Rules for B200 M6 Servers

DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot1

DIMM Capacity DIMMs in the same channel (for For best performance, DIMMs in
RDIMM = 16, 32, or 64 GB example, A1 and A2) can have the same slot (for example, A1,
different capacities. B1, C1, D1, E1, F1, G1, H1) should
LRDIMM = 128 GB
have the same capacity.

Do not mix RDIMMS with LRDIMMs Do not mix RDIMMS with LRDIMMs

DIMM Speed 3200 MHz DIMMs will run at the lowest DIMMs will run at the lowest speed
speed of the CPU installed of the CPU installed

DIMM Type Do not mix DIMM types in a Do not mix DIMM types in a slot
channel
RDIMMs or LRDIMMs

Notes:
1. Although different DIMM capacities can exist in the same slot, this will result in less than optimal performance.
For optimal performance, all DIMMs in the same slot should be identical.

■ The DIMM/PMem guidelines are as follows:


— All DDR4 DIMMs populated in the DIMM slots must be the same size.
— PMem populated in the memory slots must all be the same size. PMem size mixing is
not allowed (for example, you cannot mix 512 GB and 128 GB PMem within the same
server).
— Both PMem operational modes (App Direct and Memory Mode) are compatible with
the B200 M6.
— Using non-Cisco supported hardware configurations may result in slower
performance or a non-supported warning during bootup.

Cisco UCS B200 M6 Blade Server 47


SUPPLEMENTAL MATERIAL

Memory Mirroring
When Memory Mirroring PID (N01-MMIRROR) is selected in STEP 3 CHOOSE MEMORY, page 13,
the DIMMS will be placed by the factory as shown in the Table 29.
■ Select 4, 6, 8, or 12 identical DIMMS per CPU.
■ If only 1 CPU is selected, please refer only to the CPU 1 DIMM placement columns in the
Table 29.
Table 29 Memory Mirroring

DIMM CPU 1 DIMM Placement in Channels  CPU 2 DIMM Placement in Channels 


Rank (for identical ranked DIMMS) (for identical ranked DIMMS)
4 (A1, B1); (D1, E1) (A1, B1); (D1, E1)

6 (A1, B1); (C1, D1); (E1, F1) (A1, B1); (C1, D1); (E1, F1)

8 (A1, B1); (D1, E1); (A2, B2); (D2, E2) (A1, B1); (D1, E1); (A2, B2); (D2, E2)
(A1, B1); (C1, D1); (E1, F1); (A2, B2); (C2, D2); (A1, B1); (C1, D1); (E1, F1); (A2, B2); (C2,
12
(E2, F2) D2); (E2, F2)
(A1, B1); (C1, D1); (E1, F1); (G1, H1); (A1, B1); (C1, D1); (E1, F1); (G1, H1);
16
(A2, B2); (C2, D2); (E2, F2), (G2, H2) (A2, B2); (C2, D2); (E2, F2), (G2, H2)

48 Cisco UCS B200 M6 Blade Server


SUPPLEMENTAL MATERIAL

Memory Support for 3rd Generation Intel® Xeon® Scalable Processors (Ice
Lake)

PMem Support
The Ice Lake CPUs support two memory modes:

■ App Direct Mode


■ Memory Mode

App Direct Mode


PMem operates as a solid-state disk storage device. Data is saved and is non-volatile. Both DCPMM and DIMM
capacities count towards the CPU capacity limit),

For example, if App Direct mode is configured and the DIMM sockets for a CPU are populated with 8 x 128
GB DRAMs (1 TB total DRAM) and 8 x 512 GB PMem (4 TB total PMem), then 5 TB total counts towards the
CPU capacity limit. Follow the Intel recommended DRAM:PMem ratio for App Direct Mode.

Memory Mode
PMem operates as a 100% memory module. Data is volatile and DRAM acts as a cache for PMem. Only the
PMem capacity counts towards the CPU capacity limit). This is the factory default mode.

For example, if Memory mode is configured and the DIMM sockets for a CPU are populated with 8 x 128 GB
DRAMs (1 TB total DRAM) and 8 x 512 GB PMem (4 TB total PMem), then only 4 TB total (the PMem memory)
counts towards the CPU capacity limit. All of the DRAM capacity (1 TB) is used as cache and does not factor
into CPU capacity. The recommended Intel DRAM:PMem ratio for Memory Mode is 1:4, 1:8, or 1:16.

For 3rd Generation Intel® Xeon® Scalable Processors (Ice Lake):

■ DRAMs and PMem are supported


■ Each CPU has 16 DIMM sockets and supports the following maximum memory capacities:
■ 2 TB using 16 x 128 GB DRAMs, or
■ 5 TB using 8 x 128 GB DRAMs and 8 x 512 GB TM Modules (PMem)

Only the following mixed DRAM/PMem memory configurations are supported per CPU socket:

■ 4 DRAMs and 4 PMem, or 8 DRAMs and 4 PMem, or 8 DRAMs and 1 PMem, or 8 DRAMs and 8 PMem

The available DRAM capacities are 16 GB, 32 GB, 64 GB, or 128 GB

The available PMem capacities are 128 GB, 256 GB, or 512 GB

For further details see the C220/C240/B200 M6 Memory Guide.

https://www.cisco.com/c/dam/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-s
ervers/memory-guide-c220-c240-b200-m6.pdf

Cisco UCS B200 M6 Blade Server 49


SPARE PARTS

SPARE PARTS
This section lists the upgrade and service-related parts for the UCS B200 M6 server. Some of these parts are
configured with every server or with every UCS 5108 blade server chassis.

Table 30 Spare Parts

Product ID (PID) PID Description

Local KVM I/O Cable

N20-BKVM= KVM local IO cable for UCS servers console port

CPUs

Note: If you are ordering a second CPU, see the CPU Accessories section in this table for additional parts
you may need to order for the second CPU.

8000 Series Processors

UCS-CPU-I8380=

UCS-CPU-I8368=

UCS-CPU-I8362=

UCS-CPU-I8360Y=

UCS-CPU-I8358P=

UCS-CPU-I8358=

UCS-CPU-I8352M=

UCS-CPU-I8352Y=

UCS-CPU-I8352V=

UCS-CPU-I8352S=

UCS-CPU-I8351N1=

6000 Series Processors

UCS-CPU-I6354=

UCS-CPU-I6348=

UCS-CPU-I6346=

UCS-CPU-I6342=

UCS-CPU-I6338N=

UCS-CPU-I6338T=

UCS-CPU-I6338=

50 Cisco UCS B200 M6 Blade Server


SPARE PARTS

Table 30 Spare Parts (continued)

Product ID (PID) PID Description

UCS-CPU-I6336Y=

UCS-CPU-I6334=

UCS-CPU-I6330N=

UCS-CPU-I6330=

UCS-CPU-I6326=

UCS-CPU-I6314U=2

UCS-CPU-I6312U3=

5000 Series Processors

UCS-CPU-I5320T=

UCS-CPU-I5320=

UCS-CPU-I5318N=

UCS-CPU-I5318S=

UCS-CPU-I5318Y=

UCS-CPU-I5317=

UCS-CPU-I5315Y=

4000 Series Processors

UCS-CPU-I4316=

UCS-CPU-I4314=

UCS-CPU-I4310T=

UCS-CPU-I4310=

UCS-CPU-I4309Y=

CPU Accessories

UCSB-HS-M6-F CPU Heat Sink for UCS B-Series M6 CPU socket (Front)

UCSB-HS-M6-R CPU Heat Sink for UCS B-Series M6 CPU socket (Rear)

UCS-CPU-TIM= Single CPU thermal interface material syringe for M6 server HS seal

UCSX-HSCK= UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)

UCS-CPUAT= CPU Assembly Tool for M6 Servers

UCS-M6-CPU-CAR= UCS M6 CPU Carrier

UCS-CPUATI-4= CPX-4 CPU Assembly tool for M6 Servers

Cisco UCS B200 M6 Blade Server 51


SPARE PARTS

Table 30 Spare Parts (continued)

Product ID (PID) PID Description

UCS-CPUATI-3= ICX CPU Assembly Tool for M6 Servers

Memory

UCS-MR-X16G1RW= 16 GB RDIMM SRx4 3200 (8Gb)

UCS-MR-X32G2RW= 32 GB RDIMM DRx4 3200 (8Gb)

UCS-MR-X32G1RW = 32GB RDIMM SRx4 3200 (16Gb)

UCS-MR-X64G2RW= 64 GB RDIMM DRx4 3200 (16Gb)

UCS-ML-128G4RW= 128 GB LRDIMM QRx4 3200 (16Gb)

UCS-MP-128GS-B0= Intel® OptaneTM Persistent Memory, 128GB, 3200-MHz

UCS-MP-256GS-B0= Intel® OptaneTM Persistent Memory, 256GB, 3200-MHz

UCS-MP-512GS-B0= Intel® OptaneTM Persistent Memory, 512GB, 3200-MHz

DIMM Blank

UCS-DIMM-BLK= Cisco UCS DIMM Blank

Rear Mezzanine Adapters

UCSB-MLOM-40G-04= Cisco UCS VIC 1440 modular LOM for blade servers

UCSB-ML-V5Q10G= Cisco UCS VIC 15411 modular LOM for Blade Servers

UCSB-MLOM-PT-01= Cisco UCS Port Expander Card for VIC

UCSB-VIC-M84-4P= Cisco UCS VIC 1480 mezzanine adapter

Front Mezzanine Adapters

UCSB-RAID12G-M6= Cisco FlexStorage 12G RAID controller with drive bays for two SAS/SATA
solid state drives (SSDs)

UCSB-LSTOR-PT-M6= Cisco FlexStorage pass-through module with drive bays for two PCIe
NVMe drives

UCSB-MSTOR-M6= Mini storage carrier that holds up to two SATA M.2 RAID cards

SATA SSD Drives

UCS-SD480GBI6-EP= 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD960GBI6-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD19TBI6-EP= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD480GBM6-EP= 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD960GBM6-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD19TM6-EP= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

52 Cisco UCS B200 M6 Blade Server


SPARE PARTS

Table 30 Spare Parts (continued)

Product ID (PID) PID Description

UCS-SD19TBM6-EP= 1.9TB Enterprise value SATA SSD (1X , SED)

UCS-SD960GM6-EP= 960GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD480GM6-EP= 480GB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD240GM6-EV= Micron 5300

UCS-SD480GI6-EV= Intel S4510

UCS-SD960GI6-EV= Intel S4510

UCS-SD16TM6-EV= Micron 5300

UCS-SD19TM6-EV= Micron 5300

UCS-SD38TM6-EV= Micron 5300

UCS-SD38TI6-EV= Intel S4510

UCS-SD76TM6-EV= Micron 5300

UCS-SD38TS6-EV= Samsung PM883

UCS-SD480GM6-EV= 480 GB 2.5 inch Enterprise Value 6G SATA SSD

UCS-SD960GM6-EV= 960 GB 2.5 inch Enterprise Value 6G SATA SSD

UCS-SD960GS26-EV= 960GB 2.5 inch Enterprise Value 6G SATA SSD

UCS-SD19TS26-EV= 1.9TB 2.5 inch Enterprise Value 6G SATA SSD

UCS-SD78TS26-EV= 7.6TB 2.5 inch Enterprise Value 6G SATA SSD

UCS-SDC960SA1V= 960GB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD

UCS-SDC1T9SA1V= 1.9TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD

UCS-SDC3T8SA1V= 3.8TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD

UCS-SDC7T6SA1V= 7.6TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD

NVME SSD Drives

UCSB-NVMEM6-M7600= 7.6TB 2.5in U.3 7mm Micron 7450 Hg Perf Med End NVMe (1X)

SED Drives

UCS-SD19TM6NK9= 1.9TB 2.5in Enterprise performance 6GSATA SSD(3X endurance)

UCS-SD38TM6NK9= 3.8TB Enterprise Value SATA SSD (1X, SED)

UCS-SD76TM6NK9= 7.6TB Enterprise Value SATA SSD (1X, SED)

UCS-SD960GM6NK9= 960GB Enterprise Value SATA SSD (1X , SED)

SATA M.2 Storage Modules

Cisco UCS B200 M6 Blade Server 53


SPARE PARTS

Table 30 Spare Parts (continued)

Product ID (PID) PID Description

UCS-M2-240G= 240GB SATA M.2

UCS-M2-480G= 480GB M.2 SATA SSD

UCS-M2-960G= 960GB SATA M.2

UCS-M2-192TB= 1.9TB SATA M.2

UCS-M2-I240GB= 240GB M.2 Boot SATA Intel SSD

UCS-M2-I480GB= 480GB M.2 Boot SATA Intel SSD

Note: If you order M.2 SATA drives, you must select the boot-optimized RAID controller.

Boot-Optimized RAID Controller

UCS-M2-HWRAID Cisco Boot optimized M.2 RAID controller

Drive Blank

UCSB-FBLK-M6= Cisco B200 M6 7mm Front Drive Blank

TPM

UCSX-TPM-002C= Trusted Platform Module for Whitley Provisioning

UCS-TPM-002D= TPM 2.0 TCG FIPS140-2 CC+ Cert M6 Intel MSW2022 Compliant

UCSX-TPM-OPT-OUT= OPT OUT, TPM 2.0, TCG, FIPS140-2, CC EAL4+ Certified

Software/Firmware

Windows Server Recovery Media

MSWS-19-ST16C-RM= Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-19-DC16C-RM= Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only

MSWS-22-ST16C-RM= Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-22-DC16C-RM= Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only

RHEL SAP

RHEL-SAPSP-3S= RHEL SAP Solutions Premium - 3 Years

RHEL-SAPSS-3S= RHEL SAP Solutions Standard - 3 Years

RHEL-SAPSP-R-1S= Renew RHEL SAP Solutions Premium - 1 Year

RHEL-SAPSS-R-1S= Renew RHEL SAP Solutions Standard - 1 Year

RHEL-SAPSP-R-3S= Renew RHEL SAP Solutions Premium - 3 Years

RHEL-SAPSS-R-3S= Renew RHEL SAP Solutions Standard -3 Years

54 Cisco UCS B200 M6 Blade Server


SPARE PARTS

Notes:
1. The maximum number of UCS-CPU-I8351N CPUs is one
2. The maximum number of UCS-CPU-I6314U CPUs is one
3. The maximum number of UCS-CPU-I6312U CPUs is one

Please refer to the UCS B200 M6 Installation Guide for installation procedures.

Cisco UCS B200 M6 Blade Server 55


UPGRADING or REPLACING CPUs

UPGRADING or REPLACING CPUs

NOTE: Before servicing any CPU, do the following:


■ Decommission and power off the server.
■ Slide the B200 M6 out from its chassis.
■ Remove the top cover.

To replace an existing CPU, follow these steps:

(1) Have the following tools and materials available for the procedure:

■ T-30 Torx driver—Supplied with replacement CPU.


■ #1 flat-head screwdriver—Supplied with replacement CPU.
■ CPU assembly tool—Supplied with replacement CPU. Can be ordered separately as Cisco PID
UCS-CPUAT=.
■ Heatsink cleaning kit—Supplied with replacement CPU. Can be ordered separately as Cisco
PID UCSX-HSCK=.
■ Thermal interface material (TIM)—Syringe supplied with replacement CPU. Can be ordered
separately as Cisco PID UCS-CPU-TIM=.

(2) Order the appropriate replacement CPU from Available CPUs on page 9.

(3) Carefully remove and replace the CPU and heatsink in accordance with the instructions
found in “Cisco UCS B200 M6 Blade Server Installation and Service Note,” found at:

https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B20
0M6.html

To add a new CPU, follow these steps:

(1) Have the following tools and materials available for the procedure:

■ T-30 Torx driver—Supplied with new CPU.


■ #1 flat-head screwdriver—Supplied with new CPU
■ CPU assembly tool—Supplied with new CPU.Can be ordered separately as Cisco PID
UCS-CPUAT=
■ Thermal interface material (TIM)—Syringe supplied with replacement CPU.Can be ordered
separately as Cisco PID UCS-CPU-TIM=

(2) Order the appropriate new CPU from Table 3 on page 9.

(3) Order one heat sink for each new CPU. Order PID UCSB-HS-M6-F= for the front CPU socket
and PID UCSB-HS-M6-R= for the rear CPU socket.

56 Cisco UCS B200 M6 Blade Server


UPGRADING or REPLACING MEMORY

(4) Carefully install the CPU and heatsink in accordance with the instructions found in “Cisco
UCS B200 M6 Blade Server Installation and Service Note,” found at:
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M6
.html.

UPGRADING or REPLACING MEMORY


NOTE: Before servicing any DIMM or PMem, do the following:
■ Decommission and power off the server.
■ Remove the top cover from the server
■ Slide the server out the front of the chassis.

To add or replace DIMMs or PMem, follow these steps:

Step 1 Open both DIMM connector latches.

Step 2 Press evenly on both ends of the DIMM until it clicks into place in its slot

Note: Ensure that the notch in the DIMM aligns with the slot. If the notch is misaligned, it is
possible to damage the DIMM, the slot, or both.

Step 3 Press the DIMM connector latches inward slightly to seat them fully.

Step 4 Populate all slots with a DIMM or DIMM blank. A slot cannot be empty.

Figure 5 Replacing Memory


2

1
3
2

4
1
306040

Cisco UCS B200 M6 Blade Server 57


UPGRADING or REPLACING MEMORY

CAUTION: The DIMMs installed in sockets with yellow latches are rotated
180 degrees with respect to the DIMMs/PMem in the sockets with white
latches. Make sure to align the notch keys in DIMMs/PMem with the keys in
the sockets before inserting to avoid damage to DIMMs/PMem.

For additional details on replacing or upgrading DIMMs, see “Cisco UCS B200 M6 Blade Server
Installation and Service Note,” found at
https://www.cisco.com/content/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B20
0M6.html

58 Cisco UCS B200 M6 Blade Server


DISCONTINUED EOL PRODUCTS

DISCONTINUED EOL PRODUCTS


Below is the list of parts were previously available for this product and are no longer sold. Please refer to
the EOL Bulletin Links via the Table 36 below to determine if still supported.

Table 31 EOS
Product ID Description EOL/EOS link
Operating system
SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 1-Yr Support Req
SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 1-Yr SnS
SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 3-Yr Support Req
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 3-Yr SnS
SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); 5-Yr Support Req
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2
CPU,Unl VM); Prio 5-Yr SnS
SLES-SAP-2SUV-1A SLES for SAP Apps w/ HA (1-2 CPU,
Unl VM); 1-Yr Support Reqd
SLES-SAP-2SUV-1S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 1-Yr SnS
SLES-SAP-2SUV-3A SLES for SAP Apps w/ HA (1-2 CPU,
Unl VM); 3-Yr Support Reqd
SLES-SAP-2SUV-3S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 3-Yr SnS
SLES-SAP-2SUV-5A SLES for SAP Apps w/ HA (1-2 CPU,
Unl VM); 5-Yr Support Reqd
SLES-SAP-2SUV-5S SLES for SAP Apps (1-2 CPU, Unl
VM); Priority 5-Yr SnS
Drives
UCS-SD76TBM6NK9 7.6TB Enterprise Value SATA SSD https://www.cisco.com/c/en/us/products/coll
(1X, SED) ateral/servers-unified-computing/ucs-c-series-r
ack-servers/unified-computing-accessories-eol.
html
UCS-SD78TS6-EV 7.6TB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/coll
SATA SSD ateral/servers-unified-computing/ucs-c-series-r
ack-servers/unified-computing-accessories-eol.
html
UCS-SD960GBM6NK9 960GB Enterprise Value SATA SSD https://www.cisco.com/c/en/us/products/coll
(1X , SED) ateral/servers-unified-computing/ucs-c-series-r
ack-servers/unified-computing-accessories-eol.
html
UCS-M2-240GB 240GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/coll
ateral/servers-unified-computing/ucs-c-series-r
ack-servers/unified-computing-accessories-eol.
html

Cisco UCS B200 M6 Blade Server 59


DISCONTINUED EOL PRODUCTS

Table 31 EOS
UCS-M2-960GB 960GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/coll
ateral/servers-unified-computing/ucs-c-series-r
ack-servers/unified-computing-accessories-eol.
html
UCS-SD960GS6-EV 960GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/coll
SATA SSD ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hyperflex-accessories-eo
l2.html
UCSB-NVMEM6-W1920 1.9TB 2.5in U.2 WD SN640 NVMe https://www.cisco.com/c/en/us/products/coll
Med Perf. Value Endurance ateral/servers-unified-computing/ucs-b-series-b
lade-servers/select-ucs-accessories-eol.html
UCS-SD19TS6-EV 1.9TB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/coll
SATA SSD ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hyperflex-accessories-eo
l2.html
UCS-SD38TBM6NK9 3.8TB Enterprise Value SATA SSD https://www.cisco.com/c/en/us/products/coll
(1X, SED) ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-accessories-eol15371.ht
ml
UCSB-NVMEM6-W1920 1.9TB 2.5in U.2 WD SN640 NVMe https://www.cisco.com/c/en/us/products/coll
Med Perf. Value Endurance ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-accessories-eol15371.ht
ml
UCS-SD120GM6-EV 120 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/coll
SATA SSD ateral/servers-unified-computing/ucs-b-series-b
lade-servers/select-ucs-accessories-eol.html
UCS-SD38TS26-EV 3.8TB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/coll
SATA SSD ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hci-accessories-eol.html
UCSB-NVMEM6-W3800 3.8TB 2.5in U.2 WD SN640 NVMe https://www.cisco.com/c/en/us/products/coll
Med Perf. Value Endurance ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hci-accessories-eol.html
UCSB-NVMEM6-W6400 6.4TB 2.5in U.2 WD SN640 NVMe https://www.cisco.com/c/en/us/products/coll
Med Perf. High Endurance ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hci-accessories-eol.html
UCSB-NVMEM6-W800 800GB 2.5in U.2 WD SN640 NVMe https://www.cisco.com/c/en/us/products/coll
Med Perf. High Endurance ateral/servers-unified-computing/ucs-c-series-r
ack-servers/select-ucs-hci-accessories-eol.html

60 Cisco UCS B200 M6 Blade Server


TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Dimensions and Weight

Table 32 UCS B200 M6 Dimensions and Weight

Parameter Value

Height 1.95 in. (50 mm)

Width 8.35 in.(212 mm)

Depth 24.4 in. (620 mm)

Weight ■ Base server weight = 10.0 lbs (4.54 kg)


(no HDDs, no CPUs, no DIMMs, no mezzanine adapters or memory)
■ Minimally configured server weight = 10.08 lbs (4.57 kg)
(no HDDs, 2 CPUs, 2 DIMMs, VIC 1440 but no additional mezzanine adapter
■ Fully configured server weight = 18.14 lbs (8.23 kg)
(2 HDDs, 2 CPUs, 32 DIMMs, VIC 1440 and additional mezzanine adapter both populated)

Power Specifications
For configuration-specific power specifications, use the Cisco UCS Power Calculator at:

http://ucspowercalc.cisco.com

NOTE: The B200 M6 has a power cap of 960 Watts for all combinations of
components (CPUs, DIMMs, drives, and so on).

Cisco UCS B200 M6 Blade Server 61