24011 series, 3/2

Direct solenoid actuated poppet valve

>> Port size: 1/4” (ISO G or >> Add-on manual over-


NPT), NAMUR Interface ride or inductive limit
>> Main application: switches on request
Single and double >> Suited for outdoor use
acting actuators under critical
>> TÜV-approval based environment
on type examination conditions.
DGRL 97/23/EC and >> Variable valve solenoid
IEC 61508, multichannel combination
up to SIL 3 (12 years)

Technical features
Medium: Flow: Ambient/Media temperature: Materials:
Compressed air, filtered, non- Gaseous fluids: 340 l/min NBR: Body: Aluminium anodized
lubricated and dry. Other gase and Liquid fluids: Cv 0,34 -25 ... +80°C (-13 ... +176°F) (suitable for high humidity,
liquid fluids on request. (Viscosity for Port size: FPM: sulphuric, sodium chloride or
gaseous or liquid fluids up to G1/4, 1/4 NPT -10...+120°C (+14 ... +248°F) ammonia environments),
40 mm2/s) NAMUR Interface with integrated Water +95°C (+203°F) brass 2.0401 (Ms 58) or
Operation: recirculation from the exhaust air to VMQ: stainless steel 1.4404 (316 L)
Direct solenoid operated the acutator sping chamber -40... +60°C (-40 ... +140°F) Seal: FPM, NBR, VMQ
poppet valve Flow direction: Depending on solenoid system Inner parts: stainless steel, brass
Operating pressure: Optional Air supply must be dry enough
0 ... 10 bar (0 ... 145 psi) Mounting position: to avoid ice formation at Flow conversion:
Orifice: Any, but preferably with temperatures below +2°C (35°F). Cv US Gallon/min (water) =
5 mm solenoid vertical For outdoor installations must be l/min (air) x 0,001
protected all connections against Kv m³/h (water) =
the penetration of moisture and l/min (air) x 0,000906
a solenoid with IP66 protection
must be used!

Technical data
Housing: Brass
Symbol Port Orifice Operating pressure Material Manual Test certificate Weight Drawing Solenoid Model
size (mm) (bar) (psi) Seat seal override IEC 61508 97/23/EC (kg) No. group *1)
G1/4 5 0 ... 10 0 .. 145 NBR Not possible X — 0,65 1 A+B 2401103
G1/4 5 0 ... 10 0 .. 145 NBR Push only X — 0,70 1 A+B 2401107
G1/4 5 0 ... 10 0 .. 145 NBR Turn and lock — — 0,70 1 A+B 2401119
G1/4 5 0 ... 10 0 .. 145 NBR Not possible X X 0,65 1 A+B 2401149
G1/4 5 0 ... 10 0 .. 145 FPM Not possible X — 0,65 1 A+B 2401126
G1/4 5 0 ... 10 0 .. 145 VQM Not possible X — 0,65 1 A+B 2401153
2
G1/4 5 0 ... 10 0 .. 145 VQM Semi automatic X — 0,70 1 A+B 2401154
1/4 NPT 5 0 ... 10 0 .. 145 NBR Not possible X X 0,65 1 A+B 2401138
1 3
1/4 NPT 5 0 ... 10 0 .. 145 NBR Push only X — 0,70 1 A+B 2401148
1/4 NPT 5 0 ... 10 0 .. 145 NBR Turn and lock — — 0,70 1 A+B 2401136
1/4 NPT 5 0 ... 10 0 .. 145 NBR Semi automatic X — 0,70 1 A+B 2401140
1/4 NPT 5 0 ... 10 0 .. 145 FPM Not possible X — 0,65 1 A+B 2401131
1/4 NPT 5 0 ... 10 0 .. 145 VQM Not possible X — 0,65 1 A+B 2401106
1/4 NPT 5 0 ... 10 0 .. 145 VQM Push only X — 0,70 1 A+B 1025226
*1) When ordering please indicate solenoid, voltage and current type (frequency).
• Particulary for valves with TÜV approval and attachment in plants based on safety standard IEC 61511, taking into account to the operating and maintance instructions
document 7503444.

Our policy is one of continued research and development. We therefore reserve the right to amend, 2/15
without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.01
24011 series, 3/2
Direct solenoid actuated poppet valve

Housing: Stainless steel


Symbol Port size Orifice Operating Material Manual Test certificate Weight Drawing Solenoid Model *1)
(mm) pressure Seat seal override IEC 61508 97/23/EC (kg) No. group
(bar)
G1/4 5 0 ... 10 NBR Not possible X X 0,65 2 A+B 2401186
1/4 NPT 5 0 ... 10 NBR Not possible X X 0,65 2 A+B 2401112
1/4 NPT 5 0 ... 10 FPM Semi automatic — — 0,70 2 A+B 2401146
1/4 NPT 5 0 ... 10 FPM Not possible — — 0,65 2 A+B 1025227
2
G1/4 5 0 ... 10 FPM Not possible — — 0,70 2 A 2401127 *2)
G1/4 5 0 ... 10 FPM Push only — — 0,70 2 A 2401170 *2)
1 3
G1/4 5 0 ... 10 FPM Turn and lock — — 0,70 2 A 2401139 *2)
G1/4 5 0 ... 10 VMQ Not possible — X 0,65 2 A 2401155 *2)
1/4 NPT 5 0 ... 10 FPM Not possible — — 0,65 2 A 2401147 *2)
1/4 NPT 5 0 ... 10 VMQ Not possible — X 0,65 2 A 2401168 *2)
3 2 NAMUR G1/4 5 0 ... 10 NBR Without X — 1,00 2 A+B 2401196
NAMUR G1/4 5 0 ... 10 VQM Without — — 1,00 2 A 2401142
12

3 1 2

3 2 NAMUR G1/4 5 0 ... 10 NBR Without X X 1,00 3 A+B 1025212 *3)


NAMUR 1/4 NPT 5 0 ... 10 NBR Without X X 1,00 3 A+B 1025328 *3)
12

3 11 2

Housing: Aluminium anodized


Symbol Port size Orifice Operating Material Manual over- Test certificate Weight Drawing Solenoid Model *1)
(mm) pressure Seat seal ride IEC 61508 97/23/EC (kg) No. group
(bar)
3 2 NAMUR G1/4 5 0 ... 10 NBR Without X X 0,55 3 A+B 2401191
NAMUR G1/4 5 0 ... 10 NBR Without X X 0,55 3 A+B 2401116 *4)
12
NAMUR G1/4 5 0 ... 10 NBR Without — — 0,70 5 A+B 1025333 *5)
NAMUR 1/4 NPT 5 0 ... 10 NBR Without X X 0,55 3 A+B 1025254
3 1 2 NAMUR G1/4 5 0 ... 10 VQM Without X — 0,55 3 A+B 2401133
3 2 NAMUR G1/4 5 0 ... 10 NBR Without X X 0,55 4 A+B 2401109 *3)

12

3 11 2

*1) When ordering please indicate solenoid, voltage and current type (frequency).
*2) Complete stainless steel version
*3) Port P in flange according to VDI/VDE 3845 for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300)
*4) Free of non-ferrous metals
*5) Proximity switch
• Particulary for valves with TÜV approval and attachment in plants based on safety standard IEC 61511, taking into account to the operating and maintance instructions
document 7503444.

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.4.306.02 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
24011 series, 3/2
Direct solenoid actuated poppet valve

Solenoids group A, standard voltages


Power Rated current Protection Ex-Protection Temperature Electrical Weight Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
24 V d.c. 230 V a.c. 24 V d.c. 230 V a.c. IP/NEMA Media
(W) (VA) (m A) (m A) (°C) (kg) No. No.
16,9 — 703 — IP65 (with — -25 ... +60 Connector 0,26 3 1 0800
connector) Media: +80 max DIN EN
175301-803,
Form A *1)
— 17,3 — 75 IP65 (with — -25 ... +60 Connector 0,35 4 6 3803
connector) Media: +80 max DIN EN
175301-803,
Form A *1)
8,9 — 369 — IP65 — -30...+90 Terminals, cable 0,5 9 2 4120
Media: +110 gland
Pg 13,5
— 10 — 43 IP65 — -30...+90 Terminals, cable 0,5 9 6 4121
Media: +110 gland
Pg 13,5
8,9 — 369 — IP67 — -30...+90 3 m cable, 0,7 9 2 4122
Media: +110 encapsulated in
EP resin
— 10 — 43 IP67 — -30...+90 3 m cable, 0,7 9 6 4123
Media: +110 encapsulated in
EP resin
8,9 — 369 — IP66 (with II 2 G Ex e mb IIC T4/ T4: -40 ... +65 M20 x 1,5 *1) 0,5 6 4 4270
cable gland) T5 Gb T5: -40 ... +55
II 2 D Ex tb IIIC -40 ... +65
T130°C Db IP66
— 10,0 — 43 IP66 (with II 2 G Ex e mb IIC T4/ T4: -40 ... +65 M20 x 1,5 *1) 0,5 6 7 4271
cable gland) T5 Gb T5: -40 ... +55
II 2 D Ex tb IIIC -40 ... +65
T130°C Db IP66
8,9 — 369 — IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ... +70 1/2 NPT *1) 0,8 7 20 4670
cable gland) T6 Gb T6: -40 ... +40
II 2 G Ex e mb IIC T4/
T6 Gb
II 2 D Ex tb IIIC -40 ... +70
T130°C Db
— 10,0 — 43 IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ... +70 1/2 NPT *1) 0,8 7 21 4671
cable gland) T6 Gb T6: -40 ... +40
II 2 G Ex e mb IIC T4/
T6 Gb
II 2 D Ex tb IIIC -40 ... +70
T130°C Db
8,9 — 369 — IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ... +70 M20 x 1,5 *1) 0,8 7 20 4672
cable gland) T6 Gb T6: -40 ... +40
II 2 G Ex e mb IIC T4/
T6 Gb
II 2 D Ex tb IIIC -40 ... +70
T130°C Db
— 10,0 — 43 IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ... +70 M20 x 1,5 *1) 0,8 7 21 4673
cable gland) T6 Gb T6: -40 ... +40
II 2 G Ex e mb IIC T4/
T6 Gb
II 2 D Ex tb IIIC -40 ... +70
T130°C Db
8,9 — 369 — IP66 (with II 2 G Ex mb d IIC T4: -40 ... +50 M20 x 1,5 *1) 1,2 10 4 4872
cable gland) T4/T6 T6: -40 ... +40
II 2 G Ex mb e II T4/T6
— 10 — 43 IP66 (with II 2 G Ex mb d IIC T4: -40 ... +50 M20 x 1,5 *1) 1,2 10 7 4873
cable gland) T4/T6 T6: -40 ... +40
II 2 G Ex mb e II T4/T6
13,6 — 567 — NEMA 4, 4X, XP/DIP, Div. 1 & 2 -20 ... +60 Flying leads 0,5 8 1 3826
6, 6P, 7, 9 CI. I, Gr. A-D 450 mm
CI. II/III, Gr. E-G
T3 (160°C)
— 15,7 — 68 NEMA 4, 4X, XP/DIP, Div. 1 & 2 -20 ... +60 Flying leads 0,5 8 5 3827
6, 6P, 7, 9 CI. I, Gr. A-D 450 mm
CI. II/III, Gr. E-G
T3 (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories«
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of
protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of protection is used, the solenoid will have protection class Ex e mb.

Approvals Approvals
Model Approvals Datasheet Model Approvals Datasheet
ATEX IECEx FM ATEX IECEx
382x — — CSA-LR 57643-6 N/en 7.1.575 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X N/en 7.1.585
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — N/en 7.1.580 48xx PTB 06 ATEX 2054 X IECEx PTB 07.0039X N/en 7.1.590

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/15 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.03
24011 series, 3/2
Direct solenoid actuated poppet valve

Solenoids group B, standard voltages


Power Rated current Protection Ex-Protection Temperature Electrical Weight Drawing Circuit Model
consumption class (ATEX-Category) Ambient/ connection diagram
24 V d.c. 230 V a.c. 24 V d.c. 230 V a.c. IP/NEMA Media
(W) (VA) (m A) (m A) (°C) (kg) No. No.
6,8 — 284 — IP65 (with — -25 ... +60 Connector 0,33 2 1 0827
connector) DIN EN
175301-803,
form A *1)
— 10,6 — 46 IP65 (with — -25 ... +60 Connector 0,34 3 6 3805
connector) DIN EN
175301-803,
form A *1)
3,9 — 162 — IP65 — -30...+100 Terminals, cable 0,5 9 2 4140
Media: +110 gland
Pg 13,5
— 5,3 — 23 IP65 — -30...+100 Terminals, cable 0,5 9 6 4141
Media: +110 gland
Pg 13,5
3,9 — 162 — IP67 — -30...+100 3 m cable, 0,7 9 2 4142
Media: +110 encapsulated in
EP resin
— 5,3 — 23 IP67 — -30...+100 3 m cable, 0,7 9 6 4143
Media: +110 encapsulated in
EP resin
3,9 — 162 — IP66 (with II 2 G Ex e mb IIC T4/ T4: -40 ...+80 M20 x 1,5 *1) 0,6 6 4 4260
cable gland) T6 Gb T6: -40 ... +55
II 2 D Ex tb IIIC -40 ...+80
T130°C Db IP66
— 5,3 — 23 IP66 (with II 2 G Ex e mb IIC T4/ T4: -40 ...+80 M20 x 1,5 *1) 0,6 6 7 4261
cable gland) T6 Gb T6: -40 ... +55
II 2 D Ex tb IIIC -40 ...+80
T130°C Db IP66
3,9 — 162 — IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ...+80 1/2 NPT *1) 0,8 7 20 4660
cable gland) T6 Gb T6: -40 ... +55
II 2 G Ex e mb IIC T4/ -40 ...+80
T6 Gb
II 2 D Ex tb IIIC
T130°C Db
— 5,3 — 23 IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ...+80 1/2 NPT *1) 0,8 7 21 4661
cable gland) T6 Gb T6: -40 ... +55
II 2 G Ex e mb IIC T4/ -40 ...+80
T6 Gb
II 2 D Ex tb IIIC
T130°C Db
3,9 — 162 — IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ...+80 M20 x 1,5 *1) 0,8 7 20 4662
cable gland) T6 Gb T6: -40 ... +55
II 2 G Ex e mb IIC T4/ -40 ...+80
T6 Gb
II 2 D Ex tb IIIC
T130°C Db
— 5,3 — 23 IP66 (with II 2 G Ex d mb IIC T4/ T4: -40 ...+80 M20 x 1,5 *1) 0,8 7 21 4663
cable gland) T6 Gb T6: -40 ... +55
II 2 G Ex e mb IIC T4/ -40 ...+80
T6 Gb
II 2 D Ex tb IIIC
T130°C Db
8,9 — 369 — NEMA 4, 4X, XP/DIP, Div. 1 & 2 -20 ... +60 Flying leads 0,5 8 1 3824
6, 6P, 7, 9 CI. I, Gr. A-D 450 mm
CI. II/III, Gr. E-G
T3 (160°C)
— 9,5 — 41 NEMA 4, 4X, XP/DIP, Div. 1 & 2 -20 ... +60 Flying leads 0,5 8 5 3825
6, 6P, 7, 9 CI. I, Gr. A-D 450 mm
CI. II/III, Gr. E-G
T3 (160°C)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.
*1) Connector/cable gland is not scope of delivery, see table »Accessories«
Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland.
Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with
Ex e type of protection is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals Datasheet
ATEX IECEx FM
372x, 382x — — CSA-LR 57643-6 N/en 7.1.575
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — N/en 7.1.580
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — N/en 7.1.585

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.4.306.04 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
24011 series, 3/2
Direct solenoid actuated poppet valve

Accessories
Electrical connection
Cable gland
Protection class
Ex e, Ex d

Page 9
Thread Cable Ø (mm) Materials Protection class (ATEX) Model
M20 x 1,5 5 ... 8 Nickel plated brass II 2 GD Ex e 0588819
M20 x 1,5 10 ... 14 Nickel plated brass II 2 GD Ex d 0588851
1/2 NPT 7,5 ... 11,9 Nickel plated brass II 2 GD Ex d 0588925
M20 x 1,5 9 ... 13 Stainless steel 1.4571 (316 Ti) II 2 GD Ex e 0589385
M20 x 1,5 7 ... 12 Stainless steel 1.4404 (316 L) II 2 GD Ex d 0589395
M20 x 1,5 10 ... 14 Stainless steel 1.4404 (316 L) II 2 GD Ex d 0589387
M20 x 1,5 5 ... 9 Plastic (PA) — 0110854
M20 x 1,5 6 ... 12 Plastic (PA) — 0110855

Accessories
Connector for proximity switch Connector
4-pin, 90° 4-pin, 90° 4-pin, straight 4-pin, straight DIN EN 175301-803

Page 12 Page 12 Page 12 Page 12 0570275 (form A)


0523058 0523056 0523057 0523055 (wi hout cable)
(2 m cable,4-core) (without cable) (2 m cable, 4-core)
0523053 0523052
(5 m cable,4-core) (5 m cable, 4-core)

Silencer *1) Exhaust guard *2) Filter Add-on manual override *3)
Without detent with detent

Page 10 Page 10 Page 10 Page 7 Page 7


C/S2 (1/8 NPT) 0613422 (G1/4, 1/4 NPT) 0681173 (G1/4, 1/4 NPT) 0600205 0601765
M/S2 (G1/8)
*1) For indoors use
*2) For outdoors use, opening pressure ~ 0,2 bar
*3) Add on for NAMUR valves always possible, Inline on request
Using the manual override with detent cancels the SIL-Approval!

Manual Override
The manual override is meant to be used for system testing. Upon de-energisation of the coil the valve returns to
rest position by mechanical spring force (for testing only prior to commissioning).

Semi automatic/Manual reset


Function: The valve does not switch after energisation of the coil. It will only operate if the reset button is being
pushed. The valve will then, by means of the coil voltage, be held in its switching position even if the reset button
is being released. It will return to rest position when the coil is being de-energised. Allowable voltage tolerance:
+/- 10%.

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/15 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.05
24011 series, 3/2
Direct solenoid actuated poppet valve

NAMUR accessories
Throttle control Flange plate Yoke Distance plate for Mounting plate Quick exhaust module *2)
plate *1) pressure switches

Page 11 Page 10 & 11 Page 11 Page 11 Page 11


4040239 0612790 (NAMUR single connection plate) 0540593 0540109 0613453 (90°) 4050218
0612791 (NAMUR-rip use in combination wi h 0612790) 0612631 (180°)
0613556 (270°)
*1) The throttle control plate 4040239 has a minimum flow rate for safety reason.
*2) Technical details see catalogue page en 5.4.820.

Drawings Dimensions in mm
Projection/First angle
Valves
1 2

43 43

50
50
~ 98

~ 98

1 1
2 2
51

51
35,5

35,5
12

12
3 3
12,5

12,5
12

12
2
5,5 30,5
5,5
30 2
27 4 27 4
55
55

3
50
50
M5

~ 113

3
13,5

3
15

G1/4
G1/4
19

37,5
12

1
24

52

2
ø 19,5
ø 15,5
G1/4

2
26,5

19
3 5,5

7,5 4 22,5 6,5 16


4,5

22 6,5 32 17
4 50

2 Port size G1/4 or 1/4 NPT


3 3 mm deep
4 Retrofit option for manual override

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.4.306.06 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
24011 series, 3/2
Direct solenoid actuated poppet valve

Dimensions in mm
50
4 Projection/First angle

50
M5

~ 113

13,5
3

15

G1/4
G1/4
19

37,5
12
1

24

52

ø 19,5
ø 15,5
ø 10
M6
26,5

5,5
2
3
4 6,5
1,5 22,5 16
4,5

7,5 22 6,5 32 17
4 50

2 Port size G1/4 or 1/4 NPT


3 3 mm deep
4 Retrofit option for manual override

Add-on manual override


Without detent With detent
Model: 0600205 Model: 0601765

Please note: add-on manual override for NAMUR valves provided only for
4,5

commissioning and tests


9,5

19 19
8,5

ø12 36

50
5
50
~ 108,5
M5

3
13,5

3
15

G1/4
G1/4
19

37,5
12

1
24

52

2
ø 19,5
ø 15,5
G1/4

2
26,5

19
3 5,5

6,5
28

19

4 17
~ 54

10
7,5 4 22,5 16
6 3 3 mm deep
22 6,5 32 17
4 Proximity switch
50
6 Thread M12 x 1

Proximity switch
Technical features
Supply voltage (Ub): Protection class:
1 Rv
7,7 ... 9 V d.c. IP68 + 4 3
Ripple: Pressure-resistant:
15% 500 bar (7251 psi) pnp 1 2
Frequency of operating cycles: Ambient temperature: 3
1000 Hz -25 ... +70°C (-13 ... +158°F)

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/15 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.07
24011 series, 3/2
Direct solenoid actuated poppet valve

Solenoids Dimensions in mm
Projection/First angle
3 4
86,5 96,5
53,5 5 63,5
1
49 1 59

17

22
40,5
40,5

43

48
M16 x 1,5 12
M16 x 1,5 12

34

28
43
43

28
34

27 27

6 7
2 70,5 2
107
40,5

41,5
64,5

53
27

20
10 ± 0,2

14,5 + 1

3 3 59
42
54,5

56

29 43
122

8
2 9
1/2 NPT 2

5
40,5

42

18,5

84
63 2
61
33,5
43

30,5
26 4
110

1 Connector can be indexed by 4x90°


2 Ø 16 or 13 (with spacer tube)
3 M20 x 1,5 or 1/2 NPT
4 Flying leads AWG 18 (450 mm long)
5 With cable gland, Pg 13,5

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.4.306.08 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
24011 series, 3/2
Direct solenoid actuated poppet valve

10

68 2

41

45
43

53
15 + 1

3
2 Ø 16
3 M20 x 1,5
56

28 35
113

Circuit diagrams
1 2 4 5

6 7 20 21

T T

Cable gland

C C A B C øD Model
B D B D M20 x 1,5 9 36 5 ... 8 22 0588819
M20 x 1,5 6,5 27,5 9 ... 13 22 0589385
M20 x 1,5 14 39 10 ... 14 24 0588851
A

1/2 NPT 15 58 7,5 ... 11,9 24 0588925


M20 x 1,5 14 39 7 ... 12 24 0589395
0588925 only M20 x 1,5 10 34 10 ... 14 24 0589387
M20 x 1,5 9 36 5 ... 9 24 0110854
M20 x 1,5 9 36 6 ... 12 24 0110855

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/15 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.09
24011 series, 3/2
Direct solenoid actuated poppet valve

NAMUR hole pattern (driving side)

32
M5 3

24

1 3
2
1 Port 2 (A)
2 Coding stud threaded
3 M5 (10 deep)
4 4 Port 3 (R)

Dimensions in mm
Projection/First angle

Accessories
Silencer Exhaust guard Filter
Model: M/S2, C/S2 Model: 0613422 Model: 0681173
4
3
42,5 26,5

1,5
8 10

Ø 10,5

13
8,5
60°
ø 15,5

1/4”

1/4”
ø 21

5
60°

Thread pitch diameter max. 11,85 mm

Single connection plate


Model: 0612790
19 25,5 M5 (4x)
19

25,5
G1/4

35
19

41

16
60

11,5
30

16

12 12
34,5
104

ø 9,5 19
ø 5,5 G1/4
29

19
12
10

ø9 27 21
ø 14,5

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.4.306.10 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
24011 series, 3/2
Direct solenoid actuated poppet valve

NAMUR slot Yoke Throttle control plate Dimensions in mm


Projection/First angle
Model: 0612791 Model: 0540593 Model: 4040239
19,5
15,5
2x
65
51
9,5

45
32
M5
5,5 50 12

41
41 12

76 4
5,5
5 20
12

8
12

25
5

11

60° M5

7,5
B B

15,5
15,5
A A

Distance plate for Mounting plate


pressure switches Model: 0613453 (90°) Model: 0612631 (180°) Model: 0613556 (270°)
Model: 0540109 32 32
16 9 16 9

3
12

3 3 3
12
12

12
24

24

12
26
24

24
37
37

2 1 2 2
12

1 2
58
20

20

20
20

7
7

M5 1 M5 M5 M5

45 24 20 45 24 9
17 12 32 12
32

1 12
2 2
16

37

2 3
16
37

50

24
32
55
24

32
55
43,5
50

43,5

3 2
3 3
12 1
55 55

Our policy is one of continued research and development. We therefore reserve the right to amend,
2/15 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH en 5.4.306.11
24011 series, 3/2
Direct solenoid actuated poppet valve

Connector Dimensions in mm
Projection/First angle
90°, 4 pin, with PUR cable 90°, 4 pin, without cable

45° 45°

B
B

~C ~C
E

ø D1
~F

~F
B
øD
øD

B C øD øD1 F Wire x Cable length Weight Model B C øD E F Weight Model


dim. (m) (g) (g)
M12 x 1,5 32,5 15 11 27 4 x 0,34 mm2 2 90 0523058 M12 x 1,5 40,5 20 Pg 7 35 30 0523056
M12 x 1,5 32,5 15 11 27 4 x 0,34 mm2 5 180 0523053

Straight, 4 pin, with PUR cable Straight, 4 pin, without cable

E
ø D1
øD

øD

B
~C
~C

B C øD øD1 Wire x Cable length Weight Model B C øD E Weight Model


dim. (m) (g) (g)
M12 x 1,5 40 15 11 4 x 0,34 mm2 2 80 0523057 M12 x 1,5 40,5 20 Pg 7 26 0523055
M12 x 1,5 40 15 11 4 x 0,34 mm2 5 200 0523052

Warning
These products are intended for use in industrial compressed air and event of such failure.
fluid systems only. Do not use these products where pressures and System designers must provide a warning to end users in the system
temperatures can exceed those listed under »Technical features/data«. instructional manual if protection against a failure mode cannot be
Before using these products with fluids other than those specified, adequately provided.
for non-industrial applications, life-support systems, or other System designers and end users are cautioned to review specific
applications not within published specifications, consult NORGREN. warnings found in instruction sheets packed and shipped with
these products.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. Functional safety (SIL):
The system designer is warned to consider the failure modes of all Suitable for certain applications can only be evaluated through
component parts used in fluid power systems and to provide adequate examination of each safety-related overall system with regard to the
safeguards to prevent personal injury or damage to equipment in the requirements of IEC 61508/61511.

Diese Produkte sind ausschließlich in Druckluft- und Fluidsystemen zu sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um
verwenden. Sie sind dort einzusetzen,Ourwo
policy one of»Technische
dieisunter continued researchMerk- Verletzungen
and development. We thereforevon Personen
reserve the right sowie Beschädigungen
to amend,  der Geräte im
en 5.4.306.12 without notice, the specifications given in this document. (2004 - 5122e) © 2015 Norgren GmbH 2/15
male/-Daten« aufgeführten Werte nicht überschritten werden. Falle einer solchen Störung zu verhindern.
Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Systemausleger sind verpflichtet, Sicherheitshinweise für den End-

You might also like