caring is our formula

TECHNICAL DATA SHEET

TECHNYL 4EARTH C2E 216M BK H


(Previously ECONAMID FL 6I1 BK)

Recycled polyamide 6, impact modified, for injection moulding, black

General
Feature Impact modified

Polymer type PA6 (Polyamide 6)

Processing technology Injection molding

Certification RoHS

Product identification
ISO 1043 abbreviation PA6-I

ISO 16396 designation PA6-I,(R100),M1,S14-030

Condition Standard Unit Value


Physical properties
Density ISO 1183 g/cm³ 1.13

Molding shrinkage, parallel ISO 294-4, 2577 % 1.1 - 1.3

Molding shrinkage, normal ISO 294-4, 2577 % 1.4 - 1.6

Viscosity number 96% H2SO4 ISO 307 cm³/g 135

Mechanical properties dam / cond.*


Tensile modulus 1 mm/min ISO 527-1/-2 MPa 2700 / -

Strain at break 50 mm/min ISO 527-1/-2 % 50 / -

Yield stress 50 mm/min ISO 527-1/-2 MPa 65 / -

Flexural modulus, ISO 178 2 mm/min ISO 178 MPa 2400 / -

Charpy impact strength, +23°C +23°C ISO 179/1eU kJ/m² NB / -

Charpy impact strength, -30°C -30°C ISO 179/1eU kJ/m² NB / -

Charpy notched impact strength, +23°C +23°C ISO 179/1eA kJ/m² 12 / -

Izod impact strength, +23°C +23°C ISO 180/1U kJ/m² NB / -

Izod notched impact strength, +23°C +23°C ISO 180/1A kJ/m² 11 / -

DOMO Engineering Plastics | Technical Service


[email protected] | www.domochemicals.com
Date of issue: 12/2024
Page 1
caring is our formula

TECHNICAL DATA SHEET TECHNYL 4EARTH C2E 216M BK H

Condition Standard Unit Value


Thermal properties
Melting temperature, 10°C/min ISO 11357-1 °C 221

Temp. of deflection under load, 0.45 MPa 0.45 MPa ISO 75 °C 155

Temp. of deflection under load, 1.80 MPa 1.80 MPa ISO 75 °C 55

Vicat softening temperature 50°C/h - 50N ISO 306 °C 185

Electrical properties
Volume resistivity IEC 62631-3-1 ohm.m 1E+013

Surface resistivity IEC 62631-3-1 ohm 1E+013

Burning behaviour
Flammability, 0.75 mm 0.75 mm UL 94 HB

Burning rate, FMVSS, Thickness 1 mm FMVSS 302 < 100 mm/min

Test run at 23°C if not differently specified, DAM state (dry as moulded), valid for black products.
*: conditioned according to ISO 1110

Processing conditions
Drying temperature/time 75-85°C / 2-4h (with dew point of dried air < -30 °C)

Recommended melt temperature 240 - 260 °C

Recommended mould temperature 60 - 90 °C

These parameters are typical of the product but should be related to the type of machinery used and to the type of moulded part. Thess TECHNYL grades are
not recommended for injection moulding hot runner systems with a diameter below 1mm.

Disclaimer
The information provided in this documentation corresponds to our technical knowledge at the date of its publication and do not
constitute a specification. This information may be subject to revision at our discretion. Domo cannot anticipate all conditions under which
this information and our products of other manufactures in combination with our products may be used. Domo accepts no responsibility
for results obtained by the application of this information or for the safety and suitability of our products alone or in combination with
other products. Users are advised to make their own tests to determine the safety and suitability of each product or product combination
for their own purposes. Unless otherwise agreed in writing, Domo sells the product without warranties. Buyers and users assume all
responsibility and liability for loss or damage arising from handling and use of our products, whether used alone or in combination with
other products. Unless specifically indicated, the grades mentioned are not suitable for applications in the pharmaceutical/medical
sector.

DOMO Engineering Plastics | Technical Service


[email protected] | www.domochemicals.com
Date of issue: 12/2024