0% found this document useful (0 votes)
30 views9 pages

Zc- 55 Enclosed Switch Datasheet en-欧母龙微动开关

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views9 pages

Zc- 55 Enclosed Switch Datasheet en-欧母龙微动开关

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Enclosed Switch

ZC-@55 CSM_ZC-_55_DS_E_3_5

Small, High-precision Enclosed Switch


• Small, High-precision Enclosed Switches with Built-in Basic
Switches for High Repeatability and Durability of 10 Million
Operations Minimum.
• Same mounting pitch as Z Basic Switch.
• Requires less operating force than conventional limit switches.
• Lineup includes modes with operation indicators for easy
maintenance and inspection.
• Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for Information on approved
models.)
For the most recent information on models that have been certified for
Be sure to read Safety Precautions on page 8 and
safety standards, refer to your OMRON website.
Safety Precautions for All Limit Switches.

Model Number Structure


Model Number Legend
ZC-@55 (1) Actuator
D: Plunger W: Short hinge lever
(1) Q: Panel mount plunger W1: Hinge lever
Q22: Panel mount roller plunger W2: Short hinge roller lever
Q21: Panel mount crossroller plunger W21: Hinge roller lever
N22: Sealed roller plunger W3: One-way action short hinge roller lever
N21: Sealed crossroller plunger W31: One-way action hinge roller lever

Ordering Information
Approved Standards
Actuator Model
UL CSA EN

Plunger ZC-D55 z z z

Panel mount
ZC-Q55 z z z
plunger
Panel mount
ZC-Q2255 z z z
roller plunger
Panel mount
ZC-Q2155 z z z
crossroller plunger
Sealed roller
ZC-N2255 z z z
plunger
Sealed crossroller
ZC-N2155 z z z
plunger
Short hinge
ZC-W55 z z z
lever

Hinge lever ZC-W155 z z z

Short hinge
ZC-W255 z z z
roller lever
Hinge roller Note: 1. Use molded terminal models when using the
ZC-W2155 z z z
lever Switch under one of the following conditions:
a) dusty, b) high amount of dripping oil, or c)
One-way action
high humidity. Refer to Molded Terminal Model
short hinge roller ZC-W355 z z z in page 2 for the details.
lever 2. Models are available with lead outlets in three
One-way action positions: right-hand, left-hand, and underside.
ZC-W3155 z z z
hinge roller lever

1
ZC-@55

Molded Terminal Model


Use of the molded terminal model is recommended in locations subject to excessive dust, oil drips, or moisture. The molded terminal model will
have the same dimensions and operating characteristics as the basic model in each. Not approved by UL, CSA or EN.
Location of
Actuator lead output Left-hand Right-hand Underside
Length
1M ZC-D55-ML VCT 1M ZC-D55-MR VCT 1M ZC-D55-MD VCT 1M
Plunger
3M ZC-D55-ML VCT 3M ZC-D55-MR VCT 3M ZC-D55-MD VCT 3M
1M ZC-Q55-ML VCT 1M ZC-Q55-MR VCT 1M ZC-Q55-MD VCT 1M
Panel mount plunger
3M ZC-Q55-ML VCT 3M ZC-Q55-MR VCT 3M -
1M ZC-Q2255-ML VCT 1M ZC-Q2255-MR VCT 1M ZC-Q2255-MD VCT 1M
Panel mount roller plunger
3M ZC-Q2255-ML VCT 3M ZC-Q2255-MR VCT 3M ZC-Q2255-MD VCT 3M
1M ZC-Q2155-ML VCT 1M ZC-Q2155-MR VCT 1M ZC-Q2155-MD VCT 1M
Panel mount crossroller plunger
3M - ZC-Q2155-MR VCT 3M ZC-Q2155-MD VCT 3M
1M ZC-N2255-ML VCT 1M ZC-N2255-MR VCT 1M ZC-N2255-MD VCT 1M
Sealed roller plunger
3M ZC-N2255-ML VCT 3M ZC-N2255-MR VCT 3M ZC-N2255-MD VCT 3M
1M - ZC-N2155-MR VCT 1M ZC-N2155-MD VCT 1M
Sealed crossroller plunger
3M - ZC-N2155-MR VCT 3M -
Short hinge lever 1M - ZC-W55-MR VCT 1M -
Hinge lever 1M ZC-W155-ML VCT 1M ZC-W155-MR VCT 1M ZC-W155-MD VCT 1M
Short hinge roller lever 1M ZC-W255-ML VCT 1M ZC-W255-MR VCT 1M ZC-W255-MD VCT 1M
Hinge roller lever 1M ZC-W2155-ML VCT 1M ZC-W2155-MR VCT 1M -
One-way action short hinge roller
1M - ZC-W355-MR VCT 1M -
lever

Location of lead output Lead Supplies


Right-hand MR Nominal External
Specifi- Terminal
Left-hand ML Leads cross-sectional diameter
cation connections
area (mm2) (mm)
Underside MD
V.C.T. Black: COM
3 conductor:
(vinyl cabtire 1.25 White: NO
10.5 dia.
cable) Red: NC

2
ZC-@55

Operation Indicator-equipped Models


Some models can be equipped upon request with a operation indicator to facilitate maintenance and inspection. Because the indicator is
incorporated in the Terminal Protective Cover, the dimensions of the Limit Switch are not affected. In this model, the lead wire is to be connected
to the screw terminal. (A connecting washer is provided on the tip of the lead wire). The lead wire can be connected to either the NC or NO terminal.
Operating characteristics are the same as the basic model from in each. Not approved by UL, CSA and EN.
* 12/24 VDC products are not subject to EN standards because their voltage is below that subject to CE marking regulations.
Actuator AC DC (12VDC) * DC (24VDC) *
Plunger ZC-D55-L - ZC-D55-L4
Panel mount plunger ZC-Q55-L - ZC-Q55-L4
Panel mount roller plunger ZC-Q2255-L ZC-Q2255-L2 ZC-Q2255-L4
Panel mount crossroller plunger ZC-Q2155-L - ZC-Q2155-L4
Sealed roller plunger ZC-N2255-L ZC-N2255-L2 ZC-N2255-L4
Sealed crossroller plunger ZC-N2155-L ZC-N2155-L2 ZC-N2155-L4
Hinge lever ZC-W155-L - ZC-W155-L4
Short hinge roller lever ZC-W255-L - ZC-W255-L4
Hinge roller lever ZC-W2155-L - ZC-W2155-L4

(For AC) (For DC)


• The operating voltage range is from 90 to 250 VAC. • The DC-operated is provided with an LED indicator.
• The dimensions are the same as the standard type. The top of the • There is no protective structure.
Terminal Protective Cover is transparent to allow checking the • Since a rectifier stack is incorporated into the unit to permit reversing
operation easily. the polarity, this type can also operate on AC power source.
• The LED projects from the housing for easy visibility.

Contact Circuit
Voltage rating Leakage current Internal
Model
(V) (mA) resistance (kΩ)
Power supply
L2 12 Approx.2.4 4.3
Neon lamp
R = 240 kΩ
L4 24 Approx.1.2 18

Contact Circuit
NC terminal
Power supply
Load

LED
Built-in switch
Resistor

Power supply NC terminal


Built-in switch

Load

NO terminal
Load
Built-in switch

Power supply
Built-in switch
Neon lamp R = 240 kΩ

Note: If the wiring is as shown above, the operation of the respective parts will
be as shown in the following table. The neon lamp is not wired when the
Switch is delivered. Connect it as required. NO terminal Load

Contact Neon lamp Load Actuator


ON Does not operate Operates Resistor
NC
OFF Operates Does not operate LED
ON Does not operate Does not operate
NO
OFF Operates Operates Note: If the wiring is as shown above, the operation of the respective parts will
be as shown in the following table. The LED terminals are not wired when
the Switch is delivered. Connect it as required.
Contact LED Load Actuator
ON Does not operate Operates
NC
OFF Operates Does not operate
ON Does not operate Does not operate
NO
OFF Operates Operates

3
ZC-@55

Accessories
MODEL
ZC Terminal Cover TERMINAL COVER FOR ZC55
ZC Seal Rubber SC-R40
ZC Rubber Packing ZC RUBBER PACKING
Note: The Switch is equipped with these 3 items as a standard.

4
ZC-@55
Specifications
Approved Standards
Agency Standard File No.
UL* UL508 E76675
TÜV Rheinland EN60947-1, EN60947-5-1 J50041904
Contact your OMRON
CCC(CQC) GB/T14048.5
representative for details.
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.

Ratings Approved Standard Ratings


Non-inductive load (A) Inductive load (A) UL/CSA
Rated A300
Resistive load Lamp load Inductive load Motor load
voltage
NC NO NC NO NC NO NC NO Volt-amperes
Carry Current (A)
Voltage (VA)
125 VAC 10 3 1.5 10 5 2.5 current
250 VAC 10 2.5 1.25 10 3 1.5 Make Break Make Break
8 VDC 10 3 1.5 6 5 2.5 120 VAC 60 6
10A 7,200 720
14 VDC 10 3 1.5 6 5 2.5 240 VAC 30 3
30 VDC 6 3 1.5 5 5 2.5
125 VDC 0.5 0.4 0.4 0.05 0.05 0.05 TÜVRheinland (EN60947-1, EN60947-5-1),
250 VDC 0.25 0.2 0.2 0.03 0.03 0.03
CCC (GB/T14048.5)
NC 30 A max. Applicable category and ratings
Inrush
current NO 15 A max. AC-12 10 A/250 VAC
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions
according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.

Characteristics Engineering Data


Degree of protections *3 IP67 (EN60947-5-1) Electrical Durability
Mechanical 10,000,000 operations min. 10,000
Durability 7,000
Electrical 500,000 operations min. 5,000
125 VAC cosφ=1
Operating speed 0.05 mm/s to 0.5 m/s *1 3,000
Durability (×104 operations)

125 VAC cosφ=0.4


Operating Mechanical 120 operations/min
frequency 250 VAC cosφ=1
Electrical 20 operations/min 1,000
700 250 VAC cosφ=0.4
Insulation resistance 100 MΩ min. (at 500 VDC)
500
15 mΩ max. (initial value for the built-
Contact resistance 300
in switch when tested alone)
Between non-continu-
1,000 VAC, 50/60 Hz for 1 min
ous terminals 100
Dielectric 70
strength Between each terminal 50
and non-current-carry- 2,000 VAC, 50/60 Hz for 1 min
30 Operating temperature: +20±2°C
ing metal parts Operating humidity: 65±5%RH
Rated insulation voltage (Ui) 1,000 VAC Operating frequency: 20 operations/min
10
Pollution degree 0 2 4 6 8 10 12
3 (IEC947-5-1)
(operating environment) Switching current (A)
Short-circuit protective device 10 A-fuse type gG (IEC 60269)
Protection against electric shock Class II Mechanical Durability (for ZC-Q55)
Proof tracking index (PTI) 175
10,000
Switch category D (IEC335) 7,000
5,000
Rated operating current (Ie) 10 A
3,000
Rated operating voltage (Ue) 250 VAC
Vibration 10 to 55 Hz, 1.5-mm double ampli-
Malfunction
Durability (×104 operations)

resistance tude *2 1,000


700
Destruction 1,000 m/s2 max. 500
Shock
resistance Malfunction 300 m/s2 max. 300
(in case of plunger model) *1 *2
Ambient operating temperature −10°C to +80°C (with no icing)
100
Ambient operating humidity 35% to 95%RH 70
50
Approx. 92 g (in case of ZC- Operating temperature: +20±2˚C
Weight
Q22(21)55) 30 Operating humidity: 65±5%RH
No load
*1. Only for models with plungers. (Contact your OMRON representative for Operating frequency: 120 operations/min
information on other models.)
0 0.1 0.3 0.5 0.7 1 3 5 7 10
*2. Less than 1 ms under a free state at the operating limits.
*3. The degree of protection is tested using the method specified by the OT (mm)
standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand.

5
ZC-@55
Structure and Nomenclature
Structure Contact Form
Changing the Terminal Protective Cover around allows the cable to
be pulled out from either the right or the left.
(COM)1 2(NC)
Roller 3(NO)

Plunger
Case
NC fixed contact
Moving contact
Switch
NO fixed contact
Packing Seal rubber

Terminal Protective
Cover
Common Normally Normally
terminal open closed terminal (NC)
(COM) terminal (NO)
Note: M4 binding head screws (with toothed washers) are used as the terminal screws.

Dimensions and Operating Characteristics (Unit: mm)

Plunger Panel Mount Plunger


7.8 dia.*1
ZC-D55 ZC-Q55 53.4
53.4 PT A 23.3
14 dia.
PT A 23.3 14 Two M14 × 1
7.8 dia. * hexagon nuts *3
12.5 *2 14
8
OP
OP
21 19 21 19

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15 25.4±0.15
(21 × 21)
15 (21 × 15
Terminal Protective Cover 55 Two, 4.3±0.1 dia. 21.7 Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) mounting holes (NBR)
*Stainless steel plunger *1. Stainless steel plunger
*2. The length of the imperfect threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
Note: Do not use the M14 mounting
screw and the case mounting
hole at the same time.

Panel Mount Roller Plunger Panel Mount Crossroller Plunger


11 dia. × 4.7 *1
ZC-Q2255 PT A
53.4
23.3
ZC-Q2155 PT Set position
indication line A
53.4 11 dia. × 4.7 *1
Set position indication line 23.3 14
(3.6) (3.6)
Two M14 × 1
Two M14 × 1
hexagon nuts *3
(2.25) hexagon nuts *3
12.5 *2 *2 (2.25)
14 12.5
OP OP

21 19 21 19

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15
15 (21 × 21) 25.4±0.15
15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber 55
Terminal protective cover Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) (NBR)
mounting holes
*1. Stainless sintered alloy roller
*2. The length of the imperfect threads is 1.5 mm maximum. *1. Stainless sintered alloy roller
*3. Thickness: 3 width: 17 *2. The length of the imperfect threads is 1.5 mm maximum.
Note: Do not use the M14 mounting *3. Thickness: 3 width: 17 Note: Do not use the M14 mounting
screw and the case mounting screw and the case mounting
hole at the same time. hole at the same time.

Sealed Roller Plunger Sealed Crossroller Plunger


ZC-N2255 53.4 9.5 dia. × 4.7 * ZC-N2155 53.4
A Rubber boot PT A
Rubber boot 9.5 dia. × 4.7 *
PT 23.3 23.3 14
(chloroprene rubber) (chloroprene rubber)

14
OP OP

19 19

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
* Stainless sintered alloy roller mounting holes (NBR) * Stainless sintered alloy roller mounting holes (NBR)

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. Operating characteristics are for when the Switch is operated from direction A.

6
ZC-@55

Short Hinge Roller Lever Hinge Lever


ZC-W55 53.4 ZC-W155 53.4
34.6 14 34.6 14
t=1 *
A
t=1 * 70R
A
50R 8 8

FP FP
OP OP
22.5 20 22.5 20

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber 55
Terminal protective cover Two, 4.3±0.1 dia. 21.7 Seal rubber
* Stainless steel lever mounting holes (NBR) (NBR)
* Stainless steel lever mounting holes

Short Hinge Roller Lever Hinge Roller Lever


ZC-W255 53.4
A
ZC-W2155 53.4
34.6 14 12.7 dia. × 7.5 *2 34.6 14 A 12.7 dia. × 7.5 *2

t=1 *1 t=1 *1
50R 70R

FP FP
OP OP

22.5 20 22.5 20

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
*1. Stainless steel lever mounting holes (NBR) *1. Stainless steel lever mounting holes (NBR)
*2. Stainless steel roller *2. Stainless steel roller

One-way Action Short Hinge Roller Lever One-way Action Hinge Roller Lever
ZC-W355 Operating direction ZC-W3155 Operating direction
53.4
53.4
34.6 14 12.7 dia. × 7.5 *2
34.6 14 12.7 dia. × 7.5 *2 A
A
Angle of roller
swing: 90° Angle of roller
54R 73R swing: 90°
t=1 *1 t=1 *1

FP FP
OP OP

22.5 20 22.5 20

5 5
(10) (10)
22 max.18.3 22 max.18.3

25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) *1. Stainless steel lever mounting holes (NBR)
*1. Stainless steel lever
*2. Stainless steel roller *2. Stainless steel roller

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. Operating characteristics are for when the Switch is operated from direction A.

Operating Characteristics Model ZC-D55 ZC-Q55 ZC-Q2255 ZC-Q2155 ZC-N2255 * ZC-N2155 *


Operating force OF max. 11.8 N 11.8 N 11.8 N 11.8 N 6.86 N 6.86 N
Release force RF min. 4.9 N 4.9 N 4.9 N 4.9 N 1.67 N 1.67 N
Pretravel PT max. 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm
Overtravel OT min. 2.4 mm 3 mm 3 mm 3 mm 2.5 mm 2.5 mm
Movement Differential MD max. 0.2 mm 0.2 mm 0.2 mm 0.2 mm 0.2 mm 0.2 mm
Free Position FP max. --- --- --- --- --- ---
Operating Position OP 32.4±0.8 mm 38.2±0.8 mm 47.4±0.8 mm 47.4±0.8 mm 47.4±0.8 mm 47.4±0.8 mm
* Make sure that the permissible OT position is not exceeded.

Operating Characteristics Model ZC-W55 ZC-W155 ZC-W255 ZC-W2155 ZC-W355 ZC-W3155


Operating force OF max. 3.92 N 2.75 N 3.92 N 2.75 N 3.92 N 2.75 N
Release force RF min. 0.78 N 0.59 N 0.78 N 0.59 N 0.78 N 0.59 N
Pretravel PT max. --- --- --- --- --- ---
Overtravel OT min. 6 mm 8.4 mm 6 mm 8.4 mm 6 mm 8.4 mm
Movement Differential MD max. 1 mm 1.4 mm 1 mm 1.4 mm 1 mm 1.4 mm
Free Position FP max. 34.7 mm 36.7 mm 49.2 mm 51.3 mm 59.2 mm 61.2 mm
Operating Position OP 28.5±1.2 mm 28.5±1.2 mm 43±1.2 mm 43±1.2 mm 53±1.2 mm 53±1.2 mm

7
ZC-@55
Safety Precautions
Refer to Safety Precautions for All Limit Switches.

Precautions for Correct Use


Operating Environment Micro Load Models
• Seal material may deteriorate if a Switch is used outdoor or where Contact failure may occur is a General-purpose Switch is used to
subject to special cutting oils, solvents, or chemicals. Always switch a microload circuit. Use Switches within the areas shown in the
appraise performance under actual application conditions and set following chart. Even when using Microload Switches within the area
suitable maintenance and replacement periods. shown below, contact wear will become more extreme with loads that
• Install Switches where they will not be directly subject to cutting generate surge current when switching and durability will be
chips, dust, or dirt. The Actuator and Switch must also be protected adversely affected. If necessary, insert a contact protective circuit.
from the accumulation of cutting chips or sludge. Microloads are indicated by N standard reference values. This value
Not Suitable Suitable represents the failure rate at a 60% (λ60) reliability level. (JIS C5003)
The equation λ60 = 0.5 × 10−6/operations indicates that a failure rate
of 1/2,000,000 operations can be expected at a reliability level of 60%.

DC voltage (V)
0.8 W
26 mA 100 mA
30
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
24
operation failure, reduced durability, and other problems. Applicable
Excessive vibration or shock can lead to false contact operation or Applicable area area for
damage. Install Switches in locations not subject to shock and for Microload
Models
General-
purpose
vibration and in orientations that will not produce resonance. (ZC-@55-01) Models
(ZC-@55)
• The Switches have physical contacts. Using them in environments
12
containing silicon gas will result in the formation of silicon oxide Not
(SiO2) due to arc energy. If silicon oxide accumulates on the applicable
contacts, contact interference can occur. If silicon oil, silicon filling 5
1 mA 100 mA 160 mA
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge 0
0.1 1 10 100 1,000
killers) or remove the source of silicon gas.
Current (mA)
Dog Angle
Model ZC-@55-01 ZC-@55
When operating the roller type, be sure to set the dog angle to less than
Minimum applicable
30° (even when operating at a low speed). Operating the model at a dog 5 VDC 1mA 5 VDC 160mA
load
angle exceeding 30° will soon cause abrasion or damage. Do not apply a
twisting force to the plunger. Set the OT to 70% to 100% of the specified Mounting
value so that the actuator will not exceed the OT.
• When mounting the Switch with Mounting Holes
Handling screws on a side surface, fasten the
Two, 4.3-dia. or M4 screw holes
Switch with M4 screws and use
• When detaching the Terminal washers, spring washers, etc., to
Protective Cover, insert a ensure secure mounting.
screwdriver and apply a force 25.4±0.15

in the opening direction. Do


not use excess force to • When mounting the Panel Mount- Mounting Holes
remove the cover. Doing so type Enclosed Switch (ZC-Q55, ZC-
14.5+0.2
0 dia.
may cause deformation in the Q2255, or ZC-Q2155) with screws
fitting section and reduce the on a side surface, remove the
holding force. hexagonal nuts from the actuator.
• When mounting the Terminal Appropriate Tightening Torque
Protective Cover to the case,
A loose screw may result in a malfunction. Be sure to tighten each
align the cover on the case and then press the cover down to mount
screw to the proper tightening torque as shown below.
it firmly. If the cover is pressed down in an inclined position, rubber
packing will deform and thus affect the sealing capability. Appropriate Tightening
No. Type
Torque
(1) Terminal screw 0.78 to 1.18 N·m
(2) Panel mounting screw 4.90 to 7.84 N·m
(3) Side mounting screw 1.18 to 1.47 N·m

Operation
Rubber packing Rubber packing With the ZC-Q22(21)55, an
• A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the appropriate OT line is marked on
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.) the plunger. Set the OT so that it is
• Use weather-proof rubber (chloroprene rubber) as seal rubber for between the two X-surface lines.
the ZC-N22(21)55.

8
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

2024.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2024 All Right Reserved.

You might also like