Ordering Information
Approved Standards
Actuator Model
UL CSA EN
Plunger ZC-D55 z z z
Panel mount
ZC-Q55 z z z
plunger
Panel mount
ZC-Q2255 z z z
roller plunger
Panel mount
ZC-Q2155 z z z
crossroller plunger
Sealed roller
ZC-N2255 z z z
plunger
Sealed crossroller
ZC-N2155 z z z
plunger
Short hinge
ZC-W55 z z z
lever
Short hinge
ZC-W255 z z z
roller lever
Hinge roller Note: 1. Use molded terminal models when using the
ZC-W2155 z z z
lever Switch under one of the following conditions:
a) dusty, b) high amount of dripping oil, or c)
One-way action
high humidity. Refer to Molded Terminal Model
short hinge roller ZC-W355 z z z in page 2 for the details.
lever 2. Models are available with lead outlets in three
One-way action positions: right-hand, left-hand, and underside.
ZC-W3155 z z z
hinge roller lever
1
ZC-@55
2
ZC-@55
Contact Circuit
Voltage rating Leakage current Internal
Model
(V) (mA) resistance (kΩ)
Power supply
L2 12 Approx.2.4 4.3
Neon lamp
R = 240 kΩ
L4 24 Approx.1.2 18
Contact Circuit
NC terminal
Power supply
Load
LED
Built-in switch
Resistor
Load
NO terminal
Load
Built-in switch
Power supply
Built-in switch
Neon lamp R = 240 kΩ
Note: If the wiring is as shown above, the operation of the respective parts will
be as shown in the following table. The neon lamp is not wired when the
Switch is delivered. Connect it as required. NO terminal Load
3
ZC-@55
Accessories
MODEL
ZC Terminal Cover TERMINAL COVER FOR ZC55
ZC Seal Rubber SC-R40
ZC Rubber Packing ZC RUBBER PACKING
Note: The Switch is equipped with these 3 items as a standard.
4
ZC-@55
Specifications
Approved Standards
Agency Standard File No.
UL* UL508 E76675
TÜV Rheinland EN60947-1, EN60947-5-1 J50041904
Contact your OMRON
CCC(CQC) GB/T14048.5
representative for details.
Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
5
ZC-@55
Structure and Nomenclature
Structure Contact Form
Changing the Terminal Protective Cover around allows the cable to
be pulled out from either the right or the left.
(COM)1 2(NC)
Roller 3(NO)
Plunger
Case
NC fixed contact
Moving contact
Switch
NO fixed contact
Packing Seal rubber
Terminal Protective
Cover
Common Normally Normally
terminal open closed terminal (NC)
(COM) terminal (NO)
Note: M4 binding head screws (with toothed washers) are used as the terminal screws.
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15 25.4±0.15
(21 × 21)
15 (21 × 15
Terminal Protective Cover 55 Two, 4.3±0.1 dia. 21.7 Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) mounting holes (NBR)
*Stainless steel plunger *1. Stainless steel plunger
*2. The length of the imperfect threads is 1.5 mm maximum.
*3. Thickness: 3 width: 17
Note: Do not use the M14 mounting
screw and the case mounting
hole at the same time.
21 19 21 19
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15
15 (21 × 21) 25.4±0.15
15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber 55
Terminal protective cover Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) (NBR)
mounting holes
*1. Stainless sintered alloy roller
*2. The length of the imperfect threads is 1.5 mm maximum. *1. Stainless sintered alloy roller
*3. Thickness: 3 width: 17 *2. The length of the imperfect threads is 1.5 mm maximum.
Note: Do not use the M14 mounting *3. Thickness: 3 width: 17 Note: Do not use the M14 mounting
screw and the case mounting screw and the case mounting
hole at the same time. hole at the same time.
14
OP OP
19 19
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
* Stainless sintered alloy roller mounting holes (NBR) * Stainless sintered alloy roller mounting holes (NBR)
6
ZC-@55
FP FP
OP OP
22.5 20 22.5 20
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber 55
Terminal protective cover Two, 4.3±0.1 dia. 21.7 Seal rubber
* Stainless steel lever mounting holes (NBR) (NBR)
* Stainless steel lever mounting holes
t=1 *1 t=1 *1
50R 70R
FP FP
OP OP
22.5 20 22.5 20
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
*1. Stainless steel lever mounting holes (NBR) *1. Stainless steel lever mounting holes (NBR)
*2. Stainless steel roller *2. Stainless steel roller
One-way Action Short Hinge Roller Lever One-way Action Hinge Roller Lever
ZC-W355 Operating direction ZC-W3155 Operating direction
53.4
53.4
34.6 14 12.7 dia. × 7.5 *2
34.6 14 12.7 dia. × 7.5 *2 A
A
Angle of roller
swing: 90° Angle of roller
54R 73R swing: 90°
t=1 *1 t=1 *1
FP FP
OP OP
22.5 20 22.5 20
5 5
(10) (10)
22 max.18.3 22 max.18.3
25.4±0.15 25.4±0.15
15 (21 × 21) 15 (21 × 21)
Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber Terminal protective cover 55 Two, 4.3±0.1 dia. 21.7 Seal rubber
mounting holes (NBR) *1. Stainless steel lever mounting holes (NBR)
*1. Stainless steel lever
*2. Stainless steel roller *2. Stainless steel roller
7
ZC-@55
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
DC voltage (V)
0.8 W
26 mA 100 mA
30
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
24
operation failure, reduced durability, and other problems. Applicable
Excessive vibration or shock can lead to false contact operation or Applicable area area for
damage. Install Switches in locations not subject to shock and for Microload
Models
General-
purpose
vibration and in orientations that will not produce resonance. (ZC-@55-01) Models
(ZC-@55)
• The Switches have physical contacts. Using them in environments
12
containing silicon gas will result in the formation of silicon oxide Not
(SiO2) due to arc energy. If silicon oxide accumulates on the applicable
contacts, contact interference can occur. If silicon oil, silicon filling 5
1 mA 100 mA 160 mA
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge 0
0.1 1 10 100 1,000
killers) or remove the source of silicon gas.
Current (mA)
Dog Angle
Model ZC-@55-01 ZC-@55
When operating the roller type, be sure to set the dog angle to less than
Minimum applicable
30° (even when operating at a low speed). Operating the model at a dog 5 VDC 1mA 5 VDC 160mA
load
angle exceeding 30° will soon cause abrasion or damage. Do not apply a
twisting force to the plunger. Set the OT to 70% to 100% of the specified Mounting
value so that the actuator will not exceed the OT.
• When mounting the Switch with Mounting Holes
Handling screws on a side surface, fasten the
Two, 4.3-dia. or M4 screw holes
Switch with M4 screws and use
• When detaching the Terminal washers, spring washers, etc., to
Protective Cover, insert a ensure secure mounting.
screwdriver and apply a force 25.4±0.15
Operation
Rubber packing Rubber packing With the ZC-Q22(21)55, an
• A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the appropriate OT line is marked on
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.) the plunger. Set the OT so that it is
• Use weather-proof rubber (chloroprene rubber) as seal rubber for between the two X-surface lines.
the ZC-N22(21)55.
8
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
2024.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2024 All Right Reserved.