Ra2300a Com Manual
Ra2300a Com Manual
Command
RA2000 series
INSTRUCTION MANUAL
1WMPD4003507
Communication Command
RA2000 series
INSTRUCTION MANUAL
Introduction
We thank you for your purchase of our product OMNIACE RA2000 series (RA2300MK Ⅱ and
RA2800A). Please read this manual before operating this instrument. Refer to this manual to operate
the LAN interface which is provided as standard in the RA2000 and the RS-232C interface included in
the optional RS-232C unit (RA23-142). This manual provides the information necessary to operate the
RA2000 series recorder safely. Place this manual within reach of the RA2000 series.
For basic operations, please refer to the RA2000 series Recorder Manual. Please read the user’s
manual of the PC or modem before connecting the RA2000 series to a PC or modem. If you encounter
any problems in the manuals, please contact our sales representative.
This manual covers handling precautions and basic command operations of the RA2000 series
communication interface. For operation of basic functions, please refer to the separate-volume
manuals listed below.
<RA2300MKⅡ>
Manual Contents
Instruction Manual
This manual explains functions and how to operate the RA2300A.
MAINFRAME for RA2300MKⅡ
Instruction Manual
Amplifier Units This manual explains how to use and install amp units.
for RA2000 series
<RA2800A>
Manual Contents
Instruction Manual
This manual explains functions and how to operate the RA2800A.
MAINFRAME for RA2800A
Instruction Manual
Amplifier Units This manual explains how to use and install amp units.
for RA2000 series
█ Before Using
1
█ Safety Measures - Warnings and Cautions
► To safely use the product
The RA2000 series is a product conforming to the IEC standard safety class I. The recorder is
manufactured with safety in mind, however, accidents may occur due to misuse by the user. To
avoid such accidents, read this manual carefully before use. Observe the following warnings and
cautions when using the interface and remote control functions. To safely use the input units, the
following statements are used in this manual to call the readers' attention.
Be sure to observe the following instructions when using this recorder. The warranty does not
cover damages resulting from actions contrary to the instructions, cautions, or warnings
appearing in this manual.
CAUTION
2
█ Warranty - General
We ship our products after conducting quality control, which covers from design to manufacturing. It is,
however, possible that failures may occur in products. If the product does not operate correctly, please
make a check of the power supply, cable connections, or other conditions before returning this product
to us. For repair or calibration, contact our sales agency. Before returning, be sure to inform us of the
model, serial number, and problematic points. The following is our warranty.
█ Limited Warranty
(1) Warranty period
One year from our shipment.
(3) Liability
We do not assume any liabilities for equipment other than A&D.
3
█ Terms and Symbols in This Manual
The terms and symbols used in this manual denote the following.
Term or Symbol Description
This indicates a condition or practice that could result in personal injury or
WARNING loss of life, or may result in light injury or physical damage if this equipment is
misused due to neglect of a Warning.
This indicates a condition or practice that could result in light injury or damage
CAUTION to the equipment or other property if this equipment is misused due to neglect
of a Caution.
This indicates a condition or practice that could result in incorrect operation or
NOTE damage to data if this equipment is misused due to neglect of a Note.
Reference page
4
Introduction......................................................................................................................1
█ Warranty - General............................................................................................................. 3
5
3.2. Recording in General ....................................................................................................... 3-2
SSS (Set filing Save Setting) Setting place where to save files .................................................... 3-2
3.3. Waveform Chart Recording ............................................................................................. 3-3
SCS (Set Chart Speed) Setting paper feed speed of waveform chart printing............................. 3-3
3.4. Memory Recording ............................................................................................................ 3-4
SSC (Set Sampling Clock) Setting memory sampling speed .......................................................... 3-4
SBS (Set Block Size) Setting block size ........................................................................................... 3-4
SML (Set Memory Length) Setting memory block size .................................................................... 3-5
SMB (Set Memory Block) Setting block No. ..................................................................................... 3-5
STD (Set Trigger Delay) Setting pre-trigger ...................................................................................... 3-5
STE (Set Trigger Execution) Setting trigger execution ..................................................................... 3-5
SMC(Set Memory Copy) Sets the readout amount ............................................................................ 3-5
3.5. HD Recording .................................................................................................................... 3-6
SRF (Set Real-time Filing) Setting HD recorder basics ................................................................... 3-6
SFT (Set Filing Time) Setting recording time.................................................................................... 3-6
SRT Set Real-time Trigger) Setting real-time recording operation .................................................. 3-6
3.6. X-Y Recording.................................................................................................................... 3-7
SCS (Set Chart Speed) HD recording speed of X-Y recorder ......................................................... 3-7
SXA (Set X-Axis) Sets X axis channel................................................................................................ 3-7
SYC (Set Y-Ch) Sets Y axis channels................................................................................................ 3-7
3.7. Trigger ................................................................................................................................ 3-8
STM (Set Trigger Mode) Setting trigger mode.................................................................................. 3-8
STC (Set Trigger mode OR, AND Channel) Setting OR, AND trigger condition .......................... 3-8
STW (Set Trigger Window) Setting WINDOW trigger condition ...................................................... 3-8
STF (Set Trigger Filter) Sets trigger filter............................................................................................ 3-9
3.8. Amp Unit .......................................................................................................................... 3-10
SCH (Set CHannel) Setting HRDC amp.......................................................................................... 3-10
SCH (Set CHannel) Setting FFT amp ............................................................................................. 3-11
SCH (Set CHannel) Setting HSDC amp .......................................................................................... 3-11
SCH (Set CHannel) Setting ACST amp........................................................................................... 3-12
SAR (Set Ac strain amp R-fine) Setting R-balance........................................................................ 3-12
SCH (Set CHannel) Setting EV amp ............................................................................................... 3-13
SCH (Set CHannel) Setting TCDC amp .......................................................................................... 3-13
SCH (Set CHannel) Setting TDC amp............................................................................................. 3-14
SCH (Set CHannel) Setting FV amp................................................................................................ 3-14
SCH (Set CHannel) Setting RMS amp ............................................................................................ 3-15
SCH (Set CHannel) Setting DCST amp .......................................................................................... 3-16
SCH (Set CHannel) Setting HRZS amp .......................................................................................... 3-16
SCH (Set CHannel) Setting Extra Event (E1)................................................................................. 3-17
SUS (Set User Scale) Sets user-scale.............................................................................................. 3-17
3.9. Setting for Display and Printing................................................................................... 3-18
SWD (Set Scale Wave Division) Setting Waveform Division .......................................................... 3-18
SWF (Set Scale Wave flame) Setting Waveform Frame size......................................................... 3-18
3.10. Output to File and Recording Paper (including Backup Filing)............................ 3-19
SMF (Set Memory Filing) Setting Filing ........................................................................................... 3-19
SPS (Set Print Size) Sets copy scaling ............................................................................................ 3-19
3.11. System – Recording Setting ....................................................................................... 3-20
SRC (Set Record Ch) Setting record channel ................................................................................ 3-20
SDN (Set Data No.) Setting Data No.............................................................................................. 3-20
SAN (Set Annotation ON/OFF) Setting annotation print................................................................. 3-20
SPA (Set Print Auxiliary) Setting measurement information and signal name print .................... 3-21
SGP (Set Grid Pattern) Sets grid pattern.......................................................................................... 3-21
SAS (Set Auto Scaling) Sets auto scaling (ON/OFF) ...................................................................... 3-21
SSM (Set Scale Mode) Sets auto scaling mode .............................................................................. 3-21
3.12. System - Maintenance .................................................................................................. 3-22
SDT (Set DaTe) Setting clock .......................................................................................................... 3-22
6
3.13. Other Settings ............................................................................................................... 3-23
STR (Set TRans CH.) Setting real-time transfer channel .............................................................. 3-23
SIM (Set Input Monitor) Setting display speed of input monitor ................................................... 3-23
SAT (Set Auto Transmit) Setting transmit function ......................................................................... 3-23
SIF Setup for pause of Input monitor................................................................................................ 3-24
SIS Setting sync trigger....................................................................................................................... 3-24
SRI Setting data acquisition and printing........................................................................................... 3-24
SBR Setting basic Recording setting ................................................................................................. 3-25
3.14. Compatibility with Older Series .................................................................................. 3-25
SRM (Set Recording Mode) Setting measurement mode............................................................... 3-25
SAC (Set Auto Copy) Set auto copy................................................................................................. 3-25
SMI (Set Memory autocopy Icon) Sets auto copy............................................................................ 3-25
SFI (Set Filing Icon) Sets ON/OFF the filing icon. .......................................................................... 3-26
SYA (Set Y-Axis) Sets Y-axis channels............................................................................................. 3-26
SMD (Set Memory Division) Setting channel combination ............................................................. 3-26
7
ICH (Inquire CHannel) Reading FV amp setting............................................................................. 4-14
ICH (Inquire CHannel) Reading RMS amp setting ......................................................................... 4-14
ICH (Inquire CHannel) Reading DCST amp setting ....................................................................... 4-15
ICH (Inquire CHannel) Reading HRZS amp setting ....................................................................... 4-15
ICH (Inquire CHannel) Reading extra event (E1) setting............................................................... 4-16
ICH (Inquire CHannel) Reading invalid amp setting ....................................................................... 4-16
IUS (Inquire User Scale) Reading user-scale ................................................................................... 4-16
4.9. Output to File and Recording Paper (including Backup Filing).............................. 4-17
IMF (Inquire Memory Filing) Reading memory filing setting........................................................... 4-17
IWD (Inquire Scale Wave Division) Reading Waveform Division .................................................... 4-17
IWF (Inquire Scale Wave flame) Reading Waveform Frame size .................................................. 4-17
4.10. System – Recording Setting ....................................................................................... 4-18
IRC (Inquire
Record Ch) Reading recording channel ..................................................................... 4-18
IDN (Inquire
Data No.) Reading data No. ....................................................................................... 4-18
IAN (Inquire
ANnotation) Reading annotation print setting ............................................................. 4-18
IPA (Inquire
Print Auxiliary) Reading settings of measurement information
and signal name printing.…………………………………………….…4-18
IGP (Inquire Grid Pattern) Reading grid pattern ............................................................................... 4-19
IAS (Inquire Auto Scaling) Reading auto scaling (ON/OFF) ............................................................ 4-19
ISM (Inquire Scale Mode) Reading auto scaling mode.................................................................... 4-19
4.11. System - Maintenance .................................................................................................. 4-20
IWH (Inquire WHo) Reading version information ............................................................................ 4-20
IDT (Inquire DaTe) Reading clock.................................................................................................... 4-20
4.12. Other Settings ............................................................................................................... 4-21
IES (Inquire Error Status) Reading error status.............................................................................. 4-21
IIM (Inquire Input Monitor) Reading display speed of input monitor ............................................. 4-21
IDA (Inquire Input monitor DAta) Reading measurement value of input signal ........................... 4-22
IAT (Inquire Auto Transmit) Reading transmit function................................................................... 4-22
ICA (Inquire Auto Transmit CAtion) Reading transmit factor ......................................................... 4-23
IIF Reading Pause of Input monitor ................................................................................................. 4-23
IIS Reading sync trigger condition.................................................................................................... 4-23
IRI Reading data acquisition and printing condition........................................................................ 4-23
IBR Reading time axis display............................................................................................................ 4-23
4.13. Compatibility with Older Series .................................................................................. 4-24
IRM (Inquire Recording Mode) Reading measurement mode ........................................................ 4-24
IAC (Inquire Auto Copy) Reading auto copy .................................................................................... 4-24
IRS (Inquire Rec icon information) Reading recording icon conditions......................................... 4-24
IMP (Inquire Memory block Point) Reading block No. ................................................................... 4-24
IYA (Inquire Y-Axis) Reading Y-axis channels .................................................................................. 4-25
IMD (Inquire Memory Division) Reading channel combination ....................................................... 4-25
8
ERS (Execute Real-time data trans Start) Executing real-time transition ....................................... 5-6
ERE (Execute Real-time data trans End) Stopping real-time transition.......................................... 5-6
5.5. Others ................................................................................................................................. 5-6
EPA (Execute Page Annotation) Executing page annotation print .................................................. 5-6
EFD (Execute paper FeeD) Executing paper feed ........................................................................... 5-6
ESI (Execute System Initialize) System initialize command ............................................................. 5-6
8. Reference..................................................................................................................8-1
9
1. Selection of
Communication Interface
1. Selection of Communication Interface
Select
communication
setup
Operation panel
(1) None
(2) LAN
(3) RS-232C
(1) None
Reception of the RS-232C and GP-IB interfaces are neglected and commands are rejected.
(2) LAN
The LAN interface is used.
(3) RS-232C
The RS-232C interface is used.
When the RA2300MKⅡ is connected to UPS and a tick mark is added to the checkbox for “Connecting
UPS to RS-232C”, safety shutdown of the RA2300MKⅡ can be made upon a power outage. After the
power supply is resumed, startup is automatically made. If the power outage happens during recording
or printing, the operation will be re-started.
For how to connect UPS, refer to the instruction manual for the UPS to be used.
A special UPS connection cable is necessary when connecting the RA2300MKⅡ with
TIPS
UPS. The RS232C cable of the commercial item cannot be used. Please inquire of our
sales representative about UPS and the cable that can be used.
CAUTIONS:
- Please do not check “Allow network users to
change my files” as control from remote PC
may influence measuring.
- Please do not share files on C:CF drive.
1) Open the “System – Communication Setup” screen of RA2000 series to set up a communication
device to be connected.
2) Press the “LAN Setup” button on the “System – Communication Setup” screen of RA2000 series to
open the next screen for setting.
3) Start NS3000
Double-click the shortcut icon of Unifizer.exe on the PC desktop to start the program. If the program
starts without any errors, the initial screen is displayed as below.
* Note: Following the instruction manual, install the NS 3000.
Once the connection is established, the device appears on the tree window as below.
5) Set RA2000A
Click to any device icon on the tree to display advanced setting items for the device on the advanced
setting window. On this window, set the recording mode, sampling, and others for the recorder.
Click [Device]
When pressing the [Apply] button, the setting becomes valid and is reflected in the recorder.
When pressing the [Undo] button before accepting, the original settings are returned. However, after
accepting, the settings are not returned.
Finish recording.
When the RA2000 is switched to remote control mode, recording continues and the remote
control mode screen is displayed. In the remote control mode, all controls performed via the
control/touch are ignored.
Local mode Remote control mode
or
EST
Command content StarT
Command type
X Communication Control
S Setting
I Read Setting
E Execute
F File/Data Control
T Text
R Read Data
W Write Data
Input a parameter following the 3-character command. Insert a separator (comma ”,” or space ” ”)
between parameters. When it is possible to omit parameters, it is necessary to insert commas in
sequence instead of parameters in order to clearly indicate that the parameters are omitted. Lastly
input a delimiter and operation is complete. Available delimiters are [CR+LF], [CR], [LF], etc., and it
is necessary to use the same delimiter as that set in the RA2000.
When the parameter can be omitted, “Can be omitted” is specified in the command
description. In other cases, parameters cannot be omitted.
[ESC]+’Z’ Go to Local
Function Returns to the local state. The key control on the panel becomes valid.
Input Format [ESC]+’Z’ <1Bh> <5Ah>
Output Format None
Description Note that, if a delimiter is added (CR, LF, or others), the mode returns to the
remote again after going back to the local because of the delimiter detection.
Description
Description
SSS (Set filing Save Setting) Setting place where to save files
Function Sets place where to save files.
Input Format SSS P1, P2, P3, P4, P5 (Delimiter)
P1: Drive selection ([A-I] Excludes OS drives are excluded and external
drives are available.)
P2: Using user folder (0=OFF, 1=ON)
P3: Using Day folder (0=OFF, 1=ON)
P4: User folder name (String available for folder name) (Can be omitted.)
P5: File name (first 4 (Maximum 4 alphanumeric letters) (Can be omitted.)
characters)
Output Format None
Description An execution error is generated while the recorder is operating. The restriction
for P4 user folder name is applied by PC restrictions only. Setup target will
differ depending on the recorder mode. The description above applies to the
Memory Recorder. Refer to the dedicated storage values of memory filing
storage location. For the HD Recorder, refer to SSS Settings for Storage
Location of HD Recorder. For Multi-Recorder, SSS Settings for Storage
Location of Multi-Recorder. P1 through P5 may be deleted. If values are
deleted, current value is maintained. If all values are omitted, a parameter
error is generated.
SCS (Set Chart Speed) Setting paper feed speed of waveform chart
printing
Function Sets paper feeding speed of waveform chart recording.
Input Format SCS P1, P2 (Delimiter)
P1: Setting speed
P1 Speed value
1-100 Speed numerical value Resolution 1, Recording unit is set
by P2.
E External synchronization recording External synchronization
pulse is set by P2.
P2: Speed unit (When P1=1 to 100) (Can be omitted.)
P2 Speed unit
1 [mm/s]
2 [mm/min]
Omitted [mm/s]
P2: External synchronization pulse ratio (When P1=E) (Can be omitted.)
P2 Sets speed value
1 0.1mm/pulse
2 0.025mm/pulse (Not available in RA2800)
Omitted 0.1mm/pulse
3.5. HD Recording
SRF (Set Real-time Filing) Setting HD recorder basics
Function Sets recording speed, recording length, and recording method.
Input Format SRF P1, P2, P3, P4, P5 (Delimiter)
P1: Recording speed numeric value ([1-1000, E] E=external synchronization)
P2: Recording speed Unit (1=[μs], 2=[ms], 3=[s]) Invalid when P1=E.
P3: Data format (1=Peak, 2=Sampling)
P4: Recording method (1=Normal, 2=Ringing)
P5: Recording data number (Selecting 0 enables the whole “Free Disk
Space”)
Output Format None
Description While the RA2300MKⅡ is operating, an execution error occurs.
The recording speed settings with P2 are: 1s – 100s for RA2300MKⅡ, and
1s – 100s for RA2800A.
The recording speed settings with P1 and P2 are limited from 1us to 10s.
3.7. Trigger
STM (Set Trigger Mode) Setting trigger mode
Function Sets trigger mode.
Input Format STM P1, P2 (Delimiter)
P1: Trigger mode 0=OFF, 1=OR, 2=AND, 4=WINDOW
P1 Trigger mode
0 OFF (memory block=1 block)
1 OR
2 AND
3 <Reserved> A parameter error occurs.
4 WINDOW
P2: <Reserved>
Output Format None
Description While the RA2300MKⅡ is operating, an execution error occurs.
The recorder does not support P1=3(A*B); therefore, a parameter error
occurs when it is selected.
STC (Set Trigger mode OR, AND Channel) Setting OR, AND trigger
condition
Function Sets OR, AND trigger condition.
Input Format STC P1, P2, P3, P4 (Delimiter)
P1: Channel number [1-16] for RA2300MKⅡand [1-32] for RA2800
P2: Detecting ON/OFF 0=OFF, 1=ON
P3: Varies depending on amp type (see below). (Can be omitted.)
P4: Varies depending on amp type (see below). (Can be omitted.)
----- For analog type of amp -----
P3: Trigger level Selecting with measured value
(within the dynamic range).
P4: Slope 1=Rising edge, 2=Falling edge)
----- For event amp -----
P3: Detecting logic 1=AND, 2=OR
P4: Detecting pattern 0=X, 1=H, 2=L
Example: For HHLL XXHL, “11220012”.
Output Format None
Description P1=E1 is a setting for an extra event or the recorder event (E1).
While the RA2300MKⅡ is operating, an execution error occurs.
When the selected channel is an invalid amp, a parameter error occurs.
SCH (Set CHannel) Setting Extra Event or the Recorder Event (E1)
Function Sets extra event (E1).
Input Format SCH P1, P2, P3, P4, P5, P6, P7, P8, P9 (Delimiter)
P1: Selecting channel E1 fixed
P2: Amp type -1 fixed
P3: Input 0=OFF, 1=ON
P4: <Reserved>
P5: Signal ON/OFF 0=OFF, 1=ON The order of all 16 signals is
sig1, 2, 3, to 16 from left.
P6: Signal number [1-16]
P7: EV wavelength 0.0 to 215.0 [mm]
position
P8: Vibration 2.0 to 25.0 [mm]
P9: Width of base line 0.5 to 2.0 [mm]
Output Format None
Description P1 and P2 are fixed.
When the event unit of the recorder is not installed, a mode error occurs.
The vibration (P8) and the width of base line (P9) must be set against all
the signals, regardless of the signal number (P6) designation.
A setting for the wavelength position (P7) becomes the following action,
depending on the signal number (P6) designation.
P6 Action
Signal 8 Used for setting the event wavelength position
Signal 7 Used for calculating the signal-interval pitch based on
a gap of the signal 8 position.
Others Rejected
* “TIP”, “TOP”, or “TCP” command supports the string of a user annotation page.
3.12.System - Maintenance
SDT (Set DaTe) Setting clock
Function Sets the internal clock.
Input Format SDT P1, P2, P3, P4, P5, P6 (Delimiter)
P1: Year (A.D.) (0 – 99) Last two digits
P2: Month (1-12)
P3: Date (1-31)
P4: Hour (0-23)
P5: Minute (0-59)
P6: Second (0-59)
Output Format None
Description The setting of display format of a clock is not supported.
When an invalid date (such as Feb.31) is selected, a parameter error
occurs.
CAUTION
The items that can be set differ depending on the recorder mode. The settings for the invalid
items are rejected.
Example: In the HD Recorder mode, on or off for chart printing is possible,
but HD acquisition cannot be set up because it is fixed to on.
Settings for the HD Recorder are rejected.
SAS (Set Auto Scaling) Sets auto scaling (ON/OFF) ...................................................................... 3-21
SSM (Set Scale Mode) Sets auto scaling mode.............................................................................. 3-21
3.12. System - Maintenance .................................................................................................. 3-22
SDT (Set DaTe) Setting clock .......................................................................................................... 3-22
3.13. Other Settings................................................................................................................ 3-23
STR (Set TRans CH.) Setting real-time transfer channel .............................................................. 3-23
SIM (Set Input Monitor) Setting display speed of input monitor ................................................... 3-23
SAT (Set Auto Transmit) Setting transmit function......................................................................... 3-23
SIF Setup for pause of Input monitor ............................................................................................ 3-24
SIS Setting sync trigger ................................................................................................................... 3-24
SRI Setting data acquisition and printing....................................................................................... 3-24
SBR Setting basic Recording setting ............................................................................................. 3-25
3.14. Compatibility with Older Series .................................................................................. 3-25
SRM (Set Recording Mode) Setting measurement mode .............................................................. 3-25
SAC (Set Auto Copy) Set auto copy ................................................................................................ 3-25
SMI (Set Memory autocopy Icon) Sets auto copy ........................................................................... 3-25
SFI (Set Filing Icon) Sets ON/OFF the filing icon. .......................................................................... 3-26
SYA (Set Y-Axis) Sets Y-axis channels ............................................................................................ 3-26
SMD (Set Memory Division) Setting channel combination ............................................................. 3-26
4.5. HD Recording
4.6.X-Y
ICS (Inquire Chart Speed) Reading HD recording speed of X-Y recorder
Function Outputs HD recording speed of X-Y recorder
Input Format ICS (Delimiter)
Output Format A1, A2 (Delimiter)
A1: Speed numerical value [1-1000] ms
A2: Speed unit Sets sample unit “2=ms”(Fixed)
Description This function is valid in X-Y recorder mode,
In other mode, it becomes the paper feed speed.
4.7. Trigger
ITM (Inquire Trigger Mode) Reading trigger mode
ITC (Inquire Trigger mode OR,AND Channel) Reading OR, AND trigger
condition
Function Outputs the setting of OR, AND trigger condition.
Input Format ITC P1 (Delimiter)
P1: Channel number (For RA2300MKⅡ, 1 through 16, for RA2800A, 1
through 32)
Output Format A1, A2, A3 (Delimiter)
A1: Detecting ON/OFF 0=OFF, 1=ON
A2: Varies depending on amp type (see below).
A3: Varies depending on amp type (see below).
----- For analog type of amp -----
A2: Trigger level Represents with the measurement value.
A3: Slope 1=Rising edge, 2=Falling edge
----- For event amp -----
A2: Detecting logic 1=AND, 2=OR
A3: Detecting pattern 0=X, 1=H, 2=L
Outputs Sig1, Sig2, to Sig8 in the order from left.
Example: For HHLL XXHL, “11220012”.
Description When the selected channel is an invalid amp, a parameter error occurs.
When an error occurs, "?,?,?" is returned.
Description
Description
IAS (Inquire Auto Scaling) Reading auto scaling (ON/OFF) ........................................................... 4-19
ISM (Inquire Scale Mode) Reading auto scaling mode ................................................................... 4-19
4.11. System - Maintenance .................................................................................................. 4-20
IWH (Inquire WHo) Reading version information ............................................................................ 4-20
IDT (Inquire DaTe) Reading clock.................................................................................................... 4-20
4.12. Other Settings................................................................................................................ 4-21
IES (Inquire Error Status) Reading error status.............................................................................. 4-21
IIM (Inquire Input Monitor) Reading display speed of input monitor ............................................ 4-21
IDA (Inquire Input monitor DAta) Reading measurement value of input signal .......................... 4-22
IAT (Inquire Auto Transmit) Reading transmit function .................................................................. 4-22
ICA (Inquire Auto Transmit CAtion) Reading transmit factor ......................................................... 4-23
IIF Reading pause of Input monitor ............................................................................................... 4-23
IIS Reading sync trigger condition.................................................................................................. 4-23
IRI Reading data acquisition and printing condition...................................................................... 4-23
IBR Reading time axis display........................................................................................................ 4-23
4.13. Compatibility with Older Series .................................................................................. 4-24
IRM (Inquire Recording Mode) Reading measurement mode........................................................ 4-24
IAC (Inquire Auto Copy) Reading auto copy .................................................................................... 4-24
IRS (Inquire Rec icon information) Reading recording icon conditions ........................................ 4-24
IMP (Inquire Memory block Point) Reading block No. ................................................................... 4-24
IYA (Inquire Y-Axis) Reading Y-axis channels.................................................................................. 4-25
IMD (Inquire Memory Division) Reading channel combination ...................................................... 4-25
P1 Contents of Initializing
[1-128] Clears the selected memory block.
When the selected number is more than the current
number of block divisions, a parameter error occurs.
A Clears all blocks.
Omitted Clears the current block.
Description Valid only when the RA2300MKⅡ is stopped. Otherwise, an execution error
occurs.
5.3.Auto
EAS (Execute Ac Strain amp balance) Executing auto balance
Function Executing auto balance of ACST amp.
Input Format EAS P1 (Delimiter)
P1: Channel specification [1-16, A] for RA2300MKⅡ, [1-32, A], A means
a batch setting.
Output Format None
Description Executes auto balance of ACST amp.
To execute the auto balance, about 1 second is necessary per channel.
During this command execution, other commands (including [ESC]+C) are not
accepted.
When a channel other than ACST is specified, a parameter error occurs.
5.4.Data Transfer
EIM (Execute Input Monitor data trans) Executing monitor transfer
Function Transfers a screenful of data in the input wavelength monitor.
Input Format EIM (Delimiter)
Output Format A1 (Delimiter)
<Binary data>
A1: Outputs the number of transferred bytes of a line.
“0” means no transmit channel.
“?” means that transmit is disallowed during HD recording.
“*” means that the selected transmit speed beyond the spec disallows
transmission.
When the other values are output, no binary data is output anymore.
<Binary data>: Raw data of the current input signal (A/D value)
Sample: RA2300MKⅡは[STX](D1.DAT)(D2.DAT)(D3.DAT)……(D16.DAT)[SUM]
RA2800Aは[STX](D1.DAT)(D2.DAT)(D3.DAT)……(D32.DAT)[SUM]
Peak:: RA2300MKⅡは[STX](D1.MAX)(D1.MIN)(D2.MAX) ……(D16.MIN)[SUM]
RA2800Aは[STX](D1.MAX)(D1.MIN)(D2.MAX) ……(D32.MIN)[SUM]
[ ]: one byte, ( ):two bytes
Description A screenful of data on the input monitor without any restrictions is transferred
from the RA2300MKⅡ status.
Monitoring signals at remote site with the communication during recording is
enabled.
For monitor speed setting, see “SIM Setting display speed of input monitor”.
The setting of a transfer channel complies with the current amp setting. (The
same as a recording condition)
5.5.Others
EPA (Execute Page Annotation) Executing page annotation print
Function Execute page annotation print.
Input Format EPA (Delimiter)
Output Format None
Description When the RA2300MKⅡ is not operating, a page annotation is printed.
When waveforms are being recorded, a page annotation is printed over the
waveforms.
P1 Initialized settings
1 Initializes setup data for RA2300MKⅡ main unit only
2 Initializes setup data for RA2300MKⅡ main unit and
all memory block
Omitted The same as the case of P=2
CAUTION
Initialization through the ESI command necessitates the restart of the main program, which
forcibly disconnects the communication connection. Accordingly, reconnection is needed after
the initialization. To completely finish the initialization, it needs at least 5 seconds. Allow
sufficient time, and then execute reconnection after performing this command.
CAUTION
In the case of P1 = 1 Not clearing memory block, memory data will be lost if the block size
changes through initialization.
FDS (File Data file Save) Saving memory recording data as file
Function Saves memory recording data as a file.
Input Format FDS P1 (Delimiter)
P1: Saved file name (without extension)
Output Format A1, A2 (Delimiter)
A1: Current folder information
A1 Drive (folder) Information
0 All access possible
1 Read only
2 Change disk
3 Unidentified format
4 No media
5 No drive
6 Other error
A2: Execution information of file saving
A2 Execution Information of File Operation
0 Successful
1 Lack of capacity
2 Write error
3 Read error
4 Illegal characters detected
5 Reserved file name
6 Same file name
7 Other error
Description According to the current setting (block number and copy range), memory
data is saved in a file.
The file is saved in the current folder with the file name selected with P1.
The extension is “FSD”. (Automatically added)
When a file name is selected with an extension: A1=6, A2=7 A parameter
error occurs.
When the block has no data: A1=6, A2=7 An execution error occurs.
When the RA2300MKⅡ is operating: A1=6, A2=7 An execution error
occurs.
8 bits
High-order 4 bits・・・Hexadecimal representation
0 1 2 3 4 5 6 7 A B C D
0 NUL SP 0 @ P ` p ー タ ミ
1 SOH Xon ! 1 A Q a q 。 ア チ ム
2 STX “ 2 B R b r 「 イ ツ メ
Low-order 4 bits -- Hexadecimal representation
3 ETX Xoff # 3 C S c s 」 ウ テ モ
4 EOT DC4 $ 4 D T d t 、 エ ト ヤ
5 ENQ NAK % 5 E U e u ・ オ ナ ユ
6 ACK & 6 F V f v ヲ カ ニ ヨ
7 BEL ‘ 7 G W g e ァ キ ヌ ラ
8 BS CAN ( 8 H X h x ィ ク ネ リ
9 HT ) 9 I Y i y ゥ ケ ノ ル
A LF EOF * : J Z j z ェ コ ハ レ
B VT ESC + ; K [ k { ォ サ ヒ ロ
C FF , < L ¥ l | ャ シ フ ワ
D CR - = M ] m } ュ ス ヘ ン
E SO . > N ^ n ~ ョ セ ホ ゛
F SI / ? O _ o DEL ッ ソ マ ゜
To ensure prolonged use of the product that you have purchased, we offer the following lineup of
maintenance services.
1. Warranty Period
The warranty period for this product is one year from the date of purchase. In case of a failure, the
product will be repaired free of charge (only if the failure is ascribable to the responsibility of A&D).
2. Disclaimers
We take no responsibility for any damages caused by the following reasons;
(1) Consequential damages and production compensation caused by any accidents of our product;
(2) Damages of our product generated by other companies' equipments and their construction;
(3) When operation, proper maintenance, and regular inspection are not done;
(4) Troubles which are apparently not attributable to our company or those that cannot be decided clearly
whether our company is responsible for those troubles;
(5) Exhaustion of consumptions and repair parts;
(6) Troubles attributed to third party's conflicts;
(7) Troubles caused by a force majeure such as natural disasters
Communication Command
RA2000 series INSUTRUCTION Manual (1WMPD4003507)