RDK, project name: TP-73

Bridge name and no: Abutment E1

Title of calculations: Crack width calculation

Revision of calculations: A SLS, crack width check (EC DS)

Prepared by: JAYG Date: 1/25/2025 Revision v005, dated: 4/30/2012

Checked by: HRKN Date: 1/25/2025 Latest use dated: 1/25/2025

Parameters for the section DS/EN 1992-1-1+AC:2008, 7.3.4 with DK NA

Area of concrete effective in tension Ac,eff 56917.33 mm2


Characteristic concrete compression strength fck 40 MPa
Effective concrete tensile stress fct,eff 3.5 MPa
Modulus of elasticity of steel Es 200000 MPa
Short term modulus of elasticity of concrete Ecm 35000 MPa
Modular ratio αe 5.714
k1: 0.8 for high bond bars, 1.6 for plain surface bars k1 0.8
k2: 0.5 for bending, 1.0 for pure tension, (ɛ1+ɛ2)/(2ɛ1) for eccentric tension k2 0.5
k3: Coefficient k3 1.798
k4: Coefficient k4 0.425
Cover to the outer side of the crack reducing reinforcement (no tolerance) c 65 mm
Rebar dia. 1 Rebar dia. 2
Diameter of reinforcement (within Ac,eff) ø1 16 ø2 mm
Number of bars (within Ac,eff) ns1 4 ns2
Reinforcement area (within Ac,eff) As1 804.248 As2 0 mm2
Total area of reinforcing steel As 804 mm2

Design criterias
Maximum allowable compression stress in concrete 24 MPa
Maximum allowable crack width 0.2 mm

Forces & Stresses in section


Short term moment, resulting moment for biaxial bending Mshort 88 kNm
Long term moment, resulting moment for biaxial bending Mlong 30 kNm
Tensile stress in rebar ss 183.24 MPa
Compressive stress in concrete sc 11.97 MPa OK

Results
Equivalent diameter of reinforcement øeq 16 mm
Effective reinforcement ratio rp,eff = As / Ac,eff----- 0.014
Short vs. long time load ratio factor (Short: kt=0.6 and long: kt=0.4) kt 0.549
esm - ecm = [σs - kt (fct,eff/ρp,eff) (1 + αe ρp,eff)] / Es ≥ 0.6 σs/Es----- 0.00055
Maximum crack spacing sr,max = k3 c + k1 k2 k4 ø / ρp,eff----- 309 mm
Crack width wk 0.170 mm OK
The crack width is within the permissible limit

_x000D_ Confidential
#
RDK, project name: <project name>

Bridge name and no: <bridge name & no.>

Title of calculations: <title of calculations>

Revision of calculations: <rev #> SLS, crack width check (EC DS)

Prepared by: <init> Date: <date> Revision v005, dated: 4/30/2012

Checked by: <init> Date: <date> Latest use dated: 1/25/2025

Parameters for the section DS/EN 1992-1-1+AC:2008, 7.3.4 with DK NA

Area of concrete effective in tension Ac,eff 330222 mm2


Characteristic concrete compression strength fck 40 MPa
Effective concrete tensile stress fct,eff 3.5 MPa
Modulus of elasticity of steel Es 200000 MPa
Short term modulus of elasticity of concrete Ecm 42265 MPa
Modular ratio αe 4.732
k1: 0.8 for high bond bars, 1.6 for plain surface bars k1 0.8
k2: 0.5 for bending, 1.0 for pure tension, (ɛ1+ɛ2)/(2ɛ1) for eccentric tension k2 0.5
k3: Coefficient k3 2.142
k4: Coefficient k4 0.425
Cover to the outer side of the crack reducing reinforcement (no tolerance) c 50 mm
Rebar dia. 1 Rebar dia. 2
Diameter of reinforcement (within Ac,eff) ø1 32 ø2 25 mm
Number of bars (within Ac,eff) ns1 14 ns2 0
Reinforcement area (within Ac,eff) As1 11259 As2 0 mm2
Total area of reinforcing steel As 11259 mm2

Design criterias
Maximum allowable compression stress in concrete 18 MPa
Maximum allowable crack width 0.3 mm

Forces & Stresses in section


Short term moment, resulting moment for biaxial bending Mshort 34550 kNm
Long term moment, resulting moment for biaxial bending Mlong 114700 kNm
Tensile stress in rebar ss 170.00 MPa
Compressive stress in concrete sc 16.64 MPa OK

Results
Equivalent diameter of reinforcement øeq 32 mm
Effective reinforcement ratio rp,eff = As / Ac,eff----- 0.034
Short vs. long time load ratio factor (Short: kt=0.6 and long: kt=0.4) kt 0.446
esm - ecm = [σs - kt (fct,eff/ρp,eff) (1 + αe ρp,eff)] / Es ≥ 0.6 σs/Es----- 0.00058
Maximum crack spacing sr,max = k3 c + k1 k2 k4 ø / ρp,eff----- 267 mm
Crack width wk 0.156 mm OK
The crack width is within the permissible limit