Dokumen - Tips - Jhon Deere DTCPDF
Dokumen - Tips - Jhon Deere DTCPDF
OUZXMAG,00018B6 -19-10OCT02-1/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 1/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-2/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 2/27
7/25/2019 Jhon Deere DTC.pdf
Accessing Diagnostic Trouble Codes Turn the key switch to the run position.
Prepare Combine:
OUZXMAG,00018B6 -19-10OCT02-3/27
OUZXMAG,00018B6 -19-10OCT02-4/27
OUZXMAG,00018B6 -19-10OCT02-5/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 3/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-6/27
OUZXMAG,00018B6 -19-10OCT02-7/27
OUZXMAG,00018B6 -19-10OCT02-8/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 4/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-9/27
OUZXMAG,00018B6 -19-10OCT02-10/27
OUZXMAG,00018B6 -19-10OCT02-11/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 5/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-12/27
Control
Unit SPN FMI Pri. Description
A00 91 09 3 Throttle input not valid or not received
A00 94 01 1 Fuel pressure too low - less than 80kPa / 11.6 PSI (9540)
A00 94 03 1 Fuel Pressure Sensor (cc# 131) voltage out of range high - greater than
4 V DC (9640, 9560, 9660, 9580, 9680)
A00 94 04 1 Fuel Pressure Sensor (cc# 131) voltage out of range low. (9640, 9560,
9660, 9580, 9680)
A00 94 10 2 The rail pressure drops too fast when the engine is motoring and the
high pressure pump is off. (9640, 9560, 9660, 9580, 9680)
A00 94 13 1 Fuel Pressure Sensor reading is incorrect. (9640, 9560, 9660, 9580,
9680)
A00 94 17 2 During starting, rail pressure is not developed after a short time
cranking. (9640, 9560, 9660, 9580, 9680)
A00 94 18 2 Fuel pressure too low - less than 100 kPa / 14.7 PSI at low idle (9540)
A00 97 03 2 Water in Fuel Sensor (cc# 136) voltage out of range high (9640, 9560-
Engine Type B, 9660, 9580, 9680)
A00 97 04 2 Water in Fuel Sensor (cc# 136) voltage out of range low (9640, 9560-
Engine Type B, 9660, 9580, 9680)
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 6/27
7/25/2019 Jhon Deere DTC.pdf
A00 105 03 2 Engine Manifold Air Temperature Sensor voltage is out of range high.
The device or wiring is faulty. (9640, 9560, 9660, 9580, 9680)
A00 105 04 2 Engine Manifold Air Temperature Sensor voltage is out of range low.
The device or wiring is faulty. (9640, 9560, 9660, 9580, 9680)
A00 105 16 2 Engine Manifold Air temperature above 88°C / 190°F (moderately
severe level). Maximum power level is derated. Power boost is
disabled.
A00 107 00 2 Air Filter Restricted Switch indicates a plugged air filter.
A00 110 00 1 Engine coolant temperature above 115°C / 240°F (most severe level).
Maximum power level is derated. Power boost is disabled.
A00 110 03 2 Engine Coolant Temperature Sensor voltage is out of range high. The
device or wiring is faulty.
A00 110 04 2 Engine Coolant Temperature Sensor voltage is out of range low. The
device or wiring is faulty.
A00 110 15 2 Engine Coolant Temperature is above 105°C. (9560-Engine Type C)
A00 110 16 2 Engine coolant temperature above 110°C / 230°F for 9640, 9560, 9660,
9580 and 9680 or above 100°C / 212°F for 9540. Maximum power
level is derated. Power boost is disabled.
A00 111 01 1 Coolant level low. Engine coolant temperature above 125°C / 257°F.
Maximum power level is derated. Power boost is disabled.
A00 158 17 2 Controller not powered down properly. (9640, 9560, 9660, 9580, 9680)
Engine fuel temperature is too high (greater than 75°C / 167°F).
A00 174 00 2 Injector pump may be damaged because hot fuel loses its lubrication
properties. (9540)
A00 174 03 2 Engine Fuel Temperature Sensor voltage is out of range high. The
device or wiring is faulty. Injector pump may be damaged because hot
fuel loses its lubrication properties. (9640, 9560, 9660, 9580, 9680)
OUZXMAG,00018B6 -19-10OCT02-13/27
Control
SPN FMI Pri. Description
Unit
A00 174 04 2 Engine Fuel Temperature Sensor voltage is out of range low. The
device or wiring is faulty. Injector pump may be damaged because hot
fuel loses its lubrication properties. (9640, 9560, 9660, 9580, 9680)
Engine fuel temperature above normal range (greater than 65°C /
A00 174 15 2
149°F). Maximum power level and power boost are derated. (9540)
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 7/27
7/25/2019 Jhon Deere DTC.pdf
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 8/27
7/25/2019 Jhon Deere DTC.pdf
A00 652 05 2 The current to Injector #2 is less than expected. (9640, 9560, 9660,
9580, 9680)
A00 652 06 2 The current to Injector #2 increases too rapidly. (9640, 9560, 9660,
9580, 9680)
A00 652 07 2 The fuel flow to cylinder #2 is lower than expected. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
OUZXMAG,00018B6 -19-10OCT02-14/27
Control
SPN FMI Pri. Description
Unit
A00 653 05 2 The current to Injector #3 is less than expected. (9640, 9560, 9660,
9580, 9680)
A00 653 06 2 The current to Injector #3 increases too rapidly. (9640, 9560, 9660,
9580, 9680)
A00 653 07 2 The fuel flow to cylinder #3 is lower than expected. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
A00 654 05 2 The current to Injector #4 is less than expected. (9640, 9560, 9660,
9580, 9680)
A00 654 06 2 The current to Injector #4 increases too rapidly. (9640, 9560, 9660,
9580, 9680)
A00 654 07 2 The fuel flow to cylinder #4 is lower than expected. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
A00 655 05 2 The current to Injector #5 is less than expected. (9640, 9560, 9660,
9580, 9680)
A00 655 06 2 The current to Injector #5 increases too rapidly. (9640, 9560, 9660,
9580, 9680)
A00 655 07 2 The fuel flow to cylinder #5 is lower than expected. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
A00 656 05 2 The current to Injector #6 is less than expected. (9640, 9560, 9660,
9580, 9680)
A00 656 06 2 The current to Injector #6 increases too rapidly. (9640, 9560, 9660,
9580, 9680)
A00 656 07 2 The fuel flow to cylinder #6 is lower than expected. (9640, 9560-
Engine Type B, 9660, 9580)
A00 676 03 2 The Glow Plug Relay output is on when the relay is not energized by
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 9/27
7/25/2019 Jhon Deere DTC.pdf
A00 1077 11 2 The Pump Control Unit senses an abnormal voltage on Pump Power
(cc# 061). (9540)
A00 1077 12 2 The Pump Control Unit detects an error during a self test. (9540)
The Pump Control Unit is not receiving any ECU/CAN messages
A00 1077 19 2
while detecting a signal on Crank Speed Out (cc# 187). (9540)
Injection Pump initiated engine protection due to Diagnostic Trouble
A00 1077 31 1 Code 174.31, 1076.02, 1077.12, 1078.07 or 1078.31. Engine will
derate. (9540)
The Pump Control Unit receives a crank signal from the Engine
A00 1078 07 2 Control Unit that is moderately different than the internal timing within
the Pump. Engine will be derated. (9540)
The Engine Control Unit detects a difference between the internal
A00 1078 11 2
pump timing and engine speed. (9540)
The Pump Control Unit receives a crank signal from the Engine
A00 1078 31 2 Control Unit that is extremely different than the internal timing within
the Pump. Engine will be derated. (9540)
Sensor Supply Voltage 1 (cc# 131) too high (greater than 4.95 V DC).
A00 1079 03 2
(9540)
Sensor Supply Voltage 1 (cc# 131) too low (less than 4.0 V DC).
A00 1079 04 3
(9540)
A00 1080 03 1 Rail Pressure Sensor Power (cc# 721) voltage too high. (9640, 9560,
9660, 9580, 9680)
OUZXMAG,00018B6 -19-10OCT02-15/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 10/27
7/25/2019 Jhon Deere DTC.pdf
Control
SPN FMI Pri. Description
Unit
A00 1080 04 1 Rail Pressure Sensor Power (cc# 721) voltage too low. (9640, 9560,
9660, 9580, 9680)
A00 1080 04 3 Rail Pressure Sensor Power (cc# 721) voltage too low. (9540)
A00 1347 03 1 CC# 178 Shorted to power. (9560-Engine Type C)
A00 1347 05 2 Driver detects problem in circuit to Pump Solenoid 1 Low (cc# 178).
(9640, 9560, 9660, 9580, 9680)
A00 1347 07 2 Rail Pressure Control is unable to match required rail pressure. It may
bee too high or too low. (9640, 9560, 9660, 9580, 9680)
A00 1347 10 2 Pump Solenoid 1 is not delivering expected fuel flow. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
A00 1348 05 2 Driver detects problem in circuit to Pump Solenoid 2 Low (cc# 179).
(9640, 9560-Engine Type B, 9660, 9580, 9680)
A00 1348 10 2 Pump Solenoid 2 is not delivering expected fuel flow. (9640, 9560-
Engine Type B, 9660, 9580, 9680)
Pump Power (cc# 061) is powered when Engine Control Unit is off.
A00 1485 02 2
(9540)
A00 1569 31 2 Engine protection - power derated due to other faults. This code occurs
in conjunction with 105.16, 110.00, 110.03, 110.04, and 110.16. (9640,
9560, 9660, 9580, 9680)
A00 2000 13 1 Engine Control Unit security violation.
OUZXMAG,00018B6 -19-10OCT02-16/27
Control
Unit SPN FMI Pri. Description
C00 158 04 3 Control Circuit Power (cc# 023) is below 10.5 V DC.
C00 170 03 3 CLIMATRAK Cab Air Temperature Sensor voltage too high - greater
than 4.8 V DC. Indicates that the sensor resistance is greater than
60KΩ ( -22°F or -30°C).
C00 170 04 3 CLIMATRAK Cab Air Temperature Sensor voltage too low - less than
0.1 V DC. Indicates that the sensor resistance is less than 50Ω (293°F
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 11/27
7/25/2019 Jhon Deere DTC.pdf
or 145°C).
C00 172 03 3 CLIMATRAK Outside Air Temperature Sensor voltage too high -
greater than 4.8 V DC. Indicates that the sensor resistance is greater
than 60KΩ ( -22°F or -30°C).
C00 172 04 3 CLIMATRAK Outside Air Temperature Sensor voltage too low - less
than 0.1 V DC. Indicates that the sensor resistance is less than 50Ω
(293°F or 145°C).
C00 190 09 3 CAN Bus message missing from Engine Control Unit - Engine Speed
C00 605 04 3 CLIMATRAK Lo Pressure Switch (cc#914) is 12 V DC. A CAN Bus
message from the Left Control Unit indicates that the CLIMATRAK
Hi Pressure Switch (cc#915) is 0 V DC. The CLIMATRAK Hi
Pressure Switch is open or there is a harness problem.
C00 627 03 1 Delayed Power (cc# 006) voltage is above 16 V DC. High voltage
situation must be resolved.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 12/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-17/27
Control
Unit SPN FMI Pri. Description
C00 1506 04 3 HEADERTRAK Rate Adjust voltage is too low - less than 0.5 V
DC. The device or wiring is faulty.
C00 1505 10 3 HEADERTRAK Rate Adjust calibration fault: The potentiometer
was calibrated in the wrong direction or the difference between the
two calibration endpoints is less than 2.00 volts. This diagnostic
trouble code is only displayed during a calibration fault and is not
stored.
C00 1547 03 3 CLIMATRAK Core Temperature Sensor voltage too high - greater
than
101KΩ4.47 V DC.
( -4°F or Indicates
-20°C). that the sensor resistance is greater than
C00 1547 04 3 CLIMATRAK Core Temperature Sensor voltage too low - less than
0.1 V DC. Indicates that the sensor resistance is less than 52Ω
(356°F or 180°C).
C00 1548 03 3 CLIMATRAK Outlet Air Temperature Sensor voltage too high -
greater than 4.8 V DC. Indicates that the sensor resistance is greater
than 60KΩ ( -22°F or -30°C).
C00 1548 04 3 CLIMATRAK Outlet Air Temperature Sensor voltage too low - less
than 0.1 V DC. Indicates that the sensor resistance is less than 50Ω
(293°F or 145°C).
C00 1549 07 3 CLIMATRAK Water Valve position is greater than 30% different
than the commanded position.
C00 200011 03 3 CLIMATRAK Solar Sensor voltage is too high - greater than 4.8 V
DC. The device or wiring is faulty.
C00 200011 04 3 CLIMATRAK Solar Sensor voltage is too low - less than 1.5 V DC.
The device or wiring is faulty.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 13/27
7/25/2019 Jhon Deere DTC.pdf
C00 200017 09 3 CAN Bus message(s) missing from Cornerpost Control Unit.
C00 200018 09 3 CAN Bus message(s) missing from Left Control Unit.
C00 200201 11 3 Separator Engage Switch inputs are incorrect.
C00 200202 11 3 Header Engage Switch inputs are incorrect.
OUZXMAG,00018B6 -19-10OCT02-18/27
Control
SPN FMI Pri. Description
Unit
C03 96 09 3 CAN Bus message missing from Right Control Unit - Fuel Level.
C03 110 09 3 CAN Bus message missing from Engine Control Unit - Engine Coolant
Temperature
C03 190 09 3 CAN Bus message missing from Engine Control Unit - Engine Speed
C03 627 03 3 Delayed Power (cc# 006) voltage out of range high - greater than 16 V
DC.
C03 628 12 1 Controller cannot exit boot block program. Disconnect Cornerpost
Control Unit connector X500. Reconnect connector. Replace
Cornerpost Control Unit if condition persists.
C03 630 11 1 EEPROM failed test at power up. Replace Cornerpost Control Unit if
condition persists.
C03 639 19 3 CAN Bus messages are not being transmitted or received correctly.
Possible effects are none, slow response, or machine down.
C03 1079 03 3 Concave Position Sensor supply voltage high - greater than 5.5 V DC.
C03 1079 04 3 Concave Position Sensor supply voltage low - less than 4.5 V DC.
C03 1486 03 3 Concave Position Sensor voltage is too high - greater than 4.5 V DC.
The device or wiring is faulty.
C03 1486 04 3 Concave Position Sensor voltage is too low - less than 0.5 V DC. The
device or wiring is faulty.
C03 1487 03 3 Dimmer voltage is too high - greater than 4.5 V DC. The device or
wiring is faulty.
C03 1487 04 3 Dimmer voltage is too low - less than 0.5 V DC. The device or wiring
is faulty.
C03 1492 08 3 Cab interior backlighting output transistor detects an open, short, over
voltage, or over temperature condition. The Cornerpost Control Unit
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 14/27
7/25/2019 Jhon Deere DTC.pdf
will turn off the backlighting. The fault condition must be removed
before the backlighting can be turned on.
C03 1493 09 3 CAN Bus message missing from Master Tailings Sensor - Tailings
Volume
C03 1500 11 3 A switch on Cornerpost Display Unit 1 is closed for longer than 30
Seconds.
C03 1501 11 3 A switch on Cornerpost Display Unit 2 is closed for longer than 30
Seconds.
C03 1502 11 3 A switch on Cornerpost Display Unit 3 is closed for longer than 30
Seconds.
C03 1503 09 3 CAN Bus message missing from Armrest Control Unit - Armrest
Switch Status
C03 1510 09 3 CAN Bus message missing from Right Control Unit - Combine
Temperatures
C03 1511 09 3 CAN Bus message missing from Right Control Unit - Grain Loss
C03 1515 09 3 CAN Bus message missing from Header Control Unit - Header Data
C03 1552 03 3 CLIMATRAK Temperature Setpoint Adjust voltage too high - greater
than 4.5 V DC. Device or wiring is faulty.
C03 1552 04 3 CLIMATRAK Temperature Setpoint Adjust voltage too low - less than
0.5 V DC. Device or wiring is faulty.
CLIMATRAK Temperature Setpoint Adjust not calibrated. Refer to
C03 1552 13 3
Diagnostic Address C03-135 for calibration.
C03 1553 03 3 CLIMATRAK Fan Speed Adjust voltage too high - greater than 4.5 V
OUZXMAG,00018B6 -19-10OCT02-19/27
Control
SPN FMI Pri. Description
Unit
C03 1567 09 3 CAN Bus message missing from Header Control Unit - Control
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 15/27
7/25/2019 Jhon Deere DTC.pdf
Mode
C03 100100 09 3 CAN Bus message missing from Left Control Unit - System Data
C03 100101 09 3 CAN Bus message missing from Left Control Unit 2 - System Data
C03 100106 11 3 A switch on Cornerpost Display Unit 4 is closed for longer than 30
Seconds.
Control
SPN FMI Pri. Description
Unit
E00 190 09 3 CAN Bus message missing from Engine Control Unit - Engine Speed
E00 628 12 2 Controller cannot exit boot block program. Turn Key Switch to the
OFF position. Wait 30 seconds. Replace Master Tailings Sensor if
condition persists.
E00 630 11 2 EEPROM failed test at power up. Replace the Master Tailings Sensor
if condition persists.
E00 639 09 3 CAN Bus messages are not received by the Tailings Control Unit in a
timely manner. Possible effects are none, slow response, or machine
down. Other Diagnostic Trouble Codes will indicate the lost message.
E00 639 19 3 CAN Bus messages are not being transmitted or received correctly.
Possible effects are none, slow response, or machine down.
E00 1493 11 3 Tailings system failure. Cause unknown.
E00 1493 15 3 Tailings system calibration is out of range high (sensor detectors are
receiving too little light). Recalibrate. If situation persists, possible
dirty sensor or failed sensor.
E00 1493 17 3 Tailings system calibration is out of range low (sensor detectors are
receiving too much light). Recalibrate. If situation persists, possible
missing elevator paddle or failed sensor.
E00 1494 08 3 Stuck photo receiver detected in Master Tailings Sensor. Clean master
tailings sensor. If condition persists, replace sensor.
E00 1494 11 3 Master Tailings Sensor failure. Cause unknown.
E00 1495 08 3 Stuck photo receiver detected in Slave Tailings Sensor. Clean Slave
Tailings Sensor. If condition continues, replace sensor.
E00 1495 11 3 Slave Tailings Sensor failure. Cause unknown.
E00 1496 07 3 Tailings elevator paddle missing
E00 1511 09 3 CAN Bus message missing from Right Control Unit - Seed Size
E00 1565 09 3 CAN Bus message missing from Armrest Control Unit - Header and
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 16/27
7/25/2019 Jhon Deere DTC.pdf
Separator Engaged
OUZXMAG,00018B6 -19-10OCT02-20/27
Control
SPN FMI Pri. Description
Unit
E01 84 09 3 CAN Bus message missing from Cornerpost Control Unit - Wheel
Speed
E01 190 09 3 CAN Bus message missing from Engine Control Unit - Engine Speed
E01 627 03 1 Controller Supply voltage out of range high - greater than 16 V DC.
E01 628 12 1 Controller cannot exit boot block program. Disconnect Header Control
Unit connector X205. Reconnect connector. Replace Header Control
Unit if condition persists.
E01 630 11 3 System not calibrated or EEPROM failed test at power up. Calibrate
header. Replace the Header Control Unit if condition persists.
E01 639 13 3 Multiple CAN Bus messages have not been received by the Header
Control Unit in a timely manner. Possible effects are no effect, slowed
response, or no response.
E01 1079 03 2 Height Sensor Power (cc# 481) voltage is too high - greater than 5.25
V DC. Height Sensor Power is used to power the Return To Cut
Sensor, Reel Fore/Aft Position Sensor, Deck Plate Position Sensor,
Right HEADERTRAK Sensor, Center HEADERTRAK Sensor and
Left HEADERTRAK Sensor. The voltage regulator of the Header
Control Unit is bad or there is a short in the wiring.
E01 1079 04 2 Height Sensor Power (cc# 481) voltage is too low - less than 4.75 V
DC. Height Sensor Power is used to power the Return To Cut Sensor,
Reel Fore/Aft Position Sensor, Deck Plate Position Sensor, Right
HEADERTRAK Sensor, Center HEADERTRAK Sensor and Left
HEADERTRAK Sensor. The voltage regulator of the Header Control
Unit is bad or there is a short in the wiring.
E01 1080 03 2 Height Sensor Power 2 (cc# 471) voltage is too high - greater than 5.25
V DC. Height Sensor Power 2 is used to power the HEADERTRAK
Angle Sensor and the Header Raise Pressure Sensor. The voltage
regulator of the Header Control Unit is bad or there is a short in the
wiring.
E01 1080 04 2 Height Sensor Power 2 (cc# 471) voltage is too low - less than 4.75 V
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 17/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-21/27
Control
Unit SPN FMI Pri. Description
E01 1522 11 2 Tilt right valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
HEADERTRAK Tilt Right Valve until the fault condition is removed.
E01 1524 11 3 Reel forward valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Reel Forward Valve until the fault condition is removed.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 18/27
7/25/2019 Jhon Deere DTC.pdf
E01 1525 11 3 Reel Aft valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Reel Aft Valve until the fault condition is removed.
E01 1526 11 3 Reel Raise valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Reel Raise Valve until the fault condition is removed.
E01 1527 11 3 Reel Lower valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Reel Lower Valve until the fault condition is removed.
E01 1528 11 3 Drop Rate valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Drop Rate Valve until the fault condition is removed.
E01 1529 11 3 Accumulator Shutoff valve driver detects an open, short, over voltage,
or over temperature condition. The Header Control Unit will not
actuate the Accumulator Shutoff Valve until the fault condition is
removed.
E01 1531 06 2 Reel Speed Increase driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate the
Reel Speed Actuator in the increase speed mode until the fault
condition is removed
E01 1532 06 2 Reel Speed Decrease driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not actuate
the Reel Speed Actuator in the decrease speed mode until the fault
condition is removed
E01 1533 03 2 HEADERTRAK - Return to Cut Sensor (cc# 828) voltage is too high -
greater than 4.5 V DC. Faulty device or wiring.
E01 1533 04 2 HEADERTRAK - Return to Cut Sensor (cc# 828) voltage is too low -
less than 0.5 V DC. Faulty device or wiring.
E01 1534 03 2 Left HEADERTRAK Sensor (cc# 412) voltage is too high - greater
than 4.5 V DC. Faulty device or wiring.
E01 1534 04 2 Left HEADERTRAK Sensor (cc# 412) voltage is too low less than 0.5
V DC. Faulty device or wiring.
E01 1535 03 2 Right HEADERTRAK Sensor (cc# 454) voltage is too high - greater
than 4.5 V DC. Faulty device or wiring.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 19/27
7/25/2019 Jhon Deere DTC.pdf
voltage too high - greater than 4.5 V DC. Faulty device or wiring.
E01 1537 04 3 Reel Fore/Aft Position Sensor or Deck Plate Position Sensor (cc# 834)
voltage too low - less than 0.5 V DC. Faulty device or wiring.
E01 1538 03 3 Reel Height Sensor (cc# 835) voltage too high - greater than 4.5 V DC.
Faulty device or wiring.
E01 1538 04 3 Reel Height Sensor (cc# 835) voltage too low - less than 0.5 V DC.
Faulty device or wiring.
OUZXMAG,00018B6 -19-10OCT02-22/27
Control
Unit SPN FMI Pri. Description
E01 1539 03 3 HEADERTRAK Angle Sensor (cc# 833) voltage too high - greater
than 4.5 V DC. Faulty device or wiring.
E01 1539 04 3 HEADERTRAK Angle Sensor (cc# 833) voltage too low - less than
0.5 V DC. Faulty device or wiring.
E01 1541 02 2 Reel speed unknown.
E01 1544 09 3 CAN Bus message missing from Armrest Control Unit - Multifunction
Lever Switch Status
Control
SPN FMI Pri. Description
Unit
E02 96 03 3 Fuel Level Signal (cc# 652) voltage is too high - greater than 1.96 V
DC. The device or wiring is faulty.
E02 96 04 3 Fuel Level Signal (cc# 652) voltage is too low - less than 0.12 V DC.
The device or wiring is faulty.
E02 627 03 1 Electronic Power (cc# 021) voltage is too high - greater than 16 V DC.
E02 628 12 1 Controller cannot exit boot block program. Turn Key Switch to the
OFF position. Wait for 30 seconds. Replace Right Control Unit if
condition persists.
E02 630 11 2 EEPROM failed test on power up. Replace the Right Control Unit if
condition persists.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 20/27
7/25/2019 Jhon Deere DTC.pdf
E02 639 09 3 CAN Bus messages are not received by the Right Control Unit in a
timely manner. Possible effects are none, slow response, or machine
down. Other Diagnostic Trouble Codes will indicate the lost message
E02 639 19 2 CAN Bus messages are not being transmitted or received correctly.
Possible effects are none, slow response, or machine down.
E02 1498 09 3 CAN Bus message missing from Armrest Control Unit - Header
Engage Status
E02 1500 09 3 CAN Bus message missing from Cornerpost Control Unit - Machine
Configuration
E02 1500 11 3 CAN Bus message from Cornerpost Control Unit invalid - Machine
Configuration
E02 1508 03 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too high -
greater than 4.97 V DC. The device or wiring is faulty.
E02 1508 04 2 Hydraulic Oil Temperature Sensor (cc# 775) voltage is too low - less
than 0.29 V DC. The device or wiring is faulty.
E02 1509 03 2 Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too high -
greater than 4.97 V DC. The device or wiring is faulty.
E02 1509 04 2 Main Gearcase Oil Temperature Sensor (cc# 774) voltage is too low -
less than 0.29 V DC. The device or wiring is faulty.
E02 1510 03 3 Chopper Vane Angle Sensor (cc# 781) voltage is too high (above 4.97
V DC). The device or wiring is faulty.
E02 1510 13 3 Chopper Vane Angle Sensor out of calibration. Perform the calibration
procedure.
E02 1565 09 3 CAN Bus message missing from Armrest Control Unit - Discrete Input
Status
OUZXMAG,00018B6 -19-10OCT02-23/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 21/27
7/25/2019 Jhon Deere DTC.pdf
E03 200129 11 3 The Combine Lower driver detects an open, short, over voltage, or
over temperature condition. The Left Control Unit cannot engage
Combine Lower until the fault condition is removed.
E03 200132 11 1 The Left Brake Light driver detects an open, short, over voltage, or
over temperature condition. Only active in the ROAD mode.
E03 200133 11 1 The Right Brake Light driver detects an open, short, over voltage, or
over temperature condition. Only active in the ROAD mode.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 22/27
7/25/2019 Jhon Deere DTC.pdf
E03 200134 11 1 The Left Marker Light driver detects an open, short, over voltage, or
over temperature condition. Only active in the ROAD mode.
E03 200135 11 1 The Right Marker Light driver detects an open, short, over voltage,
or over temperature condition. Only active in the ROAD mode.
E03 200137 11 2 The Feeder House Reverser driver detects an open, short, over
voltage, or over temperature condition.
E03 200140 03 2 12 V DC detected on Ground (cc# 010) of Control Relay Board.
Indicates problem with ground connections.
OUZXMAG,00018B6 -19-10OCT02-24/27
Control
SPN FMI Pri. Description
Unit
E03 200141 04 2 12 V DC not detected on Unswitched Electronic Power (cc# 022) of
Control Relay Board. Indicates problem with Unswitched Electronic
Power connection, wiring or Fuse F20 of the Engine Compartment
Relay Panel.
E03 200142 04 2 12 V DC not detected on Light Power (cc# 014) of Control Relay
Board. Indicates problem with Light Power connection, wiring or
Fuse F18 of the Engine Compartment Relay Panel.
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 23/27
7/25/2019 Jhon Deere DTC.pdf
Control
SPN FMI Pri. Description
Unit
E04 190 09 3 CAN Bus message(s) missing from Engine Control Unit - Engine
Speed
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 24/27
7/25/2019 Jhon Deere DTC.pdf
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 25/27
7/25/2019 Jhon Deere DTC.pdf
OUZXMAG,00018B6 -19-10OCT02-26/27
Control
SPN FMI Pri. Description
Unit
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 26/27
7/25/2019 Jhon Deere DTC.pdf
A short circuit to ground detected on cc# 393. The Left Control Unit
E04 200337 03 3 2 will not actuate the Right Chaffer Actuator until the fault condition
is removed. (Type B only)
A short circuit to power detected on cc# 393 or 392. The Left
E04 200338 04 3 Control Unit 2 will not actuate the Right Chaffer Actuator until the
fault condition is removed. (Type B only)
A short circuit to ground detected on cc# 392. The Left Control Unit
E04 200339 03 3 2 will not actuate the Right Chaffer Actuator until the fault condition
is removed. (Type B only)
A short circuit to ground detected on cc# 395. The Left Control Unit
E04 200340 03 3 2 will not actuate the Right Sieve Actuator until the fault condition
is removed. (Type B only)
A short circuit to power detected on cc# 395 or 394. The Left
E04 200341 04 3 Control Unit 2 will not actuate the Right Sieve Actuator until the
fault condition is removed. (Type B only)
A short circuit to ground detected on cc# 394. The Left Control Unit
E04 200342 03 3 2 will not actuate the Right Sieve Actuator until the fault condition
is removed. (Type B only)
A short circuit to ground detected on cc# 389. The Left Control Unit
E04 200343 03 3 2 will not actuate the Right Precleaner Actuator until the fault
condition is removed. (Type B only)
A short circuit to power detected on cc# 389 or 388. The Left
E04 200344 04 3 Control Unit 2 will not actuate the Right Precleaner Actuator until
the fault condition is removed. (Type B only)
A short circuit to ground detected on cc# 388. The Left Control Unit
E04 200345 03 3 2 will not actuate the Right Precleaner Actuator until the fault
condition is removed. (Type B only)
E04 200352 11 3 Chaffer Actuators not calibrated. (Type B only)
E04 200353 11 3 Sieve Actuators not calibrated. (Type B only)
E04 200354 11 3 Precleaner Actuators not calibrated. (Type B only)
OUZXMAG,00018B6 -19-10OCT02-27/27
http://slidepdf.com/reader/full/jhon-deere-dtcpdf 27/27