www.newtork.co.

kr

MULTITURN / PARTTURN

INTELLIGENT

ELECTRIC
ACTUATOR
NEWTORK KOREA
THE WORLD LEADER
IN ACTUATION SOLUTION
ALL ABOUT ELECTRIC ACTUATORS

TABLE OF CONTENTS
01. INTRODUCTION
02. INDUSTRIES
03. PRODUCT CATEGORY
04. DESIGN
05. SPECIFICATION
06. FUNCTION
07. CONTACT and COMMUNICATION
08. STRUCTURE
09. PERFORMANCE DATA
10. DIMENSION
11. WIRING DIAGRAM
12. CERTIFICATION
13. CUSTOMER SUPPORT and SITE SERVICE
INTRODUCTION

NEWTORK KOREA was founded by engineers with more than 20years experience in the
valve industry. For more than 10 years, we have manufactured and supplied electric actuators,
functional control devices for plant fluid management and we are certified to ISO 9001:2015,
ISO 14001:2015, and OHSAS 18001:2007 quality assurance standard.

NEWTORK KOREA has in-depth experience in retrofit and the strength to deliver on-site
service that even covers products of other makers. With the expertise to advise on national
standard enactment of electric actuators, NEWTORK KOREA is developing next-generation
products to reduce the burden on customers and increase convenience.

As a leader in actuation solutions, NEWTORK KOREA's prime goal is to provide efficient and
economical solutions to customers through continuous efforts, excellent technology, and long-term
expertise, ultimately to advance as a business partner that helps drive customer growth.

NEWTORK KOREA will continue to grow steadily based on user trust as it strives to become
the first choice for customers. Based on world-class technology, cost competitiveness, high
quality, prompt accurate service, and thorough follow-up management, we promise to provide
stability and differentiated technical support for our customer’s plants.

INDUSTRIES

WATER & SEWAGE POWER PLANT OIL & GAS PETROCHEMICAL PLANT

DAM SHIPYARD NUCLEAR ENERGY

02 / 03
PRODUCT CATEGORY

NEWTORK ELECTRIC ACTUATOR

Multi-turn Part-turn

ON-OFF / INCHING MODULATING ON-OFF / INCHING ON-OFF / INCHING MODULATING MODULATING

NTI NTIM NTIT NTIR NTITM NTIRM


Series Series Series Series Series Series

NTI NTIT NTIR


(Multi-turn) (Part-turn) (Part-turn)
NEWTORK KOREA CO., LTD.

04
DESIGN

Non-interference design
To prevent penetration of dirt and humidity in the field, design was applied to overcome the shortcomings of the
non-interference design is adopted which can be set previously used potentiometer, with its lack of durability
by infrared remote control without opening the cover. and short lifespan, and to promote product reliability.
In order to avoid penetration of very fine foreign matter This encoder has a setting range from 2.5 revolutions
during use in the field, the unit is generally designed up to 150,000 revolutions, with an optional 24-bit optical
with hole magnetic sensor technology, abandoning the encoder.
product's field operation method through the shaft.

Highly reliable electronic system


Enclosure
The embedded electronic system uses an innovative, 32-bit
As a double sealed water-proof structure, NTI and NTIT system on a Chip (SOC) with built-in multifunctional circuits
series are based on IP68 (15m, 90 hours) and NTIR as well as robust computability. This system includes
series are based on IP67. Explosion-proof products essential electronic circuits, e.g. Logic board, Interface
(only NTI series) is based on Ex d IIC T4 complied with board, components of electronic components except
IEC60079-0:2011, IEC60079-1:2014 and it is optional. complicated electrical connections, and very convenient
Since the terminal block and the electrical control unit electronic control devices including limit switch and
are separated, the internal electrical control unit can be torque switch.
completely water- and dust-proof even if the terminal
block cover is opened for wiring.
High-definition LCD
Equipped with a high definition LCD with wide viewing
Accurate torque measurement
angle, large display window, and backlight, it is designed
The precise torque value is measured by converting the to provide users with easy checking of valve opening,
repulsive power of the motor shaft transmitted by the torque, and function status from a distance. In addition,
pressure sensor into an electronic signal. A pressure the LCD is protected by a tempered glass window.
sensor (strain gauge) is used to measure torque quickly
and accurately during output and a torque measurement
system is used to check change of torque in the LCD Backup battery
window, in addition to a reliable overload prevention
The built-in backup battery demonstrates the state of
system. The problem of torque value deviation caused
the valve and valve position on the display window for
by mechanical gear efficiency change can also be
smooth manual operation even when the power supply
solved by this torque detection system.
is turned off. When manual operation is completed,
the circuit is shut off automatically to conserve battery
power. If the power is connected to the product or the
Precise position measurement
power supply is interrupted and manual operation is not
A progressive hole incremental encoder is used for performed, the backup battery will not consume power,
valve position measurement. The non-contact encoder so the lifespan will last for an average of five years.
www.newtork.co.kr

05
SPECIFICATION

Life Cycle
When operating on-off with rated torque, the minimum Separated control should be used where there is excessive
lifecycle is 30,000 cycles with Open/Close /Open cycle. vibration equipment. Alternatively, the product should be
This is based on the average of the maximum setting installed away from the valve, equipped with a vibration
torque at the stroke end and 1/3 of the maximum setting -absorbing coupling and operated by an extended shaft.
torque during the stroke.
Noise
Life Test Noise measurement does not exceed 61dB(A) within 1M.
Lifetime test of standard product is based on 10,000
cycles with open/close/open as one cycle. It is based on Material
the average value of 3/1 of the maximum setting torque
All products of NTI, NTIT, and NTIR series are made of
at the stroke end (500,000 output rotation) and the
light and corrosion-resistant aluminum.
maximum setting torque during stroke.

Paint
Temperature
Polyester powder coating is used and the body is
The possible operating temperature is -30°C to +70°C. RAL9006, which is light gray and RAL9005, the hand
Basically, the operating temperature must be within the wheels and hand lever are black.
temperature range indicated on the certificate. Same
operating temperature as above for explosion-proof
Lubricant
products (only NTI series).
The drive gear is filled with lubricant. Lubricant is used
Load operation cycle semi-permanently. while NTI and NTIT series use GL-5
75W/90, NTIR series use 0# semi-liquid grease and
The load operation cycle of the motor is as follows : capacity are as follows.
• ON-OFF Rating : S2-15 / Minutes : 60 start/hr
MODEL CAPACITY
• MODULATING rating : S4–30 / Minutes : 1200 start/hr NTI-01
NTI-02 0.3 L
NTI-03
Vibration NTI-04
0.8 L
NTI-05
The vibration of the standard type product does not NTI-06 1.1 L
exceed the following standard values. NTI-07 6.5 L

• Equipment introduction NTI-08


NTI-09 and NTI-09.1 7.0 L
The cumulative vibration value in the 10-1,000 MHz
NTI-10 and NTI-10G
frequency range is less than 1gms. NTIT-01

• Impact NTIT-02

The maximum acceleration is 5g. NTIT-03


1.5 L
NTIT-04
• Earthquake NTIT-05
If the unit is still running after an accident or during an NTIT-06

accident, the frequency range is 150Hz and acceleration NTIR-200


400 g
is 2g. If structural integrity is required, this is 5g. NTIR-500
NEWTORK KOREA CO., LTD.

06
FUNCTION

The NTI series has strong self-protection capability.


If incorrect operation is input by the user or abnormality is detected in the product, the NTI protects or corrects itself.

Torque detection function circuit and displays warning to prevent overheating and
damage to the motor.
If the valve is in a process that restricts obstruction or
operation, the function detects when a torque greater
than the existing setting value occurs. Surge protector
It is the function to protect the main board from the
Torque switch bypass external surge voltage which can flows through a
terminal of the product by the built-in surge protector.
When starting the motor or if the valve is stuck, stall
torque of 1.4 - to 2-times higher than the rated torque of
the product is provided. Overheating of motor
There are two thermostats in the winding section of
Foreign substance removal the motor to sense temperature. The thermostats
interrupt the contact when the motor reaches a certain
If the torque switch bypass function does not resolve temperature during operation, stopping operation of the
interference when the torque detection function is product and displaying a warning signal on the display
activated, stop operation of the product, reverse the or remotely reporting the status. When the motor has
direction by approximately 10%, and remove foreign cooled, it will be reset automatically to be reactivated.
matter using fluid pressure. Depending on user settings,
this function can be set up to 10 times to protect the
product from Anti-Hammer. Error detection
A function to help the user diagnose problems by automatically
Valve jammed protection detecting error of internal control systems and displaying
related information on the display window.
If the jam cannot be resolved by the foreign matter
removal function, the command will not be implemented
Instantaneous reverse protection
in the direction of the problem. Stop operation, display
warning signals and real-time torque value on the If an instruction in the opposite direction is input when
display window to prevent valve damage. the product is rotating, the internal operating circuit
will stop operation for 300ms before implementing this
Auto-syncrophase command. This technology reduces damage to the
motor's overcurrent, extending the life of the reverse
It has a function that distinguishes the phase circuit contactor and protecting mechanical devices, e.g. valve
when power is supplied. Therefore, even if three-phase stem or gearbox, which can be damaged by impact.
power is connected, it rotates accurately in the direction
matching the control signal. This function prevents the
Position transmitter
product from damage due to incorrect wiring.
It has built-in function to output 4-20mA so that valve position
can be checked accurately in the central control room.
Lost Phase
The phase correction circuit monitors the continuous ESD
supply of three-phase power and prevents overheating
of the three-phase motor when open-phase occurs. If This function moves the valve to the safe position set by the
one or multiple phases is open-phase, it protects the user. This function takes precedence over other existing
product by preventing motor operation from the operation local and remote control signals.
www.newtork.co.kr

07
CONTACT & COMMUNICATION

Indication & Monitoring Contacts


Analogue signal Input impedance
It has four contact points (eight contact points as an
option) with contact capacities of 250VAC 5A and 0-5mA 1K

30VDC 5A. All status contacts can be displayed as 0-10mA 500

Normal Open and Normal Close according to user's 0-20mA 250


request. Users can choose from 27 different functions 4-20mA 250
including Full Open and Full Close, and protection 0-5V 1M
or warning, all of which can easily be changed by 0-10V 78K
remote control. Apart from the four status contacts, the 0-20V 52K
monitoring contacts are 250VAC5A, 30VDC 5A and can
effectively display electronic devices of the product.
Item Trigger Conditions
Monitor relay operate on phenomena, such as losing-
phase, control power failure, selecting local control and 1 In valve closing limit position

selecting local stop. 2 In valve opening limit position


3 Middle position

Analogue Modulating Control (Option) 4 Torque protection is active when closing valve
5 Torque protection is active when opening valve
Modulating controller automatically calculates product
6 Torque protection is active during the stroke
and valve position in proportion to the analog current or
voltage signal. The input proportional control signal is 7 Torque is a active at any position

transmitted to the modulating controller through a Liner 8 Actuator is closing


Isolator. The controller converts the valve position signal 9 Actuator is opening
to the proportional value by comparing the current 10 Actuator is output rotating
valve position with the product position discrepancy. 11 Motor stalled protection
By adjusting the dead zone and running time control of 12 Low battery
the modulating controller, unnecessary reciprocating
13 Manual operation of actuator
movement of the valve can be prevented.
14 Effective valve opening interlocking signal
15 Effective valve closing interlocking signal
Fieldbus Control Function (Option)
16 Effective interlocking signal
The Fieldbus Mastering Control System is compatible 17 Effective ESD signal
with communication protocol. All products of NTI, NTIT, and 18 Iosing phase power
NTIR series can add Modbus, Profibus and Foundation
19 Selecting local stop
Fieldbus with the Fieldbus module.
20 Selecting local control
21 Selecting remote control
Remote Indication of Valve Position
22 Actuator alarm
NEWTORK KOREA CO., LTD.

The Current Transmitter is a 4-20mA current delivery 23 24V power failure


signal, and even the finest matching signals can change 24 Motor running
the position of the current valve by selecting Full 25 Valve alarm
Open or Full Close. In addition, the maximum external
26 Temperature protection is active
impedance value in the rated voltage is 500 Ω, and the
27 Control alarm
error among the total stroke length is less than 1%.

08
NTI / NTIT INTERNAL STRUCTURE

2 1

5
3

1 Body
As the handwheel and center column are connected and
rotated 1:1, the manual operation time is shortened, which NTI Series
is useful during urgent operations. Motor shafts and worm It is used for multi-turn valves, e.g.globe valve, gate valve, and water
gate and can also be used for part-turn valves in combination with
shafts are separated to allow quick and easy replacement. a gear box. It is a smart product which has 30-3500Nm torque range.
Worm gears and worm shafts are immersed in oil so that
they are not affected by temperature changes.
NTIT Series
2 Motor
The product is for ball valves, butterfly valves, and other part-turn valves.
The motor is a class F insulation grade, designed using Torque range is 100-2000Nm, with perfect functionality and reliable quality.
special software to enable the product to operate normally
under worst-case conditions. When the actuator is stop,
the motor that outputs high torque with low inertia reaches records valve position without a battery when the power is off.
maximum torque immediately upon starting and minimizes
overrun. In addition, the built-in temperature sensor 6 Local Control
prevents tripping and fire damage if the motor overheats at The local control switch and operation switch are magnetic
a certain temperature (132°C). switches. Since moisture penetration is prevented through
tight sealing, the product is controlled by the inner
3 Terminal Block magnetic reed switch instead of fastening the switch shaft
The terminal block consists of 48 connecting elements in a through the cover.
screw type. To protect the internal electronic components
when the terminal block cover is opened for field wiring, it 7 Display Window
is designed as an independent double sealing structure. The valve position change is indicated in the display
window in 1% increments. The receiver is mounted in a
4 Base sealed display window so you can diagnose and set the
A thrust bearing on the base reduces all frictional forces to product without opening the cover with the infrared remote
ensure the body is not affected. The NTI-06 and lower control. The operating distance of this remote control is
models and the NTIT series are equipped with a lubed, 0.75M.
detachable type A base that allows the product to be
removed without changing the position of the valve. The base 8 Manual Operation
of NTI-07 and above models is located inside the product. The product can be operated manually in an emergency
Therefore, the bush can easily be separated and processed. using the handwheel. Handwheel design is adopted as it
is suitable for efficient manual operation and is designed
PCB to facilitate manual operation using the 'Hammer Blow
www.newtork.co.kr

5
The hole incremental encoder has been introduced to measure effect' with a half-wheel clearance. It also includes a
valve position, thereby improving accuracy of the existing manual/automatic clutch, which is a locking device for safe
potentiometer. This optical encoder is optional and accurately operation even when the motor is running.

09
NTIR INTERNAL STRUCTURE

1
4

5
6

10 8

NTIR Series
It is used for small part-turn valves and has a torque range
of 50-500Nm, which features a sophisticated design and
competitive price.

1 Display Window 6 Power board


The Dot Matrix LCD with a blue background shows The power board is equipped with electronic parts
the status screen clearly. used for motor power supply and all other parts.

2 Main board 7 Manual operation


With the application of reliable SOC systems, the The handwheel used when the power supply is cut
product detects faults and checks self-protection and off is equipped with the NTIR-200 lever type or NTIR-
information based on the circuit design that includes 500 circular type, depending on motor capacity, a
all functions. clutch is included which is used when switching to manual
operation.
3 Valve position control
A complete hole encoder operated by the main shaft
8 Worm and Worm shaft
precisely measures the valve position. The two-stage worm gear with high gear ratio has low
noise of up to 50dB and self-locking functionality.
4 Button 9 Base
Set various functions using four kinds of buttons, According to ISO 5211, bushings can be processed
including control, opening, and closing.
NEWTORK KOREA CO., LTD.

according to user requirements.

5 Motor 10 Terminal block


High-power low inertia type F squirrel motor features The double-sealing terminal block protects internal
enamel insulation and two temperature sensing electronic components from external hazardous
switches. gases during field wiring.

10
NTI PERFORMANCE DATA

NTI SERIES (380V / 3Ph)


Flange RPM Torque Rated Current (A) Motor Rated Power(KW) Weight
Model (ISO 5210) 50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
18 21 45 1.47 1.53 0.47 0.55 32
24 29 45 1.48 1.55 0.50 0.56 32
36 43 35 1.50 1.57 0.51 0.57 32
NTI-01 F10
48 57 35 1.60 1.60 0.52 0.58 32
72 86 35 1.90 1.86 0.85 0.86 32
96 115 30 2.00 2.05 0.87 0.89 32
18 21 80 1.66 1.70 0.53 0.60 32
24 29 80 1.70 1.73 0.54 0.61 32
36 43 80 1.72 1.77 0.55 0.63 32
NTI-02 F10
48 57 80 1.75 1.82 0.55 0.64 32
72 86 45 2.20 2.30 0.92 1.00 32
96 115 40 2.30 2.35 0.93 1.06 32
18 21 110 1.86 1.85 0.60 0.63 32
NTI-03 F10
24 29 110 1.95 1.92 0.62 0.65 32
18 21 250 3.90 3.95 1.75 1.82 52
24 29 250 4.10 4.15 1.80 1.85 52
36 43 205 4.20 4.24 1.84 1.95 52
NTI-04 F14 48 57 205 4.30 4.36 1.90 1.97 52
72 86 160 3.00 3.50 1.70 1.80 52
96 115 145 3.10 3.60 1.72 1.85 52
144 173 100 5.20 5.40 2.50 2.56 52
18 21 450 5.40 5.50 1.96 2.02 52
24 29 450 5.50 5.60 2.00 2.09 52
36 43 300 5.60 5.80 2.05 2.11 52
NTI-05 F14 48 57 240 5.90 6.10 2.12 2.20 52
72 86 240 5.70 6.00 2.25 2.48 52
96 115 230 6.60 8.00 2.60 3.30 52
144 173 150 6.30 6.60 2.90 3.00 52
18 21 650 7.20 7.50 3.00 3.20 75
24 29 650 7.60 7.80 3.20 3.40 75
36 43 542 7.74 8.00 3.32 3.50 75
NTI-06 F16 48 57 450 13.50 14.60 5.06 5.12 75
72 86 450 12.50 12.80 4.92 4.90 75
96 115 365 13.20 13.50 4.98 4.91 75
144 173 270 13.00 14.50 4.96 5.11 75
18 21 1100 11.00 11.50 5.20 5.30 200
24 29 1100 12.00 12.60 5.30 5.40 200
36 43 780 12.30 13.00 5.35 5.46 200
NTI-07 F25
48 57 680 15.80 16.50 7.50 8.20 200
72 86 550 16.60 17.30 8.10 8.60 200
96 115 550 17.80 18.20 8.70 9.10 200
18 21 1500 10.50 11.50 5.70 5.90 230
24 29 1500 12.60 13.80 6.00 6.80 230
36 43 1300 13.80 15.00 6.80 7.30 230
NTI-08 F30
48 57 1000 19.00 20.00 9.48 9.67 230
72 86 800 19.50 21.00 9.60 9.88 230
96 115 745 21.00 22.00 9.95 10.00 230
18 21 2000 18.50 19.50 8.50 9.50 230
24 29 2000 20.00 21.00 9.60 9.80 230
36 43 1700 22.00 23.00 10.00 11.00 230
NTI-09 F30
48 57 1350 21.00 22.00 9.70 10.00 230
72 86 1100 23.00 24.00 11.00 11.20 230
96 115 1000 25.00 26.00 11.60 12.20 230
24 29 2500 25.00 26.00 13.00 12.60 230
NTI-09.1 F30
36 43 2500 26.00 26.50 13.60 12.80 230
NTI-10 F30 24 21 3000 29.00 33.00 14.00 14.50 230
18 21 3500 30.00 34.00 14.20 14.90 230
24 29 3500 32.00 36.00 14.50 15.80 230
www.newtork.co.kr

36 43 2000 29.00 32.00 13.80 14.20 230


NTI-10G F30
48 57 1600 31.00 33.00 15.00 16.80 230
72 86 1400 32.00 34.00 15.60 17.30 230
96 115 1200 33.00 35.00 16.20 18.00 230

11
NTI PERFORMANCE DATA

NTIM SERIES (380V / 3Ph)


RPM Torque (Nm) Rated Current (A) Motor Rated Power (KW) Weight
Model
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz kg
18 21 50 50 1.46 1.52 0.46 0.49 32
24 29 50 50 1.50 1.58 0.48 0.52 32
NTIM-02 36 43 50 50 1.53 1.62 0.49 0.54 32
F10 48 57 40 40 1.60 1.71 0.50 0.58 32
72 86 25 25 2.00 2.10 0.78 0.92 32
18 21 90 90 1.65 1.62 0.55 0.56 32
NTIM-03
24 29 90 90 1.68 1.75 0.57 0.62 32
18 21 180 180 3.50 3.80 1.82 1.83 52
24 29 180 180 3.75 3.96 1.88 1.86 52
NTIM-04 36 43 125 125 3.90 4.17 1.92 1.92 52
48 57 125 125 4.00 4.25 1.96 1.98 52
72 86 80 80 3.00 3.30 1.80 1.78 52
F14
18 21 360 360 4.00 4.10 1.95 1.90 52
24 29 360 360 4.10 4.16 2.06 1.98 52
NTIM-05 36 43 240 240 4.18 4.23 2.12 2.04 52
48 57 200 200 4.26 4.41 2.24 2.08 52
72 86 140 140 4.50 4.80 2.42 2.30 52
18 21 600 480 7.80 6.20 3.30 3.06 75
24 29 600 480 8.30 6.40 3.34 3.15 75
NTIM-06 F16 36 43 300 300 6.50 6.80 3.36 3.24 75
48 57 260 260 6.30 6.60 3.34 3.32 75
72 86 220 220 6.50 6.90 3.45 3.49 75

NTI SERIES (220V / 1Ph)


RPM Torque Rated Current (A) Actuator Rated Power (KW) Weight
Model
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
18 21 65 2.30 2.10 0.35 0.37 32
NTI-03 F10
24 29 60 2.30 2.10 0.35 0.37 32
18 21 165 6.70 7.50 0.90 1.10 52
24 29 140 6.70 7.50 0.90 1.10 52
36 43 120 6.70 7.50 0.90 1.10 52
NTI-04
48 57 70 6.70 7.50 0.90 1.10 52
72 86 60 9.00 9.80 1.40 1.60 52
96 115 50 9.00 9.80 1.40 1.60 52
F14
18 21 200 8.00 8.30 1.20 1.30 52
24 29 200 8.00 8.30 1.20 1.30 52
36 43 150 8.00 8.30 1.20 1.30 52
NTI-05
48 57 80 8.00 8.30 1.20 1.30 52
72 86 70 11.50 12.70 1.60 1.90 52
96 115 60 11.50 12.70 1.60 1.90 52
18 21 400 12.60 14.00 2.00 2.25 75
NEWTORK KOREA CO., LTD.

24 29 350 12.60 14.00 2.00 2.25 75


36 43 300 12.60 14.00 2.00 2.25 75
NTIM-06 F16
48 57 270 12.60 14.00 2.00 2.25 75
72 86 200 16.00 19.00 2.60 2.80 75
96 115 170 16.00 19.00 2.60 2.80 75

12
NTI PERFORMANCE DATA

NTIM SERIES (220V / 1Ph)


RPM Torque Rated Current (A) Motor Rated Power (KW) Weight
Model
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
18 21 40 1.80 1.90 0.34 0.35 32
NTIM-03 F10
24 29 40 1.80 1.90 0.34 0.35 32
18 21 100 6.40 7.30 0.92 1.05 52
24 29 85 6.40 7.30 0.92 1.05 52
NTIM-04 36 43 70 6.40 7.30 0.92 1.05 52
48 57 50 6.40 7.30 0.92 1.05 52
72 86 40 8.20 10.00 1.43 1.65 52
F14
18 21 120 7.20 7.60 1.24 1.32 52
24 29 120 7.20 7.60 1.24 1.32 52
NTIM-05 36 43 90 7.20 7.60 1.24 1.32 52
48 57 60 7.20 7.60 1.24 1.32 52
72 86 50 9.60 11.00 1.63 1.73 52
18 21 240 11.30 13.00 2.23 2.30 75
24 29 210 11.30 13.00 2.23 2.30 75
NTIM-06 F16 36 43 180 11.30 13.00 2.23 2.30 75
48 57 160 14.50 18.00 2.67 2.85 75
72 86 140 14.50 18.00 2.67 2.85 75

Mechanical Interface Size


NTI NTI-07 NTI-08 NTI-09
Model NTI - 04/05 NTI - 06
- 01/02/03 NTI-09.1 NTI-10 NTI-10G
ISO 5210 F10 F14 F16 F25 F30
Flange
Mss sp-102 FA10 FA14 FA16 FA25 FA30
STEM ACCEPTANCE DIAMETER
Rising mm 32 38 54 70 83
A Type
Non-rising mm 26 32 45 60 73

Rising mm - 51 67 - -
Z Type
Non-rising mm - 38 51 - -

B4 Type Non-rising mm 26 32 45 60 73

NTIT
Model NTIT - 01 NTIT - 02 NTIT - 03 NTIT - 06 NTIR - 200 NTIR - 500
- 04 / 05
ISO 5210 F07 F07 / F10 F10 F12 / F14 F14 F05 / F07 F07 / F10
Flange
Mss sp-102 FA07 FA07 / FA10 FA10 FA12 / FA14 FA14 FA05 / FA07 FA07 / FA10
STEM ACCEPTANCE DIAMETER
Key mm 28 28 / 42 42 50 / 60 60 22 33

Square mm 19 19 / 27 27 32 / 36 36 15 23
www.newtork.co.kr

13
NTIT PERFORMANCE DATA

NTIT SERIES (380V / 3Ph)


Stem Dia (mm) 90°time (s) Torque Rated Current (A) Motor Rated Power (KW) Weight
Model
Key Square 50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
NTIT-01 F07 28 19 18-20 16-18 125 0.47 0.50 0.13 0.17 24
F07 28 19 18-20 16-18 250 0.49 0.56 0.13 0.17 24
NTIT-02
F10 42 27 18-20 16-18 250 0.49 0.56 0.13 0.17 24
NTIT-03 F10 42 27 26-30 19-22 500 0.53 0.59 0.14 0.18 35
F12 50 32 27-30 23-26 1000 0.56 0.62 0.14 0.18 35
NTIT-04
F14 60 36 27-30 23-26 1000 0.56 0.62 0.14 0.18 35
F12 50 32 46-50 42-45 1500 0.60 0.65 0.15 0.19 35
NTIT-05
F14 60 36 46-50 42-45 1500 0.60 0.65 0.15 0.19 35
NTIT-06 F14 60 36 58-60 45-50 2000 0.62 0.69 0.15 0.19 35

NTITM SERIES (380V / 3Ph)


Stem Dia (mm) 90°time (s) Torque Rated Current (A) Motor Rated Power (KW) Weight
Model
Key Square 50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
NTIT-01 F07 28 19 18-20 16-18 125 0.42 0.45 0.12 0.16 24
F07 28 19 18-20 16-18 215 0.45 0.48 0.12 0.16 24
NTIT-02
F10 42 27 18-20 16-18 215 0.45 0.48 0.12 0.16 24
NTIT-03 F10 42 27 26-30 19-22 300 0.50 0.53 0.13 0.17 35
F12 50 32 38-40 23-26 700 0.53 0.58 0.13 0.17 35
NTIT-04
F14 60 36 38-40 23-26 700 0.53 0.58 0.13 0.17 35
F12 50 32 46-50 42-45 1100 0.57 0.61 0.14 0.18 35
NTIT-05
F14 60 36 46-50 42-45 1100 0.57 0.61 0.14 0.18 35
NTIT-06 F14 60 36 58-60 45-50 1500 0.60 0.66 0.14 0.18 35

NTIT SERIES (220V / 1Ph)


Stem Dia (mm) 90°time (s) Torque Rated Current (A) Motor Rated Power (KW) Weight
Model
Key Square 50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
NTIT-01 F07 28 19 14-16 13-15 100 1.60 1.70 0.25 0.26 24
F07 28 19 18-20 16-18 200 1.60 1.70 0.25 0.26 24
NTIT-02
F10 42 27 18-20 16-18 200 1.60 1.70 0.25 0.26 24
NTIT-03 F10 42 27 18-20 16-18 400 1.86 1.98 0.28 0.30 35
F12 50 32 25-30 19-22 800 1.86 1.98 0.28 0.30 35
NTIT-04
F14 60 36 25-30 19-22 800 1.86 1.98 0.28 0.30 35
F12 50 32 27-30 23-26 1200 1.70 1.92 0.27 0.29 35
NTIT-05
F14 60 36 27-30 23-26 1200 1.70 1.92 0.27 0.29 35
NTIT-06 F14 60 36 58-62 45-50 1600 1.70 1.92 0.27 0.29 35

NTIM SERIES (220V / 1Ph)


Stem Dia (mm) 90°time (s) Torque Rated Current (A) Motor Rated Power (KW) Weight
Model
Key Square 50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz kg
NTIT-01 F07 28 19 14-16 13-15 100 1.50 1.65 0.26 0.27 24
F07 28 19 18-20 16-18 150 1.50 1.65 0.26 0.27 24
NTIT-02
F10 42 27 18-20 16-18 150 1.50 1.65 0.26 0.27 24
NTIT-03 F10 42 27 18-20 16-18 200 1.70 1.85 0.28 0.30 35
NEWTORK KOREA CO., LTD.

F12 50 32 25-30 19-22 600 1.70 1.85 0.28 0.30 35


NTIT-04
F14 60 36 25-30 19-22 600 1.70 1.85 0.28 0.30 35
F12 50 32 27-30 23-26 1000 1.60 1.76 0.27 0.29 35
NTIT-05
F14 60 36 27-30 23-26 1000 1.60 1.76 0.27 0.29 35
NTIT-06 F14 60 36 58-62 45-50 1300 1.60 1.76 0.27 0.29 35

14
NTIR PERFORMANCE DATA

NTIR SERIES (380V / 3Ph)


Rated Starting Motor Rated
Flange Time (S) Torque Motor Power Factor Efficiency (%) Weight
Model Current (A) Current (A) Power (KW)
(ISO 5211) Poles (kg)
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

NTIR-05 50 0.50 0.51 0.16 0.16


NTIR NTIR-10 F05 100 0.53 0.54 0.16 0.16
20 17 1.6 1.5 0.83 0.72 57 67 14
- 200 NTIR-15 / F07 150 0.56 0.58 0.17 0.17
NTIR-20 200 4 0.62 0.63 0.17 0.17
NTIR-30 300 1.03 0.95 0.30 0.29
NTIR F07
NTIR-40 30 26 400 1.08 1.02 2.2 1.9 0.30 0.29 0.74 0.75 61 64 17
- 500 / F10
NTIR-50 500 1.12 1.12 0.31 0.29

NTIRM SERIES (380V / 3Ph)


Rated Starting Motor Rated
Flange Time (S) Torque Motor Power Factor Efficiency (%) Weight
Model Current (A) Current (A) Power (KW)
(ISO 5211) Poles (kg)
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

NTIRM-05 50 0.48 0.50 0.14


NTIRM NTIRM-10 F05 75 0.50 0.52 0.14
20 17 1.5 1.4 0.15 0.80 0.74 60 68 14
- 200 NTIRM-15 / F07 100 0.52 0.55 0.15
NTIRM-20 140 4 0.56 0.60 0.15
NTIRM-30 180 0.92 0.86 0.29
NTIRM F07
NTIRM-40 30 26 240 0.96 0.93 2.1 1.8 0.29 0.28 0.75 0.78 63 65 17
- 500 / F10
NTIRM-50 300 1.02 1.05 0.30

NTIR SERIES (220V / 1Ph)


Rated Starting Motor Rated Efficiency
Flange Time (S) Torque Motor Power Factor Weight
Model Current (A) Current (A) Power (KW) (%)
(ISO 5211) Poles (kg)
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

NTIR-05 40
NTIR NTIR-10 F05 60
- 200 20 17 0.86 0.90 1.20 1.10 0.10 0.12 0.96 0.94 52 70 14
NTIR-15 / F07 80
NTIR-20 100 4
NTIR-30 150
NTIR F07
NTIR-40 30 26 175 1.30 1.50 2.20 2.10 0.17 0.20 0.96 0.93 58 62 17
- 500 / F10
NTIR-50 220

NTIRM SERIES (220V / 1Ph)


Rated Starting Motor Rated
Flange Time (S) Torque Motor Power Factor Efficiency(%) Weight
Model Current (A) Current (A) Power (KW)
(ISO 5211) Poles (kg)
50Hz 60Hz Nm 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

NTIRM-05 30
NTIRM NTIRM-10 F05 40
- 200 20 17 0.76 0.82 1.10 1.00 0.11 0.12 0.97 0.95 68 71 14
NTIRM-15 / F07 55
NTIRM-20 70 4
www.newtork.co.kr

NTIRM-30 100
NTIRM F07
NTIRM-40 30 26 140 1.22 1.35 2.00 1.90 0.16 0.17 0.95 0.93 63 64 17
- 500 / F10
NTIRM-50 180

15
NTI DIMENSION

NTI SERIES EACH PART AND NAME

NTI SERIES DIMENSIONS


NEWTORK KOREA CO., LTD.

Parameter
Specification A B C D E F ØG ØH ØI J K ØL M

NTI-01 / 02 / 03 165 250 300 200 119 41 357 104 212 250 30 177 240

NTI-04 / 05 230 350 330 200 150 40 542 125 212 270 30 177 275

NTI-06 247 352 401 230 119 42 793 145 212 301 30 177 353

16
NTIT DIMENSION

NTIT SERIES EACH PART AND NAME

NTIT SERIES DIMENSIONS

Parameter
Specification A B C D E F G
www.newtork.co.kr

NTIT - 01 / 02 308 110 146 162 158 160 210

NTIT - 03 / 04 / 05 / 06 / 07 380 135 202 168 158 188 275

17
NTIR DIMENSION

NTIR SERIES EACH PART AND NAME

NTIR SERIES DIMENSIONS


NEWTORK KOREA CO., LTD.

Parameter
Specification A1 A2 A3 B ØD ØD1 E H1 H2 L L1 L2 L3 L4 L5 F

NTIR-200 35 26.5 30 90 140 170 16.5 67 323 122 45 68 143 60 44 42

NTIR-500 39 26.5 30 120 200 216 16.5 67 321 119 60 82 204 78 44 58

18
NTI / NTIT WIRING DIAGRAM

www.newtork.co.kr

19
20
NEWTORK KOREA CO., LTD.

NTIR WIRING DIAGRAM


TERMINAL COMPOSITION

www.newtork.co.kr

21
CERTIFICATION

Patent 1. Manual valve opening degree Patent 2. Electric Autuator having detecting Patent 3. Check valve opening and closing
detecting apparatus and method and removing function for foreign substance characteristics monitoring and diagnosing devices

ISO 9001:2015 and ISO 14001:2015 OHSAS 18001:2007 Certificate of Risk assessment

Certificate of award from Certificate of Venture Business Certificate of INNO-BIZ


Korea Water Resources Corporation
NEWTORK KOREA CO., LTD.

Certificate of Product-specific approved Certificate of Direct production Certificate of Promising Export Firm
exporter of ASEAN-ROK by the SMBA, KOREA

22
CUSTOMER SUPPORT

Newtork Korea endeavors to achieve the following :


▶︎ Manufacturing superior quality products
▶︎ Developing technology for user convenience
▶︎ Excellent actuation solution
▶︎ Fast and accurate on-site service

Our engineers provide safe and reliable service, and ideally perform highly
demanding tasks, such as retrofit and replacement of electric actuators.
As always, we promise to do our best to meet your needs and ensure
satisfaction.

Total consulting service


With 30 years of experience, we provide comprehensive customized service
with original knowledge of all aspects of electric valve actuators and world-class
engineering, and the technical resources to provide diagnostics tailored to
customer need by identifying operational problems and presenting solutions.

Maintenance and Inspection service


Our experienced managers and skilled engineers are dispatched to projects
according to site schedules to provide inspection and maintenance services
for all electric actuators installed in customer plants. Therefore, NEWTORK
KOREA's maintenance and inspection services ensure customers to save
time and cost and keep facilities running smoothly and profitably without
having to consult an engineer. This service also improves plant facilities and
equipment reliability.
www.newtork.co.kr

WORKSHOP FIELD RETROFIT REPLACE COMMI


CONSULTING
OVERHAUL SUPPORT SERVICE MENT SSIONING

23
NEWTORK KOREA CO., LTD. NEWTORK's products are made out to be operate safely in useful life. However, the products may cause
malfunction since it used from various industry, condition and environment, NEWTORK can provide a
#602 Hyeondae I Valley, 31, Galmachi-ro
general guide but no all warnings and cautions. Thus the buyer/user has the ultimate responsibility for the
244beon-gil, Jungwon-gu, Seongnam-si, select, install, operate and maintain of the appropriate products. Buyer/user has to aware of installation
Gyeonggi-do, Republic of Korea, 13212 instructions which is included in product to use product safe. The information contained in this document is provided for
Tel. +82-31-711-3107 informational purposes only. Also product's standard, measurement and information subject to change without notice
since NEWTORK is consistently improve products design. Please feel free to contact NEWTORK if you have any further
Fax. +82-31-711-3057
questions or concerns. All copyright in this document are the property of NEWTORK, and it is not allowed to reprint
E-mail. [email protected] without permission, copy and distribute for commercial purposes.

NTK-0001(J) Feb. 2018