Manual de Servicios y Fallos
Manual de Servicios y Fallos
UNIT:
AUD-18UX4SGKL AUC-18UX4SGAA
AUD-24UX4SZLH AUC-24UX4SZEA
AUD-36UX4SAMH AUC-36UX4SAEA
AUD-48UX6SPHH AUC-48UX6SPFA
AUD-60UX6SPHH AUC-60UX6SPFA
AUD-18UX4SZKL1 AUC-18UR4SZAA1
AUD-24UX4SALH1 AUC-24UR4SAEA1
AUD-36UX4SAMH1 AUC-36UR4SAEA1
AUV-18UR4SZA1
AUV-24UR4SAA1
AUV-36UR4SAB1
AUV-48UR6SPC
AUV-60UR6SPC
Hisense Corporation
1.GENERAL 1
2.SPECIFICATION 15
3-1 INDOOR 24
3-2 OUTDOOR 29
4. DIAGRAM&DATA 33
5.ELECTRICAL DATA 44
6.CONTROL MODE 80
7.TROUBLE SHOOTING 86
8.CHECKING COMPONENTS 97
1.1 Featuress
Features
18
8k: optional 10Pa
1 /30Pa, 24K/36K 50Pa/80Pa(For AUD-24UX44SALH1&AUD
D-36UX4SAMH
H1,freely
chhanged between1-80Pa), 48
8K/60K: 80P
Pa/120Pa sta
atic Pressure
e.
R410
0A can prote
ect the enviro d not harm to the ozone
onment and do e layer.
¾ 24-hour Timer
T ON an
nd OFF
¾ Mute Ope
eration
e.
noise
¾ Meeting Various
V Insta
allation Requ
uirements
The back-air-inle
et type is usu
ually to be ad
dopted accorrding to the a
actual installa
ation
spacce.
The unit is also installed with down-air-inlet type and the noise will increase about 5-6
dB.
When the power supply is recovered after break, all preset are still effective and the
When there is something wrong with the air-conditioner,the micro computer could
diagnose the faults, which can be read from the display and is convenient for
maintenance.
C
Cassette T
Type Air Condition
ner
Fe
eatures
The indoo
or unit can be
b installed in
nside the ceilling convenie
ently.
R410A ca
an protect the environme
ent and do no
ot harm to the ozone laye
er.
¾ 24-hour Timer
T ON an
nd OFF
This Time
er can be sett to automatiically turn the
e unit on or off
o within a 24
4-hour period.
¾ Mute Ope
eration
The exce
ellent fan dessign enable the airflow to be quiet and
d smooth witth minimum noise.
n
¾ Self Reco
overy of Pow
wer Break
When the
ere is someth
hing wrong with
w the air-co
onditioner, the micro com
mputer could diagnose
d
Features
The indoor unit’s thickness is only 230mm,can be installed inside the ceiling conveniently.
According to the actual installation space,The indoor unit can be installed in the ceiling
New Refrigerant-R410A
R410A can protect the environment and do not harm to the ozone layer.
This Timer can be set to automatically turn the unit on or off within a 24-hour period.
¾ Mute Operation
The excellent fan design enable the airflow to be quiet and smooth with minimum noise.
The refrigerant pipe can be connect from 3 different directions(rear,right or top) .More methods,
more conveniently.
When the power supply is recovered after break, all preset are still effective and the
When there is something wrong with the air-conditioner, the micro computer could diagnose the
faults, which can be read from the display and is convenient for maintenance.
Type Model 18 24 36 48 60
A U C -18 U R 4 S Z A A 1
serial number
K:Outdoor Unit Indetification
G:Indoor Unit Indetification
S:Refrigement R410A F:Refrigement R22
4:220V-240V/50HZ/1P 6:380V-415V/50HZ/3P
X: Wire Romote Controller R:Wireless Romote Controller
U:DC-Invert Heat Pump Type H:Heat Pump Type C:Cooling Only
Cool Capacity:18x10 3Btu/h
Type:D-Duct Type,C-Cassette Type,V-Ceiling&Floor Type,W-Outdoor Unit
Unit
Air Conditioner
Duct Type
M
Model AUD-18UX44SGKL AUD-24UX4S
SZLH
Indoor
Ouutdoor
AUD-48UX6S
SPHH
M
Model AUD-36UX44SAMH
AUD-48UX6S
SPHH
Indoor
Ouutdoor
AUD-18UX44SZKL1 AUD-24UX4S
SALH1
M
Model
Indoor
Ouutdoor
M
Model AUD-36UX44SAMH1
Indoor
Ouutdoor
Caassette Type
M
Model AUC-18UX44SGAA AUC-24UX4S
SZEA
Indoor
Ouutdoor
AUC-48UX6S
SPFA
M
Model AUC-36UX44SAEA AUC-60UX6S
SPFA
Indoor
Ouutdoor
10
AUC-24UR4S
SAEA1
M
Model AUC-18UR44SZAA1
AUC-36UR4S
SAEA1
Indoor
Ouutdoor
11
Indoor
Outdoo
r
AUV-48UR6SPC
Model AUV-36UR4SAB1
AUV-60UR6SPC
Indoor
Outdoo
r
12
DISPLAY PANEL:
Cassette Type
18k
24K,36K,48K,60K
13
Ceiling&Floor type
14
2. Specifications
Duct Type
Model AUD-18UX4SZKL1 AUD-24UX4SALH1 AUD-36UX4SAMH1 AUD-18UX4SGKL AUD-24UX4SZLH AUD-36UX4SAMH AUD-48UX6SPHH AUD-60UX6SPHH
Indoor model AUD-18UX4SKL1 AUD-24UX4SLH1 AUD-36UX4SMH1 AUD-18UX4SKL AUD-24UX4SLH AUD-36UX4SMH AUD-48UX4SHH AUD-60UX4SHH
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
Ph-V-H
Power supply 20V-240V ~/50Hz 380V-415V,3N~/50Hz
z
Dehumidification L/h 1.4 1.8 2.4 1.4 1.8 2.4 3.3 4.5
Winding resistance Ω 0.55(20℃) 0.73 (at20℃) 055(20℃) 0.95(20℃) 0.59 0.95(20℃) U-V: U-V:
15
Indoor model AUD-18UX4SKL1 AUD-24UX4SLH1 AUD-36UX4SMH1 AUD-18UX4SKL AUD-24UX4SLH AUD-36UX4SMH AUD-48UX4SHH AUD-60UX4SHH
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
25℃) 25℃)
MITSUBISHI MITSUBISHI
Brand GMCC GMCC GMCC GMCC HIGHLY GMCC
ELECTRIC ELECTRIC
Fan Indoor Speed 1130/850/950(10 1000/910/810(30 1060/980/900(30P 1130/850/950(10 1070/990/860(50 1150/1070/1020( 1250/1200/1100( 1250/1200/1100(
r.p.m
Hi/Med/Low Pa) Pa) a) Pa) Pa) 50Pa) 120Pa) 120Pa)
Indoor Hi/Med/Low m³/h 850 1100 1800 850 1100 1700 2000 2000
Air circulation
Outdoor Hi/Med/Low m³/h -- -- -- -- -- -- -- --
30*/(1~80 30*/(1~80
Static Pressure(*Default Setting) Pa 10*/30 10*/30 50*/80 50*/80 80*/120 80*/120
optional) optional))
Indoor L×W×H mm 1170×447×190 900×720×270 1300×720×270 1170×447×190 900×720×270 1300×720×270 1300×800×350 1300×800×350
Dimensions
Outdoor L×W×H mm 900×300×640 950×340×840 950×340×840 800×260×570 900×300×640 940×340×840 950×340×1386 950×340×1386
Indoor L×W×H mm 1340×580×236 1170X340X870 1570X340X870 1340×580×236 1170X340X870 1570X340X870 1550X940X410 1550X940X410
Packing
Outdoor L×W×H mm 1050×400×700 1110×460×980 1110×460×980 950×365×645 1050×700×400 1110×460×980 1110×460×1530 1110×460×1530
Weight Indoor Net/Gross kg 24/28 32/37 43/51 24/28 32/37 38/43 50/58 50/58
16
Indoor model AUD-18UX4SKL1 AUD-24UX4SLH1 AUD-36UX4SMH1 AUD-18UX4SKL AUD-24UX4SLH AUD-36UX4SMH AUD-48UX4SHH AUD-60UX4SHH
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
Outdoor Net/Gross kg 45/51 69/73 70/74 35.5/39 50/56 70/74 101/107 108/112
Connection Power wiring mm2 3 core x1.5 3 core x2.5 3 core x2.5 3 core x1.5 3 core x2.5 3 core x2.5 5 core x2.5 5 core x2.5
wiring Signal wiring mm2 4core x0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75
Throttle Type EEV EEV EEV EEV EEV EEV EEV EEV
Cooling -15~48
Ambient temp ℃
Heating -10~24
17
Cassette type
Model AUC-18UR4SZAA1 AUC-24UR4SAEA1 AUC-36UR4SAEA1 AUC-18UX4SGAA AUC-24UX4SZEA AUC-36UX4SAEA AUC-48UX6SPFA AUC-60UX6SPFA
Indoor model AUC-18UR4SAA1 AUC-24UR4SEA1 AUC-36UR4SEA1 AUC-18UX4SAA AUC-24UX4SEA AUC-36UX4SEA AUC-48UX4SFA AUC-60UX4SFA
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
32,400
Cooling 17,100(4,100-22 23,900
Btu/h (12,300-35,800 17000 21800 34100 41000 58000
,200) (7,500-27,300)
)
Capacity
kW 5.6(1.8-7.2) 8.2(2.5-10) 11.0(3.05~13.8) 5.6 7 11.5 15 20
37,500
Heating 19,100(6,100-24 28,000
Btu/h (10,400-47,100 19100 23900 39200 51200 68200
,600) (8,500-34,100)
)
Dehumidification L/h —— —— —— —— —— —— —— ——
1.49(0.40~
Cooling kW 2.3(0.40~3.6) 3.07(0.4~4.2) 1.552 1.91 3.07 3.72 5.095
Rated input 2.25)
Rated Cooling A 6.6 10.1 13.4 6.9 8.5 13.36 6.5 6.5
18
Indoor model AUC-18UR4SAA1 AUC-24UR4SEA1 AUC-36UR4SEA1 AUC-18UX4SAA AUC-24UX4SEA AUC-36UX4SEA AUC-48UX4SFA AUC-60UX4SFA
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
Type Rotary
U-V: U-V:
MITSUBISHI MITSUBISHI
Brand GMCC GMCC GMCC GMCC HIGHLY GMCC
ELECTRIC ELECTRIC
Mode SIC72FW-D8124-2
Indoor EHDS50AQ ARW5901QH EHDS50AQH YDK95-28-4-B ARW5901QH EHDS50AQH SIC72FW-D8124-2B
l B
Fan motor
Mode SIC-71FW-D812 SIC-71FW-D812 YDK65-6-9024 YDK65-6-9024
Outdoor ARW4401QH YDK29-6I-22 YDK70-6H-3 YDK95-6-9043
l 1-1 1-1 YDK65-6-9061 YDK65-6-9061
Air Indoor Hi/Med/Low m³/h 850 1100 1600 850 1100 1600 2000 2400
Indoor L×W×H mm 650×570×270 840×840×248 840×840×248 650×570×270 840×840×248 840×840×248 840×840×298 840×840×298
Dimensions
Outdoor L×W×H mm 900×300×640 950×340×840 950×340×840 800×260×570 900×300×640 940×340×840 950×340×1386 950×340×1386
19
Indoor model AUC-18UR4SAA1 AUC-24UR4SEA1 AUC-36UR4SEA1 AUC-18UX4SAA AUC-24UX4SEA AUC-36UX4SEA AUC-48UX4SFA AUC-60UX4SFA
Outdoor model AUW-18U4SZ1 AUW-24U4SA1 AUW-36U4SA1 AUW-18U4SG AUW-24U4SZ AUW-36W4SA AUW-48U6SP AUW-60U6SP
Panel L×W×H mm 650×650×30 950×950×37 950×950×37 650×650×30 950×950×37 950×950×37 950×950×37 950×950×37
Indoor L×W×H mm 770×750×310 930×930×290 930×930×290 770×750×310 930×930×290 930×930×290 930×930×340 930×930×340
Packing Outdoor L×W×H mm 1050×400×700 1110×460×980 1110×460×980 940×360×640 1050×700×400 1110×460×980 1110×460×1530 1110×460×1530
Panel L×W×H mm 730×730×130 1010×990×95 1010×990×115 730×730×130 1010×990×95 1010×990×95 1010×990×95 1010×990×95
Indoor Net/Gross kg 21/25.5 24/30 26/32 21/25.5 24/30 26/32 29/35 29/35
Weight Outdoor Net/Gross kg 45/51 69/73 70/74 35.5/39 50/56 70/74 101/107 108/112
Panel Net/Gross kg 2.4/5 6/7.5 6/7.5 2.4/5 6/7.5 6/7.5 6/7.5 6/7.5
Low/Hi/sound
Indoor Db --/48/58 36/42/53 --/50/61 --/48 36/42 --/50 43/49 43/49
power
Noise lever
Low/Hi/sound
Outdoor Db 45/50/62 --/58/70 --/58/70 --/56 53/58 --/58 --/60 --/60
power
Connection Power wiring mm2 3 core x1.5 3 core x2.5 3 core x2.5 3 core x1.5 3 core x2.5 3 core x2.5 5 core x2.5 5 core x2.5
wiring Signal wiring mm2 4 core shielded wire x 0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75 4core x0.75
Throttle Type EEV EEV EEV EEV EEV EEV EEV EEV
Cooling -15~48
Ambient temp ℃
Heating -10~24
20
Type Rotary
U-V:
U-V: 2433;U-W :2433; U-V: 2433;U-W :2433;
2.806;U-W :2.806;
Compressor Winding resistance Ω M:2.1,A:2.81 M:1.37,A:1.7
V-W: 2.651 (at
V-W: 2.304(at 25℃) V-W: 2.304(at 25℃)
25℃)
MITSUBISHI
Brand GMCC GMCC GMCC MITSUBISHI ELECTRIC
ELECTRIC
Fan motor Indoor Model YSK110-22-4-A( HS24) SIC-70CW-F1100-6 SIC-70CW-F1140-3 Y7S423C032 Y7S423C032
21
Winding
M:79.7;A:59.4,20.2,10
resistance M:187A:245,60,33,143 M:209.4;A:245,60,33,143 M:75;A:97.5 M:79.7;A:59.4,20.2,108
8
(at20℃)
YDK65-6-9024 YDK65-6-9024
Model ARW4401QH SIC-71FW-D8121-1 SIC-71FW-D8121-1
YDK65-6-9061 YDK65-6-9061
Outdoor Winding
M:83;A1:23.4A2:14A1:6 M:83;A1:23.4A2:14A1:
resistance M:231.5;A:168 M:78;A:36.2,51.5,109.2 M:59.1;A:85.8
3.5 63.5
(at20℃)
--/64(SOUND
Indoor Hi/Med/Low dB(A) --/54(SOUND POWER) --/63(SOUND POWER) 48/50/53 48/50/53
Noise lever POWER)
Outdoor Hi/Med/Low dB(A) --/62(SOUND POWER) --/65(SOUND POWER) --/70(SOUND --/60 --/60
22
POWER)
Cooling -15~48
Ambient temp ℃
Heating -10~24
23
3-1 INDOOR
Duct type
24
25
Cassette type
18K
24K,36K
26
48K,60K
27
Ceiling&Floor Type
28
3-2.OUTDOOR
18K(AUW-18U4SG)
29
18K(MODEL: AUW-18U4SZ1)
24K(MODEL: AUW-24U4SZ)
30
24&36K
(MODEL: AUW-24U4SA1, AUW-36U4SA1, AUW-36W4SA)
31
48K&60K
(MODEL: AUW-48U6SP、AUW-60U6SP)
32
4. Diagrams&DATA
33
Ambient
Ambient temperature
Discharge sensor
temperature
temperature
sensor
sensor
4-Way Valve
Discharge
Coil
Pressure
temperature Outdoor
Switch
sensor Coil heat
temperature exchanger
sensor
Suction
temperature
sensor
Indoor heat exchanger
Defrost
temperature
sensor
Accumulator
Compressor
Indoor Outdoor
34
48K&60K
Stop Valve
Ambient
Ambient temperature
Discharge sensor
temperature
temperature Suction
sensor
sensor Pressure
4-Way Valve Switch
Discharge
Coil
Pressure
temperature Outdoor
Switch
sensor Coil heat
temperature exchanger
sensor
Suction
temperature
Indoor heat exchanger sensor
Defrost
temperature
sensor
Accumulator
Compressor
Indoor Outdoor
35
*Do your best to reduce the pipe length. Long pipe may cause capacity of the indoor unit incline.
36
4-3ELECTRIC Diagrams
● Use an ELB (Electric Leakage Breaker). If not used, it will cause an electric shock or a
fire.
● Do not operate the system until all the check points have been cleared.
(A) Check to ensure that the insulution resistance is more than 1 megohm, by measuring
the resistance between ground and the terminal of the electrical parts. If not, do not
operate the system until the electrical leakage is found and repaired.
37
(B) Check to ensure that the stop valves of the outdoor unit are fully opened and then start
the system.
(A) Do not touch any of the parts by hand at the discharge gas side, since the compressor
chamber and the pipes at the discharge side are heated higher than 90℃.
(B) DO NOT PUSH THE BUTTON OF THE MAGNETIC SWITCH(ES). It will cause a
serious Accident.
NOTES:
1) Follow local codes and regulations when selecting field wires.
2) The wire sizes marked in the table are selected at the maxim current of the
unit according to the European Standard ,En60 335-1. Use the wires which are
not lighter than the ordinary tough rubber sheathed flexible cord (code
designation H07RN-F) or ordinary polychloroprene sheathed flexible
cord (code designation H07RN-F) .
3) Use a shielded cable for the transmitting circuit and connect it to ground .
4) In the case that power cables are connected in series, add each unit
maximum current and select wires below.
* in the case that current exceeds 63A, do not connect cables in series.
38
18K
18K Curve for 10Pa ESP
35
30 L M H
25
20
ESP
15
10
0
500 600 700 800 900 1000
Air flow(m3/h)
50
45
40
35
ESP
30
25
20
15
10
500 600 700 800 900 1000 1100
Air flow(m3/h)
39
24K
24K Curve for 50Pa ESP
90
80 L M H
70
60
ESP
50
40
30
20
10
700 800 900 1000 1100 1200 1300 1400
Air flow(m3/h)
130
120 L M H
110
100
90
ESP
80
70
60
50
40
600 700 800 900 1000 1100 1200 1300 1400 1500
Air flow(m3/h)
40
90
80
70 L M H
ESP
60
50
40
30
900 1100 1300 1500 1700 1900
Air flow(m3/h)
130
120 L M H
110
100
ESP
90
80
70
60
50
800 1000 1200 1400 1600 1800 2000
Air flow(m3/h)
41
48K
48K Curve for 80Pa ESP
120
110 L M H
100
90
ESP
80
70
60
50
1500 1700 1900 2100 2300 2500
Air flow(m³/h)
150 L M H
140
130
ESP
120
110
100
90
1500 1700 1900 2100 2300 2500
Air flow(m³/h)
42
60K
60K Curve for 80Pa ESP
120
110 L M H
100
90
ESP
80
70
60
50
1500 1700 1900 2100 2300 2500
Air flow(m³/h)
150 L M H
140
130
ESP
120
110
100
90
1500 1700 1900 2100 2300 2500
Air flow(m³/h)
43
44
45
46
47
24K ,36K,48K,60K
48
24K,36K
49
50
51
24K
AUW-24U4SZ
52
AUW-24U4SA1
53
36K
AUW-36U4SA
54
AUW-36U4SA1
55
AUW-48U6SP
AUW-60U6SP
56
Duct type
18K,48K,60K
&AUD-24UX4SLH, AUD-36UX4SMH
AUD-24UX4SLH1, AUD-36UX4SMH1
57
CASETTE Type
18K
24K,36K,48K,60K
58
24k,36k
59
CONTROL BOARD(AUW-24U4SZ)
60
AC N IN
4-way valve
AC L IN
Heater L
Communication SI
IPM-SI Communication N
IPM power
DC+
Outdoor/suction/coil Sensor
Overload protection switch
Discharge Sensor
CONTROL BOARD(AUW-36U4SA)
61
4-way valve
Heater N
Heater L AC N IN
AC fan motor
Earth
AC L IN
Communication N
AC L OUT
DC+
DC-
Suction Sensor
coil/defrost Sensor
CONTROL BOARD(AUW-48U6SP、AUW-60U6SP)
Heater N
Transformer Down fan motor Up fan motor
62
(AUW-18U4SZ1,AUW-24U4SA1、AUW-36U4SA1)
63
Heater N
Heater L AC N IN
Earth
AC L IN
Communication N
AC L OUT
DC+
DC-
Suction Sensor
coil/defrost Sensor
IPM Board
IPM Board(AUW-18U4SG)
64
To Electrolytic
Capacitor +
To PFC Inductor-2
AC L IN
To PFC Inductor-1
To Electrolytic
Capacitor -
AC N IN
IPM Power
To Compressor W
To Compressor V
To Compressor U
To Main Control
To Electrolytic Board
Capacitor +
(AUW-24U4SZ / AUW-36U4SA)
To PFC To PFC
Inductor-2 Inductor-1
To Electrolytic
Capacitor + ac L in
ac N in
To Electrolytic
Capacitor -
IPM Power
To Compressor W
To Compressor V
To Compressor U
To Electrolytic
Capacitor +
To Main Control
Board
(AUW-18U4SZ1、AUW-24U4SA1、AUW-36U4SA1)
65
(AUW-48U6SP、AUW-60U6SP)
AC IN-W Compressor
AC IN-V
Contacto Compressor
AC IN-U
Inductor
Compressor
AC IN
Inductor L1
Contact
IPM-SI
66
48K&60K
67
1)SWITH button:Indoor parameters and outdoor parameters can be select in turn by press it.
2)INCREASE button:Each time it is pressed,the number rises by 1,hold down it,the number will be
rapidly rises;
3)DECREASE button:Each time it is pressed,the number lowers by 1,hold down it,the number will be
68
rapidly lowers.
69
70
71
72
73
74
75
76
77
78
79
80
18k&24k&36K:
a.c 220V~240V, 50Hz, with its fluctuation in the range of (198V – 253 V).
48K&60K:
conditioner has not received a signal from the remote controller when the set time is up, it
will automatically start and operate in the preset conditions.
2. Timer off: When set to stop in a set time by the remote controller, the air conditioner
will start in the timer off condition. When the set time is up, the air conditioner will turn off
after receiving a signal from the remote controller. If the air conditioner has not received a
signal from the remote controller when the set time is up, it will turn off automatically.
3. Neither the turning on nor turning off operation will cancel the timer function。
3.4 Sleep
1. In the heating, cooling or dehumidifying mode, press the “Sleep” button on the remote
controller to start or cancel the sleep function in turn, and at the same time the sleep icon on
the display screen will be on or off accordingly.
2. In the heating mode, the set temperature will decrease automatically after the sleep
function is started.
3. In the cooling mode, the set temperature will rise automatically after the sleep function
is started.
4. In default, the setting is to cancel the sleep function. Turning off the unit will also
cancel the sleep function.
3.5 High efficient run function
In Cool, Dehumidification, Fan mode, press the "SUPER " to enter the refrigeration mode,
set the temperature automatically adjust to 18℃; the Fan speed is powerful speed;
In the heating mode, powerful function is invalid for H1 wireless remote controller.
In the indoor machine operation mode,You may turn on mute function and turn off mute
function by mute key, The air conditioner will run by mute fan speed in mute mode
3.7 prevent cooling wind mode
81
In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan will stop
or run slowly until the coil is warmth.
3.8 blow waste heating and waste cooling function
The heating mode, remote shutdown, such as indoor heat exchanger temperature is
higher, the wind blowing out opportunities continue to run the waste heat.
Cool and dehumidification mode , after the compressor close, indoor machine will
continue to set the speed of operation for a period of time.
Remote control setting dehumidifying mode, indoor machine forced to run at low
speed(high power key or a strong bond also maintain a low wind speed), the outdoor
If the product operation failure, outdoor and indoor display control panel lights will quote
fault.
82
Summarization
1.1
18k、24k、36K
4. Working temperature:-20℃~85℃
1.2
48 k、60k
4. Working temperature:-20℃~85℃
2.Control function
83
To prevent indoor air conditioner evaporator temperature is too low, the indoor coil
sensor for real time detection of evaporator. If the indoor coil temperature is too low, the
compressor will protect.
Air can heat exchanger temperature sensor for monitoring, when the sensor when
the temperature is too high, the compressor will be automatic protection
When the compressor runs for a long time low frequencies, control system will start
the return oil program. The system in the oil return to the compressor.
2.5Operation Mode
Air conditioning mode is the operation mode set by users through remote controller,
four modes are available: cooling, heating, dehumidification, as well as fan mode.
Four-way valve of the outdoor machine shuts down when cooling and defrosting
but starts when heating. During the heating process, the four way valve to stop working for a
period of time after compressor disconnect.
84
When the pressure increases to a preset value, the pressure switch will
automatically protect. Compressor will stop and report the fault code protection.
85
“ER”shows indoor display panel Communication fault with indoor unit control board
86
87
88
T1 T2 T3
89
T1 T2 T3
VRF:
Indoor unit can indicate both indoor failure and outdoor failure ,but outdoor only
indicate outdoor’s.
90
T1 T2 T3
91
Fault
Fault description Fault description REMARKS
code
Outdoor environment
Outdoor environment temperature
1 temperature sensor short
sensor fault
circuit or open circuit
6 AC motor fault
Application of three-phase
8 Phase current imbalance
power supply models
Application of three-phase
9 Current U phase
power supply models
Application of three-phase
10 Current V phase
power supply models
Application of
Three phase power supply wiring
11 Sequence error three-phase power
line sequence error
supply models
Application of
12 Phase detection phase three-phase power
supply models
92
protection pressure
MUTI-SPLIT TYPE
AC voltage of high and low voltage protection Power input AC voltage is too low or ONLY
18
/ fault too high
FOR
MUTI-SPLIT&Inverter
Expansion valve A tube sensor
23 Expansion valve A tube sensor fault unitary types
short circuit or open circuit
FOR MUTI-SPLIT
&inverter unitary
Expansion valve A thick pipe sensor
27 Expansion valve A thick pipe sensor fault types
short circuit or open circuit
93
Application of
three-phase power
41 Current sensor fault
supply ON/OFF
TYPES
45 IPM fault
FOR VRF&inverter
94
35 (two upper and lower panel position detection switch is not in Only for MUTI-SPLIT
accordance with thereservation timing action)
51 Drainage Fault
52 Grid protection
56 Freeze Protection
57 Overload Protection
96
97
Cooling mode
NO
Test system
pressure.Does the low The pressure on the
pressure normal at high side.
service part ?
Recharge refrigerant
after air purging with
The pressure on the If the pressure is
the vacuum
low side. NO close to static
pump.Does the low
pressure?
pressure nomal over
again?
The system wants yes
refrigerant.The service yes
people must be ration
4-way valve collude or
refrigerant(about 100g/
compressor exhaust very
per)in the cooling
Air remaining at the ebb.
mode fixed
refrigerant system.
frequency.Is the low
pressure rise ? yes
NO
Recharge refrigerant .
The refrigerant system
blocked.Please check
the Capillary Tube( or NO
electronic expansion
valve)Is it blocked?
yes
Heating mode
Test system
pressure.Does the The pressure on the
high pressure normal high side.
at service part ?
NO
Recharge refrigerant
after air purging with Remove the back
The pressure on the panel."see"the
the vacuum
low side. capillary tube1 and
pump.Does the high
pressure normal over capillary tube2.Is it
again? defrosting?
Recharge refrigerant
yes
98
M1:146±15%Ω
M2: 33±15%Ω
M3: 43±15%Ω
A1: 63±15%Ω
A2: 23±15%Ω
A3: 119±15%Ω
99
AUD-24UX4SLH1
DC MOTOR
AUD-36UX4SMH1
DC MOTOR
100
AUD-36UX4SMH
Y7S423C024
101
102
25℃
24K,36K,48K,60K
DC-MOTOR
103
48K,60K
Y7S423C032
104
105
BROWN Winding
"M"-The Main Winding
"A"-The Auxiliary Winding
C Capacitor
M TP
A1 A2 A3 Hot Protector 130℃
WHITE
PINK
PURPLE YELLOW
AUW-24U4SZ
YDK70-6H-3:
WINDING
BLUE RED
Winding resistance ( at 20℃)
M: 78Ω A: 80Ω
Winding resistance ( at 20℃)
M: 283.5Ω A: 180Ω
AUW-36U4SA
YDK95-6-9043
106
BROWN YELLOW
WINDING
A
M: Main winding
M1 M2 M3 A: Auxiliary winding
Capacitor
P
P Hot protector
48K,60K
YDK65-6-9024、YDK65-6-9061
Test in resistance.
TOOL: Multimeter.
Test the resistance of the main winding. The outdoor fan motor is fault if the resistance of
main winding 0(short circuit)or∞(open circuit).
Notes:
1) Please don’t hold motor by lead wires.
2) Please don’t plug IN/OUT the motor connecter while power ON.
3) Please don’t drop hurl or dump motor against hard material. Malfunction may not be observed at
early stage after such shock. But it may be found later, this type of mishandling void our
warranty.
107
AUW-18U4SZ1
DA131S1B-28FZ
AUW-24U4SZ
108
AUW-36U4SA / AUW-36U4SA1
DA250S2C-30MT
AUW-48U6SP(TNB306FPNMC)
109
Test in resistance.
TOOL: Multimeter.
Test the resistance of the winding. The compressor is fault if the resistance of winding
0(short circuit)or∞(open circuit)
Familiar error:
1)Compressor motor lock.
2)Discharge pressure value approaches static pressure value .
3)Compressor motor winding abnormality.
Notes:
1)Don’t put a compressor on its side or turn over.
2) Please assembly the compressor in your air conditioner rapidly after removing the plugs.
Don’t place the comp. In air for along time.
3)Avoiding compressor running in reverse caused by connecting electrical wire incorrectly.
4)Warning! In case AC voltage is impressed to compressor, the compressor performance will
below because of its rotor magnetic force decreasing.
110
5. STEP MOTOR
5
4 2
Test in resistance.
TOOL: Multimeter.
Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short
circuit)or∞(open circuit).
6. FUSE
Checking continuity of fuse on PCB ASS’Y.
1) Remove the PCB ASS’Y from the electrical component box. Then pull out the fuse from the
PCB ASS’Y (Fig.1)
Fuse
PCB Ass'Y
Fig.1
2) Check for continuity by a multimeter as shown in Fig.2.
Fuse
Fig.2
7.CAPACITOR
1) Remove the lead wires from the capacitor terminals, and then place a probe on the
capacitor terminals as shown in Fig.3.
2) Observe the deflection of the pointer, setting the resistance measuring range of the
multimeter to the maximum value.
111
Multimeter
Compressor motor
capacitor
Fan motor
capacitor Fig.3
112