FXC FXC SERIES BENDING BEAM LOAD CELLS

Bending beam load cells for approved weighing,


automa c systems, dosage.

CAPACITIES (kg): 10, 20, 50, 100, 200, 300, 500.

OIML R60. C3 precision class.

Stainless steel. IP68 protec on.

Working in coopera on with:


VETEK AB The best solu on
HANTVERKSVÄGEN 15 - 76493 - VÄDDÖ - SWEDEN for advanced industrial
Tel. +46176-208920, [email protected], www.vetek.com
applica ons
Datasheet_FXC-C3_V2
MAIN FEATURES

C3 PRECISION CLASS
STAINLESS STEEL
IP68 PROTECTION
MAX. CAPACITIES FROM 10 TO 500 kg
SHIELDED CONNECTION CABLE
OIML CERTIFICATE AVAILABLE UPON REQUEST
TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

Minimum load cell verification interval: Vmin = EMax / 10.000


Maximum number of verification intervals: nLC= 3000
Full Scale Output: 2mV/V +/- 0,1%
Combined error: 0,017% of Full Scale Output (F.S.)
Non-Repeatability: 0,015% F.S.
Temperature effect on zero: +/- 0,002% /°C
Temperature effect on full scale output: +/- 0,0012% /°C
Compensated Temperature Range: –10°C/+40°C
Operating Temperature Range: –20°C/+60°C
Creep error after 30 minutes +/- 0,016% F.S.
Maximum tolerated excitation voltage: 15 VDC
Input Resistance: 385 ± 20 Ohm
Output Resistance: 350 ± 5 Ohm
Insulation Resistance: > 5000 MOhm
Safe Overload: 200% F.S.
Ultimate Overload: 300% F.S.
Nominal displacement: < 0,4 mm
4-wire shielded cable, 3m long, 4mm diameter.

ATEX VERSION

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each
load cell.
DETAIL 1

Dimensions (mm)

Wiring Code

Colour Function

-- SHIELD

BLACK OUTPUT +

RED INPUT +

BLUE OUTPUT -

WHITE INPUT -

VERSIONS

Available versions
Max
Codice (kg)

FXC10 10

FXC20 20

FXC50 50

FXC100 100

FXC200 200

FXC300 300

FXC500 500
VETEK AB
HANTVERKSVÄGEN 15 - 76493 - VÄDDÖ - SWEDEN

Tel.+46176-208920, [email protected], www.vetek.com

SALES AND TECHNICAL ASSISTANCE SERVICE