The TD-MIXVENT Series consists of low profile in-line mixed flow duct fans made from reinforced plastic or metal, designed for easy installation and maintenance. These fans come in various models with different motor specifications, including single and three-phase options, and feature adjustable timers in some versions. They are suitable for residential and commercial ventilation applications, particularly in limited space environments like false ceilings.

Uploaded by

Abubakkar Siddiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views5 pages

En TD Mixvent

The TD-MIXVENT Series consists of low profile in-line mixed flow duct fans made from reinforced plastic or metal, designed for easy installation and maintenance. These fans come in various models with different motor specifications, including single and three-phase options, and feature adjustable timers in some versions. They are suitable for residential and commercial ventilation applications, particularly in limited space environments like false ceilings.

Uploaded by

Abubakkar Siddiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

IN-LINE MIXED FLOW DUCT FANS

TD-MIXVENT Series

Range of low profile in-line mixed


flow duct fans manufactured in tough
reinforced plastic (from 160 to 800
models) or with metal casing steel
finished in a tough epoxy-polyester paint
coating (from 1000 to 6000 models).
The unique design of the support
bracket allows the motor and impeller
assembly to be fitted or removed without
dismantling the adjacent ducting.

Motors
Models 160-2000:
Class B, with ball bearings and safety
thermal overload protection. IP44.
Direct 2 or 3 speed connection and also
suitable for voltage speed control.
Electrical supply:
Single phase 230V-50Hz.
(models from 160 to 350)
Single phase 230V-50/60Hz.
(models from 500 to 2000)

Models 4000 and 6000: Class F, with ball


bearings and safety thermal overload
protection. IP54.
Suitable for voltage speed control.
Electrical supply:
Single phase 230V-50/60Hz.
Three phase 400V-50/60Hz
(model 4000) or
400V-50Hz (model 6000)

Additional information
Three phase models adjustable by
inverter control.

TD-MIXVENT-T models
TD-MIXVENT versions fitted with a
run-on-timer adjustable within 1 and 30
minutes and one speed or 3-speed motor
(depending on the model) not suitable for
speed control.

The MIXVENT-TD fans offer the ideal in-line duct fan solution for a wide range of
general residential or commercial ventilation application into.

780 In-Line duct fans TD-MIXVENT www.solerpalau.com


IN-LINE MIXED FLOW DUCT FANS
TD-MIXVENT Series

LOW PROFILE

Classic In-line Ventilation Mixed flow


centrifugal centrifugal casing MIXVENT

The low profile of the MIXVENT-TD fans makes them the most effective solution for
installations where the space of installation is limited such as false ceilings.

EASY TO MOUNT EASY MAINTENANCE

Fix the support bracket. Place the impeller and


motor assembly.

The unique design of the support bracket allows the motor and
impeller assembly to be fitted or removed without dismantling the
adjacent ducting.

Carry out the wiring Connect the ducts.


connections.

FLEXIBLE MOUNTING POSITION MODELS TD-MIXVENT-T MODEL 160

Can be mounted at any place of the air duct. Models MIXVENT-TD-T (from Model TD-160/100N SILENT
160 to 800 models) are fitted with offer very low noise level,
an adjustable timer between 1 with a motor mounted on
and 30 minutes and are supplied silent-elastic-blocks which
with a one-speed or 3-speed absorb the vibrations.
motor (depending on the model)
not suitable for speed control.

www.solerpalau.com In-Line duct fans TD-MIXVENT 781


IN-LINE MIXED FLOW DUCT FANS
TD-MIXVENT Series

DESIGN CHARACTERISTICS
160 250 350 500 800 800N 1000 1300 2000 4000 6000

POLYPROPYLENE CASING • • • • • •
STEEL CASING • • • • •
ABS IMPELLER • • • • • •
ALUMINIUM IMPELLER • • • • •(1)
PROTECTION CLASS II II II II II II I I I I I

THERMAL PROTECTION BY FUSE • • •


MANUAL RESETTING THERMAL PROTECTOR (PTC) • • • • • • • •
BALL BEARINGS GREASED FOR LIFE • • • • • • • • • • •
1 SPEED CONTROLLABLE MOTOR • •
2 SPEED CONTROLLABLE (2) MOTOR • • •
3 SPEED CONTROLLABLE (2) MOTOR • • • • • •
(1) Model from one piece die cast aluminium impeller.
(2) Models with Run-On-Timer fitted (TD-MIXVENT-T) are not controllable.

TECHNICAL CHARACTERISTICS SPEED


TD-MIXVENT Speed Maximum Maximum Maximum Sound Min-Max Weight Duct 3-speed Speed Wiring
(r.p.m.) absorbed absorbed airflow pressure air (kg) diameter switch controller diagram
power current (m3/h) level* Temperature (mm) (nº) **
(W) (A) (dB(A)) (°C)

2400 29 0,17 180 24 COM-2 RMB-1,5


TD-160/100 N SILENT -20/+40 1,4 100 9, 10
2200 18 0,11 150 22 REGUL-2 REB-1
2140 28 0,12 250 34 COM-2 RMB-1,5
TD-250/100 -20/+40 2 100 9, 10
1700 22 0,1 200 28 REGUL-2 REB-1
2050 26 0,11 330 33 COM-2 RMB-1,5
TD-350/125 -20/+40 2 125 9, 10
1590 20 0,09 250 28 REGUL-2 REB-1
2590 53 0,21 560 35
COM-3 RMB-1,5
TD-500/150 3V 2150 44 0,19 470 31 -20/+60 2,7 150 53, 54
INTER 4P REB-1
1820 41 0,18 390 26
2590 53 0,21 560 35
COM-3 RMB-1,5
TD-500/160 3V 2150 44 0,19 470 31 -20/+60 2,7 160 53, 54
INTER 4P REB-1
1820 41 0,18 390 26
2190 103 0,5 890 38
COM-3 RMB-1,5
TD-800/200N 3V 1870 93 0,47 750 34 -20/+60 4,9 200 53, 54
INTER 4P REB-1
1660 88 0,45 660 31
2480 132 0,55 1.040 40
COM-3 RMB-1,5
TD-800/200 3V 2290 133 0,56 940 37 -20/+60 4,9 200 53, 54
INTER 4P REB-1
2080 131 0,55 850 34
2790 130 0,46 960 38
COM-3 RMB-1,5
TD-1000/250 3V 2620 99 0,31 910 37 -40/+60 9,4 250 55, 56
INTER 4P REB-1
2510 91 0,28 850 37
2510 196 0,79 1.350 43
COM-3 RMB-1,5
TD-1300/250 3V 2200 153 0,54 1.160 40 -40/+60 9,4 250 55, 56
INTER 4P REB-1
1980 133 0,54 1.050 36
2630 290 1,03 1.830 48
COM-3 RMB-1,5
TD-2000/315 3V 2420 223 0,79 1.630 47 -40/+60 14 250 55, 56
INTER 4P REB-2,5
2130 173 0,64 1.430 41
RMB-3,5
TD-4000/355 1360 407 1,69 3.750 41 -40/+40 19 355 - 15, 16
REB-2,5
RMB-3,5
TD-6000/400 1400 680 2,92 5.310 44 -40/+40 26 400 - 17, 18
REB-5

RMT-3,5
TD-4000/355 TRIF 1150 309 0,66 3160 41 -40/+70 19 355 - 21
VFTM TRI 0,37
RMT-2,5
TD-6000/400 TRIF 1400 691 1,49 5.330 44 -40/+60 26 400 - 21
VFTM TRI 0,75
* Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

782 In-Line duct fans TD-MIXVENT www.solerpalau.com


IN-LINE MIXED FLOW DUCT FANS
TD-MIXVENT Series

TD-MIXVENT Speed Maximum Maximum Maximum Sound Min-Max Weight Duct


(models TD-MIXVENT (r.p.m.) absorbed absorbed airflow pressure air Temperature (kg) diameter
withrun-on timer) power current (m3/h) level* (°C) (mm)
(W) (A) (dB(A))

TD-160/100 NT SILENT 2400 29 0,17 180 24 -20/+40 1,4 100

TD-250/100 T 2140 28 0,12 250 34 -20/+40 2 100

TD-350/125 T 2050 26 0,11 330 33 -20/+40 2 125

2590 53 0,21 560 35


TD-500/150 T 3V** 2150 44 0,19 470 31 -20/+60 2,7 150
1820 41 0,18 390 26
2590 53 0,21 560 35
TD-500/160 T 3V** 2150 44 0,19 470 31 -20/+60 2,7 150
1820 41 0,18 390 26
2480 132 0,55 1.040 40
TD-800/200 T 3V** 2290 133 0,56 940 37 -20/+60 4,9 200
2080 131 0,55 850 34
* Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.
** See section of Wiring Diagrams.

DIMENSIONS (mm)
TD-160/100 N SILENT TD -250 to TD-2000 TD -4000 / TD-6000

C
B
ØK

D
ØE
ØF
A

J
G G
H
I

Model X A ØB C ØD E F G H
TD-250/100 188 303 176 115 97 100 90 80 60
TD-350/125 188 258 176 115 123 100 90 80 60
TD-500/150 212 295 200 127 147 112 130 80 60
TD-500/160 212 295 200 127 157 112 130 80 60
TD-800/200N 232,5 302 217 141 198 124 140 100 94
TD-800/200 232,5 302 217 141 198 124 140 100 94
TD-1000/250 291 386 272 192 248 155 168 145 140
TD-1300/250 291 386 272 192 248 155 168 145 140
TD-2000/315 356 450 336 224 312 188 210 182 178

Model A B C D ØE ØF G H I J ØK
TD-4000/355 377 238 451 224 426 354 150 368 474 340 8.5
TD-6000/400 407 249 249 267 487 399 160 425 547 370 8.5

www.solerpalau.com In-Line duct fans TD-MIXVENT 783


IN-LINE MIXED FLOW DUCT FANS
TD-MIXVENT Series

PERFORMANCE CURVES
– qv: Airflow in m3/h. HS : High speed
– psf: Static pressure in Pa. MS: Medium speed
– Dry air at 20ºC and 760 mmHg. LS: Low speed
– Performance data in accordance with ISO 5801 and AMCA 210-99 Standards.
– SFP: Specific fan power in W/m3/s (blue curves).

TD-350/125
TD-350/125 2 TD-500/150 3V 3V
TD-500/150
TD-500/160 3V
psf psf psf psf
[mmcda] [Pa] [mmcda] [Pa]
140
14 250
25
120
12
200
100 20
10
0 3
0
70 60
8 80 15 150 0
50
3
6
6 60 45
0

10 100 2
6 9
4 40 2
40
0

5
5 5 50
2 20 8

4 1 7 4 1
0 0 0 0
0 50 100 150 200 250 300 qv [m /h]
3
0 100 200 300 400 500 qv [m3/h]
P[W] P[W]
25 50

20 40

15 30

10 20
0 50 100 150 200 250 300 qv [m3/h] 0 100 200 300 400 500 qv [m3/h]

Sound power level spectrums in dB(A) Sound power level spectrums in dB(A)
Working point 63 125 250 500 1.000 2.000 4.000 8.000 LwA Working point 63 125 250 500 1.000 2.000 4.000 8.000 LwA
Inlet 28 34 51 55 56 51 42 32 60 Inlet 28 38 52 58 60 58 51 41 64
1 Outlet 25 31 50 54 55 52 43 33 59 1 Outlet 34 37 51 57 61 59 52 42 64
Break-Out 19 24 49 45 49 47 34 23 54 Break-Out 19 31 46 45 50 51 39 27 55
Inlet 24 33 50 53 55 52 43 34 59 Inlet 25 36 50 55 59 58 51 42 63
2 Outlet 26 31 51 54 55 52 43 34 59 2 Outlet 33 36 51 57 61 59 51 43 64
Break-Out 16 24 48 43 48 46 34 23 53 Break-Out 17 30 45 43 49 49 37 26 54
Inlet 26 34 48 54 56 53 45 36 60 Inlet 26 37 50 56 59 59 52 43 64
3 Outlet 27 33 49 56 54 52 43 34 60 3 Outlet 29 35 50 58 59 57 50 41 64
Break-Out 18 26 46 45 49 48 36 25 54 Break-Out 18 31 44 44 49 50 38 27 54
Inlet 22 29 46 49 50 46 36 27 54 Inlet 24 34 48 54 56 54 47 37 60
4 Outlet 19 26 45 49 50 47 37 28 54 4 Outlet 30 33 47 53 57 55 48 38 60
Break-Out 13 19 43 39 44 42 29 17 48 Break-Out 15 27 42 41 46 47 35 23 51
Inlet 19 27 45 47 50 46 38 29 54 Inlet 20 32 46 51 54 54 47 38 59
5 Outlet 20 26 46 49 50 47 38 29 54 5 Outlet 29 32 47 53 56 55 47 38 60
Break-Out 11 19 43 38 43 41 28 18 48 Break-Out 13 26 41 39 45 45 33 22 49
Inlet 21 29 43 50 51 49 41 32 55 Inlet 22 33 46 53 55 55 49 40 60
6 Outlet 22 29 45 51 50 48 39 29 55 6 Outlet 25 31 46 54 56 54 47 38 60
Break-Out 13 21 42 40 45 44 31 21 49 Break-Out 15 27 41 40 45 46 35 24 50
Inlet 19 30 44 50 51 50 42 33 56
7 Outlet 25 29 42 48 52 50 43 34 56
Break-Out 11 23 38 37 42 42 30 19 46
Inlet 16 28 42 46 50 50 42 33 54
8 Outlet 24 28 43 48 52 50 43 34 56
Break-Out 9 22 37 34 40 41 29 18 45
Inlet 18 29 42 49 51 51 44 36 56
9 Outlet 21 27 42 50 52 50 42 34 56
Break-Out 11 23 37 36 41 42 31 20 46

www.solerpalau.com In-Line duct fans TD-MIXVENT 785