ADAM-4510/4510S General/Isolated RS-422/485 Repeater
Isolated/ General RS-232 to 422/485
/4520/4522 Converter
Features
• Automatic internal RS-485 bus supervision
• No external flow control signals required for RS-485
• 3000 VDC isolation protection (ADAM-4510S/4520)
• Transient suppression on RS-485 data lines
• Speeds up to 115.2 Kbps
• Networking up to 4000 feet
Industrial Communication
• Reserved space for termination resistors
• Power and data flow indicator for troubleshooting
• Power requirement: +10 to +30 VDC
• Mounts easily on a DIN-rail or panel
Introduction
Most industrial computer systems come with standard • Accessories (supplied): ABS DIN-rail mounting adapter,
SECC panel mounting bracket
6
RS-232 serial ports. Though widely accepted, RS-232 has limited
transmission speed, range, and networking capabilities. The RS-422
• Plug-in screw terminal wiring: Accepts AWG 1- #12 or
and RS-485 standards overcome these limitations by using
2- #14 ~ #22 (0.5 to 2.5 mm2) wires
differential voltage lines for data and control signals. The
ADAM-4520/4522 converter lets you take advantage of RS-422 and • Operating temperature: -10 to 70° C (14 to 158° F)
RS-485 on systems originally equipped with RS-232. It transparently • Dimensions: 60 mm x 120 mm (2.36" x 4.41")
converts RS-232 signals into isolated RS-422 or RS-485 signals.
You do not need to change your PC's hardware or your software. ADAM-4510/4510S
The ADAM-4520/4522 lets you easily build an industrial grade, long
distance communication system with standard PC hardware. • Transmission speed (bps): 1200, 2400, 4800, 9600,
19.2 K, 38.4 K, 57.6 K, 115.2 K (switchable)
The ADAM-4510/4510S repeater simply amplifies, or boosts, existing
• Isolation voltage: 3000 VDC (ADAM-4510S only)
RS-422/485 signals to enable them to cover longer distances. It
extends the communication distance by 4000 ft. (1200 m) or • RS-422/RS-485 interface connector: Plug-in screw terminal
increases the maximum number of connected nodes by 32. • Power consumption: 1.4 W
An RS-485 network with Automatic Data Flow Control using ADAM-4520/4522
RS-232 Software • Transmission speed (bps): 1200, 2400, 4800, 9600,
The RS-485 standard supports half-duplex communication. This 19.2 K, 38.4 K, 57.6 K 115.2 K, RTS control and RS-422 mode
means that a single pair of wires is used to both transmit and receive (switchable)
data. Handshaking signals such as RTS (Request To Send) are
• Isolation voltage: 3000 VDC (ADAM-4520 only)
normally used to control the direction of the data flow. A special I/O
circuit in the ADAM-4510/4510S and ADAM-4520/4522 automatically • RS-232 interface connector: Female DB-9
senses the direction of the data flow and switches the transmission • RS-422/RS-485 interface connector: Plug-in screw terminal
direction. No handshaking signals are necessary—you can build an
RS-485 network with just two wires. This RS-485 control is • Power consumption: 1.2 W
completely transparent to the user. Software written for half-duplex
RS-232 works without modification. Ordering Information
❑ ADAM-4510: RS-422/RS-485 repeater
Specifications ❑ ADAM-4510S: Isolated RS-422/RS-485 repeater
• Power requirement: Unregulated +10 ~ +30 V DC . Module ❑ ADAM-4520: Isolated RS-232 to RS-422/485 converter
protected from power reversals
❑ ADAM-4522: RS-232 to RS-422/485 converter
• Case: ABS with captive mounting hardware
Daughterboards and Modules www.advantech.com 6-19