0% found this document useful (0 votes)
98 views1 page

MV Noah Gracia - Fire Control Plan

The document outlines the fire control plan for a vessel, detailing the equipment and systems in place for fire safety, including fire extinguishers, hoses, hydrants, and pumps. It specifies quantities and locations of fire safety equipment across various decks and compartments. Additionally, it includes information on portable fire extinguishers and other fire-fighting tools available on board.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views1 page

MV Noah Gracia - Fire Control Plan

The document outlines the fire control plan for a vessel, detailing the equipment and systems in place for fire safety, including fire extinguishers, hoses, hydrants, and pumps. It specifies quantities and locations of fire safety equipment across various decks and compartments. Additionally, it includes information on portable fire extinguishers and other fire-fighting tools available on board.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

FUNNEL

MV. NOAH GRACIA SYMBOL

FIRE
DESCRIPTIONS

BOX FOR FIRE CONTROL PLAN 2


QUANTITY
DECK E/R TOTAL

- 2
FIRE CONTROL PLAN
DAMPER X2 PLAN
M
w
F FIRE STATION 1 - 1
w
IMO No. 9425801
SCALE 1:300 FL FIRE LOCKER

INTERNATIONAL SHORE
2 -

-
2

w CONNECTION FLANGE
WATER FIRE EXTING. SYSTEM
1 1
w 50 mm - Deck 13 - 13
w w w FIRE
HYDRANT 50 mm - E/R - 5 5
w 40 mm - ACCOMM 7 - 7
w w w w
FIRE HOSE WITH COMBINED 1 1
w w w w BOSUN STORE FOG/JET NOZZLE -

L.
WR (COUPLING : NAKAJIMA) 50 mm x 20 m 50 mm x 20 m

(RACK) HOSE LENGTH ---20 m (DK.) - 5 5


15m (E/R)

C.
50 mm x 15 m50 mm x 15 m
)

(S)
(P
FF

A-60
.T. (S) S) & S) 20m (ACCO.)

.T.
. W .T. T.
(
.T (P&
S)
.T (P&
S) B.T (P .T (P&
S)
B.T (P
&S)
CO 7 - 7

D.O
O. (P&S)
w ..W B (P&S)
R
F . Ww D.
.O.T T.S ..W B T .S..W T.S ..W B T .S..W
.O.T

.1
DR 2
O.2 F NO.5 T.S NO.3 NO.2 NO.1
O. O.1 F NO.4

NO
50 mm x 25 m 50 mm x 20 m
N N N NOZZLE SIZE DECK, E/R - 9 mm
7 - 7

. (S)
2ND DECK . WR
B.W ACCOMM. - 2 mm
(BOX)

F.O.T
L.W.L L.W.L 40 mm x 20 m 40 mm x 20 m

T
T. )
. (P

T.

NO. 3
T
w

P.
P.
-

PUMP S E
T ISOLATING VALVE FOR MAIN
W. 1 1

SE
EM. FIR
A.
AY (S)

.&
R LINE

V
G FF

ER
CO
w

.S
w DISCHARGE VALVE
2 - 2

F.O
3RD DECK
NO.5 CARGO HOLD NO.4 CARGO HOLD NO.3 CARGO HOLD NO.2 CARGO HOLD NO.1 CARGO HOLD FOR WATER SPRAY NOZZLE
(W.B.) W

WATER SPRAY NOZZLE (N=2) 1set - 1set

T.
FIRE & BILGE PUMP

P.
3 - 1 1

F.
ENGINE ROOM (100/205m /hx65/20mTH)
C.W.T

w w &S) S) &S) &S) &S)


B.T (P .T (P& B.T (P B.T (P B.T (P FIRE & G.S. PUMP
NO.5
B TM. W BTM.
WB
NO.3
BTM.
W
BTM.
W
NO.1
BTM.
W
(100/205m3
/hx65/20mTH) - 1 1
NO.4 NO.2
EMERGENCY FIRE PUMP
S.C B.W. B.W. B.W. B.W.
(80m3/hx75mTH) 1 - 1
B.L B.L
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 5kg DRY POWDER
PORTABLE FIRE EXTINGUISHER5 5 10
P
A.P F.P. 5 KG

BOAT DECK LOW. BRI. DECK UPP. BRI. DECK NAV. BRI. DECK 9L FOAM PORTABLE
PASSAGE
F
9L FIRE EXTINGUISHER 4 9 13
A GALLEY WHEELHOUSE.
WR EXHAUST A
40 kg DRY POWDER
w A
BZ ELECT RM.
A BZ PASSAGE
COMP DECK P
40 KG
FIXED TYPE FIRE EXTINGUISHER - 1 1
L.R PASSAGE
(25P) A A
PASSAGE
P MUSTER A 23 kg DRY POWDER SEMI
PORTABLE FIRE EXTINGUISHER - 1 1
CO2
5 KG STATION
WR
BZ 6.8 kg P
23 KG
E/G BZ BZ BZ w w
w 23 kg DRY POWDER SEMI
PORTABLE FIRE EXTINGUISHER - 1 1
WR
M. GALLEY ELECT LAV. F
CREW'S
.R COOK C/STEW. OIL (C) C/ENG. 20 L
G RG
.G
EN
CREW'S
SMOKE RM. PANEL 3/ENG 2/ENG
BED RM. WR

A EME MESS RM. BZ LAV.


NO.3 OIL (B)
LAV.
23 kg DRY POWDER SEMI
COMM
ENG. RM.
M BZ
C/ENG.
DAY RM.
F
9L BATT RM.
A
CO2
6.8 kg
PORTABLE FIRE EXTINGUISHER 2 1 3
FVD-R-3 TOL (1)
BATT.RM.
OIL (A)
V.T. BZ E.C.T
BOND.
LKR. ELECT
LAV. 1/ENG
BED RM.
(NO COVER)
A SL REFILLS FOR PORTABLE FIRE
M.M.
E.P.H RM. EXTINGUISHER
P ENGINE. SHIP'S MUSTER STATION
No.1 OIL
OFF'S
1/ENG BZ BATT
A-60
MON
LIFE BOAT (25P) LAUNDRY
9L FOAM : 6 SETS 1/2 -

A-60
5 KG RM. OFFICE CREW'S DAY RM. RM. NAV.
SPARE *1
F OFF'S 1. PILOT TOOL
A 5 kg DRY POWDER : 5 SETS
A-60

GALLEY OPERATION FUNNEL LOCKER


CL CL CL CL
10 20 30
9L
SPACE FOR
FUNNEL
DAMPER 10 20
SPARE

30
CL
10 20
C/OFF.
DAY RM.
30 10 NAV &
A-60

20
WHEELHOUSE

30 10 20 30
(UPP BRIDK.)
6.8 kg CO
2 : 1 SETS SET 1
F CREW'S LAV. RADIO LKR

AIR COND.
LAUNDRY

CREW'S LAV
F
BZ LAV.
LAV. C/OFF.
LAV. BED RM. BZ
*2 9L FOAM : 6 SETS 1/2 - SET
ROOM CONF. RM. BOSUN 9L
FIRE
LOCKER
(UPP DK.) 5 kg DRY POWDER : 5 SETS
A
OFF'S
PANTRY D.T D.T E/OFF.
LKR.
LAV. CAPT.
BED RM
6.8 kg CO
2 : 1 SETS SET
V.T. V.T.
BZ AB. SN. (A)
D.T.
FRESH AIR
INTAKE FOR A w FIREMAN'S EQUIPMENT
NO.2
GEN A/C A SAFETY LAMP
A ENG. RM.
M AB. SN. (B) LAV. LAV. CAPT.
FL FIREMAN'S AXE 2 - 2
OFF'S DINNER RM & LOUNGE DAY. RM.
FVD-R-5
FVD-R-2
WR
w PROTECTIVE CLOTHING
FRESH AIR
INTAKE FOR AB. SN. (C) BZ 3/OFF 2/OFF
BOOTS, GLOVES, HELMET
S.M (B) S.M (A) LKR
GALLEY AC A (1)
A NO.1 WR

ENG. RM.
M
SELF-CONTAINED BREATHING
APPARATUS WITH 30m LIFE LINE
AIR CYLINDER PER ONE SET 2 - 2
FVD-R-4 WHEEL SANITARY
HOUSE
GALLEY
A L.R RESCUE BZ A EXH.
A
(25P) BOAT (6P) BZ A WORKING --- 200L x 1
WR BZ SPARE------- 1200L x 2
w FVD-R-1

EMERGENCY ESCAPE 2 6
BREATHING DEVICE 2 (SPARE) 11
1 (TRAINING)
OFF'S & CREW
CHANGE ROOM UPPER DECK MANUAL CLOSING OF FIRE
A
PASSAGE w TALLY
OFFICE
DAMPERS /HATCHES IN 25 - 25
BZ PILOT ASSIST LADD. ACCOMM. & SERVICE SO
DK. STR.&
WR
MANUAL CLOSING OF FIRE
P M
5 KG
WORKSHOP
NO.5 L. S. W. B. T. (P) NO.4 L. S. W. B. T. (P)
(P) (P)
DAMPERS /HATCHES IN
MACHINARY SPACES
- 7 7
. T. .
. B. T
WR

S. W. B .S. W MANUAL CLOSING OF FIRE


(P) (P) T. T C
T T NO.3 NO.2 DAMPERS /HATCHES IN CARGO 25 - 25
F. O. F. O. NO.3 CARGO NO.3 CARGO SPACES
NO.2 NO.1 HOLD HOLD w
F C C
. (P)
9L . W. B. T A
FIRE
PLAN
NO.1 T.S FIRE DAMPER IN VENT DUCT 7 - 7
ACE.
BOTT. RM TALLY
DECK MEAT ESC
OXY. STORE
OFFICE
TR.
F NO.5 CARGO NO.5 CARGO NO.4 CARGO NO.5 CARGO NO.2 CARGO NO.2 CARGO
A-60
A-60 INSULATION
F BOTT. RM HOLD HOLD HOLD HOLD HOLD HOLD
& NO.1 CARGO
20L
WORK
VEG. 9L C C w C C w C C HOLD
NO.1 CARGO
HOLD
A-15
A-15 INSULATION
STEV. C
GARB.
RM.
SHOP FISH
TOL
LKR.4 C
A-CLASS WALL - - -
w FL NO.5 CARGO HATCH NO.4 CARGO HATCH A.H. NO.3 CARGO HATCH A.H. NO.2 CARGO HATCH A.H. NO.1 CARGO HATCH B-CLASS WALL
PROV. STORE (21060 x 18600) A.H. (21060 x 18600) (21060 x 18600) (21060 x 18600) (17160 x 17000)
WR
GYMNASIUM C.L.
BZ
STEER
G.RM.
OFF'S
CHANGE. RM. (12 SET) B.C.
FIRE & WASH DECK LINE - - -
A.H.
HINGED DOOR
0 R.H. 10 CREW'S 20 COMN 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 L.R. 220 230 240 A-CLASS - - -
RL
CHANGE. RM. TOL (2) (6P) R.H. FP
HINGED DOOR
ENGINE
RM.
A-60
LKR(3)
FVD-R-6
A.H.
A.H.
A.H.
A.H.
B-CLASS - - -
STEER WR
G.RM.

- - -
FIRE DECK
V.T V.T STATION STORE A-CLASS HINGED SELF CLOSING
AIR COND.
ROOM A-60 NO.1 CARGO NO.1 CARGO FIRE DOOR
NO.5 CARGO NO.5 CARGO NO.4 CARGO NO.4 CARGO NO.2 CARGO NO.2 CARGO HOLD HOLD
LAV. C C C.L.
HOLD HOLD HOLD HOLD HOLD HOLD

WR W
FVD-S-7 C C C C C C
B-CLASS HINGED SELF CLOSING
FIRE DOOR
- - -
PAINT STORE HOSPITAL
QUANTITY
w w SYMBOL DESCRIPTIONS
FIRE w
(S)
w
NO.3 CARGO NO.3 CARGO
w (S)
w DECK E/R TOTAL A-60 STEEL DECK - - -
(S) (S)
WR PLAN
HOLD HOLD . (S)
T F. O.
T C . C . B. T SWITCH
OFF'S & CREW
CHANGE ROOM
w NO.2
F. O. NO.1 T .S. W
. B. T
NO.2
T.S.
W
W. B
. T.
FOR GENERAL ALARM 2 - 2 A-15 STEEL DECK - - -
NO.3 T.S.
P
1
NO.
WR
PAINT 5KG
STORE

w NO.5 L. S. W. B. T. (S) NO.4 L. S. W. B. T. (S)


MANUALLY OPERATED CALL 10
POINT FOR GENERAL ALARM
6 16 PRIMARY EMERGENCY - - -
PAINT ESCAPE ROUTE
STORE
FIRE
WR
STATION
A
HOSPITAL
A
F FIRE DETECTOR
(SMOKE TYPE) 12 18 30 SECONDARU EMERGENCY
ESCAPE ROUTE - - -
P
FIRE STATION w F

2ND DECK
5 KG
BZ
A
FIRE DETECTOR
- 3 3 G EMERGENCY GENERATOR 1 - 1
(SPARE : 2) (HEAT TYPE)
EMERGENCY SWITCH BOARD1 - 1
(TRAIN : 1)
SL
3RD DECK FLOOR DECK FIRE DETECTOR
CO2
A M F
HEF
SL

(FLAME TYPE) - 3 3
w
6.8 kg REMOTE STOP OF VENTILATOR
FIRE & A FAN FOR ACCOMMODATION 2 - 2
WR

. (P
) HEF
FIRE & BILGE PUMP
G.S. PUMP
SL MAIN CONTROL PANEL FOR LOCAL
APPLICATION FIRE EXITING, SISTEM
1 - 1 SPACE
W.T
GR
AY F
(P) w BOS'N F'CLE DECK REMOTE STOP OF VENTILATOR
P
5 KG (P )
9L
TER
TK.
STR. SL
FAN FOR MACHINARY SPACE, 1 - 1
F.O
.T.
K (P
) G RA
Y WA
K (P
) P
WR

ER T
K. (P
) C ALARM MONITORING SYSTEM FOR 1 -
LOCAL APPLICATION FIRE EXTING SYSTEM
1 M
F.O & LO. PUMP
.3 T T 5KG WAT MONI
NO .O. .O. GRA
Y
REMOTE START/STOP BUTTON
RL .3 F .3 F
NO NO FOR NO.1 ENG. ROOM VENT 1
SL
120 BELL FOR LOCAL APPLICATION - 7 7 F
FAN
- 1
A-60

A-60
A-60

FIRE EXTING. SYSTEM


.
)

CT

WORK SHOP
(P

E.T SL
E.T BOS'N
E LE

REMOTE STOP OF E/G RM.


.T.

F
STR.
OR & E
.W

F
C WXHAUST DAN & ELECTRIC 1
w - 1
FR

PUSH BUTTON FOR LOCAL APPLICATION


- 7 7
ST NG.

SL E/G
F F
FIRE EXTING. SYSTEM HEATER WITH CIRCULATION FAN
E

(N=4)
F F
.C
L.S

9L
ENG. CONT. RM. F
w EMERGENCY SHUT-OFF
H.B.W WATER MIST NOZZLE FOR LOCAL
- 19 19 2 - 2
SL
F SL
DEVICE FOR F.O.V
FIRE STATION
.
T.

ET

F
APPLICATION FIRE EXTING. SYSTEM
ST. GEAR. RM
G
BIL

WR
F
SL SL F C.L.
(N=4)
RL
9L RL
B.C.
SL AUTOMATIC SELECTION VALVE UNIT FOR
LOCAL APPLICATION FIRE FIGHTING - 1 1 REMOTE START/STOP BUTTON
2 - 2
A-60

F.O OFERFLOW TK.


.
.

P.

EN
EN

RL
FOR FIRE & BILGE PUMP
M.L & ESC

R.T SL (NO.3 D/GEN.)


T . SYSTEM SET SET
.
OP
OP

B.W

(N=2)
MP
SL
F
.O. SU
EMERG /E L
0 10 20 30 0 FIRE 10 SL
20 30 10 M 20 30 220 A.H. 230 240 F CONT. PANEL FOR HIGH EXPANSION
F
1 - 1 REMOTE START/STOP BUTTON
A.

FOR EMERGENCY FIRE PUMP - - -


.G

PUMP
E.S

A.P 9L A.P R.H.


E
E

F FP FOAM FIRE EXTINGUSIHING SYSTEM


GIN
GIN

SPACE
IN C ING
P.

(NO.2 D/GEN.)
TO UPP. DK. HULL PART
DRA CLEAN
OM

(N=2)
BOS'N
EN

6.8 kg
EN

WASTE OIL T.
. T.

CO2 STR.
F.O

F
C
1 1
SL
SL
FOAM LIQUID TANK AND PUMP
-
A-60
A. P

w AUDIO VISUAL AUTOMATIC


1 - 1
SL
SL
HEF
H.B.W RL
) F
W (NO.1 D/GEN.)
SL FIRE ALARM PANEL
. (S
WR
(N=2) BOS'N HEF
.T C.L.
.C

120 BELL FOR HIGH EXPANSION


- 1 1
H.S

.W L
OI K
STR.
C 120 OR 200 BELL
OR O.

TT O.

F
DR L. . T
RL FOAM GEN. DISCHARGE ALARM
ST /E L.

SE E L.
G/ T

8 1 9
.T
.

CY TOR FOR GENERAL/FIRE ALARM


G

w
K.
TT. O.

S
GT
TK.
SE STE

SLUDGE TK.
LDIN
HO GE
WA

BIL

FR. EMERG. F.P FROM MAIN FIRE PUMP .


.O AIR HORN FOR HIGH EXPANSION FOAM
2 T(S)
E L .T
M/ TOR
WR HEF
- 2 2 ELECT HORN FOR GENERAL
4 - 4
SETT.T

)
F.O.SER LFUR

) . (S GENERAL DISCHARGE ALARM


V .T

EMERG. FIRE
(S S
ALARM/FIRE ALARM
S)

.O T
NO .O. O.
(S)

.T

EL T
LOW SU

O. . T
PUMP COF
.T(

F.
H.F.O.

M/ ETT.
COFF

SERV

F (S)
D. ERV BOS'N
.O.T

D .3
H.F.O.
F.O

F
P
1 1
SL
P
40 KG 5KG 9L S
S NO
STR. SPACE PROTECTED BY HIGH EXPANSION RL ELECT HORN WITH ROTATING
- SET SET
.3F
.1

C F
LAMP FOR GENERAL ALARM -
COF FOAM FIRE EXTING, SYSTEM 7 7
NO

F. (S
NO

)
F
9L
P
23 KG
F
9L /FIRE ALARM
F COF
F. (S
SL F
CO2 FIRE EXTING. SYSTEM FOR BUZZER FOR GENERAL/FIRE
9L
)
(NEAR F.O. PURIFIER)
GALLEY RANGE EXHAUST DUCT 1 - 1 BZ ALARM 20 - 20
(PURIFIER)
(N=2)