0% found this document useful (0 votes)
29 views1 page

79 111000 4800001178 RFX PLD Asb 500002 - A01

The document outlines the plumbing and drainage layout for the Terminal A upgrade at NEOM, including various pipe types and connections. It specifies dimensions, material grades, and coordination requirements with architectural and mechanical drawings. Additionally, it includes notes on the connection of waste and vent pipes to the nearest lines and discharge areas.

Uploaded by

Mohammad Osman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views1 page

79 111000 4800001178 RFX PLD Asb 500002 - A01

The document outlines the plumbing and drainage layout for the Terminal A upgrade at NEOM, including various pipe types and connections. It specifies dimensions, material grades, and coordination requirements with architectural and mechanical drawings. Additionally, it includes notes on the connection of waste and vent pipes to the nearest lines and discharge areas.

Uploaded by

Mohammad Osman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6

GENERAL KEY PLAN:

TERMINAL A KEY PLAN:

N
QIBLA
LEGENDS & SYMBOLS
Terminal A Upgrade
WASTE PIPE
SOIL & WASTE PIPE
VENT PIPE

WP WASTE PIPE PD PARKING DRAIN


SP SOIL PIPE TD TRENCH DRAIN
VP VENT PIPE IL INVERT LEVEL
CDP CONDENSATE DRAIN PIPE AFC ABOVE FALSE CEILING
FD FLOOR DRAIN BOP BOTTOM OF PIPE

* Way finding and Signage to be confirmed


WS WASTE STACK F/A FROM ABOVE
SS SOIL STACK T/A TO ABOVE
VS VENT STACK F/B FROM BELOW
CDS CODENSATE DRAIN STACK T/B TO BELOW
SD STORM DRAIN STACK H/L HIGH LEVEL
FFL FINISH FLOOR LEVEL L/L LOW LEVEL
HWB HAND WASH BASIN BFS BELOW FLOOR SLAB
FD-1 FLOOR DRAIN BOS BOTTOM OF SLEEVE
FCO FLOOR CLEANOUT FS FIRE STOP/SEAL
WCO WALL CLEANOUT RWP RAIN WATER PIPE
HWC HANDICAP WATER CLOSET GT GULLY TRAP
HS 10080 EDX-2is

NOTES:
1. ALL DIMENSIONS SHOWN ARE IN MILLIMETER.
2. ALL LEVELS AND DIMENSIONS SHOULD BE COORDINATED WITH
ARCHITECTURAL AND MECHANICAL DRAWINGS.
3. STEEL MATERIAL GRADE IS :
CHS114.3*6 & CHS193.7*12 & CHS355.6*20 IS A500GrB42.
HEB400 & HEA600& HEB650 &HEB700 IS A500Gr50.
HEB400 & HEA600& HEB650 &HEB700 IS A500Gr50.
ALL OTHER IS GRADE A36.

20.0

Waste pipe to be connected to nearest Waste


Line.

Ø50 WP UT

Ø50 WP UT

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
Vent pipe to be connected to nearest out door discharge area
REFERENCE NUMBER DESCRIPTION

Ø50 WP
0m 3m 6m 9m 12m 15m
Vent pipe to be connected to nearest Vent Line.

Ø50 VP BOP=3200 H/L Ø50 WP UT

Waste pipe to be connected to nearest Waste


Line.

VISUAL SCALE 1:150 @ A0

Ø50 WP @ 2% SLOPE L/L


Ø50 VP BOP=3200
STAGE:

Ø50 WP @ 2% SLOPE L/L


4B Handover & Closed Out

A01 4B - TESTING & COMM - HANDOVER & CLOSE OUT MB 24.12.2024


REV DESCRIPTION APP DATE
PURPOSE OF ISSUE:
Ø50 WP Ø50 WP
FOR APPROVAL
CLIENT: PROJECT MANAGEMENT CONSULTANT:

B
D:\Work\Misc\Eng. Ibrahim\NEOM Bay Air Port\As Built\PLUMBING\CAD\79-111000-4800001178-RFX-PLD-ASB-500002_A01.dwg

Ø50 WP
FD
HS 10080 EDX-2is

Ø75 WP
DESIGN CONSULTANT: MAIN CONTRACTOR:
Ø110 WP Ø110 WP
Existing Soil & Waste pipe

Vent pipe to be connected to nearest out door discharge area

DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:


Ø50 WP Ø50 WP Ø50 WP Ø50 WP
DRAWN: WS 24.12.2024
CHECKED: WS 24.12.2024 CHECKED:
APPROVED: MB 24.12.2024 APPROVED:

SCALE: 1:2 SHEET SIZE: A1


DISCIPLINE NAME:
Plumbing and Drainage

Drainage Layout

PROJECT NAME:
Ø50 WP Ø50 WP Ø50 WP Ø50 WP

79-NUM TERMINAL A UPGRADED


Ø50 WP UT
Ø50 VP BOP=3200

A
Ø50 WP @ 2% SLOPE
Ø110 SP

WCO

WB WB Ø75 WP UT
FD
79
Ø110 SP
Ø50 VP BOP=3200 H/L

Ø50 WP UT

NEOM
Ø50 WP @ 2% SLOPE

KINGDOM OF SAUDI ARABIA


Ø110 SP

Ø75 WP UT
FD

Ø50 VP T/A

Vent pipe to be connected to nearest out door


discharge area @ H/L Soil & Waste pipe to be connected to nearest

REGION ASSET CODE CONTRACT CODE


Manhole.

FD FD FCO
Ø110 SP Ø50 WP Ø110 SP
26/12/2024 6:59:15 PM

Ø75 SP Ø75 SP
Ø50 WP 79 111000 4800001178
Ø110 SP Ø110 SP Ø110 SP Ø110 SP Ø110 SP
Soil & Waste pipe to be connected to nearest Manhole.
DRAWING NUMBER
ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

RFX PLD ASB 500002 A01


NEOM-NEN-PRC-010_TMP01_02.00