0% found this document useful (0 votes)
115 views10 pages

IMI-Thompson-Valves ICO3S Data-Sheet 23oct24

The document provides detailed specifications for the ICO3S 2/2, 3/2, or 5/2 poppet valve, which is an electromagnetically actuated, direct solenoid operated valve suitable for hydraulic and pneumatic applications. Key features include various port sizes, high flow rates, low power consumption, and multiple certifications for safety and environmental protection. It emphasizes the importance of adhering to specified operating conditions to prevent failures and ensure safe usage in industrial compressed air systems.

Uploaded by

shyamsupra 97
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views10 pages

IMI-Thompson-Valves ICO3S Data-Sheet 23oct24

The document provides detailed specifications for the ICO3S 2/2, 3/2, or 5/2 poppet valve, which is an electromagnetically actuated, direct solenoid operated valve suitable for hydraulic and pneumatic applications. Key features include various port sizes, high flow rates, low power consumption, and multiple certifications for safety and environmental protection. It emphasizes the importance of adhering to specified operating conditions to prevent failures and ensure safe usage in industrial compressed air systems.

Uploaded by

shyamsupra 97
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Process

Automation
Our product brands:
IMI MAXSEAL®

ICO3S 2/2, 3/2 or 5/2


Poppet Valve
Electromagnetically Actuated,
Direct Solenoid Operated

Breakthrough
engineering for
a better world
ICO3S 2/2, 3/2 or 5/2
Poppet Valve

Key Benefits

- Port Size: 1/4”... 1/2” (ISO G / NPT)


Namur or manifold
- Direct acting solenoid valve
- High flow
- Low power
- Reliable and long life, ideal for a one
time installation
- Control of pneumatic or hydraulic
operated equipment
- Certification: ATEX, IECEx, FM, CSA,
CRN, IN-METRO, NEPSI, CCOE,
KOSHA, Japan (ISHL)
- Environmental protection: NEMA 4X,
IP66/X8

Technical Features

Medium Hydraulic and pneumatic – customer to specify and confirm compatibility

Operation Direct solenoid operated poppet valves

Mounting Position Solenoid vertical

Flow 0.8 Cv … 1.7 Cv (Options up to 2.1 Cv)

1/4” & 1/2”: NPT or ISO G


Port Size
NAMUR or manifold versions

0 ... 12 bar (0 ... 174 psi)


Operating Pressure
16 bar (232 psi) on request
Media: -55 ... +90°C (-67 ... 194°F)
Temperature Ambient: See table on page 2
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).
Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L)
Materials O-rings seats & seals: high NBR
Other seal materials available on request

These products are intended for use in industrial compressed air systems Through misuse, age, or malfunction, components used in fluid power systems can fail in
only. Do not use these products where pressures and temperatures can various modes. The system designer is warned to consider the failure modes of all component
exceed those listed under »Technical features/data«. Before using these parts used in fluid power systems and to provide adequate safeguards to prevent personal
products with fluids other than those specified, for non-industrial injury or damage to equipment in the event of such failure. System designers must provide a
applications, lifesupport systems or other applications not within warning to end users in the system instructional manual if protection against a failure mode
published specifications, consult Thompson Valves Ltd. cannot be adequately provided. System designers and end users are cautioned to review
specific warnings found in instruction sheets packed and shipped with these products.
Technical Data - Standard Models with
Conduit Connection M20 X 1,5

Symbol Port Function Operating Manual ATEX Power Ambient Weight Dimension Model
Size Pressure Override/ Certification Consumption Temperature (kg) No.
(bar) Reset at 24 Vdc (W)

2 1/4 NPT 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AA1H1BS
G 1/4 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AE1H1BS
1

2 1/4 NPT 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SA1H1BS
G 1/4 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SE1H1BS
1

1/4 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AE1H1BS
V-32C-E-F
1/2 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AE3H1BS
2
2 1/4 NPT 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SA1H1BS
V-32C-EH-F
G 1/4 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SE1H1BS
1 3
1 3

22 1/4 NPT 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TA1H1BS
V-32C-ER-F
G 1/4 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TE1H1BS
11 33
1/4 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PE1H1BS
1/2 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CE3H1BS
2 1/2 NPT 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PA3H1BS
G 1/2 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PE3H1BS
1 3

Manifold 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 9 Y013AKFH1BS

3 1 2

1/4 NPT
2 2 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNAH1BS
NAMUR
G 1/4
3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNEH1BS
NAMUR
1 3

4 2 1/4 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AA1H1BS
G 1/4V-52-E-F5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AE1H1BS
51 3 NAMUR 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 14 Y015ANAH1BS
44 22 1/4 NPT 5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CA1H1BS
G 1/4V-52-EH-F
5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CE1H1BS
5511 33

4 2 1/4 NPT 5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PA1H1BS
4 2
G 1/4V-52-EH-F
5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PE1H1BS
51 3
51 3
1/4 NPT 3/2 UNI 0…16 ALB Ex II 2 GD, Exd IIC 3 T6 (-60…+50°C), T4 (+90°C Max) 2.2 15 Y013BA1H1BS140
‘B’
‘C’
‘A’

*1) PBMR = Push button manual reset, PBMO = Push button manual override, JSMO = Jack screw manual override,
TPMR = Tamperproof manual reset button, ALB = Automatic latching button
ICO3S 2/2, 3/2 or 5/2
Poppet Valve

Y 1 S

Atex Certification Substitute Voltage / Signal Substitute

Ex d 0 24 V d.c. B

Ex mbe Z 50 V d.c. C

Ex ia* X 110 V d.c. D

Port Configuration Substitute 125 V d.c. E

2/2 NC 1 24 V a.c. G

2/2 NO 2 110 V a.c. J

3/2 (universal) 3 220 /240 V a.c. (240 V) M

5/2 (universal) 5 120 V a.c. T

Operation Substitute Conduit /


Signal Connection Substitute
Automatic A
20mm x 1.5mm ISO (F) 1
Automatic latching button B
1/2 NPT (F) 2
Push button manual override C
Seat / Seal Material Substitute
Push button manual reset P
Nitrile (-55° ... +90 °C) H
Tamper proof manual reset T
FKM (-20° ... +90 °C) V
Jackscrew manual override S

Port Size Substitute

1/4 NPT A1

G 1/4 E1

1/2 NPT A3

G 1/2 E3

NAMUR NA

Manifold KF

* For Zone 0 -
see separate catalogue section.
Dimensions Dimensions in mm
Projection/First angle

1 2
ø59 ø59
Y 47 Y 77
28

28
22

22
157

157
113,6

113,6
50,3

A 2

50,3
2
15,3 12
25,8

15,3 12
A

25,8
1
15,8

15,8
25,5 50
22

11
27
25,5 50
11
27
47

3 4
47 47 ø58

1 1
28

2 2
22
187

3 3
2
39

1 2
26

16

66
42
42

11 25,5
1
15,5

18
18

27
6,5

50 44 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
5 Jack screw manual override (JSMO)
Dimensions in mm
Projection/First angle

5 6

47 ø 58 47 ø 58

1 1

28
28
2 2

22
22

157
157

3 3
2 2

39
1
39

26
27
1
27,5

26

16
15
6

16
24

11 6 25
15,5

11
11 5 25,5 27
27 50
50

7 8
47 ø 58 47 ø58

1 1
28

2 2 28
22
22

187
157

3 3
2
39

1 2
26
27
6

16
15

66
42
42

11 25 1
3

3
18
18
6,5

27
13

50
44 3 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)
4 Push button manual override (PBMO)
6 Tamer proof manual reset (TPMR)
Dimensions in mm
Projection/First angle

9
47 ø58

28
2

22

157
6,5
3
2

39
1

26
25

16
ø8,8
ø5

51 38
51

47 ø 58
10 1
28

2
22

157

1
39
5,5
36

3
14

16
12

12

19,5 1,6 3 51
32 64

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)
Dimensions in mm
Projection/First angle

11 12
ø59 77
47 ø58 Y

28
2

22

177

1 77
1 49
5
4

35
12
1 W

71

58, 5
59
43

2
36

34, 5
3
20

12

1 1 ,5
50 30
12
25 51,2
11
27

47 ø58

13 1
28

2
22

177

5
4
1
59
43

2
36

3
20

11 12

50 4 30

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Manual override PBMO
4 Manual override PBMR
Dimensions in mm
Projection/First angle

14

47 ø58

28
2

22

177
5
4
1

59
5,5
46

2
34

36
3
22

12
19,6 1,6 51
3

32

15
Ø 58
47
28
22

17 8

( 4)
71
59

47
46

36

35

17
17

11
27

TITLE:
ICO3S Exd 12B
AUTOLATCH
ALL DIMENSIONS INmm XT& O
LERANCESONUNSPECIFIEDDIM ENSIO
NS W orkin
REMOVEALLBURRS, SHARPEDGES&SWARF X,XX± /X±0,5 0,1 ANGLES±0,5°
EDGES ±0,4 Progress Production
DRAW NTO : X,XX±00 ,25
,12 0,1 a3,2 LIFE C Y CLE PRODUCT
PACKING: PL0-NONE CB RITS8
IC 8A
8L8CHARACTERISTIC SIGNIFICANTCHARACTERISTIC STATE PHASE
THISDRAW INGISTHEPRO PERTYO F THIRDANGLE
SBUPC
PH
ORU
TM
IN # ##.## # ##.## THOMPSONVALVESLtd
AT N BEG
RSDO
CUM
EPNTKA
AC TG
INIO
N: P OOL E, D ORS ET, EN GLA N D
1 TSD-0010 TSD-0018 (A (B))--R
REF(A
EF E
)EN
ER
RENC
CED
ENU(B
IMM)ER
EBNSIO
N (A))--R
(B REF(A
EF )EN
ER
ER C
EN
C
(B
ED
EN
UM
IM
)ER
EB
NSIO
N
A
AN
MD
UFIS
N N
ACTO
T
UTO
RINGB
PEURCO
PIE
P
OSED
S,W
LEN
ITTO
H,O
URU
TTHSE
ED
IRFC
O
ORN
A
SN
EY
N
T LANG:EN
Conduit
15 connection 14
M20 x 1,5 or 1/2
13 NPT 12 11 10 9 8 7 6 5 4
2 External earth
Process
Automation
The information in this brochure is provided for
general informational purposes only. Specifications for
products and services are subject to change without
prior notice. IMI plc and its subsidiaries own all product
brands mentioned herein.
IMI makes no warranties or representations about
the accuracy or completeness of the content in
this brochure and assumes no liability for any errors
or omissions it may contain. We reserve the right
to modify, enhance, or discontinue any product or
service described herein without prior notification.

IMI Thompson Valves


17 Balena Close,
Creekmoor, Poole
BH17 7EF
United Kingdom

www.imiplc.com/process-automation
14007.02/24en

You might also like