NEC Faulty Report Item Description & SN - 1737

This document is a repair request for a faulty ODU PASOLink unit submitted by Alwaleed Khalid from SIM. The unit is under warranty and has been confirmed to have no visible damages or mishandling. The fault occurs frequently during commercial operation, and the ambient temperature around the unit ranges from 25 to 50 degrees Celsius.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views1 page

NEC Faulty Report Item Description & SN - 1737

This document is a repair request for a faulty ODU PASOLink unit submitted by Alwaleed Khalid from SIM. The unit is under warranty and has been confirmed to have no visible damages or mishandling. The fault occurs frequently during commercial operation, and the ambient temperature around the unit ranges from 25 to 50 degrees Celsius.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

WSL SCM #19-0075

REPAIR REQUEST FOR PASOLINK


No handwriting P.O./CONTRACT
Company Name Return address Parson In Charge e-Mail /Phone Number

Requestor of Repairing
SIM 1737 ( baghdad /R4 ) Alwaleed Khalid [email protected] / 07815900245

Part No. Name of faulty unit Ser No. Manufacture Date(M/D)


INFO of the faulty unit
NWA-058386 ODU PASOLink 34272 2017-06
Root unit(IDU) Model No. Name of root unit Ser No. Manufacture Date(M/D)
*Incase of module failure NWA-058386 ODU PASOLink 34272 2017-06
Warranty period Warranty status
Warranty information
In Warranty Out of Warranty
Replacement to New unit ✘ Acceptable Impossible (Changing of Ser No. is NOTacceptable)
✘ There is no Deformation of mechanical part (Shelf, connector, cover body , antenna port, etc)
✘ There is no Trace of burn on the faulty unit. (PCB, connector, etc)
Result of There is no Corrosion on the faulty unit. (Body, shelf, PCB,connector, etc)

appearance confirmation
✘ There is no Broken of electrical component and connector.(Including terminal of the connector)
✘ There is no other trace of mishandling or natural disaster on the faulty unit.

Detailed
Fault description

Only once Once in a few days Once in a few hours


Frequency of occurrence Frequently ✘ Continuously
Others ( )

Situation of recognition of the faulty


Testing in lab ✘ Under commercial operation After/During installation work
phenomenon Others ( )

Configuration settings
In case of IDU/Module is faulty
NHG NHG2 CPV NHP
✘ IHG IAG IAG2 IAG3
IAP
Others ( Already Faulty from WH SIM )

In case of ODU is faulty


Combination Equipment
using IF cable NEO HP NEO/a NEO/s NEO/c NEO/i
100/200/100E 100A/200A 400A 400 1000
VR2 VR4 VR10
iX iX-Advance
Others ( )

Other (In case of SX/EX/EX-A is faulty)

None

✘ 1+0 HS/SD HS/HS Twinpath


Equipment configuration 2-Way XPIC RTA
Others ( )

ODU location ✘ Connected to ANT (directly) Connected to WG On a test bench


Others ( )

TX power settings ATPC MTPC


TX power dBm
Additional information of the faulty unit

Range of ambient temperature


25 degree(C) to 50 degree(C)
around the faulty unit.

Disable to connect to LCT

TX PWR ALM APC ALM IF INPUT ALM


ALM STATUS RX LEV ALM ODU CPU ALM IF CABLE ALM
(LCT/NMS) MOD ALM MD CPU ALM DEM ALM
LOF ALM HIGH BER ALM LOW BER ALM
INPUT LOSS OUTPUT LOSS SD ALM
Others( )