0% found this document useful (0 votes)
34 views

Self Certification

The document certifies the installation of a 5.35 KW solar rooftop power plant at a specified address in Ahmedabad, completed on December 20, 2024. It includes details about the consumer, solar PV cells, inverter specifications, and test results confirming compliance with safety regulations. The installation has been tested and is deemed safe to be energized.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views

Self Certification

The document certifies the installation of a 5.35 KW solar rooftop power plant at a specified address in Ahmedabad, completed on December 20, 2024. It includes details about the consumer, solar PV cells, inverter specifications, and test results confirming compliance with safety regulations. The installation has been tested and is deemed safe to be energized.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Self-Certification for Solar Roof top Installations up to 10KW

Date:-23/DEC/
2024
This is to certify that the installation of Solar roof top power plant along with its associated equipment of capacity (no
of panels) 535 * 10 (peak wattage capacity per unit, KWp) = 5.35 KW at: 3 ,AMARPURA CO OP H SOC LTD.,
NR.DHANJIBHAI KUVO. CHANDLODIA, AHMEDABAD Has been carried out by us/me and the details of the
Installation as well as the test results are as under:

1. Details of Consumer :
Name: CHANDULAL CHUNILAL MISTRY Address: 3 ,AMARPURA CO OP H SOC LTD.,
NR.DHANJIBHAI KUVO. CHANDLODIA,
Electricity Connection No: 312643
AHMEDABAD
Application Number: NP-GJTPA24-004891759

2. Details of Solar PV cells and Invertor

No. Particular Modules Inverter


1. Make ADANI SOLAR YAAN
2. Capacity 535 WP 5.3 KW
3. No. of Modules/Invertor 10 1
4. Total Capacity 3.21 KW 5.3 KW
5. Voltage 1500 V / 535 WP 230 Volts/ 1 Ø
6. Sr No Attached Separate Sheet SYS119118125249

3. Test Results :

Earthing Insulation resistance

Earth Tester Sr no.- 358969 Megger Sr no and voltage : 9711015, 1000V

Earth Resistance values for all Earth Pits- Insulation Resistance:

1. 0.60 µΩ 3. 0.70 µΩ 1. Phase to Phase: 180 mΩ

2. 0.80 µΩ 2. Phase to Earth: 170 mΩ

The work of aforesaid installation has been completed by us on 20-12-2024 and it is to hereby declare that
a) All PV modules and its supporting structures have enough mechanical strength and it conforms to the relevant
codes/guidelines prescribed in this behalf.

b) All cables/wires, protective switchgears as well as Earthlings are of adequate ratings/size and they conforms to the
requirements of Central Electricity Authority (Measures relating to safety and electrical supply), Regulations 2010 as well
as the relevant codes/guidelines prescribed in this behalf.

c) The work of aforesaid Installation has been carried out in conformance with the requirements of Central Electricity
Authority (Measures relating to safety and electrical supply), Regulations 2010 and the relevant codes/guidelines
prescribed in this behalf. The installation is tested by us and is found safe to be energized.