LOGIC CONTROL POWER LIGHT
LOGIC CONTROL POWER SWITCH SHUTTER STATUS
SHUTTER INTERLOCK
LASER POWER LIGHT
20.87 [530.0] MERLIN ETHERNET PORT
LASER POWER SWITCH 4X n.402 [n10.2]
LASER HEAD
KEY LOCK
PENDANT
I/O
POWER CORDS
23.62 [600.0]
21.34 [542.0]
AIR EXHAUST
DO NOT BLOCK
AIR INTAKE
DO NOT BLOCK
LASER FIBER
C:\VaultWorkspace\TeleStandard\Laser\Controllers\F22\95565.dwg 7/25/2022 09:51:15
10.081 [256.1]
9.14 [232.2] 4.0 [101.6] ENVELOPE 8.0 [203.2]
MINIMUM DISTANCE
FOR FIBER RADIUS
. . NOTES:
CAUTION Logic Power Requirements
115VAC, single-phase, 1.0A, 50/60Hz STANDARD SYSTEM COMES WITH 120VAC TERMINATED POWER CORDS
230VAC, single-phase, 0.5A, 50/60Hz *50% DUTY CYCLE LIMIT FOR CERTAIN APPLICATIONS
THE ENVELOPE PROVIDES MINIMUM CLEARANCE FOR 115VAC, single-phase, 6.0A, 50/60Hz
TELESIS
TOLERANCES UNLESS OTHERWISE SPECIFIED 3RD ANGLE PROJECTION PROD. CODE/
CABLE CONNECTIONS AND AIR FLOW. IT DOES NOT Laser Power Requirements INCHES MILLIMETERS ORIGINAL JOB NO.
GUARANTEE ADEQUATE COOLING. 230VAC, single-phase, 3.0A, 50/60Hz .X DIM'S. ` .02
.XX DIM'S `.01
X DIM'S. ` 0.5
X.X DIM'S. ` 0.3
28181 River Drive
INSTALLER MUST ENSURE AMBIENT TEMPERATURE Max Voltage 254VAC .XXX DIM'S. `.005 X.XX DIM'S. ` 0.13 553 TECHNOLOGIES, INC.
Circleville, OH 43113
B FRACTIONS ` 1/64" ANGULAR DIM'S `1~
DOES NOT EXCEED SPECIFIED LEVELS. Operational Temperature 15 to 40* degC SHEET METAL PARTS TO INDUSTRY STANDARDS APPROVALS DATE
INSTALLATION DRAWING
DO NOT BLOCK INTAKE VENT OR EXHAUST.
Ambient Relative Humidity 10 to 85% non-condensing FLATNESS & PERPENDICULARITY APPLY TO MACHINED SURFACES
.001" OVER 6", .002" OVER 12", .005" 12" AND OVER DRAWN
PARTS MUST BE: This drawing contains data considered PROPRIETARY to
Telesis Technologies, Inc. It is not to be reproduced
MATERIAL
R. FRENCH 8/24/2021 F22 LASER CONTROLLER
RoHS COMPLIANT AND LEAD FREE
without written authorization from Telesis Technologies, Inc. CHECKED
NO ROLL FORM THREADS.
63
SURFACE FINISH:
BREAK ALL SHARP EDGES .015 MAX
Use of this information is limited to the purpose for
which it is submitted or presented and in no case is it R. FRENCH 01SEP21
to be used in any way DETRIMENTAL to the interests of FINISH APPROVED
DIMENSIONS APPLY AFTER PLATING
A UPDATED TEXT, ADDED NOTE, ADDED KEY LOCK RNF 9/15/2021 RNF 12401 UNLESS OTHERWISE NOTED. said Telesis Technologies, Inc.
R. FRENCH 01SEP21 B
SIZE DWG. NO. REV.
B UPDATED TEMPERATURE RATING RNF 7/23/2022 12622 NOTE: UNTOLERANCED
DIMENSIONS REFERENCING
PARTS MUST BE FREE OF IRREGULARITIES
PRIOR TO ANY SURFACE FINISH
ISSUED
Nicholas Digitally signed by Nicholas French
95565 B
REV DESCRIPTION DRAWN DATE APPROVED ECN TRUE POSITIONS ARE BASIC French
DN: cn=Nicholas French, c=US,
o=Telesis Technologies, ou=Product
Specilist ,
[email protected] 8/5/22 SCALE REF PDF YES SHEET
1
of
2
Date: 2022.08.05 14:43:07 -04'00'
1/4-20 UNC x.50[12.7] 2.402 [61.0]
1.500 [38.1] 2X M4x0.7 x.45
OPTIONAL MOUNTING HOLES
1.000 [25.4]
2.000 [50.8]
5.250 [133.3]
1.625 [41.3] .500 [12.7] .490 [12.4]
REMOVE AND DISCARD .500 [12.7]
1.250 [31.8]
NOT USED
3.000 [76.2]
EMISSION LIGHT
5.500 [139.7]
KEYSWITCH
C:\VaultWorkspace\TeleStandard\Laser\Controllers\F22\95565.dwg 7/25/2022 09:51:15
ATTACHED TO F22 PENDANT
LASER READY LIGHT
FAULT LIGHT
ATTACH TO CUSTOMER SUPPLIED 1/4-20 UNC x .50[12.7]
STOP BUTTON
MOUNTING HOLE/SURFACE.
SHUTTER OPEN LIGHT
SHUTTER CLOSED LIGHT
SHUTTER SWITCH
OPTIONAL 91273
PENDANT MOUNTING ARM
.974 [24.7]
5.072 [128.8] REF 5.065 [128.7] REF
95466 REMOTE PENDANT, FRONT PANEL
SIZE
TELESIS
DWG. NO. REV.
28181 River Drive
DRAWN
TECHNOLOGIES, INC.
R. FRENCH
Circleville, OH 43113
B
95565 B
SCALE SHEET of
ISSUED 2 2