Product Data Sheet
Product Group 30 – Pre-combustion Additives
OctamarTM HF-10 Plus
Product Description Product Benefits and typical Applications
OctamarTM HF-10 Plus is an innovative additive
containing a dispersant-stabiliser and antifoulant for Prevents issues related to fuels commingling like
Very Low Sulphur Fuel Oil (VLSFO) to: separation, sludge formation and filter clogging.
Improve fuel stability and compatibility during
blending, handling and storage,
Improves stability and compatibility of different
Disperse existing sludge formation and prevent
further agglomeration. VLSFO blends, types, qualities and fuel origin.
Improve combustion reducing unburned carbon
deposits throughout the engine and exhaust gas Improves oxidation and thermal stability.
system.
Improve fuel stability against oxidation and thermal Maintains long term fuel stability and prevents fuel
stressing
Reduce fuel injector fouling ageing.
Physical Properties Reduces fuel injector fouling.
Appearance.............................brown, reddish liquid
Density at 15°C............................................870 kg/m³ ECA requirements - prevents incompatibility during
Viscosity at 25°C…………………………...12 mPa.s fuel change-over.
Flash Point, PMCC…...........................>144ºF/61ºC
Pour Point…………………………….………..<-35°C Continuous use – for sludge reduction – cleaner
fuel handling system, engines and exhaust gas
Dosage
system.
For best results, OctamarTM HF-10 Plus should be
dosed into storage tank prior to bunkering.
Improves combustion efficiency - cleaner engines
Recommended regular dosage range: and exhaust system.
1:10,000 (1 litre per 10 tonnes of fuel) to Protects against the potential presence of biodiesel
1:15,000 (1 litre per 15 tonnes of fuel) derived Fatty Acid Methyl Ester (FAME), and
Different dosage rates maybe recommended for possible corrosion caused by high TAN fuels.
emergency use and sludge reduction, fuel stability
and injector fouling. Innospec personnel are Reduces risk of filter blocking related to potential
available to assess your specific problems and FAME use or distillate ageing.
advise a suitable product(s) and dosage program.
Dispersion & centrifugal evaluation of marine
additives under JSA standard verified by Class NK
Packaging and Storage
Reserve Stability Number (RSN) ASTM D7061-17
OctamarTM HF-10 Plus is supplied in non-returnable test verified by Class NK
25-litre pails. Store away from heat, sparks and
open flame.
ISO 9001 & 14001 certified by DNV
EU Origin
- continued overleaf -
M PDS OctamarTM HF-10 Plus Issue 8, 22 March 2021
OctamarTM HF -10 Plus
Precautionary Statement First Aid
Use only in approved manner. Do not contaminate HARMFUL IF SWALLOWED. CONTACT WITH
drinking water. Dispose of empty container in SKIN OR EYES CAN CAUSE IRRITATION.
accordance with local, state and federal rules. Do KEEP OUT OF REACH OF CHILDREN!
not re-use empty container. Avoid inhalation of
fumes. When handling, use rubber gloves and SKIN: Flush with water and wash with soap and
face shield, wash after handling. Consult Innospec water. Remove contaminated clothing. Get
for questions and specific directions for use. medical attention if irritation continues.
Buyer assumes all risks of storage or handling of EYES: Flush with cool water for at least 15
this material that are not in strict accordance with minutes and get medical attention immediately.
directions given. Consult the SDS for additional
information. Store in a dry place away from food INHALATION: Remove affected person to fresh
stuffs with the lid tightly closed. For commercial air. Get medical attention immediately.
use only. INGESTION: Do not induce vomiting. Drink large
amounts of water. Do not give an unconscious
person anything to drink. Get medical attention
immediately.
For further information about our products & services please contact your nearest
Innospec Customer Service Centre:
North America Greece, Turkey
Marine Specialties Marine Specialties
Customer Service Centre - USA Customer Service Centre - Greece & Turkey
8310 South Valley Highway, Suite 350 11, II Merarchias Street,
Englewood, Colorado 80112 Piraeus - 185 35
USA Greece
Tel: +1 303-792-5554 Tel: +30 210 411 0727 / 8
In USA & Canada: 800-873-8711 Fax: +30 210 411 0748
e-mail:
[email protected] e-mail:
[email protected]Europe, Middle East, Africa Asia Pacific
Marine Specialties Marine Specialties
Customer Service Centre - EMEA Customer Service Centre - Asia Pacific
P.O. Box 53156 47 Scotts Road, #02-03 Goldbell Towers
3301 Limassol Singapore 228233
Cyprus Tel : +65 6336 6286
Tel: +357 25 762 535 Fax : +65 6336 1692
Fax: +357 25 762 545 e-mail:
[email protected]e-mail:
[email protected] The information contained in this document is provided free of charge and is based on technical data that Innospec believes to be reliable. It is intended
for use by persons having technical skill and at their own discretion and risk. Innospec accepts no liability for any loss, damage or expense arising from, or
in connection with, the use of the information. Furthermore, none of the contents of this publication should be taken as a licence to operate under any
patent, nor as a recommendation to infringe any patent.
M PDS OctamarTM HF-10 Plus Issue 8, 22 March 2021