0% found this document useful (0 votes)
33 views17 pages

D4NS D4NS-SK Datasheet en 201507 C23I-E-01 Rev8

The D4NS/D4NS-SK Safety-door Switch is a multi-contact, labor-saving device designed for enhanced safety with various contact configurations and environmental compliance. It features standardized gold-clad contacts, M12-connector models for easy replacement, and conforms to ISO 14119. The document provides detailed specifications, model structures, ordering information, and safety precautions for use.

Uploaded by

Nataniel Rangel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views17 pages

D4NS D4NS-SK Datasheet en 201507 C23I-E-01 Rev8

The D4NS/D4NS-SK Safety-door Switch is a multi-contact, labor-saving device designed for enhanced safety with various contact configurations and environmental compliance. It features standardized gold-clad contacts, M12-connector models for easy replacement, and conforms to ISO 14119. The document provides detailed specifications, model structures, ordering information, and safety precautions for use.

Uploaded by

Nataniel Rangel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Safety-door Switch

D4NS/D4NS-SK C23I-E-02

Multi-contact, Labor-saving,
Environment-friendly, Next-
generation Safety-door Switch
• Lineup includes three contact models with 2NC/1NO
and 3NC contact forms and MBB models in addition
to the previous contact forms 1NC/1NO, and 2NC. Slide keys
• M12-connector models are available, saving on
labor and simplifying replacement.
• Standardized gold-clad contacts provide high
contact reliability.
Applicable to both standard loads and micro-loads.
• Variety of metallic heads available.
• Conforms to ISO 14119.

Be sure to read the “Safety Precautions” on page 13.

Safety Door Switchs


For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.

Model Number Structure


Model Number Legend
Switch (Standard type) Switch (High pull-force type)

D4NS-@@@ D4NS-@@F-SJ
1 2 3 1 2
1. Conduit/Connector size 1. Conduit size
1:Pg13.5 (1-conduit) 2:G1/2 (1-conduit)
2:G1/2 (1-conduit) 4:M20 (1-conduit)
4:M20 (1-conduit) 2. Built-in Switch
6:G1/2 (2-conduit) A:1NC/1NO (slow-action)
8:M20 (2-conduit) B:2NC (slow-action)
9:M12 connector (1-conduit) C:2NC/1NO (slow-action)
2. Built-in Switch D:3NC (slow-action)
A:1NC/1NO (slow-action)
B:2NC (slow-action)
Operation Key
C:2NC/1NO (slow-action)
D:3NC (slow-action)
E:1NC/1NO (MBB contact)
D4DS-K@
F:2NC/1NO (MBB contact) 1
1. Operation Key Type
3. Head Mounting Direction 1:Horizontal mounting
F:Four mounting directions possible (Front-side mounting at
2:Vertical mounting
shipping)/plastic
3:Adjustable mounting (Horizontal)
D:Four mounting directions possible (Front-side mounting at
5:Adjustable mounting (Horizontal/Vertical)
shipping)/metal
Note: An order for the head part or the switch part alone cannot be
accepted. (The Operation Key is sold separately.)

1
D4NS/D4NS-SK
Ordering Information
Switches (Operation Keys are sold separately.) : Models with certified direct opening contacts.
Consult with your OMRON representative when ordering any models that are not listed in this table.
Type Contact configuration Conduit opening/Connector Model
Pg13.5 D4NS-1AF *
1NC/1NO G1/2 D4NS-2AF *
M20 D4NS-4AF
Pg13.5 D4NS-1BF *
2NC G1/2 D4NS-2BF *
M20 D4NS-4BF
Slow-action
Pg13.5 D4NS-1CF *
2NC/1NO G1/2 D4NS-2CF *
M20 D4NS-4CF
1-Conduit
Pg13.5 D4NS-1DF *
3NC G1/2 D4NS-2DF *
M20 D4NS-4DF
Pg13.5 D4NS-1EF
1NC/1NO G1/2 D4NS-2EF
Slow-action MBB M20 D4NS-4EF
contact Pg13.5 D4NS-1FF
2NC/1NO G1/2 D4NS-2FF
M20 D4NS-4FF
G1/2 D4NS-6AF
1NC/1NO
M20 D4NS-8AF
G1/2 D4NS-6BF
2NC
M20 D4NS-8BF
Slow-action
G1/2 D4NS-6CF
2NC/1NO
M20 D4NS-8CF
2-Conduit
G1/2 D4NS-6DF
3NC
M20 D4NS-8DF
G1/2 D4NS-6EF
1NC/1NO
Slow-action MBB M20 D4NS-8EF
contact G1/2 D4NS-6FF
2NC/1NO
M20 D4NS-8FF
1NC/1NO D4NS-9AF
Slow-action
1-Conduit, with 2NC D4NS-9BF
M12 connector
connector
Slow-action MBB
1NC/1NO D4NS-9EF
contact
G1/2 D4NS-2AF-SJ *
1NC/1NO
M20 D4NS-4AF-SJ *
G1/2 D4NS-2BF-SJ *
2NC
1-Conduit M20 D4NS-4BF-SJ *
Slow-action
(High pull-force type) G1/2 D4NS-2CF-SJ *
2NC/1NO
M20 D4NS-4CF-SJ *
G1/2 D4NS-2DF-SJ *
3NC
M20 D4NS-4DF-SJ *
* Models with Korean S-mark certification.

2
D4NS/D4NS-SK

Operation Keys
Type Model
Horizontal mounting
D4DS-K1

Vertical mounting
D4DS-K2

Adjustable mounting
(Horizontal)
D4DS-K3

Adjustable mounting
(Horizontal/Vertical)
D4DS-K5

Slide Keys
Applicable Door
Appearance Specifications Contents Model
Switch

Weight: 422 g Slide Key: 1


D4NS
Mechanical durability: Auxiliary mounting bracket: 1 D4NS-SK01
1-conduit type
20,000 operations min. Receptacle bracket: 1

Slide Key: 1
D4NS mounting tool: 1
Inner lever: 1
Weight: 2,800 g Inner lever mounting screws: 2
D4NS
Mechanical durability: Door Switch mounting one-way screws: 2 D4NS-SK30
1-conduit type
20,000 operations min. Switch protective cover: 1
Switch protective cover screws: 4
Disable-prevention cover
(already mounted on Slide Key): 1

3
D4NS/D4NS-SK

Slide Keys
D4NS-SK01
Configration

Ideal for 20 x 20-mm


aluminum frame doors
D4NS-SK01 D4NS 1-conduit type

Can be mounted directly to a


20 x 20 mm aluminum frame.

Can be mounted directly to a


20 x 20 mm aluminum frame.

1 Release door lock.

4 Lock door.
2 Open door.

3 Close door.

Note: The D4NS-9AF Safety-door Switch


(with M12 connector) is sold separately. Note: Assess risk before implementing
safety measures for the equipment.

4
D4NS/D4NS-SK

D4NS-SK30
Configration

For safety measures


on large doors

D4NS-SK30 D4NS 1-conduit type

Close door.

Magnetic catches prevent the


operator from accidentally
opening the door.

Operation display
Open door. window lets you visually
confirm Key insertion.

The handle-shaped fixture makes it easy


to use the Door Switch.

L-shaped key
guard prevents
Key from being
damaged.

Open door.
Set the disable-
prevention cover
with a pad lock to
prevent an operator
from disabling the
open condition.

ANSI/RIA R15.06-1999 8.4 Protection of personnel within the safeguarded space


Personnel required to perform tasks within the safeguarded space shall be protected by:
a) Preventing the re-initiation of any motion or hazardous process while personnel are within the safeguarded space, for example locking a gate open;

5
D4NS/D4NS-SK
Specifications
Standards and EC Directives Direct opening travel *4 10 mm min.
Conforms to the following EC Directives: Contact resistance 25 mΩ max.
• Machinery Directive Minimum applicable load *5 1 mA resistive load at 5 VDC (N-
• Low Voltage Directive level reference value)
• EN50047 Rated insulation voltage (Ui) 300 V
• EN60204-1 Rated frequency 50/60 Hz
• EN ISO 14119
• GS-ET-15 Protection against electric Class II (double insulation)
shock

Certified Standards Pollution degree (operating 3 (EN60947-5-1)


environment)
Certification body Standard File No. Impulse Between 2.5 kV
EN60947-5-1
Consult your withstand terminals of
TÜV SÜD OMRON representative voltage same polarity
(certified direct opening)
for details. (EN60947-5- Between 4 kV
UL *1 UL508, CSA C22.2 No.14 E76675 1) terminals of
CQC (CCC) GB14048.5 2003010305077330 different
Consult your polarity
KOSHA *2 EN60947-5-1 OMRON representative Between each 6 kV
for details.
terminal and
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark. non-current
*2. Only certain models have been certified. carrying
metallic parts
Insulation resistance 100 MΩ min.
Certified Standard Ratings
Contact gap 2 × 2 mm min.
TÜV (EN60947-5-1), CCC (GB14048.5) Vibration Malfunction 10 to 55 Hz, 0.75 mm single
Utilization
resistance amplitude
Item AC-15 DC-13
category Shock Destruction 1,000 m/s2 min.
Rated operating current (Ie) 3A 0.27 A resistance
Malfunction 300 m/s2 min.
Rated operating voltage (Ue) 240 V 250 V
Conditional short-circuit 100 A (EN60947-5-1)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a current
short-circuit protection device. This fuse is not built into the Conventional free air thermal 10 A (EN60947-5-1)
Switch. current (Ith)
Ambient operating −30 to 70°C (with no icing)
UL/CSA (UL508, CSA C22.2 No. 14) temperature
A300 Ambient operating humidity 95% max.
Current (A) Volt-amperes (VA) Weight Approx. 96 g (D4NS-1CF)
Rated
Carry current
voltage Make Break Make Break Note: 1. The above values are initial values.
120 VAC 60 6 2. The Switch contacts can be used with either standard loads
10 A 7,200 720 or microloads. Once the contacts have been used to switch
240 VAC 30 3
a load, however, they cannot be used to switch smaller
loads. The contact surfaces will become rough once they
Q300
have been used and contact reliability for smaller loads may
Rated Current (A) Volt-amperes (VA) be reduced.
Carry current
voltage Make Break Make Break
*1. The degree of protection is tested using the method specified by
125 VDC 0.55 0.55 the standard (EN60947-5-1). Confirm that sealing properties are
2.5 A 69 69
250 VDC 0.27 0.27 sufficient for the operating conditions and environment
beforehand. Although the switch box is protected from dust or
water penetration, do not use the D4NS in places where foreign
Characteristics material may enter through the key hole on the head, otherwise
Degree of protection *1 IP67 (EN60947-5-1) Switch damage or malfunctioning may occur.
Durability *2 Mechanical <Standard type> *2. The durability is for an ambient temperature of 5 to 35°C and an
1,000,000 operations min. ambient humidity of 40% to 70%. For more details, consult your
<High pull-force type> OMRON representative.
100,000 operations min. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
Electrical <Standard type>
500,000 operations min. (3 A *5. This value will vary with the switching frequency, environment,
resistive load at 250 VAC) *3 and reliability level. Confirm that correct operation is possible with
300,000 operations min. (10 A the actual load beforehand.
resistive load at 250 VAC)
<High pull-force type>
100,000 operations min. (10 A
resistive load at 250 VAC)
Operating speed 0.05 to 0.5 m/s
Direct opening force *4 <Standard type>
60 N min.
<High pull-force type>
80 N min.

6
D4NS/D4NS-SK
Structure and Nomenclature
Structure
D4NS-@A@, D4NS-@B@, D4NS-@E@, D4NS-@C@, D4NS-@D@, D4NS-@F@,
D4NS-@AF-SJ, D4NS-@BF-SJ D4NS-@CF-SJ, D4NS-@DF-SJ
Operation
key hole Head
The head can be mounted
in four directions.

Sealing properties
The switch casing ensures IP67

Terminal 11 Terminal 11 Terminal 12

Terminal 12
Terminal 21 Terminal 22

Terminal 31 (33) Terminal 32 (34) Terminal 31 (33) Terminal 32 (34)

Note: The 2-conduit models have the same terminal arrangement.

Contact Form Diagrams Show State with Key Inserted.

Model Contact Contact form Operating pattern Remarks

11-12 Only NC contacts 11-12 have a


Zb ON
33-34 certified direct opening
D4NS-@A@ 11 12 mechanism.
1NC/1NO Stroke
D4NS-@AF-SJ Operation Extraction
33 34 Key insertion completion
completion position The terminals 11-12 and 33-34
position can be used as unlike poles.
11-12
ON
NC contacts 11-12 and 31-32
Zb 31-32 have a certified direct
D4NS-@B@ 11 12 opening mechanism.
2NC Stroke
D4NS-@BF-SJ Operation Extraction
31 32 Key insertion
completion
completion
position
The terminals 11-12 and 31-32
position can be used as unlike poles.

Zb
11-12 NC contacts 11-12 and 21-22
11 12
21-22 ON have a certified direct
D4NS-@C@ 33-34 opening mechanism.
2NC/1NO 21 22 Stroke
D4NS-@CF-SJ Extraction The terminals 11-12, 21-22, and
Operation
33 34 Key insertion completion 33-34 can be used as unlike
completion position
position poles.
11-12 NC contacts 11-12, 21-22, and
Zb
21-22 ON 31-32 have a certified direct
11 12 31-32 opening mechanism.
D4NS-@D@
3NC Stroke
D4NS-@DF-SJ 21 22 The terminals 11-12, 21-22, and
Operation Extraction
31 32
Key insertion
completion
completion
position
31-32 can be used as unlike
position poles.
11-12
ON
Only NC contacts 11-12 have a
Zb 33-34 certified direct opening
D4NS-@E@ 1NC/1NO MBB * 11 12 Stroke mechanism.
Operation Extraction
33 34 Key insertion completion
completion position The terminals 11-12 and 33-34
position can be used as unlike poles.
11-12
Zb NC contacts 11-12 and 21-22
21-22 ON
11 12 have a certified direct opening
33-34
D4NS-@F@ 2NC/1NO MBB * mechanism.
21 22 Stroke
Operation Extraction
33 34 Key insertion completion The terminals 11-12, 21-22 and
completion
position
position 33-34 can be used as unlike poles.

* MBB (Make Before Break) contacts have an overlapping structure,


so that before the normally closed contact (NC) opens, the normally
open contact (NO) closes.

7
D4NS/D4NS-SK
Dimensions (Unit: mm)

Dimensions and Operating Characteristics


1-Conduit Models
Head cap
D4NS-1@F
D4NS-2@F 7.5
D4NS-4@F
D4NS-2@F-SJ
D4NS-4@F-SJ Model D4NS-1@F
D4NS-2@F-SJ
30.2 30.6 Operating D4NS-2@F
D4NS-4@F-SJ
15.5 characteristics D4NS-4@F
15.3
Red
Key insertion force 15 N max. 15N max.
4.4 Key extraction force 30 N max. (50N max.)
41 33.5
Pretravel (PT) 6±3 mm 6±3 mm
2.5
Total travel (TT) (28 mm) (28 mm)
Black
20±0.1 21.5
47±0.2 22±0.1 31.5 Direct opening force * 60 N min. 80N min.
55 Direct opening stroke * 10 mm min. 10mm min.
2.15±0.05R
mounting holes * Always maintain the above operating characteristics for safe use.
Two, 4+0.15
0 dia. holes
22±0.2 14.2 depth: 5
30
31

2-Conduit Models
Head cap
D4NS-6@F
D4NS-8@F 7.5

42±0.1 31.5
Model
40±0.1 30.6 D4NS-6@F
Operating D4NS-8@F
Red 30.2 21.5 characteristics
15.3 15.5
Key insertion force 15 N max.
Key extraction force 30 N max.
4.4
Black 41 9±0.2 Pretravel (PT) 6±3 mm
33.5 5.4 2.5
Total travel (TT) (28 mm)
20.5
20±0.1 Direct opening force * 60 N min.
39±0.2 25 dia. Direct opening stroke *
47 22±0.1 10 mm min.
Cap (both sides)
* Always maintain the above operating characteristics
2.15±0.05R for safe use.
14.2
42±0.2 mounting holes Two, 4+0.15
0 dia. holes
56 max. 3 30 depth: 5

1-Conduit Connector Models


Head cap
D4NS-9@F
7.5

Red
30.2 30.6 Model
Operating
15.3 15.5 D4NS-9@F
characteristics

4.4 Key insertion force 15 N max.


Key extraction force 30 N max.
41 33.5
Black
Pretravel (PT) 6±3 mm
2.5
Total travel (TT) (28 mm)
20±0.1 21.5
47±0.2 22±0.1 31.5 Direct opening force *
55 Two, 4+0.15
0 dia. holes 60 N min.
2.15±0.05R depth: 5 Direct opening stroke * 10 mm min.
mounting holes
* Always maintain the above operating characteristics
(14) for safe use.

22±0.2 M12 × 1 14.2


31 30

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.


2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before
application.

8
D4NS/D4NS-SK

Operation Keys
14 28 Angle adjustment screw
D4DS-K1 D4DS-K3 9 dia.
17.5 28 4 8 dia.
13 4.5 dia.
7 4.3

13 30 40 56
30 15 13 20°

Black
7 Four, 2.15R
2 2
6.3
15

D4DS-K2 10.5 D4DS-K5 Mounting Holes


20.9 28 24.6
6 (Enlargement)
9 28 7 22.5 Angle
4 adjustment screws 17
13.5
4.5
30 13 15
15° 8
41 30 43 55
7
2 4.3 13
Four, 2.15R 41 43
Black 18° 6.5 (7)
18

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

Slide Keys
D4NS-SK01
Main Body Auxiliary Mounting Bracket and
40 Receptacle Bracket
3 20.5

12

Auxiliary mounting bracket


36.5 55

19.5

5.5 dia. 58 65

7.5 39.5 17
2 3 3 13
Two, M4 × 6 Receptacle 45.5
Four, M5 tap screws bracket
Stroke P=0.8
40

65 70 40 45.5 60

30
45

Switch Mounting Pattern 1 Switch Mounting Pattern 2


74 max. 42.5 55 Assembled
Auxiliary mounting bracket
(included with product) 3 39.5 42 with D4NS
85
65 55
3 39.5
28 40

10
20 74 max.
45.5 3
Receptacle bracket
(included with product) 44 26
3
Assembled 58
with D4NS Two, M4 × 6 40 28 42
(included with
product) Stroke 70 60
65

60
40 30
(Stroke) 45

51 30
19.5
45

9
D4NS/D4NS-SK

D4NS-SK30

Open Door

(151)
(34) (237)
Brand Name / Model / Disable-prevention cover
(14.2) (24)
Lot No. / Country of Origin Four, 6.5 × 19 long holes
Trademark

(85)
72 66
Two, M4 56.5
(40)
(27)
(170) (168)

(45)
(58) Sliding 56.5
72 66
(85) (35.3)

17.5 17.5 20 Shot bolt


Guide
Safety Door Switch D4NS
(sold separately) Two, 6.5 × 19 long holes (32) (70)
Lever unit

(117)

8 dia. (70)

(76) (75.5)
(56.5)
4 4

25 dia.
Switch part Handle part

Closed Door

(159)
(R150)

(19)

(78) (13.7)

8 dia. (48.5)
(72)

25 dia.

10
D4NS/D4NS-SK

With Operation Key Inserted (Relationship between Insertion Radius and Key Hole)
D4NS-1@F + D4DS-K1 D4NS-1@F + D4DS-K1
(with Front-inserted Operation Key) (with Top-inserted Operation Key)
44 to 46.5
Key insertion face Horizontal key insertion
Red Horizontal key Red radius R ≥ 200
(30.6) insertion radius (15)
R ≥ 200

(15)
54.5 to 57.0 Key
Black Permissible difference Black (41) insertion face
in center lines between
the Operation Key and
key hole is ±1.
The permissible difference
in center lines between
(30.6) the Operation Key
44 to 46.5 Vertical key
insertion radius and key hole is ±1.
Key insertion face
R ≥ 200
Vertical key insertion
radius R ≥ 200
(33.5)
(8)

Permissible difference
in center lines between
the Operation Key and 54.5 to 57.0 Key
key hole is ±1. (41) insertion face

The permissible difference


in center lines between
the Operation Key
and key hole is ±1.

D4NS-1@F + D4DS-K2 D4NS-1@F + D4DS-K2


(with Front-inserted Operation Key) (with Top-inserted Operation Key)
40 to 42.5
Key insertion face Horizontal key insertion
Red Horizontal key Red radius R ≥ 200
insertion radius
(30.6)
R ≥ 200
(15)

(15)
50.5 to 53.0 Key
Black Permissible difference Black (41) insertion face
in center lines between
the Operation Key and
key hole is ±1.
The permissible difference
(30.6) in center lines between
40 to 42.5 the Operation Key
Key insertion face Vertical key
insertion radius and key hole is ±1.
R ≥ 200

(33.5) Vertical key insertion


(27.5)
radius R ≥ 200

Permissible difference (6) (8)


in center lines between
the Operation Key and
key hole is ±1. 50.5 to 53.0 Key
(41) insertion face

The permissible difference


in center lines between
the Operation Key
and key hole is ±1.

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

11
D4NS/D4NS-SK

D4NS-1@F + D4DS-K3 D4NS-1@F + D4DS-K3


(with Front-inserted Operation Key) (with Top-inserted Operation Key)
45 to 47.5
Red Key insertion face Red Horizontal key insertion
Horizontal key radius R ≥ 50
insertion radius
(30.6) R ≥ 50 40

(40±0.15)
Black 55.5 to 58.0 Key
Black insertion face (41)
Permissible difference
in center lines between
the Operation Key and
The permissible difference
key hole is ±1.
in center lines between
the Operation Key
(30.6) and key hole is ±1.
45 to 47.5 Vertical key
Key insertion face insertion radius
R ≥ 200
Horizontal key insertion
radius R ≥ 200
(33.5) (8)

Permissible difference
in center lines between 55.5 to 58.0 Key
the Operation Key and (41) insertion face
key hole is ±1.

The permissible difference


in center lines between
the Operation Key
and key hole is ±1.

D4NS-1@F + D4DS-K5 D4NS-1@F + D4DS-K5


(with Front-inserted Operation Key) (with Top-inserted Operation Key)
51.9 to 54.4 Red 43 ± 0.1
Red Key insertion face 41 ± 0.1

(30.6)

(43±0.1)
62.4 to 64.9 Key
(41±0.1)
insertion face Horizontal key insertion
Black Black (41)
radius R ≥ 50
Horizontal key
insertion radius Permissible difference
R ≥ 50 in center lines between The permissible difference
the Operation Key and in center lines between
key hole is ±1.
the Operation Key
and key hole is ±1.
(30.6) Vertical key
51.9 to 54.4
Key insertion face insertion radius
R ≥ 50
Horizontal key insertion (8)
radius R ≥ 50
(33.5)

62.4 to 64.9 Key


Permissible difference insertion face
(41)
in center lines between
the Operation Key and
key hole is ±1.
The permissible difference
in center lines between
the Operation Key
and key hole is ±1.

Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.

12
D4NS/D4NS-SK
Safety Precautions
Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/.

Indication and Meaning for Safe Use Mounting Method


Appropriate Tightening Torque
Indicates a potentially hazardous situation
• Loose screws may result in malfunction. Tighten the screws to the
CAUTION which, if not avoided, may result in minor specified torques.
or moderate injury or in property damage.
Terminal screw 0.6 to 0.8 N·m
Precautions Supplementary comments on what to do Cover mounting screw 0.5 to 0.7 N·m
for Safe Use or avoid doing, to use the product safely. Head mounting screw 0.5 to 0.6 N·m
Operation Key mounting screw 2.4 to 2.8 N·m
Precautions Supplementary comments on what to do Body mounting screw 0.5 to 0.7 N·m
or avoid doing, to prevent failure to
for Correct operate, or undesirable effect on product
Connector 1.8 to 2.2 N·m

Use Cap screw 1.3 to 1.7 N·m


performance.
• When loosening a screw with an electrical screwdriver or similar
tool while pressing down on the screw head, do not continue
<Safety-door Switch D4NS>
turning the screw past the point where the threads disengage.
!CAUTION Doing so may strip the end of the threads.

Mounting Holes
Electric shock may occasionally occur.
• Use M4 screws and spring washers to mount the Switch and
Do not use metal connectors or metal conduits.
Operation Key, and tighten the screws to a suitable torque. To
ensure safety, use screws that cannot be easily removed or
another means to prevent the Switch and Operation Key from
Precautions for Safe Use easily being removed.
• As shown below, two studs with a maximum height of 4.8 mm and
• Do not use the Switch submersed in oil or water or in locations a diameter of 4 −0.05
−0.15 mm can be provided, the studs inserted into the
continuously subject to splashes of oil or water. Doing so may holes on the bottom of the Switch, and the Switch secured at four
result in oil or water entering the Switch. (The IP67 degree of locations to increase the mounting strength.
protection of the Switch specifies the amount of water penetration
after the Switch is submerged in water for a certain period of time.) Switch Mounting Holes and Studs Operation Key Mounting Holes
• 1-Conduit Modules • Horizontal/Vertical Mounting
• Always attach the cover after completing wiring and before using
(D4DS-K1/-K2)
the Switch. Also, do not turn ON the Switch with the cover open. Two, M4
Doing so may result in electric shock. Two, M4
2.5±0.1
• Do not switch circuits for two or more standard loads (250 VAC,
3 A). Doing so may adversely affect insulation performance. 20±0.1
22±0.1 15±0.1

Stopper Installation 47±0.1


• Horizontal Adjustable
Do not use a Switch as a stopper. Be sure to install a stopper as Mounting (D4DS-K3)
shown in the following illustration to ensure that the base of the Two, M4
Operation Key does not strike the Head, and adjust the stopper to be
within the setting zone (0.5 to 3 mm) of the base of the Operation Key. 22±0.1 -0.05
4-0.15 dia.
40±0.1
Do not subject the Switch to a shock that exceeds the Switch's shock Height: 4.8 max.
resistance of 1,000 m/s2. • Horizontal/Vertical Adjustable
• 2-Conduit Modules
Two, M4 Mounting (D4DS-K5)
Correct Stopper Incorrect 2.5±0.1 Two, M4
5.35±0.1

20±0.1 41±0.1 or, 43±0.1


22±0.1
39±0.1 40±0.1
42±0.1

Operation key

42±0.1
-0.05
Switch 4-0.15 dia.
Height: 4.8 max.

• Set the Operation Key so that it is within 1 mm of the center of the


key hole. If the Operation Key is offset or at an angle, accelerated
Precautions for Correct Use wear or breaking may result.
• Observe the specified insertion radius for the Operation Key and
The Switch contacts can be used with either standard loads or insert it in a direction perpendicular to the key hole.
microloads. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The contact
surfaces will become rough once they have been used and contact
reliability for smaller loads may be reduced.

13
D4NS/D4NS-SK

Head Direction <Reference>


• The rotation of the Switch head may be adjusted to any of the four The crimp terminals listed below have a thickness of 0.5 mm or less.
directions by loosening the head mounting screws at the four
corners of the head. Make sure that no foreign materials enter Manufacture Type
through the head. FN0.5-3.7 (F Type)
• Do not insert or remove the Operation Key with the Switch head J.S.T. Mfg Co.
N0.5-3.7 (Straight Type)
removed. Doing so may make it impossible to insert the Operation
Key. J.S.T is a Japanese manufacturer.
L
Securing the Door t: 0.5 mm l F
dz dia.: 3.7 mm
When the door is closed (with the Operation Key inserted), the D dia.: 2.9 mm
Operation Key may exceed the set zone because of, for example, the B: 6.6 mm
L: 19 mm D dia. B
door's own weight, machine vibration, or the door cushion rubber. F: 7.7 mm
Secure the door with a stopper so that the Operation Key remains I: 8.0 mm

within the set zone.


dz dia.

Set zone Terminal screw


(0.5 to 3 mm)

Operation Key
Crimp terminal
Wiring
Wiring Correct Incorrect
• When connecting with insulation tubes and M3.5 crimp terminals,
Pin arrangement of connector type
connect the terminals as shown in the following figure and wire
without overriding to the case and the cover. Adequate conductor
1 D4NS-9AF (1NC/1NO)
size is AWG 20 to AWG18 (0.5 to 0.75 mm2). D4NS-9BF (2NC)
D4NS-9EF (1NC/1NO (MBB))
2 4 Zb
Prepare lead wires using the lengths given in the following 1 (11) 2 (12)
Zb
3 1 (11) 2 (12)
diagrams. If lead wires are too long, they will press against the 3 (31) 4 (32)
3 (33) 4 (34)
cover causing the cover to not close properly.
Pin No. (Terminal No.)

1-Conduit Models with 3 Poles • Suitable socket is XS2F-D421 series (OMRON).


A B C
AB

D
• Refer to the Connector Catalog for corresponding Socket pin
11 12 E F
numbers and lead wire colors.
C 21 22
D
42 mm
33 mm
E 33 34 F 28 mm Socket Tightening (Models with Connectors)
• Turn the tightening screws on the Socket by hand and tighten them
Tolerance ±2 mm
until the gap between the Socket and Plug essentially disappears.
2-Conduit Models with 3 Poles • Make sure that the Socket’s connector is tightened securely,
A B
ECA
Left hand Right hand
BD F otherwise the rated degree of protection (IP67) of the D4NS may
11 12
BD F ECA not be maintained, or the Socket connector may be loosened by
C D
21 22
42 mm 42 mm vibration.
E F 28 mm 28 mm
33 34
Conduit Opening
Tolerance ±2 mm Tolerance ±2 mm
• Use cables with suitable diameters for the connector being used.
• Do not push the crimp terminal and the likes into the opening • When wiring, place the enclosed cap screw on unused conduit
between the parts to prevent the case from being broken and openings (for 2-Conduit Switches) and tighten them to the suitable
deformed. tightening torque.
• Use terminals having the thickness of 0.5 mm or less to avoid the
contact between the terminal and the Switch case inside. Recommended Connectors
Use the connector with thread section of 9 mm long or less. If a
connector with a longer thread section is used, the protruding part
may interfere with the other parts inside the body. Use the connectors
listed below to ensure IP67 degree of protection.

Applicable cable
Size Manufacture Model
diameter
ST-PF1/2
G1/2 LAPP 6.0 to 12.0 mm
5380-1002
S-13.5
Pg13.5 LAPP 6.0 to 12.0 mm
5301-5030
ST-M20 × 1.5
M20 LAPP 7.0 to 13.0 mm
5311-1020
When use LAPP's products, use together with a Seal Packing which
is sold separately (Type names, JPK-16, GP-13.5, or GPM20) and
tighten with proper tightening torque.
• LAPP is a German manufacturer.

14
D4NS/D4NS-SK

<Slide Keys D4NS-SK01/SK30>


• Use the D4NS-SK30 only with the D4NS Safety-door Switch head
!CAUTION in the direction shown below.
Incorrect operation may cause injury. Also, the product is
designed to be mounted so that it slides horizontally.
Do not mount the product in a vertically sliding
configuration. Operation Key
(excluding the D4NS-SK01)

Precautions for Safe Use Technical Specifications


• Do not drop the Switch. Doing so may prevent the Switch from D4NS-SK30
functioning to full capacity. Ambient operating
−10 to 55°C (with no icing)
temperature
• Mount the Switch securely to prevent it from falling. Otherwise,
injuries may occur. Ambient operating
95% max.
humidity
• Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction. Mechanical durability 20,000 operations min.
• Make sure that the gap between the short bolt and guide is (±3 Weight
Approx. 2.8 kg
mm. Otherwise, excessive wear or damage may cause (not including D4NS Safety-door Switch)
malfunction. • Do not store the Switch where corrosive gases (e.g., H2S, SO2,
• To ensure safety, do not operate the Switch with anything other NH3, HNO3, or CL2) or dust are present, or in locations subject to
than a Slide Key. high temperature or humidity.
• Be careful to avoid pinching your hand when operating the Switch. • Perform maintenance inspections periodically.
• Be sure to mount the Switch protective cover. Otherwise, your • This product is for use only with OMRON Safety-door Switches.
hand may be injured by being pinched between the shot bolt and Do not use it with door switches made by other manufacturers.
Switch when closing the door with your hand on the Switch.
• When opening the door, be sure to lower the disable-prevention Mounting Holes (Unit: mm)
cover into position, attach a padlock, or take other steps to prevent
other people from operating the Switch.
D4NS-SK30
• The durability of the Switch is greatly influenced by the switching 209.5
conditions. Always test the Switch under actual working conditions 131.5
before application and use it in a switching circuit for which there
are no problems with performance. 72
56.5 66
• The user must not maintain or repair equipment incorporating the
Switch. Contact the manufacturer of the equipment for any Six, 30
56.5 66
maintenance or repairs required. 72 M6
• Do not shut the door while the shot bolt is extended. The Switch
may be damaged, preventing proper operation.
45 Two, R25 (reference)
• Do not apply excessive force in the direction of the slide. This may 20
damage the product and cause it to malfunction.
Assembly
Precautions for Correct Use
Switch part
• Insert the slide handle until the red operation indicator is
D4NS-SK30
completely displayed in the operation display window.
Switch mounting screw Disable-prevention cover
(one-way screw)
Two, M4 × 25

Normal Insufficient insertion


Operation display window

• Loose screws may result in malfunction. Use washers and tighten


the screws to the specified torques. Also, when mounting the Switch protective cover Guide
mounting screw
Switch to a door for disable-prevention purposes, purchase and Four, M4 × 6
use tamper-resistant screws.

Tightening Torque Handle part


Slide Key mounting screw (M6) 6.0 to 7.0 N·m
D4NS-SK30
Switch mounting screw
0.5 to 0.7 N·m If a burden is placed on the short bolt or guide, making
(included with product) the door difficult to open and close, adjust the mounting
Switch protective cover position within the range of the long holes.
mounting screw (included with 1.2 to 1.4 N·m
product)
Lever mounting screw
1.2 to 1.4 N·m
(included with product)

Short bolt Lever mounting screw


Two, M4 × 8

15
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
part of all quotes, agreements, purchase orders, acknowledgments, price lists, BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
catalogs, manuals, brochures and other documents, whether electronic or in PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
writing, relating to the sale of products or services (collectively, the "Products") INTENDED USE. Omron further disclaims all warranties and responsibility of
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron any type for claims or expenses based on infringement by the Products or oth-
objects to any terms or conditions proposed in Buyer’s purchase order or other erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
documents which are inconsistent with, or in addition to, these Terms. gation hereunder shall be, at Omron’s election, to (i) replace (in the form
2. Prices; Payment Terms. All prices stated are current, subject to change with- originally shipped with Buyer responsible for labor charges for removal or
out notice by Omron. Omron reserves the right to increase or decrease prices replacement thereof) the non-complying Product, (ii) repair the non-complying
on any unshipped portions of outstanding orders. Payments for Products are Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
due net 30 days unless otherwise stated in the invoice. the non-complying Product; provided that in no event shall Omron be responsi-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices ble for warranty, repair, indemnity or any other claims or expenses regarding
sent to Buyer after deducting transportation charges, taxes and duties, and will the Products unless Omron’s analysis confirms that the Products were prop-
be allowed only if (i) the invoice is paid according to Omron’s payment terms erly handled, stored, installed and maintained and not subject to contamina-
and (ii) Buyer has no past due amounts. tion, abuse, misuse or inappropriate modification. Return of any Products by
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or Buyer must be approved in writing by Omron before shipment. Omron Compa-
the maximum legal rate, whichever is less, on any balance not paid within the nies shall not be liable for the suitability or unsuitability or the results from the
stated terms. use of Products in combination with any electrical or electronic components,
5. Orders. Omron will accept no order less than $200 net billing. circuits, system assemblies or any other materials or substances or environ-
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all ments. Any advice, recommendations or information given orally or in writing,
costs involved in, obtaining any government approvals required for the impor- are not to be construed as an amendment or addition to the above warranty.
tation or sale of the Products. See http://www.omron247.com or contact your Omron representative for pub-
7. Taxes. All taxes, duties and other governmental charges (other than general lished information.
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
imposed directly or indirectly on Omron or required to be collected directly or FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
indirectly by Omron for the manufacture, production, sale, delivery, importa- LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
tion, consumption or use of the Products sold hereunder (including customs WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
duties and sales, excise, use, turnover and license taxes) shall be charged to BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
and remitted by Buyer to Omron. Further, in no event shall liability of Omron Companies exceed the individual
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory price of the Product on which liability is asserted.
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
security or payment in advance. If Buyer fails to make payment or otherwise their employees from and against all liabilities, losses, claims, costs and
comply with these Terms or any related agreement, Omron may (without liabil- expenses (including attorney's fees and expenses) related to any claim, inves-
ity and in addition to other remedies) cancel any unshipped portion of Prod- tigation, litigation or proceeding (whether or not Omron is a party) which arises
ucts sold hereunder and stop any Products in transit until Buyer pays all or is alleged to arise from Buyer's acts or omissions under these Terms or in
amounts, including amounts payable hereunder, whether or not then due, any way with respect to the Products. Without limiting the foregoing, Buyer (at
which are owing to it by Buyer. Buyer shall in any event remain liable for all its own expense) shall indemnify and hold harmless Omron and defend or set-
unpaid accounts. tle any action brought against such Companies to the extent based on a claim
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation that any Product made to Buyer specifications infringed intellectual property
unless Buyer indemnifies Omron against all related costs or expenses. rights of another party.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
resulting from causes beyond its control, including earthquakes, fires, floods, sive property of Omron Companies and Buyer shall not attempt to duplicate it
strikes or other labor disputes, shortage of labor or materials, accidents to in any way without the written permission of Omron. Notwithstanding any
machinery, acts of sabotage, riots, delay in or lack of transportation or the charges to Buyer for engineering or tooling, all engineering and tooling shall
requirements of any government authority. remain the exclusive property of Omron. All information and materials supplied
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: by Omron to Buyer relating to the Products are confidential and proprietary,
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship and Buyer shall limit distribution thereof to its trusted employees and strictly
except in “break down” situations. prevent disclosure to any third party.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and
constitute delivery to Buyer; licenses regarding (i) export of products or information; (iii) sale of products to
c. All sales and shipments of Products shall be FOB shipping point (unless oth- “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
erwise stated in writing by Omron), at which point title and risk of loss shall regulated technology or information.
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
est in the Products until the full purchase price is paid; and no course of dealing between Buyer and Omron shall operate as a waiver
d. Delivery and shipping dates are estimates only; and of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
e. Omron will package Products as it deems proper for protection against nor- without Omron's written consent. (c) Law. These Terms are governed by the
mal handling and extra charges apply to special conditions. law of the jurisdiction of the home office of the Omron company from which
12. Claims. Any claim by Buyer against Omron for shortage or damage to the Buyer is purchasing the Products (without regard to conflict of law princi-
Products occurring before delivery to the carrier must be presented in writing ples). (d) Amendment. These Terms constitute the entire agreement between
to Omron within 30 days of receipt of shipment and include the original trans- Buyer and Omron relating to the Products, and no provision may be changed
portation bill signed by the carrier noting that the carrier received the Products or waived unless in writing signed by the parties. (e) Severability. If any provi-
from Omron in the condition claimed. sion hereof is rendered ineffective or invalid, such provision shall not invalidate
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
Products will be free from defects in materials and workmanship for a period of against the amount owing in respect of this invoice. (g) Definitions. As used
twelve months from the date of sale by Omron (or such other period expressed herein, “including” means “including without limitation”; and “Omron Compa-
in writing by Omron). Omron disclaims all other warranties, express or implied. nies” (or similar words) mean Omron Corporation and any direct or indirect
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, subsidiary or affiliate thereof.
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use


1. Suitability of Use. Omron Companies shall not be responsible for conformity ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
with any standards, codes or regulations which apply to the combination of the ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
Product in the Buyer’s application or use of the Product. At Buyer’s request, OVERALL EQUIPMENT OR SYSTEM.
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the
ratings and limitations of use which apply to the Product. This information by user’s programming of a programmable Product, or any consequence thereof.
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs
uct in combination with the end product, machine, system, or other application and other materials is provided as a guide for the user in determining suitabil-
or use. Buyer shall be solely responsible for determining appropriateness of ity and does not constitute a warranty. It may represent the result of Omron’s
the particular Product with respect to Buyer’s application, product or system. test conditions, and the user must correlate it to actual application require-
Buyer shall take application responsibility in all cases but the following is a ments. Actual performance is subject to the Omron’s Warranty and Limitations
non-exhaustive list of applications for which particular attention must be given: of Liability.
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be
interference, or conditions or uses not described in this document. changed at any time based on improvements and other reasons. It is our prac-
(ii) Use in consumer products or any use in significant quantities. tice to change part numbers when published ratings or features are changed,
(iii) Energy control systems, combustion systems, railroad systems, aviation or when significant construction changes are made. However, some specifica-
systems, medical equipment, amusement machines, vehicles, safety equip- tions of the Product may be changed without any notice. When in doubt, spe-
ment, and installations subject to separate industry or government regulations. cial part numbers may be assigned to fix or establish key specifications for
(iv) Systems, machines and equipment that could present a risk to life or prop- your application. Please consult with your Omron’s representative at any time
erty. Please know and observe all prohibitions of use applicable to this Prod- to confirm actual specifications of purchased Product.
uct. 5. Errors and Omissions. Information presented by Omron Companies has been
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS checked and is believed to be accurate; however, no responsibility is assumed
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT for clerical, typographical or proofreading errors or omissions.
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON CANADA, INC. • HEAD OFFICE OMRON ARGENTINA • SALES OFFICE


Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com Cono Sur • 54.11.4783.5300

OMRON ELECTRONICS DE MEXICO • HEAD OFFICE OMRON CHILE • SALES OFFICE


México DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected] Santiago • 56.9.9917.3920

OMRON ELECTRONICS DE MEXICO • SALES OFFICE OTHER OMRON LATIN AMERICA SALES
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected] 54.11.4783.5300

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE


São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu

Authorized Distributor: Automation Control Systems


• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

C23I-E-02 07/15 Note: Specifications are subject to change. © 2015 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.

You might also like