0% found this document useful (0 votes)
34 views1 page

Latter

The document is a letter from UGTLS to SM Consultants regarding the submission of samples for testing materials used in the construction of MINREM (MICM) at Tamando, Bhubaneswar. It lists various items to be tested, including cables, railing pipes, steel bars, plywood, and flush doors, along with the specific tests to be conducted for each item. The letter requests the test report to be submitted promptly for quality inspection.

Uploaded by

Deepak Khuntia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views1 page

Latter

The document is a letter from UGTLS to SM Consultants regarding the submission of samples for testing materials used in the construction of MINREM (MICM) at Tamando, Bhubaneswar. It lists various items to be tested, including cables, railing pipes, steel bars, plywood, and flush doors, along with the specific tests to be conducted for each item. The letter requests the test report to be submitted promptly for quality inspection.

Uploaded by

Deepak Khuntia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Latter no:- UGTLS/HO/2024-25/01 Date:-28-12-2024

To
SM Consultants.
Plot No 130, S.M.Tower,
Mancheswar Industrial Estate,
Rasulgarh, Bhubaneswar,
Odisha 751010
Sub :- Submission of sample for Testing material used at site.
1. Ref No:- MCL/Samb/(civil-TC/e-Tender/23-24/01 Date 03/04/2023
2. Name of work – Balance work for construction of MINREM(MICM) at Tamando Bhubaneswar Odisha.
3. AOC No – MCL/Samb/e-Tender/AOC/23-24/168 Date 09/06/23.
Dear sir,
With reference to above subjected work, We have submitting the below mentioned material which in used at site for
obtaining test report against the work for balance work for construction of MINREM (MICM) at Tamando BBSR.
Followings items to be Tested:-
S.N. ITEM TEST TO BE CONDUCTED
01 3.5CX300 SQMM LT CABLE
02 3CX120 SQMM HT CABLE As per IS code.
03 3.5CX240 SQMM LT CABLE
Tensile strength, Yield stress & % of Elongation
04 M.S Railing Pipes
Bend test
05 S.S Railing Pipes Tensile strength, Yield stress & % of Elongation
Size & weight
Steel Bar (8mm,12mm,16mm& Tensile strength. Yield stress & % of Elongation
06 20mm) Bend &Rebent Test
Chemical Test
Heat Resistance
07 Ply wood sample Boiling Water Resistance
Adhesion of Plies
Thickness
Dimension
Squareness
Impact indentation
Slamming
08 Flush Door Bulking
Edge Loading
Shock resistance
Glue adhesion
Knife test
End immersion

The Test report may please be submitted at earliest Quality inspection.


Thanking you
Contact person
Deepak Kumar Khuntia Yours Faithfully
8319214811

You might also like