The NP308T series is a high-performance industrial-grade serial to Ethernet server that supports various configurations for RS-232 and RS-485 connections. It features 8 ports for serial communication, a 10/100Base-TX Ethernet port, and can operate in rugged environments with a wide temperature range. The device is designed for easy configuration and installation, offering both web and Telnet support, and comes with a warranty of 5 years.

Uploaded by

canpvconnect
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views5 pages

np308t Series Quicktart

The NP308T series is a high-performance industrial-grade serial to Ethernet server that supports various configurations for RS-232 and RS-485 connections. It features 8 ports for serial communication, a 10/100Base-TX Ethernet port, and can operate in rugged environments with a wide temperature range. The device is designed for easy configuration and installation, offering both web and Telnet support, and comes with a warranty of 5 years.

Uploaded by

canpvconnect
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

【Summarize】 to avoid affecting its performance.

If you find that the device is


NP308T series is an high performance, industrial grade damaged or any parts of it is missing during transportation, please
serial to Ethernet server, it can satisfy some kinds of customer notify the Company or the Company’s distributor, we will give you
requirements in consumption, temperature, volume and handle proper solution as soon as possible
ability. It included NP308T-8DI(RS-485), NP308T-8D(RS-232) and 【Feature】
NP308T-8DI(RS-485)-P(9/48VDC) 3 product, NP308T-8 Provide 8 port RS-232 or 8 port RS-485/422
DI(RS-485), NP308T-8D(RS-232) adopt DC5V power adapter Support WEB and Telnet configuration
input. NP308T-8DI(RS-485)-P(9/48VDC) adopt 9-48VDC power Support Sever and Client working mode
input(terminal block). It provides 8 port RS232 (RS-232 connector: Support TCP, UDP, ARP, ICMP, DHCP and DNS
RJ45) or RS485(RS485 connector: terminal block) and 1 port protocol
10/100Base-Tx Ethernet, can focus manage disperse serial device, Support link automatic when network cut off function
master through network, easy, convenience. In application, can Support cross-gateway and cross-router communication
configure, upgrade through WEB Provide Windows configuration tools for easy to use, easy
NP308T Series Moreover, NP308T series provide strong function to bath install
8-port RS-232/485/422 to Ethernet configuration tools based in Windows platform, it can guide user Industrial grade design, IP30 protect grade
configure the device step by step, all configurations are coming true No fan, low consumption design
User Manual by WEB or Telnet, support cross-gateway and cross-router, user Working temperature: -40-85℃
can can flexible configure IP address, server and client mode, data 【Panel design】
bag size etc.
NP308T series adopts EMC protection design, can work in
rugged environment. It provides 2 kinds of wall mounting
installation, easy to use for your project
【Packing list】
The first time use this product, please check the packaging is Front view
intact or not and the attachment is complete or not at first.
NP308T series x1
User manual x1
Straight-through cable x1
Shenzhen 3onedat Technology CO., LTD Power adapter x1
Address: 3/B, Zone 1, Baiwangxin High Technology Industrial park, CD x1
Song Bai Road, Nanshan District, Shenzhen, 518108, China Product qualified card x1
Website: www.3onedata.com Warranty card x1
Phone: +86 0755-26702688 Please handle with care for there are precision components in the
Fax: +86 0755-26703485 device, and it’s better to protect the device from excessive vibration Vertical view
5. COM1~COM8 data running statues indicator 4. Factory default button(DEF)
6. Running status indicator 5. COM1~COM8 data running statues indicator
7. Power indicator 6. Running statues indicator
8. Network connection/statues indicator 7. Power indicator
9. Installation aligning plug 8. Network connection/statues indicator
10. Mat 9. Installation aligning plug
10. Mat
NP308T-8D(RS-232) 【Dimension】
Unit(mm)

Left view Right view

Back view

1. DC power input port


2. Serial port: COM1~COM8
3. Ethernet RJ45 port
4. Factory default button(DEF)
5. COM1~COM8 data running statues indicator
6. Running statues indicator
7. Power indicator
Vertical view 8. Network connection/statues indicator
NP308T-8DI(RS-485) 9. Installation aligning plug
10. Mat 【Power input】
NP308T-8DI(RS-485) -P(9/48VDC)

Back view

2 bit terminal block input power adapter input


1. DC power input port Back view
NP308T-8DI(RS-485), NP308T-8D(RS-232) back panel provide
2. Serial port: COM1~COM8 1. DC power input port
DC power input, voltage input is, DC power adapter specification
3. Ethernet RJ45 port 2. Serial port: COM1~COM8
is internal size 2.5mm, external size 5.5mm.
4. Factory default button(DEF) 3. Ethernet RJ45 port
NP308T-8DI(RS-485)-P(9/48VDC) back panel provide DC PIN Define
power input port, plug-in type, 2bit, 5.08mm separation distance 1 D+(A)
terminal block, the power input is 9~48VDC. MDI-X (Cross over cable) 2 D-(B)
【Communication connector】 RJ45

NP308T series provide 1pcs 10Base-T/100BaseTX Ethernet port 8

1
RS-422:
(RJ45) and 8 port RS-232(RJ45)or 8 port RS-485/422(terminal
(RX+) TX+ 3 1 RX+ (TX+)
PIN Define
block). (RX-) TX- 6 2 RX- (TX-)
(TX+) RX+ 1 3 TX+ (RX+) 1 T+(A)
10/100BaseT(X) Ethernet port
(TX-) RX- 2 6 TX- (RX-) 2 T-(B)
The pinout of RJ45 port display as below, connect by UTP or
3 R+(A)
STP. The connect distance is no more than 100m. 100Mbps is used Serial port connection
4 R-(B)
100Ωof UTP 5 , 10Mbps is used 100Ωof UTP 3,4,5. NP308T-4D(RS-232) series adopts RJ45 connector. The PIN
define is as follows: 【LED Indicator】
The LED indicator on the front panel of NP304T series can indicate
RS-232 port:
1 8 the running system and the operation status, which makes it easy to
find and solve problems, the specific meaning of indicator are
shown in the table.

RJ 45 port support automatic MDI/MDI-X operation. can System status LED


PIN PIN define Description
connect the PC, Server, Converter and HUB .Pin 1,2,3,6 1 TXD Transmit data
LED Indicate Description

Corresponding connection in MDI. 1→3,2→6,3→1,6→2 are used 2 RXD Received Data ON Power is connected/Function

as cross wiring in the MDI-X port of Converter and HUB. 3 RTS Request to send natural
PWR
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin 4 CTS Clear to send OFF Power is disconnected or function

in the table as below. 5 DSR Data set ready nu-natural

NO. MDI signal MDI-X signal 6 GND Signal ground Flashing System Running steadily
1 8 1 TX+ RX+ 7 DTR Data terminal ready System did not run or running
RUN OFF
2 TX- RX- 8 DCD Data carrier detect un-steadily

3 RX+ TX+ NP308T-4DI(RS-485), NP308T-8DI(RS-485)-P(9/48VDC): ON System Running un-steadily

6 RX- TX- Back panel provide 3.81mm 4bit industrial terminal block, the ON Ethernet port connect successfully
4、5、7、8 — — PIN define is as follows: LINK Flashing Ethernet port has data transmission
Note:“TX±”Transmit Data±,“RX±”Receive Data±,“—” Not use. OFF Ethernet port connect unsuccessfully
MDI (straight-through cable) OFF None data receive
RJ45 RX1~8
8 Flashing In receiving data
1 OFF None data transmit
TX+ 3 3 RX+ RS-485: TX1~8
6
Flashing In transmitting data
TX- 6 RX-
RX+ 1 1 TX+
RX- 2 2 TX-
Cables, power lines and grounding lines cannot be overlapped 【Specification】
【Installation】 and mixed when they are in the same groove road. When Ethernet port
Before installation, confirm that the work environment meet the cable is too long, it cannot hold down other cable, but Standard: 10Base-T, 100Base-TX
installation require, including the power needs and abundant space. structure in the middle of alignment rack; Protocol: Support TCP, UDP, APR, ICMP and DHCP
Whether it is close to the connection equipment and other 8. Pigtail cannot be tied and swerved as less as possible. Signal: Rx+, Rx-, Tx+, Tx-
equipments are prepared or not. Swerving radius cannot be too small (small swerving causes Speed: 10/100Mbps
1. Avoid in the sunshine, keep away from the heat fountainhead or terrible loss of link). Its banding should be moderate, not too Working: Full-duplex and half duplex
the area where in intense EMI. tight, and should be separated from other cables; Working mode: Support TCP Server and Client
2. Examine the cables and plugs that installation requirements. 9.it should have corresponding simple signal at both sides of Transfer distance: 100m
3. Examine whether the cables be seemly or not (less than 100m) the cable for maintaining. Serial port
according to reasonable scheme. Serial port number: 8 port RS-232 or 8 port RS-485/422
4. Screw, nut, tool provide by yourself. RS-232 signal: DCD, RXD, TXD, DTR, GND, DSR, RTS,
5.Power need: 5VDC power inputs CTS
6. Environment: -40°C to 75°C RS-485 signal: D+, D-, GND
Relative humidity 10% to 95% RS-422 signal: T+, T-, GND, R+, R-
7. Installation: support 2 kinds of wall mounting installation Parity bit: None, Even, Odd, Space, Mark
Wiring Requirements Data bit; 5bit,6bit,7bit,8bit
Cable laying need to meet the following requirements, Stop bit: 1bit,1.5bit,2bit
1. It is needed to check whether the type, quantity and Band rate: 300bps~115200bps
specification of cable match the requirement before cable RS-232 Transfer distance: no more than 15m
laying; RS-232 connector: RJ45
2. It is needed to check the cable is damaged or not, factory RS-485 transfer distance: 1200m
records and quality assurance booklet before cable laying; RS-485 connector: 10 bits terminal block
3. The required cable specification, quantity, direction and Protection: class 3 static, RS-485/422 side, 1.5KV isolation
laying position need to match construction requirements, and LED Indicator
cable length depends on actual position; Working statue indicator: RUN
4. All the cable cannot have break-down and terminal in the Power (PWR)
middle; Ethernet port connection statue (Link)
5. Cables should be straight in the hallways and turning; Serial port transmit data indicator: TX1~TX8
6. Cable should be straight in the groove, and cannot beyond Serial port receive data indicator: RX1~RX8
the groove in case of holding back the inlet and outlet holes. Power requirements
Cables should be banded and fixed when they are out of the  NP308T-8DI(RS-485)
groove; Input voltage: 5VDC
7. User cable should be separated from the power lines. No-load consumption: 1.73W@5VDC
Full-load consumption: 2.31W@5VDC Free fall: IEC 60068-2-32
 NP308T-8D(RS-232) Vibration: IEC 60068-2-6
Input voltage: 5VDC Warranty
No-load consumption: 0.825W@5VDC Warranty time: 5 years
Full-load consumption: 1.320W@5VDC Certificates
 NP308T-8DI(RS-485) -P(9/48VDC) CE, FCC, RoHS, UL508(pending)
Input voltage: 9-48VDC
No-load consumption: 1.812W@12VDC
Full-load consumption: 2.364W@12VDC
Mechanical
Shell: IP30 protection, metal shell
Installation: Wall mounting
Size (L×W×H): 160mm×95.5mm×28mm
 NP308T-8DI(RS-485)
Weight: 486g
 NP308T-8D(RS-232)
Weight: 524g
 NP308T-8DI(RS-485) -P(9/48VDC)
Weight: 486g
Environment limits
Working temperature: -40~85℃
Storage temperature: -40~85℃

Relative humidity: 5%~95%(non-condensing)

Standard
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 55024,
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8,
EN 61000-4-11
Shock: IEC 60068-2-27