0% found this document useful (0 votes)
56 views3 pages

Arc Flash Suit 40 CAL-Catalog - Final

The document describes the Arc Defence™ by Hicare lightweight Arc Flash Protection suit, designed to protect electrical workers from hazards associated with arc flashes. It details the suit's material composition, design features, and applications in various electrical maintenance environments. The suit complies with multiple safety standards and includes a jacket, trousers, helmet, gloves, and storage bag.

Uploaded by

Kishore K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views3 pages

Arc Flash Suit 40 CAL-Catalog - Final

The document describes the Arc Defence™ by Hicare lightweight Arc Flash Protection suit, designed to protect electrical workers from hazards associated with arc flashes. It details the suit's material composition, design features, and applications in various electrical maintenance environments. The suit complies with multiple safety standards and includes a jacket, trousers, helmet, gloves, and storage bag.

Uploaded by

Kishore K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Electrical Protection Workwear

ARC FLASH
SUIT
40 CAL

Arc Defence™ by Hicare light weight Arc Flash Protection, an arc flash occurs when the electrical current
flows outside its intended path, through an air gap, to another conductor. With this in mind,
you can see that an arc flash can occur anywhere that the electrical current has a chance to escape. Arc
flash suits are full-body protective garments required for electrical workers to protect them from the heat
and energy released during an arc flash.
Introducing advance light weight, breathable 40 Cal Arc flash suits are personal protective garments (PPE)
designed to protect individuals working with electrical panels. Be sure to use an arc flash suit When
working with electrical equipment or in high arc-risk environments, use only an arc flash suit
that meets these ratings.
This helps to give the user an extra second of protection in order to avoid a secondary explosion or flash
in the working area.
Material Composition
Multi-layer Inherent Arc Flash
Resistance Fabric 550 GSM.

Design
Garment made of Inherent Arc Flash
resistance fabric along with the zip
and velcro closure and covered with flap.

Trouser come with zipper and elastic,


for better comfort and flexibility.

Mandarin collar for


maximum neck protection.

Elasticized side waistband


for a better fit and comfort.
Sleeve cuffs have adjustable
straps with Velcro closure.

Class E Helmet with Visor tested to


ASTM F 2178-12 Cal rated.
Throughout the garment's manufacturing,
FR thread is employed.

Various designs and patterns are


available to meet your needs.

Features
Highly Durable – Provides ultimate
protection against an ARC Flash's
Hazard and flame.
Made from Arc Flash Resistance material.
Full Body Protection – (garment made
of IFR blend, hence reduce Arc injury)
Great comfort – breathable soft to
wear and fantastic to the touch.
The FR Properties will remain constant
till the last washing cycle.

Sewing with IFR thread.

Kit Content
Jacket and Trouser
Class E Helmet with Paulson Face Shield
Fabric Gloves
Storage Bag.
Applications

1 TRANSMISSION LINE MAINTENANCE


2 LT AND HT PANEL MAINTENANCE
3 ELECTRICIANS FOR WORKWEAR
4 SUBSTATION WORK
5 PLANT SHUT DOWNS AND
ENERGIZED EQUIPMENT REPAIR
6 POWER GENERATION UNIT

Tested/Certification

Arc Flash Clothing complies Electrocution, Arc


EN ISO 11612: 2015 Protective flash, and Arc blast
Clothing - Clothing for Heat injuries and fatalities.
and Flame Protection.
EN 11612 EN 1149

For FR fabrics, this testing In an electric arc exposure,


method is used to calculate standard practice is used
findings (Arc ratings). Arc ratings to evaluate the response
are a measure of the fabric's characteristics & design integrity
F1959/F thermal protection in an arc flash. 2621 of arc rated finished garments.

Flame-resistant and electric Standard test method


arc performance specifications for determining the arc rating
people who are exposed to flame and standard approval for eye
and electric arc flash must wear and face protection products.
1506 arc rated protective clothing. 2178

NFPA 70E, Standard for Electrical IEC 61482-1-1 – Live working


Safety in the Workplace, provide – Protective clothing against
the protection From electrocution, the thermal hazards of an
arc flash, and arc blast injuries electric arc.
and fatalities. IEC 61482-1-1

INHERENT ARC
HRC 2 PROTECTION
LI GHT WEI GHT

Hi-Care Safety Solutions Connect With Us


First Floor, Plot No R 798 Egala No 110, Phone: +91 84250 55552
Hasti Industrial Estate, Mahape, E-mail: [email protected]
Navi Mumbai - 400701, Thane, Maharashtra, India Web: www.hicaresafety.in