DN Series 200 FL CEN 177 753r04

The document provides installation guidelines for the DN Series™ 200 Front Load safes, detailing requirements for both US and Canadian markets, including ADA and CSA standards for accessibility. It outlines consumer access dimensions, conduit and junction box requirements, and power specifications for the cash dispenser. Additionally, it emphasizes the need for consultation with Diebold Nixdorf for installation and service details.

Uploaded by

atmrmg03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views7 pages

DN Series 200 FL CEN 177 753r04

The document provides installation guidelines for the DN Series™ 200 Front Load safes, detailing requirements for both US and Canadian markets, including ADA and CSA standards for accessibility. It outlines consumer access dimensions, conduit and junction box requirements, and power specifications for the cash dispenser. Additionally, it emphasizes the need for consultation with Diebold Nixdorf for installation and service details.

Uploaded by

atmrmg03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

DN SERIES™ 200 FRONT LOAD

L1321
CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES

CALL 1-800-999-3600

REFER TO INSTALLATION MANUAL # 01750310382.


CONSULT WITH DIEBOLD NIXDORF INSTALLATION/SERVICE
FOR ADDITIONAL DETAILS AND INFORMATION.
M ETRES
NCHES)

500 SAFE
11
(19 16")
LLI
NI
N MI
ONS I
ONS I
M ENSI
M ENSI

FOR DN SERIES™ 200 AUTOMATED BANKING MACHINE (ABM) INSTALLATIONS IN THE US


MARKET (OR OTHER AREAS WHERE ADA STANDARDS ARE RECOGNIZED), INSTALLATION
DI

PRACTICES SHOULD BE GUIDED BY THE REQUIREMENTS LISTED IN THE 2010 ADA


(
DI

USA
4034"

STANDARDS FOR ACCESSIBLE DESIGN INCLUDING SECTION 707 WHICH DEFINES THE
1035

REQUIREMENTS FOR THE ACCESSIBILITY AND USABILITY OF AUTOMATIC TELLER


(

MACHINES (ATM) BY PERSONS WITH DISABILITIES OR THE LATEST VERSIONS /


REVISIONS OF THESE STANDARDS AVAILABLE AT THE TIME OF INSTALLATION.

FOR DN SERIES™ 200 AUTOMATED BANKING MACHINE (ABM) INSTALLATIONS IN THE


CANADIAN MARKET (OR OTHER AREAS WHERE CSA STANDARDS ARE RECOGNIZED),
INSTALLATION PRACTICES SHOULD BE GUIDED BY THE REQUIREMENTS LISTED IN

CANADA CAN/CSA-B651-04 AND CAN/CSA B651-18 NATIONAL STANDARD OF CANADA ACCESSIBLE


DESIGN FOR THE BUILT ENVIRONMENT AS WELL AS CAN/CSA-B651.1-09 ACCESSIBLE
DESIGN FOR AUTOMATED BANKING MACHINES OR THE LATEST VERSIONS / REVISIONS
RD ANGLE

OF THESE STANDARDS AVAILABLE AT THE TIME OF INSTALLATION.


ON

450
PROJECTI

(1734")
THI

496

(1912")
WHEN OPTIONAL ILLUMINATED
PRIVACY PANELS ARE INSTALLED OUTLINE OF OPTIONAL
ILLUMINATED PRIVACY PANELS

PLAN VIEW
1035
496 (4034")
(1912")

653
450
(251116")
PAGE 1 OF 7

(171116")
)
8378"
2130

(
)

)
56 8"

5618"
1445

1425
7
CE"

(
A

(
TERI
THOUT NOTI
GN CRI

690 SAFE
)
27316"
ONS AND DESI
SUBJECT TO CHANGE W I

(
M ENSI
ALL DI
"

500 SAFE 892 SAFE


11 1
(19 16") 67 (35 8") 58

(258") (2516")
1017

(40116")
FRONT VIEW
753 REV.4

19" LANDSCAPE DISPLAY SHOWN 1035


SEE PAGE 3 OF 7 FOR ADDITIONAL DISPLAYS (4034")

SIDE VIEW
LE NO.177-

NOTE
IN CASES WHERE AN INSTALLATION FRAME / PLINTH IS USED,
HEIGHT DIMENSIONS FROM FLOOR WILL NEED TO BE
INCREASED BY THE HEIGHT OF THE INSTALLATION FRAME USED.
SEE CUT SHEET 177-776 FOR INSTALLATION FRAME DETAILS.
FI
OPTIONAL UPS DETAILS FOR REAR or SIDE MOUNTING
DN SERIES™ 200 FRONT LOAD
L1321 CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES
450
11
(17 16")
1035
119
3
(40 4")
(41116")

653 229 102

)
2 2"
63
(251116") (9") (4")

1
(
M ETRES
NCHES)

AIR VENTS

)
LLI

16"
NI

99
15
N MI

3
ONS I

(
ONS I
M ENSI

10
M ENSI

3
( 8")

)
)

56 8"
5618"

1445
DI

1425

7
(
DI

(
(
REAR COVER CONCEALS

690 SAFE
690 SAFE
REAR MOUNTED UPS

)
)

16"
27316"

3
27
(
(
RD ANGLE
ON
PROJECTI

892 SAFE 500 SAFE


(3518") (191116")
THI

1027

(40716")
REAR VIEW
1045

(4118")

SIDE VIEW
OPTIONAL UPS REAR MOUNTED
PAGE 2 OF 7

450
1035
(171116")
(4034")
CE"
A
TERI

)
)
THOUT NOTI

5678"
5618"

1445
1425
GN CRI

(
(
ONS AND DESI
SUBJECT TO CHANGE W I

UPS
690 SAFE

685 UPS

685 UPS
)
27316"

)
27"

27"
M ENSI

(
(

)
ALL DI

16"

16"
5

5
3

3
(

(
"

CABLE ENTRY OPENING


38 500 SAFE
STANDARD LENGTH POWER 374 UPS
CORD 2210mm (87") FROM (112") (191116")
(1434")
SIDE OF TERMINAL. 85
753 REV.4

455 400 UPS


(338")
60 (1778") (1534")

(2516") 892 SAFE


FRONT VIEW
(3518")
LE NO.177-

NOTE
SIDE VIEW IN CASES WHERE AN INSTALLATION FRAME / PLINTH IS USED,
HEIGHT DIMENSIONS FROM FLOOR WILL NEED TO BE
INCREASED BY THE HEIGHT OF THE INSTALLATION FRAME USED.

OPTIONAL UPS SIDE MOUNTED SEE CUT SHEET 177-776 FOR INSTALLATION FRAME DETAILS.
FI
CONSUMER ACCESS DIMENSIONS
DN SERIES™ 200 FRONT LOAD
L1321 CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES

CONSUMER ACCESS DIMENSIONS


HEIGHT DEPTH

746mm 67mm
A KEYPAD (CENTER KEY 5 PIP)
(2938") (258")
M ETRES
NCHES)

772mm 149mm
B1 CASH IN/OUT
(3038") (578")
LLI

936mm 183mm
C CARD READER
NI

(361316") (7316")
N MI
ONS I

951mm 165mm
D RECEIPT PRINTER
ONS I

(3738") (612")
M ENSI

} (STD) LOW SOFTKEY


1057mm 201mm
M ENSI

(4158") (71516")
DI

1024mm 190mm
E1 (DDC) LOW SOFTKEY
(

(40516") (712")
DI

E3 (NDC) LOW SOFTKEY


1013mm 186mm
(3978") (7516")
E2

E4 C
} (STD) TOP SOFTKEY
1154mm
(45716")

1122mm
232mm
(918")

222mm
E2 (DDC) TOP SOFTKEY
(44316") (834")
E1
J
1135mm 226mm
(NDC) TOP SOFTKEY
D (441116") (8
15
16")
B1
RD ANGLE
ON

A } TOP OF SCREEN 15"


1220mm 255mm
PROJECTI

F (48") (10")

I 1366mm 306mm
E3 TOP OF SCREEN 19" (PORTRAIT)
G
THI

(531316") (12116")
H
1292mm 278mm
TOP OF SCREEN 19" (LANDSCAPE)
(5078") (101516")

} CENTER OF SCREEN 15"


1111mm
(4334")

1184mm
220mm
(834")

243mm
E4 CENTER OF SCREEN 19" (PORTRAIT)
(4658") (9916")

1147mm 234mm
CENTER OF SCREEN 19" (LANDSCAPE)
(45316") (914")

FRONT VIEW F CONTACTLESS CARD READER


743mm 61mm
(29516") (238")

15" WITH SOFTKEYS


PAGE 3 OF 7

711mm 2mm
G HEADPHONE JACK
(28") (0")

710mm 5mm
*
HEIGHT DIMENSIONS ARE FROM BOTTOM OF SAFE. IN CASES
WHERE AN INSTALLATION FRAME / PLINTH IS USED, HEIGHT
H BAR CODE READER
(28") 1
( 8")

DIMENSIONS FROM FLOOR WILL NEED TO BE INCREASED BY 739mm 54mm


THE HEIGHT OF THE INSTALLATION FRAME USED. I FINGERPRINT READER
(29") (218")
SEE CUT SHEET 177-776 FOR INSTALLATION FRAME DETAILS.
924mm 184mm
J CHECK DEPOSIT
(3638") (7316")

* HEIGHT - FROM BOTTOM OF SAFE


DEPTH - FROM FRONT EDGE OF BEZEL
CE"
A
TERI

E3
THOUT NOTI

E3
GN CRI

E4
E4
ONS AND DESI

C C
SUBJECT TO CHANGE W I

D
D
J J
A
A
M ENSI

B1 I B1
I
ALL DI

F H F
H
"

G G
753 REV.4
LE NO.177-

FRONT VIEW FRONT VIEW


19" LANDSCAPE 19" PORTRAIT
FI
CONDUIT AND JUNCTION BOX REQUIREMENTS POWER REQUIREMENTS
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
1 BOX TO 102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX
L1321 (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
(ALL BY OWNER'S E.C.(ELECTRICAL CONTRACTOR)).
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS

3
SPECIFIED BELOW.
OWNER'S E.C. TO RUN 19mm (4") LIQUID TIGHT FLEX METAL CONDUIT OR
CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
2 3
19mm ( 4") RIGID CONDUIT FROM JUNCTION BOX TO CABLE OPENING IN SAFE.
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE

3
100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
102mm (4") SQ. X 54mm (218") DEEP JUNCTION BOX WITH RECEPTACLE
3 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. (ALL BY OWNER'S E.C.)
POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED BY A
(SEE POWER REQUIREMENTS).
SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER
AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
M ETRES

OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY


NCHES)

BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
4 SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD
LENGTH 2210mm (87") FROM CABLE OPENING IN SAFE. 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES
200-240 VAC (±10%) SERVICE, DISCONNECT AT 10 AMPERES
NOTE
LLI

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
NI

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CABLE OPENING IN SAFE. POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
N MI
ONS I

(LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
ACCESSIBLE AREA.
ONS I

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR
POWER USAGE
M ENSI

BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. TERMINAL MAX. USAGE
MACHINE STATUS CONFIGURED WITH BATTERY
M ENSI

PHYSICAL SECURITY AS NOTED CHARGING


THE SAFE DOOR FEATURES A POSITIVE RELOCKING DEVICE. ACCESS TO THE SAFE BELOW (+130 WATTS)
DI

DOOR IS MANAGED BY AN INSTALLED MECHANICAL OR ELECTRONIC COMBINATION LOCK


(

IDLE (NO TRANSACTION) 120 WATTS 250 WATTS


DI

OR LOCKS THAT ARE UL CERTIFIED, VDS CERTIFIED CLASS 1 OR CLASS 2, AND/OR


EN-1300 CERTIFIED CLASS A OR CLASS B DEPENDING ON THE SYSTEM CONFIGURATION.
CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. OPERATION (MAXIMUM) 330 WATTS 460 WATTS

ALARM PROTECTION
CEN RATED SAFES EQUIPPED WITH A SAFE DOOR SWITCH BY DEFAULT. ADDITIONAL TERMINAL CONFIGURATION
ALARM AND SENSOR PACKAGES ARE AVAILABLE TO MONITOR FOR VARIOUS ATTACK DIP CARD READER, RECEIPT PRINTER WITH RETRACT, CASH IN/OUT RM4V, 15”SUNLIGHT
VECTORS. CONSULT THE SYSTEM OPERATING GUIDE FOR FURTHER INFORMATION. VIEWABLE DISPLAY, HIGH PERFORMANCE PC, CONTACTLESS CARD READER, BATTERY
INSTALLED AND CHECK DEPOSIT.

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN
SIGNAL CABLE RUN CONSTRAINTS THE TERMINAL, AND THE TYPE OF TRANSACTION THE TERMINAL IS PERFORMING.
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL
VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
RD ANGLE
ON

HEAT OUTPUT CONFIGURATION


PROJECTI

SEPARATION FROM OTHER CABLES 470 AVERAGE BTU/HR - USING 99kWh PER MONTH AS TYPICAL POWER CONSUMPTION.
HEAT OUTPUT VALUE IS BASED ON APPROXIMATELY 240 TRANSACTIONS PER DAY AND
TYPE OF ELECTRICAL RUN BELOW 2 KVA 2-5 KVA ABOVE 5 KVA ASSUMES NO ADDITIONAL POWER CONSUMPTION OR HEAT CONTRIBUTION FROM
THI

FLUORESCENT, NEON OR INCANDESCENT HEATERS IN COLD ENVIRONMENTS.


127mm (5") 127mm (5") 127mm (5")
LIGHTING FIXTURES
THE HEAT OUTPUT VALUES ABOVE ARE BASED ON MEASURED
UNSHIELDED POWER LINE OR AVERAGES FOR THE CONFIGURATION LISTED.
127mm (5") 305mm (1'-0") 610mm (2'-0")
ELECTRICAL EQUIPMENT
CLIMATIC ENVIRONMENTAL CONDITIONS
UNSHIELDED POWER LINES OR
ELECTRICAL EQUIPMENT WITH STATUS AIR TEMPERATURE RELATIVE AIR HUMIDITY
64mm (212") 152mm (6") 305mm (1'-0")
SIGNAL CABLES ENCLOSED IN
GROUNDED CONDUIT 0°C to 40°C
OPERATION INSIDE 5 to 85%
(32°F to 104°F)
POWER LINES IN GROUNDED CONDUIT
WITH SIGNAL CABLES IN GROUNDED 30mm (1316") 76mm (3") 152mm (6") 15 to 98%
TRANSPORT -25°C to 60°C (-13°F to 140°F)
CONDUIT

STORAGE -10°C to 40°C (14°F to 104°F) 5 to 98%


SIGNAL CABLE INSTALLATION CONSTRAINTS
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS. UNLIKE
WEIGHT OF UNIT
POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT
PAGE 4 OF 7

CEN I ---------------- 575 kg (1,268 LBS.) ACTUAL WEIGHT OF THE TERMINAL WILL
INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.
CEN III-------------- 665 kg (1,467 LBS.) DEPEND ON THE CONFIGURATION OF THE
450 CEN IV--------------- 674 kg (1486 LBS.) TERMINAL COMPONENTS AND OPTIONS
(171116") CEN III EXGas----- 669 kg (1,475 LBS.)
CEN IV EXGas----- 679 kg (1497 LBS.)
119

(41116")
1035
229 102
)
212"

(4034")
63

(9") (4")
(

AIR VENTS
)
31516"
99

(
CE"
A
TERI
THOUT NOTI

1
GN CRI
ONS AND DESI

1
)
5678"

56 8"
1445
SUBJECT TO CHANGE W I

1425
1
(

3
M ENSI

690 SAFE

690 SAFE
)

)
27316"

27316"
ALL DI

4
"

38
CABLE ENTRY OPENING
753 REV.4

STANDARD LENGTH POWER CORD


500 (112")
2210mm (87") FROM SIDE OF TERMINAL. 454 400
(191116")
(1778") (1534")
58

REAR VIEW (2516") 892 SAFE


LE NO.177-

SEE PAGE 2 OF 7 FOR DETAIL OF (3518")


TERMINAL WITH REAR MOUNTED UPS NOTE
IN CASES WHERE AN INSTALLATION FRAME / PLINTH IS USED, SIDE VIEW
HEIGHT DIMENSIONS FROM FLOOR WILL NEED TO BE SEE PAGE 2 OF 7 FOR DETAIL OF
INCREASED BY THE HEIGHT OF THE INSTALLATION FRAME USED. TERMINAL WITH SIDE MOUNTED UPS
FI

SEE CUT SHEET 177-776 FOR INSTALLATION FRAME DETAILS.


REQUIRED MINIMUM SERVICE AREAS
DN SERIES™ 200 FRONT LOAD
L1321 CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES

600

OUTLINE OF SPACE REQUIRED 50 (2358")


50
FOR TERMINALS WITH SIDE 15
(1 16") 500 SAFE (11516")
MOUNTED UPS
(191116")
M ETRES

)
11516"
NCHES)

OUTLINE OF SPACE REQUIRED

50
FOR TERMINALS WITH REAR

(
MOUNTED UPS
LLI
NI

)
250

33716"
N MI

)
3938"

850
ONS I

1000
(978")

)
40 4"
1035
ONS I

(
3
(
M ENSI

)
171116"
M ENSI

450
450 450
DI

(171116") (17
11
16")

(
(
DI

450

)
3938"
(1734")

1000
)
35716"

)
900

32 16"
815

(
1
(

(
RD ANGLE
ON
PROJECTI
THI

500 500 500


11 11 11
(19 16") (19 16") (19 16")

1500

(59116") REQUIRED MINIMUM SERVICE AREA

PLAN
PAGE 5 OF 7

1900

(741316")

50

(11516")
1209 641
(47916") (2514")
)
11516"
50

(
CE"
A
TERI
THOUT NOTI
GN CRI
ONS AND DESI

)
2235

88"
SUBJECT TO CHANGE W I

(
M ENSI

)
5618"
ALL DI

1425

(
"
753 REV.4
LE NO.177-

815 1035

(32116") (4034")
50

(11516")

SIDE VIEW
FI
THROUGH THE WALL EXTENDED TRIM
DN SERIES™ 200 FRONT LOAD
L1321
CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES

600 OUTLINE OF SPACE REQUIRED


FOR TERMINALS WITH UPS 670
(2358")
(2638")

M UM W ALL
CKNESS
THROUGH THE WALL
M ETRES

EXTENDED TRIM
NCHES)

M AXI
) THI
5 5
)

OPTIONAL
25"
634
LLI

3 3

41116"
( 16") ( 16") ILLUMINATED

120
NI

(
N MI

PRIVACY PANELS
ONS I

(
ONS I
M ENSI
M ENSI

)
10716"
265
)
1438"
DI

365

1505
(

(
(5914")
DI

)
491316"
670 WALL TRIM

1265
(2638")

)
3938"

(
1000
)
35716"
900

(
455 590 W.O. 455
(

15 1 15
(17 16") (23 4") (17 16")
RD ANGLE
ON
PROJECTI

374
THI

(141116")

374mm (141116") TO FRONT EDGE OF SAFE


1500
(SHOWN). 371mm (14316") TO FRONT EDGE OF
(59116")
INSTALLATION FRAME / PLINTH (NOT SHOWN)

PLAN
PERSPECTIVE
REQUIRED MINIMUM SERVICE AREA

NOTE
IN CASES WHERE AN INSTALLATION FRAME / PLINTH IS USED,
PAGE 6 OF 7

HEIGHT DIMENSIONS FROM FLOOR WILL NEED TO BE


INCREASED BY THE HEIGHT OF THE INSTALLATION FRAME USED.
SEE CUT SHEET 177-776 FOR INSTALLATION FRAME DETAILS.

590 W.O.

(23316")
CE"
A
TERI

NG
NG
THOUT NOTI

1480 W ALL OPENI


1480 W ALL OPENI

1505 W ALL TRI


GN CRI

)
)

5914"

5814"
5814"
ONS AND DESI
SUBJECT TO CHANGE W I

(
(
M ENSI
ALL DI
"

374mm (141116") TO FRONT EDGE OF SAFE (SHOWN)


374
753 REV.4

371mm (14316") TO FRONT EDGE OF INSTALLATION FRAME / PLINTH (NOT SHOWN)


(141116") 120
MAXIMUM WALL THICKNESS
(41116")
EXTERIOR ELEVATION
892 SAFE
LE NO.177-

(3518")

SECTION
FI
SAFE ANCHOR LOCATIONS AND DETAILS
DN SERIES™ 200 FRONT LOAD
L1321 CEN I, CEN III, CEN IV, CEN III EXGAS and CEN IV EXGAS SAFES
500
11
(19 16")

83 334 83

(314") (13316") (314")


M ETRES
NCHES)
LLI
NI
N MI
ONS I
ONS I
M ENSI

1 1
M ENSI

)
112"
38
DI

(
(

2
DI

)
15" CABLE ENTRY
OPENING
380

)
1678"
428
(

(
)
1534"
400

1
)
61116"

)
170

41316"
1
RD ANGLE

122
ON

(
PROJECTI

(
THI

81 338 83

(3316") (13516") (314")

PLAN/SECTION SAFE FLOOR


1 - (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES
7
2 - (1) 22mm (8") DIA. TEAR OFF SENSOR HOLE (FLOOR HOLE DRILL SIZE DETERMINED AT SITE)
NOTES
TO COMPLY WITH THE EUROPEAN STANDARD EN 1143-1 REGULATIONS, ANCHORING A CEN SAFE TO A WOOD FLOOR
IS NOT PERMITTED. DIEBOLD NIXDORF M20 ANCHOR BOLTS (OR EQUIVALENT) MEET/EXCEED THE FOLLOWING
RESISTANCE GRADE REQUIREMENTS WHEN PROPERLY INSTALLED:
PAGE 7 OF 7

CEN I, II & III: 50 kN (PULLOUT FORCE)


CEN IV: 100 kN (PULLOUT FORCE)

ANCHORING CEN SAFE TO CONCRETE FLOORS


DIEBOLD NIXDORF RECOMMENDS (4) M20 ANCHOR BOLTS THAT ARE 170mm (61116”) LONG FOR PROPERLY SECURING THE
UNIT (PART #01750308241). THE OVERALL DRILLING DEPTH DEPENDS ON STRUCTURAL CONDITIONS. THE MOUNTING ANCHORS
MUST BE LOCATED AT LEAST 125mm (41516”) DEEP IN THE LOAD BEARING CONCRETE (SEE DETAIL). ANCHOR BOLTS MUST BE
USED IN ALL (4) AVAILABLE ANCHOR HOLES. IF MOUNTING KIT IS NOT PROVIDED, USE EQUIVALENT FASTENING MATERIAL.
)
1116"-1716"

OPTIONAL
27-37

FLOOR
(4) SAFE FLOOR MOUNTING SETS TEAR-OFF
FINISH
SENSOR
(
CE"
A
TERI
THOUT NOTI
GN CRI

M UM
41516"
M UM
ONS AND DESI

125

CEN SAFE FLOOR


1916"
SUBJECT TO CHANGE W I

NI
40

NI

MI
(
MI
(
M ENSI
ALL DI

SECTION THROUGH SAFE FLOOR


"

FOR ILLUSTRATION ONLY - NOT TO SCALE

ANCHORING SAFE TO STEEL FLOORS


SYSTEMS INSTALLED ON A STEEL FLOOR CAN ALSO BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD.
DIEBOLD NIXDORF RECOMMENDS THE HARDWARE BE ATTACHED THROUGH SUPPORTING STEEL POST OR BEAMS FOR
753 REV.4

MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT
PLATE INSTALLED BELOW THE FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE STEEL BACKING PLATE THICKNESS MUST
(2”). MACHINE-THREADED NUT AND BOLT MUST BE USED IN ALL (4) AVAILABLE ANCHOR HOLES.
BE A MINIMUM OF 13mm 1

ANCHORING SAFE USING AN INSTALLATION FRAME / PLINTH


LE NO.177-

THE INSTALLATION FRAME MUST BE SECURED TO THE FLOOR USING (4) SUPPLIED THREADED RODS AT FOUR ANCHORING
POINTS (SEE CUT SHEET #177-776 FOR INSTALLATION FRAME DETAILS). THE SYSTEM CEN SAFE IS SECURED TO THE INSTALLATION
FRAME USING (4) M16 X 45mm (1.77”) PAN HEAD SCREWS AND WASHERS (PART #01750308237). IF MOUNTING KIT IS NOT PROVIDED,
USE EQUIVALENT FASTENING MATERIAL.