The YORK High Wall Inverter R-410A offers a range of cooling capacities from 3.5kW to 6.7kW, featuring a modern design, efficient cooling, and options for WiFi control. It includes advanced features such as a DC inverter compressor for better performance, turbo mode for quick cooling, and a 24-hour timer for convenience. The units are designed for quiet operation and easy maintenance, making them suitable for both home and office environments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views4 pages

Nuevo YORK Mini Split Inverter Setiembre 2023 AUX Modelos YHJE..YJMGXBOX - YHJE..XJMGXBRX

The YORK High Wall Inverter R-410A offers a range of cooling capacities from 3.5kW to 6.7kW, featuring a modern design, efficient cooling, and options for WiFi control. It includes advanced features such as a DC inverter compressor for better performance, turbo mode for quick cooling, and a 24-hour timer for convenience. The units are designed for quiet operation and easy maintenance, making them suitable for both home and office environments.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

HIGH WALL INVERTER R-410A 60HZ COOLING ONLY

YHJE 12 to 24 ZJMGXBORX
A complete range from 3.5kW to 6.7kW
HIGH WALL INVERTER R-410A 60HZ COOLING ONLY

Indoor Unit
• Modern, compact design
• Efficient cooling
• Hidden display
• 3D Air Flow
• Golden Fin
• WIFI (Option)

Remote Control
• 4 operation modes
• Sleep mode and on/off timers
• Turbo cool settings

Condensing Unit
• Fashion appearance
• Convenient installation
• Easy maintenance
• Golden Fin

The YORK ® line of High Wall Air Conditioners includes a wide range of sizes
to give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing and indoor units are engineered for quiet
operation. And comfort control settings are easily changed with the touch of a
button on the remote control.

2
HIGH WALL INVERTER R-410A 60HZ COOLING ONLY

Features and Benefits

DC Inverter Compressor R-410A


DC inverter compressor provides more comfortable Environmentally-friendly refrigerant cools and heats
indoor environment, higher performance in partial more efficiently without destroying the ozone layer.
INVERTER
load and better heating performance in low
ambient temperature than fixed compressor.

Turbo Mode 24-Hour Timer


Provides quicker cooling with one press of the Allows programmed start times up to 24 hours
remote button. in advance for flexible and more convenient
operation.

Multi-Speed Fan Self Diagnosis


Multi-speed fan helps satisfy various airflow Clearly displayed failure codes allow for quicker
requirements. troubleshooting and easier maintenance.

3-Minute Protection WIFI Control (Option)


A 3-minute delay before the compressor will Controls air conditioner with Smart phone or
restart helps avoid compressor damage and tablet through Internet.
work time.

Inner Groove Copper Tube


Inner groove copper tubing allows more refrigerant to pass
through, improving heat exchange by 30 to 50% when compared to
traditional copper tubing, and lowering power consumption while
keeping output capacity at the same level.

3
Specification

YORK Set Model YHJE12ZJMGXBORX YHJE18ZJMGXBORX YHJE24ZJMGXBORX


YORK Outdoor Model YHJE12YJMGXBO-X YHJE18YJMGXBO-X YHJE24YJMGXBO-X
YORK Indoor Model YHJE12XJMGXB-RX YHJE18XJMGXB-RX YHJE24XJMGXB-RX
Power supply V/Ph/Hz 208~230V/1Ph/60Hz 208~230V/1Ph/60Hz 208~230V/1Ph/60Hz
Power supply in Outdoor Outdoor Outdoor
Capacity(Min~Max) Btu/h 11,942(2,730-13,989) 18,000(4,436-19,107) 23,000(6,142-23,679)
Power Input(Min~Max) W 1,250(100-1,550) 1,700(500-1,800) 2,360(400-2,650)
Cooling
Current Rated(Min~Max) A 5.8(0.7-8.5) 7.2(2.3-8.0) 10.0(2.0-12.0)
SEER Btu/h·W 17 18 17
Moisture Removal l/h 1.0 1.6 3.0
Max. input consumption W 1,550 1,900 2,650
Max. current A 8.5 11.0 12.0
Power Input W 37 60 70
Indoor fan motor Capacitor μF 2 3 NA (DC Inverter)
Speed (H/M/L) rpm 1,280/1,130/850 1,230/1,080/850 1,330/1,180/850
Indoor air flow (H/M/L) m3/h 490/430/370 700/625/550 1,200/1,100/950
Indoor noise level (H/M/L) dB(A) 36.7/32.8/29.2 39.9/36.7/33.1 47.4/44.5/41.1
Unit (WxHxD) mm 750×200×285 900×225×310 1,082×233×330
Indoor dimension
Packing (WxHxD) mm 800×265×345 970×302×382 1,155×312×397
Indoor weight Net/Gross kg 8.0/9.5 12.0/13.5 13.0/15.5
Type Rotary Rotary Rotary
Power Input W 805 1,100 1,070
Compressor
Rated current(RLA) A 2.52 6.75 3.63
Refrigerant oil / Charge ml ESTER OIL VG74 / 300 ESTER OIL VG74 / 420 FWS50 / 350
Power Input W 48 89 87
Outdoor fan
Capacitor μF NA (DC Inverter) NA (DC Inverter) NA (DC Inverter)
motor
Speed (H/M/L) rpm 920/700/540 850/700/500 900/800/500
Outdoor air flow (H/M/L) m3/h 2,100/1,650/1,200 2,600/2,150/1,650 2,750/2,300/1,800
Outdoor noise level (H/M/L) dB(A) 50.7/50.3/50.1 55.3/54.5/53.9 59.0/59.0/58.8
Outdoor Unit (WxHxD) mm 705×530×279 785×555×300 825×655×310
dimension Packing (WxHxD) mm 825×595×345 888×590×367 945×725×435
Outdoor weight Net/Gross kg 21.5/24.5 27.0/30.0 37.0/40.0
Type R-410A R-410A R-410A
Refrigerant
Charge g 520 1,000 1,020
Liquid side Ø mm 6 6 6
Gas side Ø mm 9 12 15.88
Max. refrigerant pipe length m 15 15 15
Refrigerant pipe
Max. difference in level m 10 10 10
Standard connection pipe length m 5 5 5
Add refrigerant quantity per meter g 20x(Length-5) 30x(Length-5) 30x(Length-5)
Controller setting temperature range °C 16-32 16-32 16-32
Ambient temperature range °C 0~43 0~43 0~43
Qty’per 20’& 40’&40HQ Set 119/246/282 90/186/211 65/138/156

Nominal testing conditions:


Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2023 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide PUBL-5354(0123)