0% found this document useful (0 votes)
84 views12 pages

Sargent Pe80 Series Al Alarmed Exit Devices Installation Instructions

The document provides installation instructions for the SARGENT AL-PE80 Series Alarmed Exit Devices, emphasizing the need for trained personnel to perform the installation to avoid damage and warranty voiding. It details the device's features, including alarm activation upon exit and manual dogging, as well as necessary preparations and tools for installation. Additionally, it outlines optional settings for alarm functionality and low battery alerts.

Uploaded by

Xavier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views12 pages

Sargent Pe80 Series Al Alarmed Exit Devices Installation Instructions

The document provides installation instructions for the SARGENT AL-PE80 Series Alarmed Exit Devices, emphasizing the need for trained personnel to perform the installation to avoid damage and warranty voiding. It details the device's features, including alarm activation upon exit and manual dogging, as well as necessary preparations and tools for installation. Additionally, it outlines optional settings for alarm functionality and low battery alerts.

Uploaded by

Xavier
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Installation Instructions

AL-PE80 Series
Alarmed Exit Devices

WARNING WARNING
This product can expose you to Attention Installer: Improper
lead which is known to the state of installation may result in damage
California to cause cancer and birth to the product and void the factory
defects or other reproductive harm. warranty.
For more information go to www.
P65warnings.ca.gov.

1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents. A8325-1 05/23
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

1 General Description

The SARGENT Alarmed Exit is designed for areas that require an alarm to sound upon exiting. Once
armed, any push rail movement will activate the horn in the push rail. The horn will continue to sound for
two minutes and then shut off automatically. The LED will flash indicating a violation has occurred.

Manual dogging is provided standard on 1” diameter hole(s) required for routing wires
non fire rated devices. into the door when remote option(s) is used.

Notes:
• Installation must be performed by a trained service person.
• Basic installation is 9V alkaline battery operated. For hardwired option use 546 Wiring harness -
See instruction sheet included with kit.
• Field cut rail assemblies are not allowed. Exit device must be ordered from the factory for specific door width.

Tools Needed

1-800-727-5477 • www.sargentlock.com A8325-1 05/23


Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 2
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

2 Miscellaneous Parts
End Cap

Mounting Plate

Rail Assembly

Chassis

Chassis Cover

Alarm Insert Sub-Assembly

A8325-1 05/23
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 3
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

3 Door Preparation and Handing

Verify hand and bevel of door. Exit devices are always reverse bevel and are mounted on the
inside of the door.

Left Hand Right Hand


Reverse Bevel Reverse Bevel
Hinges Left. Hinges Right.
Open Outward Open Outward
LHRB RHRB

AL-PE8800 LHRB AL-PE8800 RHRB


shown shown

Outside View Inside View Outside View Inside View

4 Cylinder Installation or Replacement

Note: If the cylinder is factory installed, go to Step 5 Installation Instructions on page 6.

A B

Remove the battery and the battery box screws. Disconnect the wire harness.

1-800-727-5477 • www.sargentlock.com A8325-1 05/23


Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 4
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

4 Cylinder Installation or Replacement (continued)

Remove the original cylinder (or foam plug, if


c
C ordered without the cylinder):
Cylinder (or foam plug) a. Remove the battery box to expose the rear side
of the cylinder side. Use caution not to damage
any wire or switch when opening the battery
box as it is still connected to the assembly with
the battery terminal wires.
b. Remove the cylinder nut and switch actuator.
a
c. Remove the original cylinder (or foam plug).
Switch
Actuator

Cylinder
Nut

b
Battery
Box

a Install the new cylinder:


D a. Install the new cylinder to the insert sub-
Cylinder assembly with the keyway closest to the switch
end.
b. Reinstall the switch actuator with its legs on
opposite sides of the toggle switch on the
alarm board.
d
c. Reinstall the cylinder nut, then tighten.
b d. Replace the battery box.
Switch
Actuator

c
Cylinder
Nut

Battery
Box

A8325-1 05/23
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 5
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

4 Cylinder Installation or Replacement (continued)

E F

Connect the wire harness. Reinstall the battery box screws and the battery.

5 Installation Instructions (for retrofit kit)


Note: If an AL- prefix was ordered on a full device, refer to those instructions for the device installation.
The following instructions are for alarm setup.

A B
d Mount Rail

a c

Remove the existing rail: Insert


a. Remove chassis cover and end cap.
b. Loosen the chassis mounting screws.
c. Remove the end bracket. Remove the mount rail and standard insert from
d. Slide the rail assembly from the chassis. the push and carrier sub-assembly.

1-800-727-5477 • www.sargentlock.com A8325-1 05/23


Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 6
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

5 Installation Instructions (for retrofit kit, continued)

C
a. Insert the trigger mechanism arms to the gap
on both sides of the dogging cam (if present).
Dogging slope
a b. Slide the trigger mechanism forward into the
slot at the back of the dogging slope until it
clicks into place.
c. Press and release the push rail to verify that
the trigger is properly installed.

Push Rail
c

Trigger Mechanism
b

D E6
a
Mount Rail

d b

Alarm Insert
Sub-assembly

Slide the mount rail until it stops on the dogging Reinstall the rail:
slope, then install the alarm insert sub-assembly a. Slide the rail assembly to the chassis.
with the cylinder close to the push. Make sure b. Reinstall the end bracket.
to press the switch firmly against the trigger c. Tighten the chassis mounting screws.
mechanism. d. Reinstall the chassis cover and end cap.

A8325-1 05/23
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 7
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

6 Alarmed Exit (AL-) Standard Operating Instructions


To Arm Device Security / Tamper Violation

Yellow LED Green LED Red LED

Turn the key clockwise. The LED will flash yellow When ARMED, depressing the push rail will activate
(PASSAGE) for 15 seconds (default). A quick chirp the alarm. The alarm will sound and the LED will flash
will sound and the LED will flash green (ARMED) red (VIOLATION). The alarm will continue for
every 30 seconds. Signal indicates unit is armed. 2 minutes (default). After 2 minutes, the LED will
flash red every 30 seconds until rearmed using the
NOTE: The unit is automatically armed 15 seconds key. Turn the key counter clockwise to deactivate the
after the unit is turned on. Field selectable settings alarm, then clockwise to rearm.
listed on the next page.

Low Battery Alert

The alarm chirps intermittently to indicate low


battery. Change the battery.

Battery: 9V alkaline
1-800-727-5477 • www.sargentlock.com A8325-1 05/23
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 8
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

7 Optional Settings

These field selectable switches can change the following functions:

Request to Exit/
Auto Alarm Reset
Passage Time Delay
DS3 DS4 Timer Reset DS1 DS2 Timer Reset DS5
OFF OFF 2 minutes OFF OFF 7 seconds ON GREEN/ARMED
RED/VIOLATION
OFF ON 5 minutes OFF ON 10 seconds
YELLOW/ PASSAGE (DEFAULT)
ON OFF 10 minutes ON OFF 15 seconds OFF GREEN/VIOLATION
ON ON Continuous* ON ON 20 seconds RED/ARMED
YELLOW PASSAGE
Recommend 3267 power supply and 546 wiring harness.

DS6*
ON Monitor relay is enabled (will activate when rail is violated)
*Requires 546 wire harness. See optional 546 wiring instructions for more information.

A8325-1 05/23
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 9
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

1-800-727-5477 • www.sargentlock.com A8325-1 05/23


Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 10
AL-PE80 Series
Alarmed Exit Devices
Installation Instructions

A8325-1 05/23
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without
the express written permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent
www.assaabloydss.com/patents. 11
1-800-727-5477 • www.sargentlock.com

Copyright © 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents. A8325-1 5/23

You might also like