0% found this document useful (0 votes)
50 views2 pages

Solis Datasheet S6-EH3P (29,9-50) K-H Global V2,5 202409

The GINLONG TECHNOLOGIES S6-EH3P(29.9-50)K-H is a series of three-phase high voltage energy storage inverters designed for high-power PV modules, featuring overload capability, real-time battery monitoring, and peak shaving functionalities. It supports a wide range of battery voltages and offers various models with different power outputs, all while ensuring high efficiency and protection features. The inverters are equipped with advanced communication options and are suitable for diverse applications, including grid and backup power systems.

Uploaded by

Thant Zaw Win
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views2 pages

Solis Datasheet S6-EH3P (29,9-50) K-H Global V2,5 202409

The GINLONG TECHNOLOGIES S6-EH3P(29.9-50)K-H is a series of three-phase high voltage energy storage inverters designed for high-power PV modules, featuring overload capability, real-time battery monitoring, and peak shaving functionalities. It supports a wide range of battery voltages and offers various models with different power outputs, all while ensuring high efficiency and protection features. The inverters are equipped with advanced communication options and are suitable for diverse applications, including grid and backup power systems.

Uploaded by

Thant Zaw Win
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

GINLONG TECHNOLOGIES CO.,LTD.

S6-EH3P(29.9-50)K-H

Solis Three Phase High Voltage Energy Storage Inverters

Features:
• 2 seconds of 160% overload capability

• Supports a maximum input current of 20A, making it ideal for all high-power PV modules of any brand

• Real-time battery monitoring, remote upgrade, and battery healing function to prolong battery life

• Supports peak shaving features in "self-use" and "generator" modes

• Supports Unbalanced and Half-Wave Loads on both the Grid and Backup Port

• A wide battery voltage range accommodates the prevalent high-voltage lithium batteries found in the market

• Battery charging/discharging current 140A/70A+70A, suitable for 280Ah cell standard 0.5C application condition

• Supports 200% DC/AC ratio and makes full use of PV charging, providing a long backup
英语

NEW

Models:
S6-EH3P29.9K-H

S6-EH3P30K-H

S6-EH3P40K-H

S6-EH3P50K-H
www.solisinverters.com

DATASHEET S6-EH3P(29.9-50)K-H

Models 29.9K 30K 40K 50K


Input DC (PV side)
Recommended max. PV array size 59.8 kW 60 kW 80 kW 100 kW
Max. usable PV input power 59.8 kW 60 kW 80 kW 96 kW
Max. input voltage 1000 V
Rated voltage 600 V
Start-up voltage 180 V
MPPT voltage range 150 - 850 V
Max. input current 40 A / 40 A / 40 A 4 × 40 A
Max. short circuit current 60 A / 60 A / 60 A 4 × 60 A
MPPT number / Max. input strings number 3/6 4/8
Battery
Battery type Li-ion
Battery voltage range 150 - 800 V
Max. charge / discharge power 32.1 kW 33 kW 44 kW 55 kW
Max. charge / discharge current 70 A × 2 (1)
No. of battery inputs 2
Max. charge / discharge power of each input 32.1 kW 33 kW 35 kW 35 kW
Communication CAN / RS485
Output AC (Grid side)
Rated output power 29.9 kW 30 kW 40 kW 50 kW
Max. apparent output power 29.9 kVA 30 kVA 40 kVA 50 kVA
Rated grid voltage 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 45.4 A / 43.2 A 45.6 A / 43.3 A 60.8 A / 57.7 A 76 A / 72.2 A
Max. output current 45.4 A / 43.2 A 45.6 A / 43.3 A 60.8 A / 57.7 A 76 A / 72.2 A
Power factor > 0.99 (0.8 leading - 0.8 lagging)
THDi < 3%
Input AC (Grid side)
Max. AC passthrough current 90.8 A / 86.4 A 91.2 A / 86.6 A 121.6 A / 115.4 A 152 A / 144.4 A
Rated input voltage 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated input frequency 50 Hz / 60 Hz
Input Generator
Max. input power 29.9 kW 30 kW 40 kW 50 kW
Rated input current 45.4 A / 43.2 A 45.6 A / 43.3 A 60.8 A / 57.7 A 76 A / 72.2 A
Rated input voltage 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated input frequency 50 Hz / 60 Hz
Output AC (Back-up)
Rated output power 29.9 kW 30 kW 40 kW 50 kW
Max. apparent output power 1.6 times of rated power, 2 s
Back-up switch time < 10 ms
Rated output voltage 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
Rated frequency 50 Hz / 60 Hz
Rated output current 45.4 A / 43.2 A 45.6 A / 43.3 A 60.8 A / 57.7 A 76 A / 72.2 A
THDv (@linear load) < 2%
Efficiency
Max. efficiency 97.8%
EU efficiency 97.4%
BAT charged by PV max. efficiency 98.5%
BAT charged / discharged to AC max. efficiency 97.5%
Protection
Anti-islanding protection Yes
Output over current protection Yes
Short circuit protection Yes
Integrated DC switch Yes
DC reverse-polarity protection Yes
Surge protection DC Type II / AC Type II
Integrated AFCI 2.0 Optional
General Data
Dimensions (W × H × D) 530 × 880 × 290 mm
Weight 73 kg
Topology Transformerless
Self-consumption (night) < 35 W
Operating ambient temperature range -25 ~ +60°C
Relative humidity 0 - 95%
Ingress protection IP66
Cooling concept Intelligent fan-cooling
Max. operation altitude 4000 m
G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126/UTE C 15/VFR:2019,
Grid connection standard NTS 631/RD 1699/RD 244/UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2,
IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022
Safety / EMC standard IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
Features
PV connection MC4 Quick connection plug
Battery connection Terminal connector
AC connection Terminal Block
Display 7.0" LCD display & Bluetooth + APP
Communication CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN
(1) Supporting parallel 140A input.