PCXDSID2301
The Next-Generation Refrigerant
Inverter SkyAir Series
There’s more to
feel good about
1
2
Ozone layer Economic
protection feasibility
1. R32 does not deplete the ozone 1. R32 refrigerant is now available in
layer unlike R22. high volume globally since it is 50%
2. It is 1/3 lower in global warming of R410A composition.
potential comparing with R410A. 2. R32 has 9 % lower liquid density
compared to R410A. In a same
system, R32 charge is lesser than
R410A.
0 Ozone Depletion Potential
675 Global Warming Potential
0 Ozone Depletion Potential
R410A 2,090 Global Warming Potential
0.05 Ozone Depletion Potential
R22 1,810 Global Warming Potential
3
This game changing refrigerant strikes the perfect
balance between energy efficiency, ease of use
and environmental sustainability; offering distinct
advantages across the board, bringing you comfort
and a peace of mind.
Energy
Safety LCCP efficiency
R32 refrigerant is a stable refrigerant. 1. Life Cycle Climate Performance 1. Several factors that contribute to
The amount of refrigerant charge (LCCP) is an indicator to evaluate better efficiency of R32 system are:
deposited into the unit is insufficient to the total global warming impact of • R32 refrigerant has lower vapour
cause ignition. refrigerants. density and lower system mass
2. Factors included in LCCP are flow rate. Thus, about 50% lower
emission during: pressure drop can be expected.
• refrigerant manufacturing. • R32 refrigerant has 43-50%
• air conditioner manufacturing. higher latent heat compared to
• air conditioner operating, R410A.
servicing, and disposal. • R32 refrigerant has 41% higher
3. LCCP of R32 refrigerant is the liquid thermal conductivity
lowest, which promotes itself as compared to R410A, which
a better substitution for future permits better heat transfer at the
refrigerant. same mass flux.
4
Product Line-up
Class 71 85
Floor Standing
Indoor Unit FVFC71AV14 FVFC85AV14
(Wireless Handset)
Condensing Unit
Outdoor Unit RC60AGV1V
RC50AGV1V
RZFC71AGV14 RC85AG1V /
RZFC85AV14
(Gold Fin / MCHE ) RC85AGY1V
Gold Fin MCHE
Power supply 200-240/1/50
220-240/1/50 (PID)
(PID)
200-240/1/50 (POD) 220-240/1/50 (POD)
Remark :
POD : Power from Outdoor
5
100 125 140
FVFC100AV14 FVFC125AV14 FVFC140AV14
RC100AGY1V
RZFC100AV14 RC125AGY1V
RZFC125AY14 RC140AGY1V
RZFC140AY14
MCHE MCHE MCHE
380-415/3/50 (POD)
220-240/1/50 (POD) 380-415/3/50 (POD)
380-415/3/50 (POD) 380-415/3/50 (POD)
380-415/3/50 (POD)
6
Energy Saving
R32 refrigerant properties provide better heat
transfer compared to R410A refrigerant.
Combining with higher efficiency of an
Inverter Technology, the efficiency is
tremendously improved by 33% from
previous R410A Non Inverter models for
better energy saving. Average CSPF
increases as shown.
33%
3.14 4.18
R410A NEW R32
Non Inverter Inverter
(average) RZFC-A Series
(average)
Floor Standing
High Air Flow
High air flow ensures the spaces of
the room to be cooled down rapidly
to the set temperature.
7
Auto-Swing Mode Timer Selector
This unit uses its automatic horizontal swing louver to spread Operation starts when the preset time of the ON timer elapses
comfortable air flow to cool every corner of the room. Its vertical and stops when the preset time of the OFF timer elapses.
louvers are adjusted manually to match different interior spaces
and partition as well as to avoid direct airflow.
Powerful/Turbo Operation
New powerful/turbo operation boosts airflow to maximum
volume for a 20-minute period with highest fan speed. After
this, the unit automatically returns to its previous settings.
Indoor Unit ON/OFF Switch
The unit can be conveniently started manually in the event the
wireless remote controller is misplaced or the wireless remote
controller batteries are not charged.
Manual setting of
Auto horizontal swing
vertical airflow louvers
User-Friendly Controls
The unit comes with a stylish black control panel with white LED
Easy Maintenance
light for clear display. It comes with a keylock function to prevent
setting change from unauthorised personnel.
Safety Clip
The safety clip feature allows the users to remove the washable
saranet filter with ease during maintenance. At the same time, it
also acts as a safety feature to prevent the users from reaching
OFF State ON State
White display lights up to into the electrical and mechanical components.
indicate modes and
temperature settings
when switched on
Keylock icon
displayed when
Keylock Function: Safety clip
Activation and
deactivation of keylock
by pressing “SWING”
and “TURBO” together
Additionally, this unit is incorporated with
infrared sensor for usage with wireless
controller (BRC52A62) which comes with Space for Water Drain Pump
the unit as the standard package. Thus, There is a space in the unit below the fan that allows users to
it can also be controlled using wireless install an external condensate water pump.
controller for the flexibility in controls. * The condensate water drain pump is separately purchased
and field installed.
Two Selectable Temperature
Sensors
Both indoor unit and wired remote controller (option) contain
temperature-sensors. Temperature sensing can be set at the unit
or, to further improve comfort level, closer to the target area at the
wired remote control. This feature must be set during commis-
sioning by the technicians.
*Temperature-sensor on indoor unit must be used when the air
conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor
Switchable Fan Speed
High Medium Low
Piping Condensate
High setting provides maximum reach while low setting water
Floor Standing Unit drain pump
minimizes drafts.
8
Outdoor
RZFC71A RZFC85/100A RZFC125/140A
High Performance Inverter R32 Long Piping Length
Compressor Improved piping length to provide installation flexibility.
Swing compressor providing high efficiency during partial load
operation. Size 71 85 100 125 140
Max Piping
30 50 50 50 50
Length (m)
Max Piping
Anti-Corrosion Outdoor Heat Elevation (m)
15 30 30 30 30
Exchanger
The outdoor units come with anti-corrosion properties with it's
gold fin heat exchanger and new corrosion resistant aluminium
alloy microchannel heat exchanger.
Remark: Gold fins heat exchanger for RZFC71A and
microchannel heat exchanger for RZFC85-140A.
High Durability Imitating the
Outdoor Casing : Adopted zinc coated heavy gauge galvanized performance
of the
steel, with exterior surfaces finished with a weather resistant swan
polyester powder casing, painted with ivory white colour to
increase durability.
V-Cut Propeller Fan
Through the use of a V-cut propeller fan that imitates the
Refrigerant Cooling efficiency of the swan, a migratory bird, airflow becomes smooth
as friction loss is reduced. Therefore, performance increases
Daikin's unique refrigerant cooling system helps to protect the tremendously. Furthermore, it reduces the sound pressure level
printed circuit board and maintains high cooling capacity even as shown below.
during high outdoor temperatures.
Remark: For RZFC125/140A only.
Coated Printed Circuit Boards (PCB) Quiet Operation
Coated PCB prevent problems caused by humidity and airborne Sound Pressure
dust. It also protects against salt contained in sea breezes. Both 71 85 100 125 140
Level (dBA)
side of the PCB in outdoor units are coated.
R32 Inverter 52 53 54 54 56
R410A Non Inverter 58 N/A 58 60 65
9
Controllers
Wireless Controller
1
6
2
7
8 3
9
4
10 5
11
BRC52A62
1 “Glow-in-the-dark” 6 Auto-swing
ON/OFF switch 7 Selectable mode:
2 Fan speed selection: Cool, Dry, Fan
Low, Medium, High, Auto 8 Turbo function
3 Temperature setting: 9 Quiet function
Up & down 10 On timer setting
4 Sleep mode function 11 Real time clock
5 Off timer setting
Wired Controller (Optional Accessory)
1
6 2
7 3
8 4
9 5
1
BRC51D61
1 Temperature Setting 6 Features Selection (Sleep,
2 ON/OFF Button Quiet and Powerful)
3 Mode: Press to select 7 Fan Operation
operating mode: COOL, 8 Powerful Operation
DRY or FAN
9 Swing
4 Quiet Operation
5 Timer
Remark : Refer Function Overview for applicable model
Built-in Temperature Sensor in Wired Controllers
All wired controllers has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort. It can be
connected directly to the unit’s main board to start operating without extra settings or modifications. This feature can be set by installers
during the commissioning.
10
Product Features
Cooling Comfort Lifestyle Convenience
Powerful/Turbo Mode Sleep Mode
Once activated, this feature will engage the indoor fan Unwind at the end of the day with Sleep Mode, which
motor to run at maximum speed for 20 minutes. The gradually increases set temperature according to
powerful/turbo airflow enables the desired temperature regular sleeping temperature patterns for an
to be achieved faster, especially in larger spaces. effortlessly personalised sleeping environment.
Timer
This timer can start or stop the air conditioner within a
24-hour period and can be preset in 30 minute steps
using the wireless remote controller. The On Timer
Reliability and Off Timer can be used in combination.
Flexible Piping
Designed for your convenience, this series come with
piping lengths up to 30m & 50m, for high flexibility in
system design and installation.
Auto-Restart with Surge Protection Cleaner Environment
If there is a sudden power failure, the unit will
automatically restart with 64 different recovery patterns
according to its last settings. This also prevents a Clean Air
sudden surge of electricity to your power source. The Saranet Air Filter fiber traps airborne dust particles
in the air. The filters can be easily accessed or
replaced via the detachable front panel.
Serviceability Friendly
Self-Diagnosis Function
This intelligent feature helps to detect faults of
malfunctioning in the system.
Warning can be found through display error code in
wired LCD remote controller. This information can be
found in Installation Manual.
Centralized Control
iTM Intelligent Touch Manager (iTM)
Connectivity (option)
Connectivity to a centralized control system is
available (requires optional adaptor).
11
Functions Overview
FVFC71A FVFC85/100/125/140A
Category Functions
RZFC71A RZFC85/100/125/140A
Inverter • •
Basic Function Operation Limit for Cooling (°CDB)(O/D) 21~46 21~46
Operation Limit for Cooling (°FDB)(O/D) 69.8~114.8 69.8~114.8
Scroll Compressor - -
Compressor Rotary Compressor - -
Swing Compressor • •
4-Way Airflow Operation - -
Comfortable Airflow 8-Way Airflow Operation - -
Surround Airflow Operation - -
Auto Fan Speed • •
Switchable Fan Speed • •
Comfort Control
Auto Swing (Left-right) • •
Indoor Unit Quiet Operation - -
Programme Dry Function • •
ECO+ - -
Operation Powerful/Turbo Mode • •
Sleep • •
Fan Only • •
Indoor Unit ON/OFF Button • •
Signal Receiving Sign*1 • •
2
R/C with Backlight * •* •*
Lifestyle Convenience
LED Display ON/OFF Button - -
2
Room Temperature Display * •* •*
Streamer ON/OFF Button *1 - -
Saranet Filter • •
Ionizer - -
Health & Clean
Fresh Air Intake Kit - -
Washable Grille • •
Weekly Timer Operation *2 •* •*
Timer 24-hour ON/OFF Timer (R/C) * 1 • •
24-Hour RTC - -
Auto Restart (After Power Failure) • •
Self-diagnosis • •
Worry Free Wiring Error Check Function • •
(Reliability & Durability) Anti-corrosion Treatment of Outdoor Heat Exchanger Gold Fin MCHE
Low/High Voltage Shield (PCB Level) • •
R32 Refrigerant Gas Sensor • •
ESP Selection - -
Water Pump (Water Drainage Pipe Flexibilty) •* •*
Flexibility
°F/°C Changeover R/C Temperature Display (Factory setting: °C) • •
Pre-charged Piping Length 10m 15m
Wireless LAN Connectivity - -
Remote Control BAG Connectivity - -
iTM Connectivity * 3 •* •*
Wireless BRC52A62 BRC52A62
Remote Controller
Wired (Optional) BRC51D61 BRC51D61
Notes:-
• : Available
- : Not Available
•* : Optional (Refer to DAMA Spare Part team for more details on optional items.)
*1: Applicable when wireless (BRC52A62) remote controller is used for selected models.
*2: Applicable when wired (BRC51D61) (SHIRO) is used.
*3: Additional adaptor KRP928BB2S is required to establish connectivity.
12
Specifications
R32 Inverter Floor Standing Specifications
Indoor unit FVFC71A FVFC85A FVFC100A FVFC125A FVFC140A
Model
Outdoor unit RZFC71A RZFC85A RZFC100A RZFC125A RZFC140A
Operating Limit C 21~ 46 21 ~ 46 21 ~ 46 21 ~ 46 21 ~ 46
Btu/h 24200 (10900-27300) 29000 (14300-31000) 34100 (17100-38200) 42700 (18200-46500) 46500 (18200-49000)
Cooling Capacity (Min-Max)
kW 7.10 (3.20-8.00) 8.50 (4.20-9.10) 10.00 (5.00-11.20) 12.50 (5.30-13.60) 13.60 (5.30-14.40)
EER W/W 3.05 3.01 3.01 2.77 2.70
CSPF Wh/Wh 4.27 4.20 4.10 4.25 4.10
Total Power Input W 2330 2820 3320 4520 5045
Total Current A 10.20 12.60 14.60 7.00 7.77
220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50
Power Supply V/Ph/Hz
Power from OUTDOOR Power from OUTDOOR Power from OUTDOOR Power from OUTDOOR Power from OUTDOOR
Airflow (H/M/L) cfm 675/625/530 1000/835/650 1090/975/860 1240/1144/1040 1240/1144/1040
Sound Pressure Level (H/M/L) dB(A) 44/42/39 47/44/41 49/47/44 53/51/49 53/51/49
Unit mm 1850 X 600 X 270 1850 X 600 X 350 1850 X 600 X 350 1850 X 600 X 350 1850 X 600 X 350
Unit Dimensions
Indoor
(HxWxD) Packaging mm 760 X 1998 X 418 760 x 1998 x 498 760 x 1998 x 498 760 x 1998 x 498 760 x 1998 x 498
Machine Weight Unit kg 42 45 45 45 48
Gross kg 54 58 58 58 61
Sound Pressure Level dB(A) 52 53 54 54 56
Unit mm 615 X 845 x 300 695 X 930 X 350 695 X 930 X 350 990 x 940 x 320 990 x 940 x 320
Dimension
Outdoor
(H x W x D)
Packaging mm 679 X 992 X 414 760 X 1084 X 473 760 X 1084 X 473 1126 X 1003 X 396 1126 X 1003 X 396
Unit kg 37 40 40 62 62
Machine Weight
Gross kg 41 45 45 68 68
Liquid mm 9.5 9.5 9.5 9.5 9.5
Pipe Connection
Gas mm 15.9 15.9 15.9 15.9 15.9
Maximum Piping Length m 30 50 50 50 50
Maximum Piping Elevation m 15 30 30 30 30
Heat Insulation Both Liquid and Gas Piping
Remarks:
1. Due to product innovation, all specifications are subjected to change by the manufacturer without prior notice.
2. All units are being tested and comply to ISO5151.
3. Nominal cooling capacity are based on the conditions: 27°C DB / 19°C WB indoor and 35°C DB outdoor.
4. Sound pressure levels are measured in anechoic chamber. During actual operation, sound pressure level will be higher as a result of room specification condition.
Optional Accessories
Optional Accessories Model Name / Part Number
Wired (SHIRO) Controller BRC51D61
Intelligent Touch Manager (iTM) Controller DCM601A51
Interface Adaptor for Intelligent Touch Manager (iTM) KRP928BB2S
13
NOTES
14
Authorised Dealer:
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.
www.daikinmalaysia.com
Head office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-Ku, Osaka, 530-8323 Japan.
Note: Specifications, design and other content appearing in this brochure are current as of July 2021 by subject to change without prior notice. © All rights reserved