0% found this document useful (0 votes)
48 views1 page

Final Safty Equipment and Escape Route, Hac Layout-Model

The document outlines the layout and various areas of the Cipla manufacturing facility in Goa, specifically focusing on the manufacturing corridor and associated rooms for vial washing, filling, and sterilization. It includes details about different sections such as clean areas, storage, inspection, and service areas, as well as equipment like autoclaves and lyophilizers. The layout emphasizes the flow of materials and personnel through the facility to maintain sterile conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views1 page

Final Safty Equipment and Escape Route, Hac Layout-Model

The document outlines the layout and various areas of the Cipla manufacturing facility in Goa, specifically focusing on the manufacturing corridor and associated rooms for vial washing, filling, and sterilization. It includes details about different sections such as clean areas, storage, inspection, and service areas, as well as equipment like autoclaves and lyophilizers. The layout emphasizes the flow of materials and personnel through the facility to maintain sterile conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Cipla

Goa
Unit: V

ED

ST-7 CM

MANUFACTURING CORRIDOR-III
M M LINE IV M M M
ED
M STAIRCASE

CM
CM
DUCT
CIP/SIP
5170 DRAIN

CROSS OVER BENCH


VIAL WASHING 5074 5099
LINE SKID
CHANGE M VIAL FILLING,LYO LOADING AND M ST-6
M UNLOADING AREA
ROOM VIAL WASHING AND
(LINE-IV) DEPYROGENATION AREA M
(LINE-IV)
(LINE-IV)
M
M 5070 PROVISION
WATER SYSTEM FOR LIFT
M LOCK
AREA AIR M
STAIRCASE 5069 (GROUND FLOOR)
5068 5073
INSPECTED VIALS

CM
EMPTY VIAL M PRODUCTION
STORAGE & LOADING
INSPECTION AREA M OFFICE
AREA
(LINE-IV)
(LINE-IV)

CRASH PANEL
5111 M M
ED HATCH DOOR
LAUNDRY AREA
AIR LOCK
(GROUNDM FLOOR) 5082 5083 M SERVICE AREA M

CROSS OVER BENCH


CPSA CHANGE 5101
CPSA CHANGE M
DPB ROOM-I ROOM-II LOADING VHP PASS BOX
5100 LYOPHILIZER SERVICE AREA-I
M (LINE-IV) 5098 (LINE-IV)
(LINE-IV) SIDE WIDTH VIAL
UNLOADING
1750MM
M SIDE WIDTH SEALING

CPSA CLEAN CORRIDOR


5193

MANUFACTURING CORRIDOR-III
5077 SERVICE AREA COOLING AREA M M
ZONE AREA (LINE-IV) MISCELLENEOUS 5194
COMPONENT PREPARATION AND

FEDEGARI AUTOCLAVE
(LINE-IV) M CONSUMABLE STORAGE AREA
STERILIZATION AREA-CPSA INSTRUMENT

(LINE-IV)
5081 STORAGE AREA

5078
CLEAN LIFT (LINE-IV) M
CPSA CLEAN EQUIPMENT M
HOLD AREA PPE

(LINE-IV)

SLIDING DOOR

STERILE CORRIDOR
5172
M

PACKING CORRIDOR-II
M CONTROL ROOM

(LINE-IV)
DECONTAMINATION (LINE-IV)
5072 CHANGE
M 5171 M
ROOM 5102 M
SCRAP 5167 DPB M EMPTY TRAYS STORAGE
5079 VIAL COLLECTION
COLLECTION AREA AREA AREA
UNIT DECONTAMINATION (LINE-IV) M
(GROUND FLOOR) PREPARTION AREA (LINE-IV) 5104
AREA
(LINE-IV) (LINE-IV)

DPB
M
M FINISHED GOODS STORE
M M
5168 5091
MIRROR
M 5090
5067 M M 5095

DPB
FILLING CHANGE FILLING
DPB CPSA TRANSFER M STERILE CORRIDOR M ROOM-III CHANGE
TOWARDS AIRLOCK (LINE-IV) (LINE-IV)

HATCH
ROOM-II
EXIT (LINE-IV) M
DPB (LINE-IV)
CROSS OVER BENCH
5087 5093 M
5092
COMPOUNDING DPB DPB FILLING FILLING
5086 CHANGE
5097 5096 RETURN RETURN
COMPOUNDING ROOM-III M
M (LINE-IV) STERILE FILTRATION M
FILLING HOLD AREA CHANGE CHANGE
CHANGE M
AREA M (LINE-IV) ROOM-I ROOM-II
ROOM-II M
(LINE-IV) (LINE-IV) (LINE-IV)
(LINE-IV) M
5169
5123
COMPOUNDING AREA

CROSSOVER BENCH
5085 M (LINE-IV) 5071 5089 CONDENSATE
COMPOUNDING M 5094 FILLING
PRODUCTION OFFICE FILLING MAIN RECOVERY ROOM
MCHANGE FFU CHANGE

IPA stand
ROOM-I M 5066 M
AIR LOCK ROOM-I M
MFG (LINE-IV) (LINE-IV)
M (LINE-IV) VESSEL M E-ROOM (LINE-IV)
TOWARDS (LINE-IV)
LINE-IV
CM M
MANUFACTURING CORRIDOR-III

LINE III

ED
M M M M M

ED CM 5106
MANUFACTURING CORRIDOR-III 5011
PPE
A/L-6
VIAL WASHING AND
DEPYROGENATION AREA 5033
LYOPHILIZER SERVICE AREA M
(LINE-III) 5104
M (LINE-III) FINISHED GOODS STORE
5015 LOADING BAY SPB
EMPTY VIAL M CH ROOM
ACCESSORIES AND INSPECTION AREA
CONSUMABLE STORAGE AREA M 5030 5105
(LINE-III)
M LYOPHILIZER
M VIAL FILLING ,LYO LOADING
M 5166 M SHUTTER
AND UNLOADING AREA
(LINE-III) 527
UNLOADING PLATFORM

M
DPB

M
COMPONENT PREPARATION
AND STERLISATION AREA-CPSA
2100MM WIDE CORRIDOR

(LINE-III) VHP UP
PASS BOX
M
MANUFACTURING CORRIDOR-II

5032
Autoclave
5031 VIALS COLLECTION AREA

CM
Service
M area FFU (LINE-III)
M
M
VIAL SEALING
5034 5157 5029 AREA
M Steam 5109
WFI ROOM -II M Sterilizer COOLING (LINE-III)
ZONE AREA
(LINE-III) M
FINISHED GOODS COLD STORAGE

PACKING CORRIDOR-II
M M Mirror

STERILE CORRIDOR
M 5024
Mirror

(LINE-III)
Autoclave FILLING
5156 Service CHANGE CROSSOVER BENCH
area
PPE CPSA FILLING M
ROOM-III
5158 HOLD AREA 5023
CHANGE (LINE-III) M
ROOM DECONTAMINATION (LINE-III) FILLING
5010 CHANGE ROOM DPB CHANGE
M (LINE-III) (LINE-III)
UNIT M 5162M ROOM-II
PREPARTION AREA 5159
DPB (LINE-III) M (LINE-III)
5059 DECONTAMINATION
M
MEDIA STORAGE ROOM AREA
(LINE-III) M
5161 SGC
COMMON STERILE CORRIDOR
M
AIR LOCK (LINE-III)
M
(LINE-III) Mirror
CM

5022
CM

5025
DPB

DPB
CROSSOVER BENCH
M FILLING
FILLING
M
RETURN
5016 CHANGE
MOBILE RACK DPB M
5056 CHANGE
ROOM-I
COMPOUNDING M ROOM-I
M
CHANGE
M ROOM-I STERILE FILTRATION (LINE-III) (LINE-III)
(LINE-III) AREA
(LINE-III)
Mirror

M
5160
COMPOUNDING AREA 5036 5021
M M
(LINE-III) 5163 FILLING
5017 M E ROOM RETURN
MOBILE RACK FILLING MAIN
COMPOUNDING (LINE-III) CHANGE M
CHANGE ROOM-II M AIR LOCK
M ROOM-II
(LINE-III) (LINE-III) (LINE-III)
5050
M
QA DOCUMENT ROOM DPB

STAIRCASE
MOBILE RACK M M M
MANUFACTURING CORRIDOR-II

DPB
M

PPE CM
5058
M
PPE PACKING HALL
MOBILE RACK M 5183 M TERMINAL
STERILIZATION UNLOADING AREA
STAGING AREA SPARE AND CHANGE PARTS STORAGE AREA
PACKING CORRIDOR R-II
(PRODUCTION) M
5182
5164 M
SERVICE AREA

CM

TERMINAL

ST-3 STERILIZER
M

JANITOR
ROOM (PRODUCTION) TERMINAL
M 5142 M STERILIZATION LOADING AREA
M M
CM

M
EQUIPMENT & ACCESSORIES STORAGE ROOM 5165
5181
M
M

CM

MANUFACTURING CORRIDOR-I
SHAFT M LINE II M
M
ED

M
M
EXTRACT

201 EXTRACT

EMPTY VIAL 224 VIAL


INSPECTION COLLECTION
VIAL SEALING
206 5047
5146 DPB
VIAL FILING & 225
Filter
CHANNEL-80

VIAL WASH &


CONE-80

APPROVED EXTRACT
LYO LOADING AREA
Storage Room DEPYROGENATION
RAW MATERIAL EXTRACT

DPB
STORE-II
PACKING CORRIDOR-I

202 Q.A ROOM


RUBBER STOPPER
& SEAL WASH A31/R2
5057
EXTRACT EXTRACT EXTRACT HATCH DOOR
EXTRACT EXTRACT EXTRACT
EXTRACT

A30/R10

207 208 221


EXTRACT EXTRACT

DPB 203 COMPONENT 226


282 5148 COOLING ZONE 535
CLEAN EQUIPMENT STERILIZATION LYOPHILIZER
WASHING AREA
CLEAN CORRIDOR

5147
EXTRACT

ACTIVE DISP. HOLD SERVICE AREA TRAINING ROOM


DPB

CH.ROOM ACTIVE DISPENSING M


ROOM EXTRACT EXTRACT EXTRACT EXTRACT EXTRACT EXTRACT
5048
BIO SAFETY
CABINET

209
EXTRACT

204 STERILE
DECONTAMINATION DPB
MANUFACTURING CORRIDOR-I

5006 DPB CORRIDOR


MAIN A/L ROOM
WASHING AREA
17.00 X 2.20 METER

CHANGE ROOM 537


DPB DPB
CH. ROOM DPB EXTRACT
EXTRACT EXTRACT
CONFERENCE ROOM
EXTRACT EXTRACT EXTRACT 217
266
EXTRACT

212 BUFFER A/L 5128


EXTRACT

538
265 EXCIPIENT 205
CH.ROOM III CH-III QA ROOM-II
DISPENSING UNIT PREPARATION
VLCS
EXTRACT 213 RB
RB
MFG
CORRIDOR

211 COMPOUNDING ROOM VESSEL


DPB RLAF
CH.ROOM II FILTRATION
EXTRACT

EXTRACT

EXTRACT

EXTRACT
EXTRACT

RET.CH.ROOM-I
EXTRACT

M 210 ROOM
EXTRACT

219
EXTRACT

CH.ROOM I 5129 CHANGE


SGC DPB ROOM-II
EXTRACT SGC EXTRACT EXTRACT EXTRACT
EXTRACT

CHANGE 5127
PRE
MANUFACTURING CORRIDOR-I ROOM-I
CHANGE
M
5145
M ROOM 5126
EXTRACT

EXTRACT

CORRIDOR
APPROVED 5125
RAW MATERIAL EXTRACT

STORE-I

539

M DOCUMENTATION
M M M
CM

540
INCUBATION
MANUFACTURING CORRIDOR-I

WORK IN
COLD STORAGE

DEEP FREEZER

COLD
STORAGE ROOM PROGRESS ROOM

5178 5177

BIO SAFETY DPB


CABINET

ACTIVE SAMPLING
PACKING CORRIDOR-I

5116 DPB
5144 M M M
APPROVED RAW MATERIAL
STORES-III
PILASTER-80

LOW HUMIDITY
GLOVE VBOX
M
5117
CH.ROOM
CHANNEL-80

PILASTER-80

5118 CYLINDER MANIFOLD


RM VISUAL
X-RAY INSPECTION ROOM-I
MISCELLANEOUS INSPECTION ROOM ROOM FOR QC
VISUAL
542
STORE 5176 5174 EXTERIOR SURFACE
INSPECTION ROOM-II
CLEANING ROOM
PILASTER-80

5175 SECONDARY P.M.STORES


280 5173

CH.ROOM M

279 DPB
SAMPLING 5143
UNLOADING PLATFORM

EXCIPIENT M
DPB
PRODUCTION
RLAF
OFFICE
ROLLING
SHUTTER

5141 BUFFER AIR


AIR LOCK-III AIR LOCK-II AIR LOCK-I
LIFT ED
PACKING CORRDOR-I
ED 5139
5140
SPB
E.W.C.

5184
549
A/L-5
P.M.TESTING 308
PRODUCTION DEDUSTING ED
322 DN
MANUFACTURING PACKING E.W.C.
LADIES CHANGE ROOM 311 OFFICE
ST-1 CHANGE ROOM CHANGE ROOM 550
321
I.W.C.
LINEN VISITORS
DUCT LADIES
STORES CHANGE
5137 5138 ROOM TOILET 5130 UP
BOOTY LOCKERS
9 NO. x 12 High

Q.C.LADIES CHANGE ROOM

SHOWER

DN

SPB
5131
STREET
UP DN SHOE CORRIDOR Q.C.GENTS CHANGE ROOM
VISITORS CORRIDOR
STAIRCASE ST-2
CRASH PANEL

ENTRANCE LOBBY
CHANGE ROOM
5133 STAIRCASE
ED LOBBY AREA

5134
Service Door

WASH AREA CORRIDOR


SANDAL
WASH ROOM

5135

TOILET
MALE 5124
5179
STORAGE
LINEN WC WC WC WC WC/SHOWER ROOM
STORAGE ROOM
5136

LEGENDS
SYMBOLS DESCRIPTION

OXYGEN GAS DETECTOR

ED
EMERGENCY DOOR

SELF CONTAINED BREATHING APPRATUS


LEGENDS
MANUAL CALL POINT
M/S. CIPLA LTD. (UNIT-V)
EMERGENCY DOOR
FIRST AID BOX SAFETY EQUIPMENTS AND ESCAPE ROUTE AND HAZARDOUS AREA
SINGLE DOOR WITH DIRECTION
OF OPENING TOWARDS
CLASSIFICATION LAYOUT-GROUND FLOOR
FIRE EXTINGUISHER
DRAWING NO. U5/GF/17 VERSION NUMBER 00
FIRE ESCAPE HYDRANT DOUBLE DOOR WITH DIRECTION
OF OPENING TOWARDS PREPARED BY REVIEWED BY
EMERGENCY EVACUATION ROUTE Unit Engineer Engg Department Head
ZONE 20: WITHIN 1M SOURCES OF
Date Date
M ADDRESSABLE MULTISENSOR DETECTOR (SMOKE CUM HEAT) RELEASE

SMOKE DETECTOR
ZONE 21: ABOVE 1M AFTER ZONE Z20 REVIEWED BY REVIEWED BY
User Department Head EHS Department
ZONE 22: AFTER ZONE Z21/SOURCES
HEAT DETECTOR OF RELEASE Date Date
ZONE 0 : WITHIN 1M SOURCES OF
PPE PERSONAL PROTECTIVE EQUIPMENTS BOX
RELEASE REVIEWED BY APPROVED BY
Quality Assurance Unit Head
CM CONTROL MODULE ZONE 1: ABOVE 1M AFTER ZONE Z0 Date
Date
PUBLIC ADDRESS SYSTEM ZONE 2: AFTER ZONE Z1/SOURCES OF APPROVED BY
N PUBLIC ADDRESS HOOTER
RELEASE
Head Unit QA
Date
FIRE ALARM
DATE OF EFFECTIVE

(EP-044/F2/5)