0% found this document useful (0 votes)
30 views4 pages

TERRACE LVL FRAMING & BEAM-SLAB DETA - VILLA - CL-01 - UPPER BLOCK (VUB-01 TO 04) - SH-1-merged

The document provides detailed structural guidelines for the construction of a resort in Udaipur, including specifications for dimensions, materials, and reinforcement bars. It outlines the beam layout, concrete grade, and requirements for filling sunken areas, as well as reinforcement details for slabs and beams. Compliance with relevant Indian standards is emphasized throughout the document.

Uploaded by

imrancreative269
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views4 pages

TERRACE LVL FRAMING & BEAM-SLAB DETA - VILLA - CL-01 - UPPER BLOCK (VUB-01 TO 04) - SH-1-merged

The document provides detailed structural guidelines for the construction of a resort in Udaipur, including specifications for dimensions, materials, and reinforcement bars. It outlines the beam layout, concrete grade, and requirements for filling sunken areas, as well as reinforcement details for slabs and beams. Compliance with relevant Indian standards is emphasized throughout the document.

Uploaded by

imrancreative269
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

NOTES:-

1 ALL DIMENSIONS SHOWN ARE IN MM. (UNLESS MENTIONED).


2 FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT MEASURE ANY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DIMENSION.
3 PROVIDED 2-12T (T&B) IN SLABS UNDERNEATH MASONARY WALLS
WHEREVER NO BEAM IS PROVIDED.
4 FE 550D COMPLIANCE TO IS : 1786 (LATEST REVISION) SHALL BE
USED FOR ALL REINFORCEMENT BARS.
A 5 FOR CONCRETE WORK USE CONCRETE GRADE OF M30 COMPLIANCE
R1 TO IS : 456 (LATEST REVISION).
B 6 BEAM LAYOUT SHALL BE AS FOLLOWS:
A. BEAMS SHALL BE PLACED TO COLUMN FACE OR
B. BEAMS SHALL BE PLACED AS PER MASONARY LAYOUT GIVEN IN
C ARCHTECTURAL DRAWING OR
X
C. BEAMS SHALL BE PLACED AS PER DIMENSIONS GIVEN FROM
D
GRIDS TO FACE OF BEAM IN THE FRAMING PLAN.
X
D. ALL SECONDRY BEAMS SHALL BE PLACED IN BETWEEN PRIMARY
E BEAMS (UNLESSS MENTIONED).
7 ALL SUNKEN AREAS SHALL BE FILLED WITH LIGHT WEIGHT MATERIAL.
Z 8 DOWEL BARS FOR ELEVATION FEATURE / FUTURE CONSTRUCTION
F SHALL BE PROVIDED WHILE CASTING WITH PROPER SHEAR KEY.

G Z R1
P X
W W
P
H
R1 X W' W'
R1
J Y Y

DN
K P P R1

X
X X
L MUMTY LVL FRAMING PLAN

X
M

N
P X X

STRUCTURAL REFERENCE DRAWINGS

X
Q

X
PROJECT :-

TERRACE LVL FRAMING PLAN RESORT, UDAIPUR


FOR MIRAJ GROUP
CLIENT :-

SECTION Z-Z

ARCHITECT :-

SANJAY PURI
ARCHITECTS

SECTION W-W DRAWING TITLE TERRACE LVL. FRAMING PLAN


SHEET NO.
DRAWING NO. :- 7 0 9 2 2 1 5 0 1
SCALE: DATE: REVISION NO. :-

DRAWN BY: DESIGNED BY: APPROVED BY :-

STATUS :- GOOD FOR CONSTRUCTION

STRUCTURAL CONSULTANT :-

SECTION Y-Y
SECTION T-T SECTION X-X (TYPICAL)
212, TOWER-A , I-THUM A-40 SECTOR-62
SECTION P-P (TYPICAL) SECTION W'-W' NOIDA - 201301, UTTAR PRADESH
NOTES:-
1. ALL DIMENSIONS SHOWN ARE IN MM. (UNLESS MENTIONED).
2. FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT MEASURE ANY
DIMENSION.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 3. PROVIDED 2-12T (T&B) IN SLABS UNDERNEATH MASONARY WALLS


WHEREVER NO BEAM IS PROVIDED.
4. FE 500D COMPLIANCE TO IS : 1786 (LATEST REVISION) SHALL BE USED
FOR ALL REINFORCEMENT BARS.
5. FOR CONCRETE WORK USE CONCRETE GRADE OF M30 COMPLIANCE
TO IS : 456 (LATEST REVISION).
A
6. BEAM LAYOUT SHALL BE AS FOLLOWS:
A. BEAMS SHALL BE PLACED TO COLUMN FACE OR
B
B. BEAMS SHALL BE PLACED AS PER MASONARY LAYOUT GIVEN IN
ARCHTECTURAL DRAWING OR
C C. BEAMS SHALL BE PLACED AS PER DIMENSIONS GIVEN FROM
GRIDS TO FACE OF BEAM IN THE FRAMING PLAN.
D D. ALL SECONDRY BEAMS SHALL BE PLACED IN BETWEEN PRIMARY
BEAMS (UNLESSS MENTIONED).
E 7. ALL SUNKEN AREAS SHALL BE FILLED WITH LIGHT WEIGHT MATERIAL.
8. DOWEL BARS FOR ELEVATION FEATURE / FUTURE CONSTRUCTION
SHALL BE PROVIDED WHILE CASTING WITH PROPER SHEAR KEY.
F 9. INDICATES DIRECTION OF SPANNING OF SLAB
10 . BOTTOM BARS.
11 . TOP BARS.
G
12. CLEAR COVER TO SLAB R/F SHALL BE 20mm.
13. INDICATES SLAB THICKNESS

H
J

DN
K
L
M

N
P MUMTY LVL SLAB R/F PLAN
STRUCTURAL REFERENCE DRAWINGS

PROJECT :-

RESORT, UDAIPUR
TERRACE LVL SLAB REINF. PLAN FOR MIRAJ GROUP
LEGENDS FOR REINFORCEMENT
IN SLAB :- CLIENT :-
SPA DIA
CIN
G
8 10 12 16 20

75 b1 c1 d1 e1 f1

100 b2 c2 d2 e2 f2 ARCHITECT :-

125 b3 c3 d3 e3 f3 SANJAY PURI


150 b4 c4 d4 e4 f4 ARCHITECTS
175 b5 c5 d5 e5 f5

200 b6 c6 d6 e6 f6

225 b7 c7 d7 e7 f7 DRAWING TITLE TERRACE LVL. SLAB REINF. PLAN


SHEET NO.
250 b8 c8 d8 e8 f8 DRAWING NO. :- 7 0 9 2 2 1 5 0 1
SCALE: DATE: REVISION NO. :-

GUIDELINES FOR READING DRAWN BY: DESIGNED BY: APPROVED BY :-


SLAB REINFORCEMENT :-
STATUS :- GOOD FOR CONSTRUCTION
DIAMETER OF STIRRUP BAR
SPACING OF STIRRUPS STRUCTURAL CONSULTANT :-

d 4
EXAMPLE FOR READING SLAB R/F
TYPICAL CUTOUT DETAIL d4 - INDICATE 12mm DIA BAR AT SPACING OF 150mm c/c 212, TOWER-A , I-THUM A-40 SECTOR-62
NOIDA - 201301, UTTAR PRADESH
NOTES:-
1. ALL DIMENSIONS SHOWN ARE IN MM. (UNLESS MENTIONED).
2. FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT MEASURE
ANY DIMENSION..
3. ALL BEAM SIZE SHALL CONFIRM TO FRAMING PLAN. ANY
DISCREPANCY SHALL BE BROUGHT IN NOTICE OF STRUCTURAL
CONSULTANT.
4. ALL BEAM ELEVATION SHOWN ARE TENTATIVE SAME HAS BEEN
DRAWN TO SHOW PLACEMENT OF LONGITUDINAL R/F AND
STIRRUPS ARRANGEMENT ONLY.
5. ALL BEAM ELEVATION DRAWN IN SCALE 1:50 (UNLESS MENTIONED)
6. ALL BEAM SECTION DRAWN IN SCALE 1:25 ((UNLESS MENTIONED)
7 CLEAR COVER TO BEAM R/F SHALL BE 25mm.
8. USE SPACE BAR OF 32mm DIAMETER @1500c/c FOR
MULTIPLE LAYER OF LONGITUDINAL BARS.

R1

LEGENDS FOR BEAM STIRRUP


REINFORCEMENT IN BEAMS :-
S1 2L-T8@100 C/C S11 4L-T8@100 C/C

S2 2L-T8@125 C/C S12 4L-T8@125 C/C

S3 2L-T8@150 C/C S13 4L-T8@150 C/C

S4 2L-T8@175 C/C S14 4L-T8@175 C/C

S5 2L-T8@200 C/C S15 4L-T8@200 C/C

S6 2L-T10@100 C/C S16 4L-T10@100 C/C

S7 2L-T10@125 C/C S17 4L-T10@125 C/C

S8 2L-T10@150 C/C S18 4L-T10@150 C/C

S9 2L-T10@175 C/C S19 4L-T10@175 C/C

S10 2L-T10@200 C/C S20 4L-T10@200 C/C

STRUCTURAL REFERENCE DRAWINGS

R1 R1
PROJECT :-

RESORT, UDAIPUR
FOR MIRAJ GROUP
CLIENT :-

ARCHITECT :-

R1 SANJAY PURI
ARCHITECTS

DRAWING TITLE TERRACE LVL. BEAM DETAIL


SHEET NO.
DRAWING NO. :- 7 0 9 2 2 1 5 0 1
SCALE: DATE: REVISION NO. :-

DRAWN BY: DESIGNED BY: APPROVED BY :-

STATUS :- GOOD FOR CONSTRUCTION

STRUCTURAL CONSULTANT :-

212, TOWER-A , I-THUM A-40 SECTOR-62


NOIDA - 201301, UTTAR PRADESH
NOTES:-
1. ALL DIMENSIONS SHOWN ARE IN MM. (UNLESS MENTIONED).
2. FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT MEASURE
ANY DIMENSION..
3. ALL BEAM SIZE SHALL CONFIRM TO FRAMING PLAN. ANY
DISCREPANCY SHALL BE BROUGHT IN NOTICE OF STRUCTURAL
CONSULTANT.
4. ALL BEAM ELEVATION SHOWN ARE TENTATIVE SAME HAS BEEN
DRAWN TO SHOW PLACEMENT OF LONGITUDINAL R/F AND
STIRRUPS ARRANGEMENT ONLY.
5. ALL BEAM ELEVATION DRAWN IN SCALE 1:50 (UNLESS MENTIONED)
6. ALL BEAM SECTION DRAWN IN SCALE 1:25 ((UNLESS MENTIONED)
7 CLEAR COVER TO BEAM R/F SHALL BE 25mm.
8. USE SPACE BAR OF 32mm DIAMETER @1500c/c FOR
MULTIPLE LAYER OF LONGITUDINAL BARS.

R1
LEGENDS FOR BEAM STIRRUP
REINFORCEMENT IN BEAMS :-
S1 2L-T8@100 C/C S11 4L-T8@100 C/C

S2 2L-T8@125 C/C S12 4L-T8@125 C/C

S3 2L-T8@150 C/C S13 4L-T8@150 C/C

S4 2L-T8@175 C/C S14 4L-T8@175 C/C

S5 2L-T8@200 C/C S15 4L-T8@200 C/C

S6 2L-T10@100 C/C S16 4L-T10@100 C/C

S7 2L-T10@125 C/C S17 4L-T10@125 C/C

R1 S8 2L-T10@150 C/C S18 4L-T10@150 C/C

S9 2L-T10@175 C/C S19 4L-T10@175 C/C

S10 2L-T10@200 C/C S20 4L-T10@200 C/C

STRUCTURAL REFERENCE DRAWINGS

PROJECT :-

RESORT, UDAIPUR
FOR MIRAJ GROUP
CLIENT :-

ARCHITECT :-

SANJAY PURI
ARCHITECTS

DRAWING TITLE TERRACE LVL. BEAM DETAIL


SHEET NO.
DRAWING NO. :- 7 0 9 2 2 1 5 0 1
SCALE: DATE: REVISION NO. :-

DRAWN BY: DESIGNED BY: APPROVED BY :-

STATUS :- GOOD FOR CONSTRUCTION

STRUCTURAL CONSULTANT :-

212, TOWER-A , I-THUM A-40 SECTOR-62


NOIDA - 201301, UTTAR PRADESH

You might also like