HST4 Expansion anchor
Product Technical Datasheet
Steel-to-concrete
Update: Dec 24
HST4 Wedge expansion anchor
High-performance expansion anchor
Anchor version Benefits
- High capacity anchor with ability to be
used in reduced member thickness,
HST4 small spacing and edge distances
HST4-R - Suitable for uncracked and cracked
(M8-M20) concrete C20/25 to C50/60
- Tested and approved for structural
seismic design with ETA C1/C2
assessment
- Longer embedment depth option to get
HST4 DN higher resistance, closer distance to the
HST4-R DN edge or smaller spacing
(M8-M16) - Full design flexibility with variable
embedment depth and edge & spacing
- Faster and reliable installation thanks to
approved non-cleaning and adaptive
torqueing tool
HST4 BW - Dome-nut variant available for more
HST4-R BW aesthetic application finish
(M8 - M16)
- Product length identification mark
facilitates quality control and inspection
Base material Load conditions
Concrete Concrete Steel fiber Static/ Seismic Shock Fire
(uncracked) (cracked) reinforced quasi-static C1/C2 BZS-CH resistance
concrete
(SFRC)
Drilling, cleaning, setting Other information
Hammer Diamond Hollow Impact wrench Variable PROFIS Steel to concrete
drilled holes drilled holes drill-bit drilling with adaptative embedment Engineering Handbook
(with no torque module depth software
cleaning)
Update:Dec-24 2
Linked Approvals/Certificates and Instructions for use
Approvals/certificates
Application / loading Authority /
Approval no Date of issue Date of expiry
condition Laboratory
Static and quasi-static / CSTB,
ETA-21/0878 31-10-2024 -
Seismic / Fire Marne-la-Vallée
GS 6.1/22-065-3-r1
Fire data ZTV-ING Tunnel MFPA, Leipzig 30-11-2023 -
(HST4-R)
BZS D 24-602
Shock approval FOCP, Spiez 25-08-2024 31-12-2033
(HST4-R)
The instructions for use can be viewed using the link in the instructions for use table or the QR code/link
in the Hilti webpage table.
Instructions for use
Anchor size M8 M10 M12 M16 M20
HST4 IFU HST4-M8 IFU HST4- M10 IFU HST4- M12 IFU HST4- M16 IFU HST4- M20
HST4-R IFU HST4-R M8 IFU HST4-R M10 IFU HST4-R M12 IFU HST4-R M16 IFU HST4-R M20
Filling set Filling Set
Link to Hilti Webpage
HST4 HST4-R HST4 DN HST4-R DN HST4 BW HST4-R BW
Update:Dec-24 3
Fastener special dimensions
Anchor size M8 M10 M12 M16 M20
Maximum length of anchor L [mm] 115 180 260 260 260
Outer diameter of washer dw ≥ [mm] 16 20 24 30 37
Outer diameter of big washer
dW ≥ [mm] 24 30 37 50 -
version (BW)
HST4(-R) (M8-M16)
HST4(-R) M20
Dimensions of the Dome nut
Anchor size M8 M10 M12 M16
Length of dome nut thread Lthreadmin [mm] 13,3 16,8 17,8 22,3
Length of dome nut LDNmin [mm] 18,1 21,9 24,0 29,5
Update:Dec-24 4
Hilti filling set with Injection mortar Hilti HIT-HY…
Dimensions filling washer
Anchor size M8 M10 M12 M16 M20
Diameter dvs [mm] 38 42 44 52 60
Height filling washer hvs [mm] 5 5 5 6 6
Height filling washer and
hfs [mm] 8 9 10 11 13
spherical washer
Update:Dec-24 5
Static and quasi-static loading based on ETA-21/0878. Design according to EN 1992-4
All data in this section applies to:
- Correct setting (See setting instruction)
- For a single anchor
- Concrete C20/25 with and without steel fibers (SFRC)
- No edge distance and spacing influence (see table with characteristic distances)
- Characteristic spacing and edge distance for splitting failure apply only for uncracked concrete.
- For cracked concrete only the characteristic spacing and edge distance for concrete cone failure are decisive
- Minimum base material thickness (see setting detail table)
- Embedment depth, as specified in the table of this section
- Anchor material, as specified in the tables of this section
- Hammer drilled holes,hammer drilled holes with Hilti hollow drill bit (M10-M20),
diamond cored holes (only for HST4-R)
- Recommended loads: With overall partial safety factor for action γ = 1,4.
Note: Embedment depths hef<40 mm are applicable only for fastening of redundant non-structural systems as
addressed in EN 1992-4, Clause 7.3 and CEN/TR 17079. For other types of fastenings please increase the
embedment depth.
For specific design cases refer to PROFIS Engineering
Design resistance
Anchor size M8 M10 M12 M16 M20
Effective
hef [mm] 301) 47 90 301) 60 100 40 70 125 65 85 160 101 120 180
anchorage depth
Uncracked concrete
HST4 5,4 10,6 12,7 5,8 16,4 20,0 9,6 22,2 28,0 19,8 29,7 36,7 33,3 33,3 33,3
Tension NRd [kN]
HST4-R 5,4 10,6 12,7 6,2 17,6 21,3 9,6 22,2 30,7 19,8 29,7 40,0 33,3 33,3 33,3
HST4 11,0 13,0 13,0 10,8 19,8 19,8 23,9 29,9 29,9 50,3 50,3 50,3 67,1 67,1 67,1
Shear VRd [kN]
HST4-R 11,0 13,9 13,9 11,6 22,0 22,0 23,9 33,0 33,0 57,9 57,9 57,9 77,8 77,8 77,8
Cracked concrete
HST4 3,8 7,4 8,0 4,4 12,3 12,7 6,7 15,5 18,7 13,9 20,8 25,3 23,3 23,3 23,3
Tension NRd [kN]
HST4-R 3,8 6,7 6,7 4,4 12,3 13,3 6,7 15,5 18,7 13,9 20,8 25,3 23,3 23,3 23,3
HST4 7,7 13,0 13,0 8,1 19,8 19,8 16,8 29,9 29,9 41,7 50,3 50,3 67,1 67,1 67,1
Shear VRd [kN]
HST4-R 7,7 13,9 13,9 8,1 22,0 22,0 16,8 33,0 33,0 41,7 57,9 57,9 74,6 77,8 77,8
Recommended loads
Anchor size M8 M10 M12 M16 M20
Effective
hef [mm] 301) 47 90 301) 60 100 40 70 125 65 85 160 101 120 180
anchorage depth
Uncracked concrete
HST4 1) 7,5 9,0 1) 11,7 14,3 6,8 15,8 20,0 14,2 21,2 26,2 23,8 23,8 23,8
Tension Nrec [kN]
HST4-R 1) 7,5 9,0 1) 12,6 15,2 6,8 15,8 21,9 14,2 21,2 28,6 23,8 23,8 23,8
HST4 1) 9,3 9,3 1) 14,2 14,2 17,1 21,4 21,4 35,9 35,9 35,9 47,9 47,9 47,9
Shear Vrec [kN]
HST4-R 1) 9,9 9,9 1) 15,7 15,7 17,1 23,6 23,6 41,4 41,4 41,4 55,5 55,5 55,5
Cracked concrete
HST4 1) 5,3 5,7 1) 8,8 9,0 4,8 11,1 13,3 9,9 14,9 18,1 16,6 16,7 16,7
Tension Nrec [kN]
HST4-R 1) 4,8 4,8 1) 8,8 9,5 4,8 11,1 13,3 9,9 14,9 18,1 16,6 16,7 16,7
HST4 1) 9,3 9,3 1) 14,2 14,2 12,0 21,4 21,4 29,8 35,9 35,9 47,9 47,9 47,9
Shear Vrec [kN]
HST4-R 1) 9,9 9,9 1)15,7 15,7 12,0 23,6 23,6 29,8 41,4 41,4 53,3 55,5 55,5
1) Please refer “Requirements for redundant fastening“ section
Update:Dec-24 6
Requirements for redundant fastening
The definition of redundant fastening according to Member States is given in EN 1992-4 and CEN/TR 17079. In
Absence of a definition by a Member State the following default values may be taken.
Minimum number Minimum number of anchors per Maximum design load of action
of fixing points fixing point FSd per fixing point
3 1 2 kN
4 1 3 kN
The value for maximum design load of actions per fastening point FSd is valid in general that means all fastening
points are considered in the design of the redundant structural system. FSd can be a tension, shear or inclined load.
Update:Dec-24 7
Seismic loading based on ETA-21/0878. Design according to EN 1992-4
All data in this section applies to:
- Correct setting (See setting instruction)
- For a single anchor
- Concrete C20/25 (with Steel fibers (SFRC) applicable for category C1 only)
- No edge distance and spacing influence (see table with characteristic distances)
- Characteristic spacing and edge distance for splitting failure apply only for uncracked concrete.
- For cracked concrete only the characteristic spacing and edge distance for concrete cone failure are decisive
- Minimum base material thickness (see table)
- Embedment depth, as specified in the table of this section
- Anchor material, as specified in the tables of this section
- Hammer drilled, hammer drilled holes with Hilti hollow drill bit (M10-M20) and
diamond cored holes (only for HST4-R)
- αgap = 1,0 (using Hilti filling set) and αgap = 0,5 (without using Hilti filling set) accordingly
For specific design cases refer to PROFIS Engineering.
Design resistance in case of seismic performance C2
Anchor size M8 M10 M12 M16 M20
Effective
hef [mm] 47 90 60 100 40 70 125 65 85 160 101 120 180
anchorage depth
with and without Hilti filling set
HST4 2,9 3,1 8,3 8,3 5,6 13,2 14,4 11,8 17,7 25,5 19,8 23,3 23,3
Tension NRd,C2 [kN]
HST4-R 3,0 3,3 8,4 8,5 5,7 13,2 14,7 11,8 17,7 24,5 19,8 23,3 23,3
with Hilti filling set (αgap = 1,0)
HST4 8,6 8,6 14,2 14,2 14,3 21,2 21,2 31,1 35,9 35,9 63,4 67,4 67,4
Shear VRd,C2 [kN]
HST4-R 8,2 8,2 14,9 15,0 14,3 19,2 19,2 35,5 41,0 41,0 53,9 53,9 53,9
without Hilti filling set (αgap = 0,5)
HST4 4,3 4,3 7,1 7,1 7,1 10,6 10,6 15,6 18,0 18,0 26,8 26,8 26,8
Shear VRd,C2 [kN]
HST4-R 4,1 4,1 7,5 7,5 7,1 9,6 9,6 17,7 20,5 20,5 19,8 19,8 19,8
Design resistance in case of seismic performance C1
Anchor size M8 M10 M12 M16 M20
Effective
hef [mm] 47 90 60 100 40 70 125 65 85 160 101 120 180
anchorage depth
with and without Hilti filling set
HST4 6,3 7,5 10,5 12,1 5,7 13,2 17,5 11,8 17,7 24,7 19,8 23,3 23,3
Tension NRd,C1 [kN]
HST4-R 6,2 6,2 10,5 12,7 5,7 13,2 17,5 11,8 17,7 24,7 19,8 23,3 23,3
with Hilti filling set (αgap = 1,0)
HST4 10,7 10,7 17,6 17,6 14,3 26,5 26,5 33,2 40,1 40,1 63,4 80,3 80,3
Shear VRd,C1 [kN]
HST4-R 12,6 12,6 18,6 18,6 14,3 31,9 31,9 35,5 48,6 48,6 63,4 82,1 82,2
without Hilti filling set (αgap = 0,5)
HST4 5,4 5,4 8,8 8,8 7,1 13,3 13,3 16,6 20,0 20,1 31,0 31,0 31,0
Shear VRd,C1 [kN]
HST4-R 6,3 6,3 9,3 9,3 7,1 16,0 16,0 17,7 24,3 24,3 22,7 22,7 22,7
Update:Dec-24 8
Fire resistance based on ETA-21/0878. Design according to EN 1992-4
All data in this section applies to:
- Correct setting (See setting instruction)
- For a single anchor
- Concrete C20/25 with and without steel fibers (SFRC)
- No edge distance and spacing influence (see table with characteristic distances)
- Characteristic spacing and edge distance for splitting failure apply only for uncracked concrete.
- For cracked concrete only the characteristic spacing and edge distance for concrete cone failure are decisive
- Minimum base material thickness (see table)
- Embedment depth, as specified in the table of this section
- Anchor material, as specified in the tables of this section
- hammer drilled, hammer drilled holes with Hilti hollow drill bit (M10-M20) and
diamond cored holes (only for HST4-R)
- Partial safety factor for resistance under fire exposure 𝛾𝛾𝑀𝑀,𝑓𝑓𝑓𝑓 = 1,0
Note: Embedment depths hef<40 mm are applicable only for fastening of redundant non-structural systems as
addressed in EN 1992-4, Clause 7.3 and CEN/TR 17079. For other types of fastenings please increase the
embedment depth.
For specific design cases refer to PROFIS Engineering.
Design resistance in case of fire
Anchor size M8 M10 M12 M16 M20
Effective
hef [mm] 301) 47 90 30 60 100 40 70 125 65 85 160 101 120 180
anchorage depth
Fire Exposure R30
HST4 0,8 0,9 0,9 1,0 2,4 2,4 2,0 5,2 5,2 4,4 9,5 9,5 9,1 9,1 9,1
Tension NRd,fi(30) [kN]
HST4-R 0,8 2,5 2,5 1,0 5,0 5,0 2,0 7,0 7,0 6,8 9,5 9,5 9,1 9,1 9,1
HST4 0,9 0,9 0,9 1,5 2,4 2,4 2,3 5,2 5,2 4,4 9,7 9,7 15,2 15,2 15,2
Shear VRd,fi(30) [kN]
HST4-R 1,7 4,9 4,9 1,8 11,1 11,8 5,0 17,1 17,1 16,9 31,9 31,9 49,8 49,8 49,8
Fire Exposure R60
HST4 0,8 0,8 0,8 1,0 1,8 1,8 1,7 3,7 3,7 3,2 6,8 6,8 9,1 9,1 9,1
Tension NRd,fi(60) [kN]
HST4-R 0,8 2,5 2,5 1,0 5,0 5,0 2,0 7,0 7,0 6,8 9,5 9,5 9,1 9,1 9,1
HST4 0,8 0,8 0,8 1,2 1,8 1,8 1,7 3,7 3,7 3,2 6,8 6,8 10,6 10,6 10,6
Shear VRd,fi(60) [kN]
HST4-R 1,7 3,6 3,6 1,8 8,4 8,4 4,4 12,2 12,2 12,6 22,8 22,8 35,5 35,5 35,5
Fire Exposure R90
HST4 0,7 0,7 0,7 0,9 1,2 1,2 1,1 2,1 2,1 2,1 3,9 3,9 6,0 6,0 6,0
Tension NRk,fi(90) [kN]
HST4-R 0,8 2,4 2,4 1,0 5,0 5,0 2,0 7,0 7,0 6,8 9,5 9,5 9,1 9,1 9,1
HST4 0,7 0,7 0,7 0,9 1,2 1,2 1,1 2,1 2,1 2,1 3,9 3,9 6,0 6,0 6,0
Shear VRk,fi(90) [kN]
HST4-R 1,4 2,4 2,4 1,8 5,0 5,0 3,6 7,3 7,3 8,4 13,6 13,6 21,2 21,2 21,2
Fire Exposure R120
HST4 0,6 0,6 0,6 0,8 0,9 0,9 0,8 1,3 1,3 1,5 2,4 2,4 3,8 3,8 3,8
Tension NRd,fi(120) [kN]
HST4-R 0,7 1,7 1,7 0,8 3,3 3,3 1,6 4,8 4,8 5,4 7,6 7,6 7,3 7,3 7,3
HST4 0,6 0,6 0,6 0,8 0,9 0,9 0,8 1,3 1,3 1,3 2,4 2,4 3,8 3,8 3,8
Shear VRd,fi(120) [kN]
HST4-R 1,2 1,7 1,7 1,5 3,3 3,3 3,2 4,8 4,8 6,2 9,0 9,0 14,1 14,1 14,1
1) Please refer “Requirements for redundant fastening“ section
Update:Dec-24 9
Setting information
Setting details
Anchor size M8 M10 M12 M16 M20
Nominal diameter
do [mm] 8 10 12 16 20
of drill bit
Maximum diameter of
clearance hole in the df [mm] 9 12 14 18 22
fixture
Torque moment Tinst [Nm] 20 40 60 120 180
Effective anchorage
hef [mm] 30 47 90 30 60 100 40 70 125 65 85 160 101 120 180
depth
Nominal 36 53 96 38 68 108 49 79 134 77 97 172 116 135 195
hnom [mm]
embedment depth hef + 6 hef + 8 hef + 9 hef + 12 hef + 15
Drill hole depth
not 56 73 116 58 88 128 69 99 154 97 117 192 136 155 215
h1min [mm]
Hammer cleaned hnom + 20
drill 39 56 99 42 72 112 53 83 138 83 103 178 124 143 203
cleaned h1min [mm]
hnom + 3 hnom + 4 hnom + 6 hnom + 8
- 42 72 112 53 83 138 83 103 178 124 143 203
Hollow drill h1min [mm]
- hnom + 4 hnom + 6 hnom + 8
46 63 106 48 78 118 59 89 144 87 107 182 126 145 205
Diamond coring h1min [mm]
hnom + 10
Concrete thickness
hbmin [mm] 21 27 32 34 36
below bore hole
Minimum concrete max(80; max(80; max(100; max(120;
hmin [mm] 160 + hef - hef.min
thickness 1,5 hef; h1+hb) 1,5 hef; h1+hb) 1,5 hef; h1+hb) 1,5 hef; h1+hb)
Fixture thicknesses
Thickness of Hilti
hfs [mm] 8 9 10 11 13
filling set
Effective fixture
thickness with Hilti tfix,ef [mm] tfix - hfs
filling set
Characteristic distances HST4-R
Spacing for splitting scr,sp [mm] 122 200 143 173 304 218 199 306 224 381 515 368 384 456 684
failure and concrete
cone failure a) scr,N [mm] 90 141 270 90 180 300 120 210 375 195 255 480 303 360 540
Edge distance for ccr,sp [mm] 61 100 72 86 152 109 99 153 112 190 258 184 192 228 342
splitting failure and
concrete cone failure a) ccr,N [mm] 45 71 135 45 90 150 60 105 188 98 128 240 152 180 270
Characteristic distances HST4
Spacing for splitting scr,sp [mm] 114 176 126 140 210 166 168 244 186 246 336 250 384 456 684
failure and concrete
cone failure a) scr,N [mm] 90 141 270 90 180 300 120 210 375 195 255 480 303 360 540
Edge distance for ccr,sp [mm] 57 88 63 70 105 83 84 122 93 123 168 125 192 228 342
splitting failure and
concrete cone failure a) ccr,N [mm] 45 71 135 45 90 150 60 105 188 98 128 240 152 180 270
a) Values calculated under the hypothesis of uncracked concrete C20/25, cleaned, hammer drilled borehole.
Update:Dec-24 10
Minimum spacing smin, edge distance cmin and required splitting area Asp,req
We recommend checking your designs in Hilti’s PROFIS Engineering software to verify the edge & spacing values.
ETA-21/0878 provides formulae for the calculation of flexible edge & spacing for each anchor layout configuration
depending on base material thickness.
Minimum spacing and edge distance values on the tables below are recommendations for specific anchor layout
and base material dimensions.
Anchor size HST4, HST4-R M8
Effective anchorage depth hef [mm] 30 47 90
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 80 80 80 100 135 140
Uncracked concrete
smin [mm] 35 35 35 35 35 35
Minimum spacing
for cmin [mm] 70 70 70 55 45 45
cmin [mm] 40 40 40 40 40 40
Minimum edge distance
for smin [mm] 120 120 120 70 65 55
Cracked concrete
smin [mm] 35 35 35 35 35 35
Minimum spacing
for cmin [mm] 50 50 50 50 40 40
cmin [mm] 40 40 40 40 40 40
Minimum edge distance
for smin [mm] 55 55 55 35 35 35
Update:Dec-24 11
Anchor size HST4, HST4-R M10
Effective anchorage depth hef [mm] 30 60 100
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 80 90 100 115 150 155
Uncracked concrete
smin [mm] 40 40 40 40 40 40
Minimum spacing
for cmin [mm] 100 90 80 70 55 55
cmin [mm] 45 45 45 45 45 45
Minimum edge distance
for smin [mm] 205 170 140 105 100 90
Cracked concrete
smin [mm] 40 40 40 40 40 40
Minimum spacing
for cmin [mm] 80 70 65 55 50 50
cmin [mm] 45 45 45 45 45 45
Minimum edge distance
for smin [mm] 145 115 90 60 55 50
Anchor size HST4, HST4-R M12
Effective anchorage depth hef [mm] 40 70 125
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 100 105 115 135 190 190
Uncracked concrete
smin [mm] 50 50 50 50 50 50
Minimum spacing
for cmin [mm] 125 120 105 90 70 70
cmin [mm] 55 55 55 55 55 55
Minimum edge distance
for smin [mm] 255 235 200 145 120 120
Cracked concrete
smin [mm] 50 50 50 50 50 50
Minimum spacing
for cmin [mm] 95 90 80 65 60 60
cmin [mm] 55 55 55 55 55 55
Minimum edge distance
for smin [mm] 160 145 120 75 55 55
Anchor size HST4-R M16
Effective anchorage depth hef [mm] 65 85 160
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 120 135 140 155 240 240
Uncracked concrete
smin [mm] 65 65 65 65 65 65
Minimum spacing
for cmin [mm] 115 100 95 85 70 70
cmin [mm] 65 65 65 65 65 65
Minimum edge distance
for smin [mm] 210 165 150 120 80 80
Cracked concrete
smin [mm] 65 65 65 65 65 65
Minimum spacing
for cmin [mm] 100 85 80 70 65 65
cmin [mm] 65 65 65 65 65 65
Minimum edge distance
for smin [mm] 160 120 110 80 65 65
Update:Dec-24 12
Anchor size HST4 M16
Effective anchorage depth hef [mm] 65 85 160
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 120 135 140 155 240 240
Uncracked concrete
smin [mm] 65 65 65 65 65 65
Minimum spacing
for cmin [mm] 140 125 120 105 80 80
cmin [mm] 65 65 65 65 65 65
Minimum edge distance
for smin [mm] 290 235 220 180 135 135
Cracked concrete
smin [mm] 65 65 65 65 65 65
Minimum spacing
for cmin [mm] 105 90 85 75 65 65
cmin [mm] 65 65 65 65 65 65
Minimum edge distance
for smin [mm] 175 135 125 95 65 65
Anchor size HST4 , HST4-R M20
Effective anchorage depth hef [mm] 101 120 180
Drill hole cleaned yes no yes no yes no
Min. base material thickness hmin [mm] 160 175 180 195 270 270
Uncracked concrete
smin [mm] 90 90 90 90 90 90
Minimum spacing
for cmin [mm] 140 125 120 110 90 90
cmin [mm] 80 80 80 80 80 80
Minimum edge distance
for smin [mm] 260 220 205 170 140 140
Cracked concrete
smin [mm] 90 90 90 90 90 90
Minimum spacing
for cmin [mm] 100 90 85 80 80 80
cmin [mm] 80 80 80 80 80 80
Minimum edge distance
for smin [mm] 145 110 100 90 90 90
Update:Dec-24 13
Drilling and Installation equipment
For detailed setting information on installation see instructions (IFU) for use given with the product.
Rotary Hammers
TE 2 - TE 70
(Corded and Cordless)
Diamond Coring Machines DD EC-1, DD 30-W, DD 150-U
Torque Impact wrench with AT module
- SIW 6AT-22 & SI-AT-22
- SIW 4AT-22 & SI-AT-22
Hammer drill bit TE-CX, TE-YX, TE-C, TE-Y
Hollow drill bit TE-CD, TE-YD
Other tools
Diamond core bit TS, TL, SPX-T, SPX-L
Setting Tool HS-SC
Blow out pump