LITHIUM BATTERY
Primary lithium batteries
ER34615
3.6V Primary lithium-thionyl chloride
(Li-SOCl 2 ) Energy type
D-size bobbin cell For high drain/high pulses
applications requesting superior
voltage response in -55 ~+85
environments.
Cell size references ( UM1 - R20 - D )
Alternative models LS33600/LS33600C/LS33600LM/TL4930/SB-D01/SB-D02
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity 19Ah
(at 3 mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
Open circuit voltage (at +20 ) 3.66V
Nominal voltage (at 3mA +20 ) 3.6V
Pulse capability: Typically up to 400 mA (400 mA/0.1 second pulses ,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacitor may be recommended in severe conditions.
)
Max. Continuous current 200mA
Max. Pulse current 400mA
Storage (recommended) +30 max
(for more severe conditions)
Operating temperature range -55 / +85
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses)
Physical characteristics
Diameter (max) 34mm(1.41 in)
Height (max) 61.5mm(2.44 in)
Typical weight 106g(3.47 oz)
Available termination suffix radial tabs, radial pins, axial leads, flying leads
LITHIUM BATTERY
Characteristic curves
Discharge performance 25
3.5
V
ER34615 3.0
Voltage
4.0
26 0.2 3.5
3.0
1 0.05
12 0.1 2.5 2.5
2.0
0 1 2 3 4 5 6 7 8 9 10
Hours
2.0
(+) 13.5 33 56 330 1.1k
200mA 100mA 60mA 10mA 3mA
18k
0.2mA
4Ah 9Ah 10Ah 16Ah 19Ah 18Ah
1.5
1.0 2 3 4 5
0.1 1 10 10 10 10 10
61.5Max
Hours
0.4
18 0.2 Unit:mm Capacity VS Current
34.2 0.2 20
O
18 20 C
O
55 C
16
Capacity Ah
Key features 14
High and stable operating voltage 12
Superior drain capability O
Low self-discharge rate 10 72 C
(less than 1% after 1year of storage 8 0C
O
at +20 ) -30 C
O
6
Optional stainless steel container for
low magnetic and nickle plated steel 4
container for more safe design 2
Hermetic glass-to-metal sealing
0
Notch technology for safety vent is 0.1 1 10 100 1000
recommended Current mA
Non-flammable electrolyte
Main applications
Radiocommunication and other
military applications
Alarms and security systems
Beacons and emergency location
Voltage VS Temperature
transmitters
GPS 3.8
Metering systems
Sonobuoys
LED lighting applications 3.6
0.2mA
Others
Storage 3.4
V
1mA
The storage area should be clean,
Voltage
cool (not exceeding +30 ), dry 3.2
and ventilated. 10mA
Warning 3.0 35mA
Do not use if the battery casing was
mangled.
Please discharge the battery few 2.8
-60 -40 -20 0 20 40 60 80
minutes with 100mA,if the battery
voltage is lower than your need or consult ABLE. Temperature
Don t use different models of battery
in series.
Soldering the tag should be finished
in few seconds.
Do not try to recharge.