0% found this document useful (0 votes)
28 views1 page

130-Dwg-Civ-311.017-A Box Culvert Reinforcement Detail 3-1

The document outlines specifications for concrete structures, including concrete quality with specified compressive strengths and requirements for soil filling materials. It references additional drawings for bar splices, development lengths, and general civil notes. The document is related to the design and reinforcement details for box culverts in a specific project.

Uploaded by

Gaming Ryan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views1 page

130-Dwg-Civ-311.017-A Box Culvert Reinforcement Detail 3-1

The document outlines specifications for concrete structures, including concrete quality with specified compressive strengths and requirements for soil filling materials. It references additional drawings for bar splices, development lengths, and general civil notes. The document is related to the design and reinforcement details for box culverts in a specific project.

Uploaded by

Gaming Ryan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

1. ALL DIMENSION IN MILLIMETERS.


2. ELEVATION IN METERS.
3. CONCRETE QUALITY
- FOR CONCRETE STRUCTURE fc' = 30 MPa at 28 DAYS
- FOR LEAN CONCRETE fc' = 15 MPa at 28 DAYS
4. BAR SPLICES, DEVELOPMENT LENGTH AND OTHER GENERAL NOTED REFER TO DRAWING
NO. 130-DWG-CIV-311.003
5. SOIL FILLING AND BACK FILLING MATERIAL SHALL BE NON EXPANSIVE SOIL AND OTHER
CIVIL GENERAL NOTES REFER TO DRAWING NO. 130-DWG-CIV-311.900
t B/3 B/3 t B/3 B/3
(TYP.) (TYP.) (TYP.) (TYP.)
t/3 @t/3 MAX. t/2 t/3 @t/3 MAX.
(TYP.) (TYP.)
(TYP.)
50

Ld Ld
(TYP.) 200 (TYP.) 200 200
(TYP.)

(TYP.)
200

200
REBAR - A (TYP.) (TYP.) (TYP.) (TYP.)

(TYP.)

(TYP.)
H/3

H/3
TIES (TYP.)

(TYP.)

(TYP.)
Ld

Ld
TIES (TYP.)

REBAR - D (TYP.) REBAR - D (TYP.)

H
REBAR - B (TYP.) REBAR - C (TYP.)

REBAR - C (TYP.) REBAR - C (TYP.) REBAR - B (TYP.)

REBAR - D (TYP.) REBAR - D (TYP.)

D10-200 (TYP.) REBAR - C (TYP.) D10-200 (TYP.) REBAR - C (TYP.)

3-D10 (TYP.) 3-D10 (TYP.)

REBAR - A (TYP.) REBAR - B (TYP.) REBAR - B (TYP.) REBAR - A (TYP.)


LEAN CONCRETE 50mm REBAR - A (TYP.) LEAN CONCRETE 50mm
B B
COMPACTED SUB-GRADE COMPACTED SUB-GRADE
WITH MIN. DEGREE OF WITH MIN. DEGREE OF
COMPACTION TO REFER TO COMPACTION TO REFER TO
SINGLE BOX CULVERT CIVIL SPECIFICATION CIVIL SPECIFICATION
NTS MULTI BOX CULVERT
NTS

FOR APPROVAL
EPC: DESIGN CONSULTANT:
NUSARAYA PROJECT
RA Issued For Approval 25-01-2024 130 HAULING ROAD CH 80+225 - CH 126+405.71
Dadang S 25-01-2024
HAULING ROAD DESIGN
Jeff T 25-01-2024
Sheila MS 25-01-2024
BOX CULVERT REINFORCEMENT DETAILS
M Sofan 25-01-2024
©
A1 1
Alfin MFS 25-01-2024
130-DWG-HYD-361.017
Bernardus YD 25-01-2024 A

File name: C:\Users\saepudin.saepudin\OneDrive - Aurecon Group\04 DRAFTING\DRAINAGE\CAD\130-DWG-HYD-361.017-A BOX CULVERT REINFORCEMENT DETAIL

You might also like