manual_LSF1000-1(EN)_orion
manual_LSF1000-1(EN)_orion
Photo MSF850
Safety Precautions
Before operating this unit, be sure to read through the Essential Safety
Precautions presented in this manual.
Failure to observe precautions may result in injury or property damage. Essential safety
precautions are categorized as WARNINGS or CAUTIONS. The meaning of each
category is as follows:
Failure to observe the instructions contained in a
WARNINGS WARNING may result in death or severe injury.
Failure to observe the instructions contained in a
CAUTIONS CAUTION may result in injury or physical damage.
Failure to observe even CAUTIONS can have severe consequences! Please read through
this information carefully and handle this unit accordingly.
After reading through this manual, store it near the filter so that the operator can refer to it
as necessary.
If you transfer this unit to another user, be sure to include this manual together with the
unit. Place the manual at a prominent location on the unit so that the new user is sure to
notice it.
Safety Symbols
The symbol alerts you to actions you must take or precautions you must
observe. The drawing within the triangle indicates the action or precaution. (The
indication at left means that you should be careful of blowing off.)
The symbol indicates an action that you are required to carry out. Again, the
drawing in the circle illustrates the action.
Contents
Operational Notes……………………………………………….6
1
Essential Safety Precautions
Usage Precautions
WARNINGS
Failure to observe the instructions contained in a WARNING may result in death or
severe injury.
Purge compressed air from the body before cleaning, maintenance or
inspection.
Compressed air, if left, will blow off and may lead to injury.
CAUTIONS
Failure to observe the instructions contained in a CAUTION may result in injury or
physical damage.
Do not feed incorrect fluid into the unit.
This filter is designed to operate on compressed air. Input of a different type
of fluid may damage the unit and may lead to injury or water leakage (drain
circuit).
2
Warning Label on Product
Warning Label on Product
3
To Maintain Efficient and Trouble-Free Performance
CAUTION
1. This filter is designed to operate on compressed air. Input of a different type of fluid
may damage the unit and may lead to injury or water leakage (drain circuit).
2. Be sure that operating conditions remain within the specified range while the unit is
running. Operation outside of specified limits may result in unit failure.
Super Line Filter LSF
Super Mist Filter MSF 75B 400-1
Model 150B 200B 250B 404 500
Super Drain Filter (DSF)
Super ACF Filter KSF 400
Air Outlet / Inlet Conn.Port Rc3/8 Rc3/4 Rc1 Rc1 1/2
Air processing capacity m3/min 0.35 1.2 1.8 2.7 3.9 5.2
Housing
Specification plate
Body
Air inlet Air outlet
Band cover
Band
Specification plate
Element life indicator
Housing
Ball valve
Auto drain trap
Valve Operation
1. Slowly operate the valves for the air pipes before and after the filter. Rapid valve operation
may result in damage to the element or differential pressure gauge (option or accessory).
2. To purge air from the pipe and receiver tank, purge air from the outlet side so that air will
not flow backward through the filter. Air flowing backward through the filter may result in
damage to the filter element or differential pressure gauge. (option or accessory).
Operation
At the beginning of the operation, glass fibers adhered to the element surface often flow out
to the outlet side. keep air flowing for a while, and they will stop.
6
Periodic Inspection and Cleaning
Daily Inspection
WARNING
Purge compressed air from the body before cleaning, maintenance or inspection.
Compressed air, if left, will blow off and may lead to injury.
Always confirm the state of the auto drain unit before starting the flow of
compressed air. Failure to securely install the drain unit and fittings could result in
compressed air bursting out and injuries.
A Guide for Periodic Inspection and Cleaning
Inspection of auto drain trap (LSF, MSF, DSF) Daily
Disassembly and cleaning of auto drain trap (LSF, MSF,DSF) Weekly
The KSF filter and the LSF filter included with the QSQ do not include an auto drain trap.
Daily Inspection
Inspection of Auto Drain Trap (LSF,MSF,DSF)
Visually check the auto drain trap every day.
Check for air leakage.
Check if the trap is operating normally (water is discharged periodically).
●How Auto Drain Trap Works
When a drain is collected in the Bowl and reaches a certain level, it will be
automatically discharged. When the operating pressure drops below 0.1Mpa , all the
drain left in the Bowl will automatically discharged.
IMPORTANT
If the auto drain trap does not function properly, oil and water mist can enter the
compressed air and will flow through the air outlet side.
The KSF filter do not include an auto drain trap.
Check compressed
air leak
Does drain
Drain coming
Come out ?
out?
7
Periodic Inspection and Cleaning
Weekly Inspection and Maintenance
Weekly Inspection and Maintenance
Decomposition and Washing of Auto Drain Trap Internal Built in
Type(NH-503MR). (LSF MSF DSF75B 250B)
1. -Name of part
O - ring
Body
O - ring
Element
Fixed nut
Housing
Spanner
Auto drain trap
O - ring
Fixed nut
Wash with the neutral detergent.
8
Periodic Inspection and Cleaning
Weekly Inspection and Maintenance
Disassembly and Cleaning of Auto Drain Trap FD2
After a long period of use, each part of the trap is contaminated and the unit may fail
to operate normally. Remove the unit and disassemble and clean the trap every week.
To facilitate re-assembly, carefully observe the condition and mounting directions of
the assembled parts before disassembly. See the figure below.
1. Name of Part
Body
Screen
O-ring
Bowl assembly
Bowl guard
9
Periodic Inspection and Cleaning
Weekly Inspection and Maintenan
2.Cleaning the unit
(1)Close the ball valve.
Drain cock
Loosen Tighten
(3) Press the bowl guard, turn 45°, and pull down to remove the bowl assembly. When
removing the bowl assembly, the screen may fall out, so be careful not to lose it.
Body
Latch
45
10
Periodic Inspection and Cleaning
Weekly Inspection and Maintenan
(4) Remove and clean the screen.
Screen
(5) Put water into the bowl and lightly shake it to
remove dirt from around the float.
IMPORTANT
WARNING
Follow the procedure listed below to reassemble the drain trap by conducting the reverse
of the procedure used in disassembly. Failure to reliably assemble the unit can result in
the bowl coming off and compressed air bursting out, which could lead to injuries.
45
“Click”
11
Periodic Inspection and Cleaning
Weekly Inspection and Maintenan
4.Assembly
(1) Replace the cleaned screen to its initial position,
line up the latch with the arrow, and turn until the latch falls into the detent, which should
result in a clear "Click" sound.
(2) Turn the drain cock to the right to close it.
The direction to turn the drain cock is when
looking down from the top of the auto drain
trap. Drain cock
(3) Be sure to open the ball valve after
reinstalling the bowl assembly.
Loosen Tighten
IMPORTANT
Close the drain cock by turning it to the right when installing or when performing
inspection and maintenance.Failure to close the cock will result in air leakage during
operation.
Operation in atmospheres containing the substances listed in the chart below or in direct
sunlight can result in breaking of the bowl.
Chemical Chemical
Primary Chemical Examples General Purpose Use Examples
Type Classification
Pickling solution, acidic
Inorganic Hydrogen chloride, sulfuric acid, hydrofluoric acid,
Acids degreasing solution, film
chemicals phosphoric acid, chromic acid, etc.
processing solutions, etc.
Aromatic Benzene, toluene, xylene, ethyl benzene, styrene,
Solution containing paint thinner.
hydrocarbon etc.
Methyl alcohol, ethyl alcohol, cyclohexanol, benzyl Used as antifreeze.
Alcohol
alcohol Leakage detection fluid
Antiseptic solution, phenol resin
Phenol Carbolic acid, cresol, naphthol, etc.
raw materials
Organic
Acetone, methyl ethyl ketone, cyclohexanone,
chemicals Ketone
acetophenone, etc.
Formic acid, acetic acid, butyric acid, acrylic acid, Stain, aluminium coating agent
Carboxylic acid
oxalic acid, phthalic acid, etc. base, leakage detection fluid
Hydroxy acid Glycolic acid, lactic acid, malic acid, citric acid Additives for food, etc.
Methyl amine, dimethyl amine, ethylamine, aniline, Break fluid additive
Amine
acetanilide, etc. Anti-static additives, plastic dies
12
Replacing the Filter Element
Notes on Replacing the Filter Element / Replacement of the Filter Element
WARNING
Purge compressed air from the body before replacing the filter element.
Compressed air, if left, will blow off and may lead to injury.
4. If the differential pressure gauge (option or accessory) has been installed, replace the
filter element when the pointer indicates 0.045 to 0.07MPa even (DSF is 0.02MPa) before
a lapse of one year.
13
Replacing the Filter Element
Replacing the Element Life Indicator Batteries
Replacing the Filter Element
Replacing the Element Life Indicator Batteries
1. Loosen the screw of the indicator cover.
2. Slide the cover off.
Lighting check
3. Replace the batteries inside the element life Attaching screw switch
indicator.
Replacing the batteries allows the
element life indicator to be reset and start
to count a time.
4. After replacing the batteries or when
Slide the cover off.
checking the operation, press the switch
inside the case to check the LED lamp lights.
IMPORTANT
Be sure to use AA size alkaline batteries LR-6 for the batteries. Use of any other
battery may result in malfunction or short life.
Place the positive and negative sides correctly.
Do not use a new battery and an old battery or another type of battery in the
indicator.
Immediately take out the batteries when exhausted.
14
Replacing the Filter Element
Replacing the Filter Element
2. Replacing the Filter Element.
(LSF MSF DSF75B 250B,KSF150B 250B,)
(1) Screw left and unfasten the filter element.
(2) Screw right and fix the new filter element.
Wing nut
Body
Housing
15
Replacing the Filter Element
Replacing the Filter Element
3. Replace the element.
(1) Pull the internal element downward.
(2) Mount the O ring on the head cover of a new element
and insert it into the body.
O ring
5. Set the band cover to the correct position, then tighten the fixing screw.
6. If a element life indicator has been installed, replace the batteries. (see page 14)
16
Consumables and Renewal Parts
Parts to Be Replaced Periodically
Parts to Be Replaced Periodically
When placing an order of parts, please instruct part name, part number, and quantity.
Because of improvement of the machine, part of the mechanism or specification of the
product may be changed without notice.
Filter Elements
Product Name Model Element Type Qty Used
LSF75B ELS75 1
LSF150B ELS150 1
LSF200B ELS200 1
LSF250B ELS250 1
LSF400-1 ELS400 1
LSF404 ELS400 1
LSF500 ELS500 1
Super Line Filter LSF700-1 ELS700 1
LSF850 ELS850 1
LSF1000-1 ELS1000 1
LSF1005 ELS1000 1
LSF1200 ELS1200 1
LSF1300-1 ELS1300 1
LSF1700 ELS1700 1
LSF2000-1 ELS2000 1
MSF75B EMS75 1
MSF150B EMS150 1
MSF200B EMS200 1
MSF250B EMS250 1
MSF400-1 EMS400 1
MSF404 EMS400 1
MSF500 EMS500 1
Super Mist Filter MSF700-1 EMS700 1
MSF850 EMS850 1
MSF1000-1 EMS1000 1
MSF1005 EMS1000 1
MSF1200 EMS1200 1
MSF1300-1 EMS1300 1
MSF1700 EMS1700 1
MSF2000-1 EMS2000 1
17
Consumables and Renewal Parts
Parts To Be Replaced Periodically
Parts To Be Replaced Periodically
When placing an order of parts, please instruct part name, part number, and quantity.
Because of improvement of the machine, part of the mechanism or specification of the
product may be changed without notice.
Filter Elements
Product Name Model Element Type Qty Used
KSF150B EKS150 1
KSF200B EKS200 1
KSF250B EKS250 1
KSF400 EKS400 1
KSF404 EKS400 1
KSF500 EKS500 1
KSF700 EKS700 1
Super ACF Filter
KSF850 EKS850 1
KSF1000 EKS1000 1
KSF1005 EKS1000 1
KSF1200 EKS1200 1
KSF1300 EKS1300 1
KSF1700 EKS1700 1
KSF2000 EKS2000 1
DSF75B EDS75 1
DSF150B EDS150 1
DSF200B EDS200 1
DSF250B EDS250 1
DSF400-1 EDS400 1
DSF404 EDS400 1
Super Drain Filter DSF500 EDS500 1
DSF700-1 EDS700 1
DSF850 EDS850 1
DSF1000-1 EDS1000 1
DSF1005 EDS1000 1
DSF1200 EDS1200 1
DSF1300-1 EDS1300 1
18
Consumables and Renewal Parts
Parts To Be Replaced Based on Inspection
Parts To Be Replaced Based on Inspection
Element Life Indicator Batteries
Part Name Pieces Part No.
Alkaline battery LR-6 2 17640000100
19
Installation Procedure
Contents
Installation .................................................................... 22
20
Essential Safety Precautions
Installation Precautions
WARNINGS
Failure to observe the instructions contained in a WARNING may result in death or
severe injury.
Be sure to install this unit in accordance with the instructions given in
this manual.
Improper installation may lead to water leakage (drain circuit) or accident.
CAUTIONS
Failure to observe the instructions contained in a CAUTION may result in injury or
physical damage.
Be sure that the installation site is sufficiently strong to bear the full
weight of this unit.
The filter must be installed so that it is perpendicular. Do not secure the filter
with the housing. Improper installation may lead to injury from water
leakage or from dropping of unit.
21
At the Installation Site
Initial Check before installation
Initial Check before installation
Upon receipt of the unit, check it carefully any damage scratches, dents, etc.
If you find out any problem, please contact to your dealer.
Spec Plate
Installation
Installation Site
WARNING
Installation should be carried out by your dealer or by a specialized installation
engineer.
Installing this unit on your own may result in water leakage or accident.
Installation Site
1. Use this product in a place where the input air temperature is 5 60 .
2. Use this product in a place where the ambient temperatures is 2 60
3. Do not install the product where any the following substances is contained in the
processing air or in ambient atmosphere:
Phosphate hydraulic oil
Organic solvent (aromatic or chlorinated hydrocarbon compound)
Benzene, toluene, phenol, trichloroethylene, gasoline, thinner, etc.
Sulfurous acid gas, chlorine gas, Freon gas
Acids -hydrochloric acid, sulfuric cid, acetic acid, benzoic acid, etc.
22
Installation
Installation Site
4. Do not install the product outdoors.
5. Do not install this product in a place subject to direct sunlight. Subjecting this
product to direct sunlight for a long period may lead to air leakage.
CAUTION
Install the product on a floor strong enough to withstand the weight of the product.
Improper installation will result in water leakage or injury due to overturn or drop.
IMPORTANT
Leave adequate space around the product to enable preventive maintenance and
disassembling the filter.
(1) The distance from the band cover end to any obstacle such as a wall should be
at least 250mm as shown below. (LSF MSF400-1 2000-1 KSF400 2000
DSF400-1 1300-1)
(2) By referring to the following table, secure a distance (L) between the pipe
connection and the floor as long as possible.
Dimension
Model
L( )
250mm LSF MSF DSF75B
300
LSF MSF KSF DSF150B
LSF MSF KSF DSF200B 370
LSF MSF KSF DSF250B 400
LSF MSF DSF400-1,404
550
KSF400,404
LSF MSF KSF DSF500 680
LSF MSF DSF700-1
710
KSF700
LSF MSFKSF DSF850 770
L LSF MSF DSF1000-1,1005
920
KSF1000,1005
Floor LSF MSF KSF DSF1200 1,060
LSF MSF DSF1300-1
1,080
KSF1300
LSF MSF KSF1700 1,180
LSF MSF2000-1 SF2000 1,400
23
Installation
Piping Work
Piping Work
Air Outlet Inlet Connection Pipe Diameter
Line(LSF)
Mist(MSF) 75B 400-1
Model 150B 200B 250B 404 500
Drain(DSF)
ACF (KSF) 400
Air Outlet/Inlet Conn.Port Rc3/8 Rc3/4 Rc1 Rc1 1/2
Major Differential Pressure High pressure side : Rp1/4
Rc1/4
Sizes Gauge Conn.Port Low pressure side : M5
Drain Port( ) Rc1/4
Line(LSF)
1700 2000-1
Mist(MSF) 700-1 1000-1 1300-1
Model 850 1005 1200
Drain(DSF)
ACF (KSF) 700 1000 1300 1700 2000
Air Outlet/Inlet Conn.Port Rc1 1/2 Rc2
Major Differential Pressure
High pressure side : Rp1/4 , Low pressure side : M5
Sizes Gauge Conn.Port
Drain Port( ) Rc1/4
KSF and LSF on the QSQ do not have drain port.
Example of Standard Piping (LSF, MSF, KSF)
24
Installation
Piping Work
Pipe Connection Procedures
1. Perform piping so that the air flows in the direction of
the "arrow"
Flow of air
2. Secure the product with mounting brackets if there will
be heavy loads on the product inlet or outlet piping.
3. In case air may flow backward through the filter after
the air compressor is shut off, install a “check valve”
on the outlet side of the filter.
4. Install a purge valve on the air filter outlet side pipe. It
is useful for releasing internal pressure.
5. When replacing the filter element, if the air cannot be stopped because of continuous
operation of the air compressor, it is recommended that a bypass circuit with the same
filter be installed.
6. If much rust in the pipe comes off or there is much entry of impurities because of the long
pipe from the air compressor to the air dryer, it is recommended that the LFH(Max.
Operating Pressure 1.57MPa) be installed before the air dryer.
7. Before performing flushing at the end of piping work, remove the differential pressure
gauge (option or accessory) and filter element. For removing the filter element, refer to
“Replacing of the Filter Element” on page 13.
8. If the ambient temperature could fall to 2℃ or lower, install a pipe heating cable on the
auto drain trap.
9. The super drain filter removes drains (water drops,etc.) and solid particles mixed in
compressed air. Install it as far as possible from the air compressor and right before the
pneumatic equipment to be used, and it will remove then effectively.
IMPORTANT
Running high temperature air through the Super Mist Filter (MSF) can lead to early
damage. To avoid this, always install an air dryer before the filter.
Air back-flow can damage the element. It can also lead to damage of the differential
pressure gauge. Therefore it is advisable to consider the entire air system and install
"check valves" accordingly.
25
Installation
Piping Work
10. If the drain pipe of the auto drain trap rises or is too long, a drain may not be discharged
because of back pressure produced.
Support or mounting
11. If tubing is to be connected to the auto drain trap piping, use nylon tubing with an inside
diameter of φ5.7 - φ6.0. In addition, tubing can also be installed on the drain cock
section. If making screw piping connections to the drain, use the included screw adapter.
After inserting the air tubing into the connection port, push up until the groove on the
sleeve is no longer visible.
sleeve groove
12. In situations like when the piping leads out of the right side and the filter faces the back
side, reinstall the filter as indicated below.
LSF MSF DSF75B 250B KSF150B 250B
① Attach the included sticker also on the front side.
LSF MSF DSF400-1 2000-1,KSF400 2000
Remove the band cover and small fixing screw securing the body, reverse it, and
reattach.
Remove the housing, turn 180°, and then reattach.
26
Installation
Piping Work
IMPORTANT
Much air flowing backward may result in damage to the filter element. The
differential pressure gauge option or accessory may also fail. Install a check valve
by considering the entire air system.
When connecting the pipe to the outlet or inlet, be sure to secure the filter connector
with the pipe wrench and then screw in the pipe. Turning the body by hand may lead
to damage or air leakage.
When a long pipe is connected to the machine, or when any force is added to the
end connection of the machine, support this machine evenly with the mounting
clamps [bracketes] as follows.
27
Installation
Installing the Accessories and Option
Installing the Accessories and Option
1. Installing the Differential pressure gauge [DG-50(A)].
Attach the Differential pressure gauge to the filter as shown below.
Elbow Air tube
Connector
Differential
pressure gauge Hexagonal part
Elbow
IMPORTANT
When installing the differential pressure gauge, do not install any valve between the
air filter body and the differential pressure gauge. Such installation may result in
one-sided pressure on either high or low pressure side and may lead to damage to
the differential pressure gauge.
When installing or remove the differential pressure gauge, fit the spanner over the
hexagonal part and then turn. Turning the differential pressure gauge body by hand
may result in damage to the gauge.
28
Installation
Installing the Accessories and Option
4. Installing the Auto drain trap [FD2].
Attach the auto drain trap to the filter as shown below.
29
memo
memo
memo
Product Warranty
This product shall be warranted as follows. For warranty repairs, please contact the dealer where the product was sold after
confirming the product model and serial number.
1. Warranty Period
(1) One year