0% found this document useful (0 votes)
34 views12 pages

HeatGreen Commercial Water Heater

The document discusses the environmental impact of refrigerants used in heat pumps, emphasizing the EU's F-gas Regulation aimed at reducing emissions and promoting climate-friendly gases like R290. It highlights the benefits of achieving BREEAM certification for buildings, which can enhance property values and environmental reputation. Additionally, it details the features of a heat pump equipped with a 4G DTU module for remote monitoring and management, enhancing operational efficiency and maintenance.

Uploaded by

Nathan J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views12 pages

HeatGreen Commercial Water Heater

The document discusses the environmental impact of refrigerants used in heat pumps, emphasizing the EU's F-gas Regulation aimed at reducing emissions and promoting climate-friendly gases like R290. It highlights the benefits of achieving BREEAM certification for buildings, which can enhance property values and environmental reputation. Additionally, it details the features of a heat pump equipped with a 4G DTU module for remote monitoring and management, enhancing operational efficiency and maintenance.

Uploaded by

Nathan J
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Operation Envelope

R290
Natural Refrigerant 80
OT/℃ 73 73
70
70
Refrigerants, essential for heat pump efficiency, pose environmental concerns due to their high
60
global warming potential (GWP). To mitigate these negative impacts, the EU's F-gas Regulation 60
mandates reduced emissions of these gases. The reinforced F-gases Regulation will prevent the
emission of around 300 million tonnes of CO2 equivalent by 2050. It requires that new heat 50
pumps use the most climate-friendly gases.
40
Moreover, BREEAM, a leading global environmental assessment for buildings, evaluates and
certifies a structure's green performance. Achieving its certification can elevate property values,
30
lease rates, and bolster a company's environmental image.

According to its scoring system, up to 2 credits can be gained in the "Impact of refrigerant" section 20
by using a refrigerant with a GWP under 10.
10 -25 -7 35 43
R290 Refrigerant, with its low carbon emissions and GWP, is deemed the industry's top choice. AT/℃
Its use aligns with carbon neutrality goals. 0
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50

Refrigerant R744 R1234yf R454C R454B R513A R32 R410A


Extended Application
Type Natural Natural HFO HFO HFO HFO HFO HFC

CF3CF= 21.5%R32+ 68.9%R134a+ 44%R134a+ CH2F2 50%R32+ Combination with gas boiler
Ingredient CO2 C3H8
CH2 78.5%R1234yf 31%R1235yf 56%R1236yf 50%R125

ODP 0 0 0 0 0 0 0 0
Radiator
GWP-AR4 1 3 4 148 467 631 675 2088

Boiling -62.89 -42 -29.49 -45.56 -50.49 -29.47 -51.65 -51.44


temperature(°C) Water fan coil

Critical
30.98 96.74 94.7 85.67 78.1 94.91 78.11 71.34
temperature(°C)
Underfloor heating
Safety category A1 A3 A2L A2L A2L A1 A2L A1
OT/℃
Temperature slip 0 0 0.16 3~4 1~1.1 0 0 0.1
30 35 40 45 50 55 60 65 73
Product Features
8P 15P / 25P / 50P
4G DTU
With a plug-and-play 4G DTU module, this heat pump can instantly communicate with a remote
monitoring center through a cloud server upon power-up. The web-based monitoring platform
allows project managers and technicians to oversee and manage the heat pump. PHNIX's DTU
cloud server, based in Europe, guarantees data transmission security and stability.

Daily
Management After-sales
Management
The 4G DTU module is low-power, easy
to configure, and auto-connects when
the heat pump is powered on. Utilizing DTU technology, project managers
can monitor the device's real-time status
The web monitoring platform permits and promptly receive fault alerts, ensuring
users to monitor heat pump statuses its stable operation.
online, groupthem, and set schedules
as needed. Users can also report encountered issues to
the monitoring center.
Additionally, the cloud server records
essential real-time data, including inlet Technical experts can perform fault analysis
and outlet water temperature, pressure, on the web monitoring platform and address
and flow rate, enabling project managers faults remotely to guarantee the heat pump's
to assess project performance. safe operation.

Value-added Services
DTU technology transmits operational data and status of the heat pump to the monitoring center
for statistical analysis, enabling project managers to optimize unit operation and enhance project
energy efficiency. It also facilitates remote system upgrades, resulting in significant cost savings on
maintenance.
Centralize Commercial Projects step by step 1 Central Display manages Max. 16 Units
SG Ready Hybrid Function

The above information and data are for reference purposes only.
PHNIX reserves the right to modify and adjust the content at any time without prior notice and retains the final interpretation rights for such information and data.
Applications
Specifications
HeatGreen Models / PASRW080SB-BP-PS-D PASRW150S-BP-PS-D PASRW250S-BP-PS-D PASRW500S-BP-PS-D
Heating Condition -Ambient Temp.(DB/WB): 7/ 6°C, Water inlet / outlet 30 / 35°C
Heating Capacity Range kW 8.18-28.0 13.63-50.00 20.45-75.00 21.00-150.0
Heating Power Input Range kW 2.29-8.27 4.36-16.00 6.54-24.00 13.00-48.00
COP W/W 3.29-4.69 3.12-4.62 3.12-4.62 3.12-4.62
CURRENT INPUT Range A 3.74-13.72 6.97-25.6 10.45-38.4 20.90-76.80
Heating Condition -Ambient Temp.(DB/WB): 2 / 1°C, Water inlet / outlet 30 / 35°C
Heating Capacity Range kW 6.27-23.00 11.07-40.60 16.16-59.27 32.32-118.54
Heating Power Input Range kW 2.14-7.84 3.77-13.83 5.50-20.19 11.00-40.38
COP W/W 2.94-3.51 2.94-3.51 2.94-3.51 2.94-3.51
CURRENT INPUT Range A 3.26-11.97 5.76-21.13 8.40-30.84 16.80-61.68
Heating Condition -Ambient Temp.(DB/WB): -7 / -°C, Water inlet / outlet 50 / 55°C
Heating Capacity Range kW 4.87-17.00 8.47-30.00 12.03-43.00 24.06-86.00
Heating Power Input Range kW 2.96-8.88 5.34-16.29 7.63-22.88 15.25-45.76
COP W/W 1.83-2.85 1.83-2.79 1.83-2.79 1.83-2.79
CURRENT INPUT Range A 4.52-13.57 8.01-23.95 11.68-35.04 23.36-70.08
Cooling Condition -Ambient Temp.(DB/WB): 35 / 24°C, Water inlet / outlet 12 / 7°C
Heating Capacity Range kW 5.03-18.5 9.27-34.00 14.10-50.00 28.20-100.00
Heating Power Input Range kW 2.49-9.24 3.91-14.35 5.95-21.82 11.90-43.64
COP W/W 1.99-3.39 1.95-3.45 1.95-3.45 1.95-3.45
CURRENT INPUT Range A 4.136-13.65 6.26-22.96 9.51-34.89 19.02-69.78
Heating Condition -Ambient Temp.(DB/WB): 20 / 15°C, Water inlet / outlet 15 / 55°C
Heating Capacity Range kW 8.90-38.00 16.36-70.00 23.22-100.00 46.44-200.00
Heating Power Input Range kW 2.75-10.50 5.29-19.40 7.51-27.54 15.02-55.08
COP W/W 3.31-4.58 3.21-4.65 3.21-4.65 3.21-4.65
CURRENT INPUT Range A 4.60-17.00 8.22-30.14 1.67-42.80 23.34-85.60
Max.Hot Water Capacity L/h 817 1505 2150 4300
ERP Level (35℃) / A+++
ERP Level (55℃) / A++
SCOP (65℃) / 2.80 2.75 2.71 2.65
Max.Power Input kW 12.6 24.0 36.0 72.0
Max.Current Input A 17 30 45 90
Power Supply V/Ph/Hz 380-415V/3N~50-60Hz
Refrigerant / R290
Sound Pressure(1m) dB(A) 53 62 68 72
Sound Power Level EN12102 dB(A) 68 77 83 87
Operating Ambient Temperature ℃ -25~43
Max.Outlet Water Temperature ℃ 73
Fan Motor Quantity / 2 1 2 2
Fan Motor Type / DC Fan Motor
Warter Connection inch G1” G1.5” DN50 DN80
Water Pressuremax kPa 65 80 100 100
Refrigerant Charge g 1800 1500*2 2400*2 2400*4
CO2 Equivalent Ton 0.0055 0.0092 0.01472 0.02944
Rated Water Flow m3/h 3.4 5.85 8.5 17
Rated Water Pressure Drop kpa 65 80 100 100
Circulation Pump Water Head m 12.5 / / /
Net Weight kg 202 490 733 1126
Gross Weight kg 223 560 833 1173
Unit Dimension (L/W/H) mm 1350/540/1330 1195/980/1900 1965/1170/2070 2370×1270×2470
Shipping Dimension (L/W/H) mm 1370/560/1350 1320/1100/2150 1995×1200×2100 2400×1300×2500
Loading Quantity in 40HQ pcs 28 18 11 8

The data above is for reference only. For more specific data, please refer to the nameplate on the unit.