AGM Standby Use Battery > NM Series
NM12-150
12V150Ah / 10hr rate
Introduction Battery Picture & Terminal Layout
Genergy NM (33Ah-250Ah) series is designed for standby
use with 10-year design life in float service. The series battery
is featured of high consistency, excellent performance and
reliable standby service life. It is widely applied in float service,
UPS/EPS, medical equipment, telecom, photovoltaic, control
system and security system.
Battery Features
○ Increase durability and deep cycle ability for heavy
demand applications
○ Low self-discharge
○ Fully tank formed plates
○ Low impurity electrolyte
○ Spill proof / leak proof Terminal Type: T13
○ Multi-position usage
○ ABS case and cover VO upon request
○ Very high purity lead
Electrical Specification
Design floating Life @ 25° C (77° F) …………………… 10 years
Nominal Capacity @ 25° C /77° F
20 hour rate 7.72A to 1.75Vpc …………………… 154.4 Ah
10 hour rate 15.06A to 1.75Vpc …………………… 150.6 Ah
Internal Resistance
(Fully charged battery @ 25°C /77°F ) …………. 4mΩ Dimension & Weight
Max. Discharge Current @ 25°C /77°F ………….. 1500 A (5S) Dimension (± 2mm) Weight
Charge Methods: Constant voltage charge @ 25° C /77° F Length Width Height Total Height (± 2%)
Cycle Use ……………………………………… 14.7 ~ 14.9V 485 mm 170 mm 240 mm 240 mm 41.7 kg
Max. Current ………………………………….. 40 A 19.1 inch 6.7 inch 9.4 inch 9.4 inch 91.9 lbs
Standby Use ………………………………….. 13.6 - 13.8V
Operating Temperature Range …………………… -30 ~ 50° C Typical Applications
Notes: battery voltage must be adjusted according to temperature. ○ Telecommunications ○ Power Utility ○ Data Center ○ UPS & EPS
Please refer to our recommendation.
Self-Discharge Certificates
3% of capacity declined per month @ 25° C (77° F).
Constant Current Discharge (Amperes @ 25°C /77°F)
V/cell 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1hr 2hr 3hr 4hr 5hr 10hr 20hr
1.60 326.8 249.5 215.5 181.6 153.7 146.8 136.9 127.8 119.5 112.3 110.3 59.78 42.54 35.33 28.88 15.43 7.79
1.65 310.4 236.9 205.8 174.6 149.6 142.9 133.5 124.9 117.1 110.4 108.8 58.62 41.72 34.59 28.22 15.36 7.79
1.70 297.5 227.1 197.6 168.2 144.8 138.2 129.1 120.9 113.4 107.1 105.8 56.64 40.76 33.77 27.55 15.21 7.79
1.75 283.8 216.6 188.8 161.0 139.3 132.9 124.5 116.8 110.0 104.3 103.5 55.08 39.87 33.03 26.96 15.06 7.72
1.80 269.2 205.5 179.5 153.6 133.8 127.6 119.7 112.5 106.1 100.9 100.5 53.10 38.91 32.22 26.29 14.67 7.65
Constant Power Discharge (Watts/cell @ 25°C /77°F)
V/cell 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1hr 2hr 3hr 4hr 5hr 10hr 20hr
1.60 567.6 433.3 381.3 329.3 287.1 274.9 255.3 237.4 220.7 206.6 201.0 110.5 80.42 66.73 54.95 30.79 16.24
1.65 547.5 417.9 368.5 319.2 279.5 267.6 248.8 231.5 215.6 202.2 197.3 108.3 79.68 65.99 54.21 30.49 16.24
1.70 526.4 401.8 354.9 307.9 270.6 259.1 241.3 224.9 210.0 197.6 193.5 105.7 78.20 64.84 53.40 29.90 16.03
1.75 503.5 384.4 340.0 295.6 261.0 249.9 233.0 217.6 203.6 192.3 189.0 102.3 75.97 63.25 52.43 29.68 15.73
1.80 478.8 365.5 324.0 282.5 250.7 239.9 224.1 209.6 196.6 186.2 183.8 98.7 73.97 61.65 51.25 29.38 15.59
Subject to revision without notice. Please contact our sales representatives for latest version.
Web: www.genergybattery.com 丨 Email: [email protected] Page 1 of 2
AGM Standby Use Battery > NM Series
NM12-150
12V150Ah / 10hr rate
Graphs
Charged
Charge Characteristic Curve Discharge Characteristic (25° C)
Current
Volume
Volt age
(V /cell)
Constant Voltage Charging Characteristic (25° C)
(%) (CA) (V/cell) 2.17
120
2.00
100 0.10 2.50 CHARGED VOLUM E
Battery Vol tag e(V )
1.83
80 0.08 2.33
CHARGE VOLTAGE 0 .1 7 5 C 0 .1 C 0 .0 5 C
1.67 0 .2 5 C
60 0.06 2.17 2C 1 C 0 .6 5 C
1.50
40 0.04 2.00
1.33
20 0.02 1.83
CHARGING CURRENT 00 1 2 3 5 10 20 30 60 2 3 5 10 20 30
0 0 min h
0 2 4 6 8 12 16 20 24 28 32
Charging Time (hours) Discharge Time
Temperature Effects On Float Life Cycle Service Life V.S. Depth Of Discharge
100% 100
Depth of discharge (% )
75%
80
33%
Desig n Li fe
60
40
7%
20
3%
0 20 30 40 50 60 0 200 400 600 800 1000 1200
Temperature (° C ) Note:If float charge tempreture is adjusted to our Number of Cycles (cycles)
recommendation, then maximum wil l be achieved.
Charging Voltage V.S. Temperature Self-Discharge Characteristic
(V/cell)
100
2.6 80 1 0° C
Chargi ng Vol tag e (V)
2.5
Capaci ty (%)
60 2 0° C
2.4
4 0° C 3 0° C
40
2.3
Cycle Use
20
2.2
Standby Use
-10 0 10 20 30 40 50 60 0 3 6 9 12 15
Ambient Temperature (° C ) Storage Time: months
Life Characteristics Of Standby Use Temperature Effects On Capacity
120 120
100 100 0.05C A
Avai labl e Cap aci ty (% )
80 0.1C A
80
Capacity (%)
60 1C A
60 Te stin g co n d itio n s: Flo a tin g vo lta g e : 2 .2 7 to 2 .3 V / ce ll
Am b ie n t te m p e r a tu r e : 2 5° C ( 7 7° F)
2C A
40
40
20
20
0
- 20 - 10 0 10 20 30 40
0 4 7 10
Life ( year) Ambient Tempreture ( ° C)
Subject to revision without notice. Please contact our sales representatives for latest version.
Web: www.genergybattery.com 丨 Email: [email protected] Page 2 of 2