The document provides a detailed datasheet for the ATV61 Plus variable speed drive, including specifications such as power rating (400 kW), supply voltage (690 V), and protection rating (IP23). It outlines the product's features, applications, and compliance with various standards, as well as information on its environmental impact and warranty. The drive is set to be discontinued on September 6, 2024, with end-of-service planned for December 31, 2028.

Uploaded by

Sergey Zhukov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views10 pages

Schneider Electric Altivar-61-Plus ATV61EXC2C40Y

The document provides a detailed datasheet for the ATV61 Plus variable speed drive, including specifications such as power rating (400 kW), supply voltage (690 V), and protection rating (IP23). It outlines the product's features, applications, and compliance with various standards, as well as information on its environmental impact and warranty. The drive is set to be discontinued on September 6, 2024, with end-of-service planned for December 31, 2028.

Uploaded by

Sergey Zhukov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Product datasheet

Specifications

enclosed variable speed drive


ATV61 Plus - 400 kW - 690V - IP23
ATV61EXC2C40Y

notification_critical_stroke Discontinued on: 6 Sept 2024

notification_critical_stroke To be end-of-service on: 31 Dec 2028

notification_critical_stroke Discontinued - Service only

Main
Range of product Altivar 61 Plus

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Variable speed drive

Device short name ATV61

Product destination Asynchronous motors


Synchronous motors

Product specific application Pumping and ventilation machine

Assembly style In floor-standing enclosure compact version

product composition ATV61HC40Y standard drive IP00


A switch and fast-acting fuses
An IP65 remote mounting kit for graphic display terminal
A wired ready-assembled Sarel Spacial 6000 enclosure
A line choke
Terminals/bars for motor connection

EMC filter Integrated

Network number of phases 3 phases

rated supply voltage 690 V +/- 10 %

Supply voltage limits 621…759 V

Supply frequency 50...60 Hz - 5...5 %

Network frequency limits 47.5…63 Hz

Motor power kW 400 kW, 3 phases at 690 V

Line current 394 A at 690 V3 phases / 400 kW

IP degree of protection IP23

Complementary
Apparent power 471 kVA for 690 V, 3 phases 400 kW

Prospective line Isc 100 kA with external fuses

Continuous output current 420 A, 2.5 kHz at 690 V 3 phases

Maximum transient current 504 A for 60 s, 3 phases

Speed drive output frequency 0.1…500 Hz

Nominal switching frequency 2.5 kHz

Switching frequency 2.5...4.9 kHz with derating factor


2...4.9 kHz adjustable

Speed range 1…100 in open-loop mode, without speed feedback

Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback

8 Jan 2025 1
Torque accuracy +/- 15 % in open-loop mode, without speed feedback

Transient overtorque 120 % of nominal motor torque for 60 s


135 % of nominal motor torque for 2 s

Braking torque <= 125 % with braking resistor


30 % without braking resistor

Asynchronous motor control Energy saving ratio


profile Flux vector control without sensor, standard
Voltage/frequency ratio (2 or 5 points)

Synchronous motor control profile Vector control without sensor, standard

Regulation loop Adjustable PI regulator

Motor slip compensation Not available in voltage/frequency ratio (2 or 5 points)


Can be suppressed
Automatic whatever the load
Adjustable

Overvoltage category Class 3 conforming to EN 50178

Local signalling LCD display unit for operation function, status and configuration - mounted in the
front door

Output voltage <= power supply voltage

Isolation Between power and control terminals

type of cable for external IEC cable at 40 °C, copper 70 °C / PVC


connection
Electrical connection Terminal - 2.5 mm² / AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B,
LI1...LI6, PWR)
Terminal M12 - 4 x 240 mm² (U/T1, V/T2, W/T3)
Terminal M12 - 3 x 185 mm² (L1/R, L2/S, L3/T)

Motor recommanded cable cross 2 (3 x 150) mm²


section
Short-circuit protection 630 A fuse protection type gI - power supply upstream

Supply External supply: 24 V (19…30 V)DC, <1 A, 30 W


Internal supply for reference potentiometer: 10 V (10…11 V)DC, <10 mA
Internal supply: 24 V (21…27 V)DC, <100 mA

Analogue input number 2

Analogue input type AI2 software-configurable voltage: 0...10 V DC, 24 V max, impedance: 30 kOhm,
sampling time: 1.5…2.5 ms, resolution: 11 bits
AI1-/Al1+ bipolar differential voltage: +/- 10 V DC, 24 V max, sampling time: 1.5…2.5
ms, resolution: 11 bits + sign
AI2 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm,
sampling time: 1.5…2.5 ms, resolution: 11 bits

Analogue output number 1

Analogue output type Software-configurable voltage: (AO1) 0...10 V DC - 470 Ohm - sampling time: 1.5…
2.5 ms - resolution: 10 bits
Software-configurable current: (AO1) 0...20 mA/4...20 mA - 500 Ohm - sampling
time: 1.5…2.5 ms - resolution: 10 bits

Discrete output number 2

Discrete output type Configurable relay logic: (R1A, R1B, R1C)NO/NC - 6.5...7.5 ms - 100000 cycles
Configurable relay logic: (R2A, R2B)NO - 6.5...7.5 ms - 100000 cycles

Minimum switching current 3 mA at 24 V DC (configurable relay logic)

Maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 for configurable relay logic
5 A at 30 V DC on resistive load - L/R = 0 ms for configurable relay logic
2 A at 250 V AC on inductive load - cos phi = 0.4 for configurable relay logic
2 A at 30 V DC on inductive load - L/R = 7 ms for configurable relay logic

Discrete input number 7

2 8 Jan 2025
Discrete input type Programmable (LI1...LI5) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5…
2.5 ms)
Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5…
2.5 ms)
Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhm

Discrete input logic Positive logic (source) (LI1...LI6), 0...5 V (state 0), 11...30 V (state 1)
Negative logic (sink) (LI1...LI6), 16...30 V (state 0), 0...10 V (state 1)
Positive logic (source) (PWR), 0...2 V (state 0), 17...30 V (state 1)

Acceleration and deceleration S, U or customized


ramps Linear adjustable separately from 0.01 to 9000 s

Braking to standstill By DC injection

Protection type Against exceeding limit speed: drive


Against input phase loss: drive
Break on the control circuit: drive
Input phase breaks: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Overvoltages on the DC bus: drive
Power removal: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Motor phase break: motor
Power removal: motor
Thermal protection: motor

Dielectric strength 3110 V DC between earth and power terminals


5345 V DC between control and power terminals

Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth

Frequency resolution Analog input: 0.024/50 Hz


Display unit: 0.1 Hz

Communication port protocol Modbus


CANopen

Connector type 1 RJ45 (on front face) for Modbus


1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen

Physical interface 2-wire RS 485 for Modbus

Transmission frame RTU for Modbus

Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
9600 bps, 19200 bps for Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen

Data format 8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal

Type of polarization No impedance for Modbus

Number of addresses 1…127 for CANopen


1…247 for Modbus

Method of access Slave CANopen

8 Jan 2025 3
Function available Safe standstill for power circuit
PTC relay for power circuit
Pt100 relay for power circuit
Insulation monitoring for power circuit
Design for IT networks for power circuit
External 230 V supply terminals for power circuit
Buffer voltage 24 V DC power supply for power circuit
Enclosure lighting for power circuit
Key switch (local/remote) for power circuit
Motor heating for power circuit
External motor fan for power circuit
Voltmeter for power circuit
Door handle for main switch for power circuit
Line contactor for power circuit
12-pulse supply for power circuit
Ammeter for power circuit
Enclosure heating for power circuit
Motor choke for power circuit
Cable entry via the top for power circuit
Enclosure plinth for power circuit
Braking unit for power circuit
Relay output C/O for control circuit
External 24 V DC supply terminals for power circuit
Control terminals for control circuit
Adaptor for 115 V logic inputs for control circuit
Isolated amplifier for control circuit

Option card Communication card for APOGEE FLN


Communication card for BACnet
Communication card for CC-Link
Communication card for DeviceNet
Communication card for EtherNet/IP
Communication card for Fipio
Communication card for Interbus-S
Communication card for LonWorks
Communication card for METASYS N2
Communication card for Modbus Plus
Communication card for Modbus TCP
Communication card for Modbus/Uni-Telway
Communication card for Profibus DP
Communication card for Profibus DP V1
Controller inside programmable card
Multi-pump card
Basic I/O extension card
Extended I/O extension card
Encoder interface cards

Operating position Vertical +/- 10 degree

Colour of enclosure Light grey (RAL 7035)

width 800 mm

Height 2162 mm

Depth 642 mm

Net weight 553 kg

Environment
Electromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to
IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11

Standards EN 61800-3 environments 1 category C3


EN 55011 class A group 2
EN 61800-3 environments 2 category C3
EN/IEC 61800-5-1
EN/IEC 61800-3

Product certifications GOST


ATEX

4 8 Jan 2025
Marking CE

Noise level 66 dB

Pollution degree 2 conforming to EN/IEC 61800-5-1

Vibration resistance 0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6


1.5 mm peak to peak (f= 3…10 Hz) conforming to EN/IEC 60068-2-6
3M3 conforming to EN/IEC 60721-3-3

Shock resistance 4 gn for 11 ms conforming to EN/IEC 60068-2-27


3M2 conforming to EN/IEC 60721-3-3

Environmental characteristic 3C2 without condensation conforming to IEC 60721-3-3


3S2 without condensation conforming to IEC 60721-3-3
3K3 without condensation conforming to IEC 60721-3-3

Relative humidity 0…95 %

Ambient air temperature for 0…40 °C (without derating)


operation 40…50 °C (with current derating of 1 % per °C)

Ambient air temperature for -25…70 °C


storage
Volume of cooling air 1200 m3/h

Operating altitude <= 1000 m without derating


1000...2260 m with current derating 1 % per 100 m

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 216.0 cm

Package 1 Width 66.0 cm

Package 1 Length 101.6 cm

Package 1 Weight 555.0 kg

Contractual warranty
Warranty 18 months

8 Jan 2025 5
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain
partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use
Longer, Use Again” campaign to extend product lifetimes and recyclability.

How this information helps you

Use Better

Materials and Substances

Packaging made with recycled


No
cardboard

Packaging without single use


No
plastic

Use Again

Repack and remanufacture

Take-back No

6 8 Jan 2025
Product datasheet ATV61EXC2C40Y

Dimensions Drawings

IP 23 Floor-Standing Enclosure Compact Version

Standard Compact Floor-Standing Enclosure

Standard Compact Floor-Standing Enclosure + Additional Floor-Standing Enclosures,


According to the Configuration

(1) Seal. For each floor-standing enclosure added, allow a 4 mm/0.15 in. space for the seal.

(2) Standard IP 23 compact version floor-standing enclosure.

NOTE: The position of the enclosures must be complied with during


installation. The number of additional enclosures can vary according to the
chosen configuration.

8 Jan 2025 7
Product datasheet ATV61EXC2C40Y

Options a a1 a2 a3 a4

With or without common options or options 816 mm/ 816 mm/


– – –
dependent on the drive rating 32.1 in. 32.1 in.

808 mm/ 408 mm/ 1220 mm/


Cable entry via the top option – –
31.8 in. 16 in. 48 in.

808 mm/ 408 mm/ 1220 mm/


Braking unit option – –
31.8 in. 16 in. 48 in.

808 mm/ 408 mm/ 400 mm/ 1624 mm/


Braking unit + cable entry via the top options –
31.8 in. 16 in. 15.7 in. 63.9 in.

(3) Except sinus filter option, which requires an additional enclosure. The sinus filter option is not compatible with
the cable entry via the top option.

(4) The cable entry via the top option is not compatible with the sinus filter option.

8 8 Jan 2025
Product datasheet ATV61EXC2C40Y

Connections and Schema

Floor-Standing Enclosure Compact Version

Wiring Diagram

A1 Drive

A2 Enclosure

F1 Fast-acting semi-conductor fuse

IL1 Line choke

Q1 Switch

(1) Fault relay contacts. For remote signalling of drive status.

8 Jan 2025 9
Product datasheet ATV61EXC2C40Y

Performance Curves

Floor-Standing Enclosure Compact Version

Derating Curves
The derating curves for the drive nominal current (In) are dependent on the temperature and switching frequency. For
intermediate temperatures, interpolate between 2 curves.

NOTE: The drive will reduce the switching frequency automatically in the
event of excessive temperature rise.

X Switching frequency (kHz)

NOTE: The temperatures shown correspond to the temperature of the air


entering the enclosure.

10 8 Jan 2025