0% found this document useful (0 votes)
59 views7 pages

PI1008 Flush Pressure Sensor Specs

The document provides detailed specifications for the PI1008 Flush Pressure Sensor with display, including its features, electrical data, application, and mechanical data. It highlights that the product should not be used for new projects due to the unavailability of adapters. The sensor is designed for the food and beverage industry, capable of measuring a range of pressures and temperatures, with various output options.

Uploaded by

wkt135
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views7 pages

PI1008 Flush Pressure Sensor Specs

The document provides detailed specifications for the PI1008 Flush Pressure Sensor with display, including its features, electrical data, application, and mechanical data. It highlights that the product should not be used for new projects due to the unavailability of adapters. The sensor is designed for the food and beverage industry, capable of measuring a range of pressures and temperatures, with various output options.

Uploaded by

wkt135
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

PI1008

Flush pressure sensor with display


PI-,25BRES30-MFRKG/US/ /P

Please do not use for new projects.


no more adapters available as accessories

1 alphanumeric display 4-digit


2 status LEDs
3 programming button
4 Aseptoflex - sealing contour
5 external thread Aseptoflex S30x2

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa -126...2550 mmWS
Process connection threaded connection S30x2 external thread Aseptoflex
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...150
Min. bursting pressure 30000 mbar 12044 inH2O 3000 kPa
Pressure rating 6000 mbar 2400 inH2O 600 kPa
Vacuum resistance -1000 mbar -0.1 MPa
Type of pressure relative pressure; vacuum
No dead space yes
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

Protection class III


Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20...30 DC
Current consumption [mA] 3.5...21.5
Power-on delay time [s] <1
3-wire
Operating voltage [V] 18...30 DC
Current consumption [mA] 5...45; (430 bei max. Laststrom)
Power-on delay time [s] < 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching [V]
2
output DC
Permanent current rating of [mA]
100
switching output DC
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Measuring/setting range
Measuring range -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa -126...2550 mmWS
Set point SP -12...250 mbar -4.8...100.4 inH2O -1.2...25 kPa -122...2549 mmWS
Reset point rP -12.4...249.6 mbar -5...100.2 inH2O -1.24...24.96 kPa -126...2545 mmWS
Analogue start point -12.4...199.4 mbar -5...80.1 inH2O -1.24...19.94 kPa -126...2033 mmWS
Analogue end point 38.2...250 mbar 15.3...100.4 inH2O 3.82...25 kPa 390...2549 mmWS
Min. difference between SP 0.5 mbar 0.2 inH2O 0.05 kPa 5 mmWS
and rP
In steps of 0.1 mbar 0.1 inH2O 0.01 kPa 1 mmWS

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

Factory setting SP1 =62.5 mbar rP1 = 57.5 mbar


SP2 = 187.5 mbar rP2 = 182.5 mbar
ASP = 0.00 mbar AEP = 250 mbar
dAP = 2.00 s dAA =2.00 s
Temperature monitoring
Measuring range -25...150 °C -13...302 °F
Accuracy / deviations
Switch point accuracy
< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and
[% of the span] span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Hysteresis deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Long-term stability
< ± 0,1; (Turn down 1:1; per year)
[% of the span]
Total deviation over Temperature range total deviation
temperature range -25...15 °C Characteristics deviation ± 0,1 % of the
span / 10 K
15...80 °C Characteristics deviation
80...150 °C Characteristics deviation ± 0,15 % of the
span / 10 K
Notes on the accuracy /
for further details see section Diagrams and graphs
deviation
Temperature monitoring
Accuracy [K] ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability [K] ± 0,2
Resolution [K] 0.2
Response times
Damping process value dAP [s] 0...99.99
Damping for the analogue [s]
0...99.99
output dAA
2-wire
Step response time analogue [ms]
30
output
3-wire
Min. response time of [ms]
3
switching output (dAP)
Step response time analogue [ms]
7
output
Temperature monitoring
Dynamic response T05 / T09 [s] < 35 / < 135; (DIN EN 60751 water ; > 0,9 m/s)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

IO-Link revision 1.1


SDCI standard IEC 61131-9
Profiles Function class Designation
0x4000 Identification and Diagnosis
0x800A Measurement Data Channel (standard
resolution)
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5.6
IO-Link resolution pressure [mbar] 0.01
IO-Link resolution [K]
0.2
temperature
IO-Link process data function bit length
(cyclical) pressure 32
temperature 32
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours
counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs Type of operation DeviceID
default 1152
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC DIN EN 61326-1
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 201
Note on approval factory certificate available as download at www.factory-certificate.ifm
UL approval UL Approval no. J048
File number UL E174189
Mechanical data
Weight [g] 347.9
Housing cylindrical
Dimensions [mm] Ø 50 / L = 106.4
Materials stainless steel (316L/1.4404); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (316L/1.4435);
surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Tightening torque [Nm] 25
Process connection threaded connection S30x2 external thread Aseptoflex

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

Displays / operating elements


Display Display unit LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit mbar; kPa; inH2O; mmWS
Remarks
Notes Please do not use for new projects.; no more adapters available as accessories
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

Connection

1 connection for 2-wire operation


2 connection for 3-wire operation
OUT1 switching output / IO-Link
OUT2 switching output / analogue output
3 connection for IO-Link parameter setting (P = communication via IO-Link)
colours to DIN EN 60947-5-2
Core colours
BK = black
BN = brown
BU = blue
WH = white

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P

Diagrams and graphs


ambient temperature influence on
the accuracy

X temperature
Y total deviation

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —