PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Please do not use for new projects.
no more adapters available as accessories
1 alphanumeric display 4-digit
2 status LEDs
3 programming button
4 Aseptoflex - sealing contour
5 external thread Aseptoflex S30x2
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa -126...2550 mmWS
Process connection threaded connection S30x2 external thread Aseptoflex
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...150
Min. bursting pressure 30000 mbar 12044 inH2O 3000 kPa
Pressure rating 6000 mbar 2400 inH2O 600 kPa
Vacuum resistance -1000 mbar -0.1 MPa
Type of pressure relative pressure; vacuum
No dead space yes
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20...30 DC
Current consumption [mA] 3.5...21.5
Power-on delay time [s] <1
3-wire
Operating voltage [V] 18...30 DC
Current consumption [mA] 5...45; (430 bei max. Laststrom)
Power-on delay time [s] < 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit
pulsed
protection
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching [V]
2
output DC
Permanent current rating of [mA]
100
switching output DC
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Measuring/setting range
Measuring range -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa -126...2550 mmWS
Set point SP -12...250 mbar -4.8...100.4 inH2O -1.2...25 kPa -122...2549 mmWS
Reset point rP -12.4...249.6 mbar -5...100.2 inH2O -1.24...24.96 kPa -126...2545 mmWS
Analogue start point -12.4...199.4 mbar -5...80.1 inH2O -1.24...19.94 kPa -126...2033 mmWS
Analogue end point 38.2...250 mbar 15.3...100.4 inH2O 3.82...25 kPa 390...2549 mmWS
Min. difference between SP 0.5 mbar 0.2 inH2O 0.05 kPa 5 mmWS
and rP
In steps of 0.1 mbar 0.1 inH2O 0.01 kPa 1 mmWS
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Factory setting SP1 =62.5 mbar rP1 = 57.5 mbar
SP2 = 187.5 mbar rP2 = 182.5 mbar
ASP = 0.00 mbar AEP = 250 mbar
dAP = 2.00 s dAA =2.00 s
Temperature monitoring
Measuring range -25...150 °C -13...302 °F
Accuracy / deviations
Switch point accuracy
< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
[% of the span]
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and
[% of the span] span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Hysteresis deviation
< ± 0,15; (Turn down 1:1)
[% of the span]
Long-term stability
< ± 0,1; (Turn down 1:1; per year)
[% of the span]
Total deviation over Temperature range total deviation
temperature range -25...15 °C Characteristics deviation ± 0,1 % of the
span / 10 K
15...80 °C Characteristics deviation
80...150 °C Characteristics deviation ± 0,15 % of the
span / 10 K
Notes on the accuracy /
for further details see section Diagrams and graphs
deviation
Temperature monitoring
Accuracy [K] ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability [K] ± 0,2
Resolution [K] 0.2
Response times
Damping process value dAP [s] 0...99.99
Damping for the analogue [s]
0...99.99
output dAA
2-wire
Step response time analogue [ms]
30
output
3-wire
Min. response time of [ms]
3
switching output (dAP)
Step response time analogue [ms]
7
output
Temperature monitoring
Dynamic response T05 / T09 [s] < 35 / < 135; (DIN EN 60751 water ; > 0,9 m/s)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Function class Designation
0x4000 Identification and Diagnosis
0x800A Measurement Data Channel (standard
resolution)
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5.6
IO-Link resolution pressure [mbar] 0.01
IO-Link resolution [K]
0.2
temperature
IO-Link process data function bit length
(cyclical) pressure 32
temperature 32
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours
counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs Type of operation DeviceID
default 1152
Operating conditions
Ambient temperature [°C] -25...80
Storage temperature [°C] -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC DIN EN 61326-1
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 201
Note on approval factory certificate available as download at www.factory-certificate.ifm
UL approval UL Approval no. J048
File number UL E174189
Mechanical data
Weight [g] 347.9
Housing cylindrical
Dimensions [mm] Ø 50 / L = 106.4
Materials stainless steel (316L/1.4404); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts) ceramics (99.9 % Al2O3); stainless steel (316L/1.4435);
surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles 100 million
Tightening torque [Nm] 25
Process connection threaded connection S30x2 external thread Aseptoflex
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Displays / operating elements
Display Display unit LED, green
switching status LED, yellow
function display alphanumeric display, 4-digit
measured values alphanumeric display, 4-digit
Display unit mbar; kPa; inH2O; mmWS
Remarks
Notes Please do not use for new projects.; no more adapters available as accessories
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Connection
1 connection for 2-wire operation
2 connection for 3-wire operation
OUT1 switching output / IO-Link
OUT2 switching output / analogue output
3 connection for IO-Link parameter setting (P = communication via IO-Link)
colours to DIN EN 60947-5-2
Core colours
BK = black
BN = brown
BU = blue
WH = white
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —
PI1008
Flush pressure sensor with display
PI-,25BRES30-MFRKG/US/ /P
Diagrams and graphs
ambient temperature influence on
the accuracy
X temperature
Y total deviation
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1008-00 — 13.11.2023 —